Horse Serum Amyloid A ELISA

Similar documents
Human Leptin ELISA. Cat. No. KT-1120 K-ASSAY. For the quantitative determination of leptin in human biological samples. For research use only.

Cat Serum Amyloid A (SAA) ELISA

Cat IgA ELISA. Cat. No. KT-755 K-ASSAY KAMIYA BIOMEDICAL COMPANY. For the quantitative determination of IgA in cat biological samples

Human Alpha 1-Anti- Chymotrypsin ELISA

Mouse Lipocalin-2/NGAL ELISA

Mouse IgE ELISA. Cat. No. KT-401 K-ASSAY. For the quantitative determination of IgE in mouse biological samples. For Research Use Only.

Rat Alpha Glutathione S- Transferase ELISA

Rat Liver Fatty Acid Binding Protein (L-FABP) ELISA

Dog NGAL ELISA. For the quantitative determination of NGAL (Lipocalin-2) in dog biological samples. Cat. No. KT-546. For Research Use Only.

Pig IgG ELISA. Cat. No. KT-516 K-ASSAY. For the quantitative determination of IgG in pig biological samples. For Research Use Only. 1 Rev.

KAMIYA BIOMEDICAL COMPANY. Cat IgE ELISA. For the quantitative determination of IgE in cat biological samples. Cat. No. KT-394. For Research Use Only.

Mouse IgG2B ELISA. Cat. No. KT-405 K-ASSAY. For the quantitative determination of IgG2B in mouse biological samples. For Research Use Only.

Dog IgM ELISA. Cat. No. KT-458 K-ASSAY. For the quantitative determination of IgM in dog biological samples. For Research Use Only. 1 Rev.

Rat Glutathione S-Transferase Yb1 (GST Yb1) ELISA

Human Lipocalin-2/NGAL ELISA

Mouse Myeloperoxidase ELISA

Human Lactoferrin ELISA

Mouse Ferritin ELISA

Human Myeloperoxidase ELISA

LCN2 (Dog) ELISA Kit. Catalog Number KA assay Version: 01. Intend for research use only.

IgG (Cat) ELISA Kit. Catalog Number KA assay Version: 01. Intend for research use only.

Human Beta 2-Microglobulin ELISA

Dog Complement C3 ELISA

IgE (Dog) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

Guinea Pig Complement C3 ELISA

Rat Alpha-1 Acid Glycoprotein ELISA

IgE (Rat) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

Mouse Complement C3 ELISA

Pig Microalbumin ELISA

TF (Bovine) ELISA Kit

IgG (Rabbit) ELISA Kit

Prealbumin (Mouse) ELISA KitI

Cystatin C ELISA. For the quantitative determination of cystatin C in human biological samples.

Rabbit IgA ELISA Kit

Mouse IgE ELISA. For the quantitative determination of IgE in mouse serum or plasma. For Research use Only. Not For Use In Diagnostic Procedures.

KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule in various biological samples.

Rat Microalbumin ELISA

IgA ELISA. For the quantitative determination of IgA in human serum and plasma. For Research Use Only. Not for Use in Diagnostic Procedures.

IgD ELISA. For the quantitative determination of IgD in Human serum and plasma. Please See Appendix A for Reference Serum Information

IgD ELISA. For the quantitative determination of IgD in Human Sera. Please See Appendix A for Reference Serum Information

IgG (Bovine) ELISA Kit

IgA (Guinea Pig) ELISA Kit

C3 (Mouse) ELISA Kit. Catalog Number KA assays Version: 15. Intended for research use only.

Dog Microalbumin ELISA

IgG (Canine) ELISA. Please see Appendix A for Reference Serum information. For Research Use Only. Not For Use In Diagnostic Procedures.

Mouse Retinol Binding Protein 4 ELISA

IgM (Canine) ELISA. For the quantitative determination of IgM in canine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Mouse Transferrin ELISA

Mouse Ferritin ELISA

The Human IgD ELISA KIT is a highly sensitive two-site enzyme linked immunoassay (ELISA) for measuring IgD in Human Biological Samples.

IgA ELISA. For the quantitative determination of IgA in human serum and plasma. Please see Appendix A for Reference Serum Information

For the quantitative determination of IgE in equine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Rat Ferritin ELISA. For the determination of ferritin in serum and plasma of rats. For Research Use Only. Not For Use In Diagnostic Procedures.

Mouse Myeloperoxidase ELISA

HUMAN MYELOPEROXIDASE

Mouse KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule in mouse serum, plasma, or urine.

Canine Lipocalin-2 (NGAL) ELISA KIT

CANINE COMPLEMENT FACTOR 3 (C3) ELISA

Casein (Bovine) ELISA Kit

Mouse Haptoglobin ELISA

Cat Haptoglobin ELISA

Rat Beta-2 Microglobulin ELISA

Dog High-Sensitive CRP ELISA

Rat High-Sensitive CRP ELISA

Hp (Rat) ELISA Kit. Catalog Number KA assays Version: 01. Intended for research use only.

Pig High-Sensitive CRP ELISA

HP (Rabbit) ELISA Kit

Haptoglobin (Horse) ELISA Kit

Crp (Mouse) ELISA Kit

Mouse C-Reactive Protein ELISA

Rabbit C-Reactive Protein ELISA

CRP (Pig) ELISA Kit. Catalog Number KA assay Version: 03. Intended for research use only.

Haptoglobin ELISA. For the quantitative determination of haptoglobin in human serum and plasma.

Porcine C-Reactive Protein ELISA

ab IgE Cat ELISA Kit

ab Ferritin (FTL) Rat ELISA Kit

ab IgA Cat ELISA Kit

ab Retinol Binding Protein (RBP) Dog ELISA Kit

ab C Reactive Protein (PTX1) Dog ELISA Kit

ab IgA Pig ELISA Kit

ab IgE Mouse ELISA Kit

ab Pig CRP ELISA Kit

ab Bovine IgG ELISA Kit

ab Dog NGAL ELISA Kit

Mouse Glutathione S Transferase Alpha 1 (GSTa1)

ab IgG Mouse ELISA Kit

ab Mouse IgE ELISA Kit

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA

ab CRP Cat ELISA Kit

Human Superoxide Dismutase 2 (SOD2) ELISA

RUO. DRG Amyloid beta Auto-Ab (serum) As of 14 Dec rm (Vers. 1.1)

Human vitamin A (VA) ELISA

Human papillomavirus,hpv ELISA Kit

Mouse Platelet Factor 4 (PF4) ELISA

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit

Rat Low Density Lipoprotein (LDL) ELISA

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit

Human placenta lactogen, HPL ELISA kit

Hepatitis B virus IgM ELISA Kit

Human anti-ganglioside IgG antibody (GM1-IgG) ELISA Kit

Transcription:

K-ASSAY Horse Serum Amyloid A ELISA For the quantitative determination of Serum Amyloid A (SAA) in horse biological fluid Cat. No. KT-660 For research use only. 1 Rev. 13505660

K-ASSAY PRODUCT INFORMATION Horse Serum Amyloid A ELISA Cat. No. KT-660 INTENDED USE The Horse SAA ELISA is a highly sensitive two-site enzyme-linked immunoassay (ELISA) for the quantitative determination of SAA in horse biological fluid. For research use only. PRINCIPLE The principle of the double antibody sandwich ELISA is represented in Figure 1. In this assay the SAA present in the sample reacts with the anti-saa antibodies which have been adsorbed to the surface of polystyrene microtiter wells. After the removal of unbound proteins by washing, the Detection Antibody, biotin conjugated anti-saa, is added and complexes are formed. Following a wash step, the horseradish peroxidase (HRP) conjugated Streptavidin is added and complexes are formed. After another washing step, the complexes are assayed by the addition of a chromogenic substrate, 3,3,5,5 - tetramethylbenzidine (TMB). The quantity of bound enzyme is proportional to the concentration of SAA in the sample tested; thus, the absorbance, at 450 nm, is a measure of the concentration of SAA in the test sample. The quantity of SAA in the test sample can be interpolated from the calibration curve constructed from the calibrators, and corrected for sample dilution. Figure 1. Anti-SAA Antibodies Bound To Solid Phase Calibrators and Samples Added SAA * Anti-SAA Complexes Formed Unbound Sample Proteins Removed Detection Antibody Added Complexes Formed Unbound Protein Removed HRP Streptavidin Added Complexes Formed Unbound HRP Removed Chromogenic Substrate Added Determine Bound Enzyme Activity COMPONENTS 1. Diluent Concentrate One bottle containing 60 ml of a 1X concentrated diluent running buffer. 2. Wash Solution Concentrate One bottle containing 50 ml of a 20X concentrated wash solution. 3. Detection Antibody 100X One vial containing 150 µl of affinity purified anti-horse SAA antibody conjugated with biotin in a stabilizing buffer. 2 Rev. 13505660

4. HRP-Streptavidin 100X One vial containing 150 µl of Horseradish Peroxidase conjugated streptavidin in a stabilizing buffer. 5. TMB Substrate Solution One vial containing 12 ml of TMB and hydrogen peroxide in citric acid buffer at ph 3.3. 6. Stop Solution One vial containing 12 ml of 0.3 M sulfuric acid. WARNING: Avoid contact with skin. 7. Microtiter Plate Twelve removable eight-well micro strips in well holder frame. Wells are coated with affinity-purified anti-horse SAA. 8. Horse SAA Calibrator One vial containing a lyophilized Horse SAA Calibrator. MATERIALS REQUIRED BUT NOT PROVIDED Precision pipette (2 µl to 200 µl) for making and dispensing dilutions Test tubes Microplate washer/aspirator Distilled or de-ionized H 2 O Microplate reader Assorted glassware for the preparation of reagents and buffer solutions Timer Orbital Shaker PRECAUTIONS 1. Read the instructions carefully before beginning the assay. 2. This kit is for research use only. 3. Great care has been taken to ensure the quality and reliability of this product. However, it is possible that in certain cases, unusual results may be obtained due to high levels of interfering factors. 4. No additives or preservatives are necessary to maintain the integrity of the specimen. Avoid azide contamination. 5. Azide and thimerosal at concentrations higher than 0.1% inhibit the enzyme reaction. 6. Other precautions: Do not interchange kit components from different lots. Do not use kit components beyond the expiration date. Protect reagents from direct sunlight. Do not pipette by mouth. Do not eat, drink, smoke or apply cosmetics where reagents are used. Avoid all contact with the reagents by using gloves. Stop solution contains diluted sulfuric acid. Irritation to eyes and skin is possible. Flush with water after contact. REAGENT PREPARATION 1. Diluent Concentrate Ready to use as supplied. 2. Wash Solution Concentrate The Wash Solution supplied is a 20X concentrate and must be diluted 1:20 with distilled or de-ionized water. Crystal formation in the concentrate is not uncommon when storage temperatures are low. Warming of the concentrate to 30-35 C before dilution can dissolve crystals. 3. Detection Antibody 100X Calculate the required amount of working conjugate solution for each microtiter plate test strip by adding 10 µl detection antibody to 990 µl of 1X Diluent for each test strip to be used for testing. Mix uniformly, but gently. Avoid foaming. 4. HRP-Streptavidin 100X 3 Rev. 13505660

Calculate the required amount of working conjugate solution for each microtiter plate test strip by adding 10 µl HRP- Streptavidin to 990 µl of 1X Diluent for each test strip to be used for testing. Mix uniformly, but gently. Avoid foaming. 5. TMB Substrate Solution Ready to use as supplied. 6. Stop Solution Ready to use as supplied. 7. Microtiter Plate Ready to use as supplied. Unseal Microtiter Pouch and remove plate from pouch. Remove all strips and wells that will not be used in the assay and place back in pouch and re-seal along with desiccant. 8. Horse SAA Calibrator Add 1.0 ml of distilled or de-ionized water to the Horse SAA calibrator and mix gently until dissolved. The calibrator is now at a concentration of 3.384 µg/ml (the reconstituted calibrator should be aliquoted and frozen if future use is intended). Horse SAA calibrators need to be prepared immediately prior to use (see chart below). Mix well between each step. Avoid foaming. Calibrator Concentration Calibrator Volume added (ng/ml) to 1X Diluent Volume of 1X Diluent 6 72 20 µl Horse SAA 920 µl Calibrator 5 36 0.3 ml Calibrator 6 0.3 ml 4 18 0.3 ml Calibrator 5 0.3 ml 3 9 0.3 ml Calibrator 4 0.3 ml 2 4.5 0.3 ml Calibrator 3 0.3 ml 1 2.25 0.3 ml Calibrator 2 0.3 ml 0 0 0.6 ml STORAGE AND STABILITY 1. Complete Kit The expiration date for the kit is stated on the outer label. The recommended storage temperature is 4 C. Note: See long term storage recommendations below for the Horse SAA Calibrator. 2. Diluent The 1X Diluent Concentrate is stable until the expiration date and should be stored at 4 C. 3. Wash Solution The 20X Wash Solution Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions can be stored at room temperature (RT, 16-25 C) or at 4 C. 4. Detection Antibody 100X Undiluted Biotin conjugated anti-saa should be stored at 4 C and diluted immediately prior to use. 5. HRP-Streptavidin 100X Undiluted horseradish peroxidase conjugated streptavidin should be stored at 4 C and diluted immediately prior to use. 6. TMB Substrate Solution The TMB Substrate Solution should be stored at 4 C and is stable until the expiration date. 7. Stop Solution The Stop Solution should be stored at 4 C and is stable until the expiration date. 8. Microtiter Plate Anti-horse SAA coated wells are stable until the expiration date and should be stored at 4 C in the sealed foil pouch with a desiccant pack. 4 Rev. 13505660

9. Horse SAA Calibrator The lyophilized Horse SAA calibrator should be stored at 4 C or frozen until reconstituted. The reconstituted calibrator should be aliquoted out and stored frozen (avoid multiple freeze-thaw cycles). The working calibrator solutions should be prepared immediately prior to use and are stable for up to 8 hours. INDICATIONS OF INSTABILITY If the test is performing correctly, the results observed with the calibrator solutions should be within 20% of the expected values. SPECIMEN COLLECTION AND HANDLING Blood should be collected by venipuncture and the serum separated from the cells, after clot formation, by centrifugation. For plasma samples, blood should be collected into a container with an anticoagulant and then centrifuged. Care should be taken to minimize hemolysis, excessive hemolysis can impact your results. Assay immediately or aliquot and store samples at -20 C. Avoid repeated freezing/thawing. For any sample that might contain pathogens, care must be taken to prevent contact with open wounds. No additives or preservatives are necessary to maintain the integrity of the specimen. Avoid azide contamination. ASSAY PROTOCOL Dilution of Samples The assay for quantification of SAA in samples requires that each test sample be diluted before use. For a single step determination a dilution of 1:200 is appropriate for most serum/plasma samples. For absolute quantification of samples that yield results outside the range of the calibration curve, a lesser or greater dilution might be required. If unsure of sample level, a serial dilution with one or two representative samples before running the entire plate is highly recommended. To prepare a 1:200 dilution of sample, transfer 2 µl of sample to 398 µl of 1X Diluent. This gives you a 1:200 dilution. Mix thoroughly. Procedure 1. Bring all reagents to RT before use. 2. Pipette 100 µl of Calibrator 0 (0.0 ng/ml) in duplicate Calibrator 1 (2.25 ng/ml) in duplicate Calibrator 2 (4.5 ng/ml) in duplicate Calibrator 3 (9 ng/ml) in duplicate Calibrator 4 (18 ng/ml) in duplicate Calibrator 5 (36 ng/ml) in duplicate Calibrator 6 (72 ng/ml) in duplicate 3. Pipette 100 µl of diluted sample (in duplicate) into pre-designated wells. 4. Incubate the Microtiter Plate while shaking on an orbital shaker at 22 C (RT) for sixty (60 ± 2) minutes. Keep plate covered and level during incubation. 5. Following incubation, aspirate the contents of the wells. 6. Completely fill each well with appropriately diluted Wash Solution and aspirate. Repeat three times, for a total of four washes. If washing manually; completely fill wells with wash buffer, invert the plate and pour/shake out the contents in a waste container. Follow this by sharply striking the wells on absorbent paper to remove residual buffer. Repeat 3 times for a total of 4 washes. 7. Pipette 100 µl of appropriately diluted detection antibody to each well. Incubate while shaking on an orbital shaker at 22 C (RT) for twenty (20 ± 2) minutes. Keep plate covered in the dark and level during incubation. 8. Wash and blot the wells as described in Steps 5 and 6. 9. Pipette 100 µl of appropriately diluted HRP-streptavidin to each well. Incubate while shaking on an orbital shaker at 22 C (RT) for twenty (20 ± 2) minutes. Keep plate covered in the dark and level during incubation. 5 Rev. 13505660

10. Wash and blot the wells as described in Steps 5 and 6. 11. Pipette 100 µl of TMB Substrate Solution into each well. 12. Incubate in the dark while shaking on an orbital shaker at RT for precisely ten (10) minutes. 13. After ten (10) minutes, add 100 µl of Stop Solution to each well. 14. Determine the absorbance at 450 nm of the contents of each well. Calibrate the plate reader to manufacturer's specifications. The absorbance of the final reaction mixture can be measured up to 2 hours after the addition of the Stop Solution. However, good laboratory practice dictates that the measurement be made as soon as possible. RESULTS 1. Subtract the average background value from the test values for each sample. 2. Using the results observed for the calibrators construct a calibration curve. The appropriate curve fit is that of a fourparameter logistics curve. A second order polynomial (quadratic) or other curve fits may also be used. 3. Interpolate test sample values from calibration curve. Correct for sample dilution factor to arrive at SAA concentration in original sample. QUALITY CONTROL In accord with good laboratory practice, the assays for specific SAA require meticulous quality control. Each laboratory should use routine quality control procedures to establish inter- and intra-assay precision and performance characteristics. LIMITATION OF THE PROCEDURE 1. Reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understanding of the information contained in the package insert instructions and with adherence to good laboratory practice. 2. Factors that might affect the performance of the assay include proper instrument function, cleanliness of glassware, quality of distilled or de-ionized water, and accuracy of reagent and sample pipetting, washing technique, incubation time or temperature. FOR RESEARCH USE ONLY 12779 Gateway Drive, Seattle, WA 98168 Tel: (206) 575-8068 Fax: (206) 575-8094 Email: LifeScience@k-assay.com www.k-assay.com 6 Rev. 13505660