Punnett, Campbell and Vacala, Trevor - Integrating Microlab into General Chemistry I & II Experiments

Similar documents
6 Acid Base Titration

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

CHEMISTRY. Section II (Total time 95 minutes) Part A Time 55 minutes YOU MAY USE YOUR CALCULATOR FOR PART A.

(a) What name is given to this method? (1) (b) Which piece of apparatus should be used to measure the 25.0cm 3 of KOH?

SAMPLE CHEMISTRY QUESTIONS MIXTURE OF UNIT 3 & 4 MATERIALS

IB Chemistry Solutions Gasses and Energy

Calorimetric Determination of Reaction Enthalpies

Name: Thermochemistry. Practice Test C. General Chemistry Honors Chemistry

Experiment 8 and 9 Weak Acids and Bases: Exploring the Nature of Buffers

ELECTROCHEMICAL CELLS

4.6 Describing Reactions in Solution

TITRATION. Exercise 0. n c (mol dm V. m c (1) MV

Draw one line from each solution to the ph value of the solution. Solution ph value of the solution

_._.._-. 110JJ2 _ ~._~_.._g:..n _E..I$/;rfI~:~!:..~.Q_.SQ.Q.L<:J..~..' -'- - '- - ~'- -1

Titration Curves. What is in the beaker at each stage of a titration? Beaker A Beaker B Beaker C Beaker D. 20 ml NaOH Added

#13 Electrochemical Cells

12. Acid Base Equilibria

Jawapan. Chemistry. Chemistry Paper 1(4541/1) SOALAN ULANGKAJI SPM 2010 [4541/1] [4541/2] [4541/3]

Name: Section: Score: /10 PRE LABORATORY ASSIGNMENT EXPERIMENT 7

2002 D Required 2001 D Required

Chemistry Determination of Mixed Acids

EXPERIMENT 9 ENTHALPY OF REACTION HESS S LAW

10 Enthalpy changes Answers to Activity and Practice questions

8. Draw Lewis structures and determine molecular geometry based on VSEPR Theory

Chemistry 3202 Pre-Public Examination May 2012 Name:

Interview Notes. m) calorimeter b) temperature. o) isolated system d) heat of reaction. p) enthalpy of formation e) heat capacity

2012 Chem R & E Project Topics and Questions

ph Measurement and its Applications

Concentration Cells. Lab Section. Problem Statement: How does concentration affect the electrical properties of chemical reactions?

Determining the Enthalpy of a Chemical Reaction

EXPERIMENT 5 ACID-BASE TITRATION

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets

Concentration of Solutions

PHYSICAL SCIENCES/ P2 1 SEPTEMBER 2015 CAPS CAPE WINELANDS EDUCATION DISTRICT

Page 2. Q1.Water dissociates slightly according to the equation: H 2 O(I) The ionic product of water, K w, is given by the expression

EXPERIMENT 23 Lab Report Guidelines

5 Acid Base Reactions

ELECTROCHEMICAL CELLS NAME ROW PD

5 Energy from chemicals

8 Enthalpy of Reaction

AP Chemistry Review Packet # form B. How many grams of water are present in 1.00 mol of copper(ii) sulfate pentahydrate?

DETERMINING AND USING H

NCEA Level 1 Science (90944) 2017 page 1 of 6. Q Evidence Achievement Achievement with Merit Achievement with Excellence

Chemical Reaction Defn: Chemical Reaction: when starting chemical species form different chemicals.

Name Class Date. volume of solution molarity of solution amount of solute in moles

HONORS CHEMISTRY Putting It All Together II

CHEMISTRY. Section II (Total time 95 minutes) Part A Time 55 minutes YOU MAY USE YOUR CALCULATOR FOR PART A.

Standardization of a Primary Standard & Determination of Concentration by Acid-Base Titration

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

Chapter 4 Reactions in Aqueous Solutions. Copyright McGraw-Hill

Part A: Multiple Choice (23 marks total)

Base your answers to questions 1 through 4 on the information below and on your knowledge of chemistry.

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

Prince George s Community College PL 2: CHARACTERIZATION OF A MONOPROTIC WEAK ACID BY POTENTIOMETRIC TITRATION

40S CHEMISTRY FINAL EXAM PROBLEM REVIEW SHEET:

Determination of the Identity of an Unknown Weak Acid

General Chemistry 1412 Spring 2008 Instructor: Dr. Shawn Amorde Website:

Energetics. Exothermic and endothermic reactions

Unit 13 Redox Reactions & Electrochemistry Ch. 19 & 20 of your book.

EXPERIMENT 6. Properties of Buffers INTRODUCTION

HESS S LAW: ADDITIVITY OF HEATS OF REACTION

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid

Experiment 3: Acids, Bases, and Buffers

Additivity of Heats of Reaction: Hess s Law

Guided Notes and Practice- Topi 5.1: Calorimetry and Enthalpy Calculations

Determination of the Rate of a Reaction, Its Order, and Its Activation Energy

Chesapeake Campus Chemistry 111 Laboratory

Experiment #12. Enthalpy of Neutralization

1.12 Acid Base Equilibria

Chemistry CP Lab: Additivity of Heats of Reaction (Hess Law)

Topic 9: Acids & Bases

Experiment 2: Reaction Stoichiometry by Thermometric Titration

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

vankessel et al (2003). Chapter 3. Zumdahl & Zumdahl (2000). Chapter 7.

International Advanced Level Chemistry Advanced Subsidiary Unit 3: Chemistry Laboratory Skills I

ACID-BASE TITRATION AND PH

Conductivity of Electrolytes in Solution

Experiment 4 Stoichiometry: The Reaction of Iron with Copper(II) Sulfate

Electrochemistry. Part I: Electrochemical Activity from Chemical Reactions. Part II. Electrochemical activity from cell potentials.

using simple distillation and paper chromatography practical to obtain a

Potentiometric Determination of the pka and the Equivalent Weight of a Weak Acid

Chemistry 212 THE ENTHALPY OF FORMATION OF MAGNESIUM OXIDE LEARNING OBJECTIVES

YEAR 10- Chemistry Term 1 plan

Chapter Four. Chapter Four. Chemical Reactions in Aqueous Solutions. Electrostatic Forces. Conduction Illustrated

She carries out two experiments.

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

Concentration of Solutions

Edexcel Chemistry Checklist

A level Chemistry Preparation Work

Ions in Solution. Solvent and Solute

40S CHEMISTRY FINAL EXAM PROBLEM REVIEW SHEET:

4-4 Chemical changes Chemistry

1. A. Define the term rate of reaction. The measure of the amount of reactants being converted into products per unit amount of time

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education CHEMISTRY

3. When the external pressure is kpa torr, water will boil at what temperature? a C b C c. 100 C d. 18 C

Mole Concept 5.319% = = g sample =

Calorimetry. Enthalpy of Neutralization

SHOW YOUR WORK. NO WORK, NO CREDIT

The Enthalpies of Reactions

Transcription:

Punnett, Campbell and Vacala, Trevor - Integrating Microlab into General Chemistry I & II Experiments Introduction Our project was centered around a new piece of equipment, Microlab, which has the capability to replace or add to equipment currently in use in the Chemistry department. Microlab is, on whole, smaller, cheaper, and more efficient than the equipment used in many of the experiments in the General Chemistry laboratory sections. Though it is not necessarily more accurate than existing instruments, its other qualities stand to serve the Chemistry Department and future chemistry students greatly. The goal of our summer project was to redo General Chemistry experiments with the use of Microlab and to check if data obtained from Microlab was worse, comparable, or better than data obtained using existing instruments. Microlab could only be integrated in some laboratory experiments based on the sensors Microlab has to offer. Thus, out of the 26 experiments performed in the General Chemistry laboratory sections, only 11 of these experiments could be redone. Experiment 1: Absorbency Plots of Vitamin B12 One of the first experiments done in chemistry lab is to make a absorbency plot, or Beer s Law plot, of standard solutions of vitamin B12. Beer s Law states that the amount of light

absorbed by a solution is directly proportional to the concentration of the solution. Measurements of absorbed light are made by an instrument call a spectrophotometer, which is just one of the instruments offered in Microlabs arsenal. Standard solutions of varying and known concentration are made for an accurate Beer s law plot, which can then be used to identify the concentration of an unknown solution based on its absorption. A set of standard solutions were made at the same concentrations used in the laboratory sections. Microlab actually had a smaller correlation coefficient (a statistically calculated number used to judge the accuracy of data) then the instruments used in laboratory, but it performed comparably well at one-half and one-fourth concentrations. Thus, Microlab could serve as reasonable substitute for current instruments and be more cost efficient since it performs better at lower concentrations. Ocean Optics, a smaller spectrophotometer, was also tested with all of the same samples used in Microlab. It obtained quality data at all concentrations and could also replace machines currently in use. Experiment 2: Copper (II) Ions in [Cu(NH 3 ) 4 ]SO 4 -H 2 O The same procedure was used in this experiment as in Experiment 1. A set of standard solutions were made of copper tetraamine (Cu(NH) 4 ) in 6 molar nitric acid according to the same concentrations used in laboratory sections. Both Microlab and Ocean Optics data were as accurate as data obtained used by current machines. Both Microlab and Ocean Optics could be easily integrated into this experiment.

Experiment 3: Conductors and Non-conductors This experiment is slightly tweaked from its laboratory counterpart. In regular lab, the conductance of several ionic solutions of varying concentration and strength are tested using the lightbulb test. This test consists of dipping two electrodes into the desired solution; the solution completes the circuit to the lightbulb and the intensity from the resulting light can be used to estimate the conductance of tested solution. This approximation of intensity consists of four possibilities: non-existent, weak, strong, and very strong. Microlab enables students to obtain quantifiable data with the use of its conductivity probe. Only conductive solutions were chosen to test the conductivity probe, which amounted to five in total. All five solutions acted as predicted, with lower concentration and less conductive solutions having a smaller conductance values than high concentration and highly conductive solutions. If Microlab were integrated into this experiment, it would give data which may better convey the ideas of conductance. Experiments 4: Fractional Distillation The main idea of fractional distillation is that two or more substances in a solution together can be separated by their different boiling points, which is dependent on the strength of their intermolecular forces. The apparatus for this experiment requires a solution of cyclopentane and

cyclohexane to be heated until they boil. A thermometer is set up at the top of the apparatus to measure the temperature of passing gasses. After the gasses pass the thermometer, they condense and drip out of the apparatus. The drips are counted and the temperature at which they fell is recorded. This information can be graphed and can clearly illustrate a separation of boiling point, since good graphs results in a two clusters of points at separate temperatures. For the Microlab experiment, a thermistor was used instead of a thermometer and a drop counter was used to automatically count the drops as they fell. This setup resulted in unreliable data. A second trial was conducted without the drop counter. The results were more reliable, but not comparable or better than data obtained from standard lab protocol. A third trial was conducted with a insulation around exposed parts of the thermistor, which could have previously effected results. Again, however, the results obtained were not good enough to replace the standard lab protocol. An improper calibration of the thermistor used may be at the heart of the problem. This problem should be fixed before Microlab gets integrated in General laboratory use. Experiment 5: The Nerst Equation and Formation Constants This experiment relies on experimentally obtained data from electric half-cells to calculate formation constants of silver, a numerical value which describes the bonding behavior of silver with ions at equilibrium. This experiment was done using the Microlab voltmeter and multiple half-cell module. This

experiment relies heavily on precise measurements of voltages between cells, which the Microlab voltmeter does not do as well as current instruments. The Microlab voltmeter only gives data to two significant figures, while current instruments give three. Formation constant values obtained from Microlab data were significantly lower then the real values. There is nothing wrong with the voltmeter, but it may not be sensitive enough to give accurate data in present laboratory conditions. The one upside to using Microlab half-cell module is that is uses fewer supplies then the current lab conditions. Thus, if the experiment used materials that gave higher half-cell voltages, then Microlab could integrated as a more cost-effective alternative. Experiment 6: Enthalpy Changes in a Copper and Zinc Reaction This lab exercise is typically not conducted in General lab, but was tested anyway. Enthalpy describes the amount of heat that is given off or taken in by a reaction. A negative enthalpy describes a reaction which gives off heat (exothermic) while a positive enthalpy corresponds to one which takes heat to proceed (endothermic). The goal of this experiment is to measure the heat given of by the exothermic reaction between zinc metal and copper ions in an aqueous solution. The amount of heat given off (given in Joules per mol of reactants) can be calculated from the change in temperature- the highest recorded temperature minus the lowest. The experimental apparatus was relatively simple. Two styrofoam cups were used to insulate the reacting copper and zinc solution and a thermistor was placed into the solution to record temoerature. Three trials of this experiment were done. All three experimentally obtained values for the enthalpy change were lower than real values, but were fairly consistent between each other. This leads to the conclusion that there may again be some calibration issues with the

thermistor or that there was some other consistent error between them all. More work needs to be done with the thermistor before it can be reliably used in General lab. Experiment 7: Titration of a Diprotic acid with a standardized base This experiment is usually a two-week project, standardizing the base the first week and then titrating the unknown acid the second. However, Microlab makes it possible to combine both into a one lab experiment. The base used in this experiment was roughly 1 molar sodium hydroxide (NaOH). Using Microlab's constant volume drop dispenser, we were able to easily titrate three unknown masses of potassium hydrogen phthalate (KHP) and calculate the exact molarity of the base. After the base was standardized, we then used it to titrate three unknown diprotic acids. A diprotic acid differs from a monoprotic acid, in that its structure contains two hydrogen atoms per molecule of base consumed. Microlab's drop counter and ph meter were used in this experiment in order to graph ph vs. time. As a result, a beautiful graph of the titration was created. The graph highlights the two endpoints of the titration, only possible with a diprotic acid. The results from this experiment, as well as its ease compared to the traditional method, make Microlab a great substitution for our current equipment.

Experiment 8: Neutralization This lab experiment consisted of neutralizing an acid with a base, and measuring the change in temperature of the reaction. The change in temperature corresponds to the change in enthalpy of the net ionic reaction. In this experiment, 2 molar hydrochloric acid (HCl) and 2 molar sodium hydroxide (NaOH) were used as the acid and base, respectively. Traditionally, we were to use alcohol-based thermometers and constantly estimate their value as the reaction progressed. With Microlab, a thermocouple was used which gave us far more accurate data than the thermometers. Before, students had to constantly be looking at the temperature readings, but with Microlab, the values are kept in a data table and can easily be exported to excel for comparison. Satisfactory temperature results were achieved with Microlab, indicating that it may be used as a replacement for the traditional, alcohol-based thermometers we currently use.

Experiment 9: The acid equilibrium constant for Methyl red In this experiment, Microlab's spectrophotometer was used to measure absorbance values for various mixtures of both methyl red's acidic and basic form with hydrochloric acid and acetic acid. Combining these substances resulted in variant shades of orange and yellow, creating a visually appealing lab environment. After the fifteen samples were made, absorbance values at two different wavelengths (525nm and 405nm) were measured. The plots of the absorbance values agreed greatly with the plots from the UV/Vis spectrophotometer used in lab. From the slopes of these lines and the ph values of the buffer solutions created, we are able to determine the acid equilibrium constant for Methyl red. Our results agreed with the accepted value with a percent error less than two. Microlab is perfect for this lab; instead of using multiple different pieces of equipment, Microlab is an all-inone solution to the problem.

Experiment 10: Electroplating copper in copper sulfate This lab is not a part of General Chemistry I or II, however, Microlab included this lab and equipment to perform it, so we decided to test it out anyway. This experiment involved running current through two electrodes (copper wire) in a copper sulfate solution. With Microlab, we are able to measure the amount of current that has passed, and with an analytical balance we can determine the mass of the copper wire before and after the experiment. With these two pieces of data, we can calculate Avogadro's number, the amount of molecules in 1 mol. It's difficult to measure the mass of the wires, as some of the electroplated copper easily falls off when extracting it from the copper sulfate solution. In the photo to the right, the anode is on the left and the cathode on the right. Oxidation occurs at the anode, which causes it to lose mass. The copper that the anode loses transfers through the solution of copper sulfate and then collects on the cathode, which gains mass. The results of our experiment were fair, but not perfect. With a little tweaking, this could possibly be a viable experiment in the General Chemistry lab.

Experiment 11: A Clock Reaction In this experiment, the concentrations of the reactants determined the time it took for the reaction to complete. A starch indicator was used to determine when the reaction finished, and in the presence of triiodide. Traditionally, timers were used and students needed to react quickly to stop the timer as soon as the reaction was finished. With Microlab's light sensor, thermocouple, and timer, it measures all of the data far more accurately than a student with a timer. The thermocouple is used to make sure all reactions occurred at similar temperatures. The light sensor was placed into the reaction beaker, and used to determine the end of the reaction. The solution is initially clear, and the light sensor reads a relatively high reading. As the reaction progresses, the solution turns darker and darker and the light sensor reads a constantly lowering value. It would have been a better option to use Microlab's spectrophotometer in this lab, however, it is still a work in progress in being implemented into lab experiments. The results from the light sensor were satisfactory and agreed with the measured results from actual lab. Acknowledgements We would like to thank Professor Dawn Wiser, the Chemistry department, and the Richter committee for allowing us to participate in this experience.