Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

Similar documents
Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

Nonlinear Analysis of Reinforced Concrete Bridges under Earthquakes

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

751. System identification of rubber-bearing isolators based on experimental tests

1.1 OBJECTIVE AND CONTENTS OF THE BOOK

HYBRID CONTROL STRATEGY FOR SEISMIC PROTECTION OF BENCHMARK CABLE-STAYE BRIDGE

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING

BRB and viscous damper hybrid vibration mitigation structural system: seismic performance analysis method and case studies

Nonlinear numerical simulation of RC frame-shear wall system

Software Verification

SHAKING TABLE DEMONSTRATION OF DYNAMIC RESPONSE OF BASE-ISOLATED BUILDINGS ***** Instructor Manual *****

International Journal of Advance Engineering and Research Development

Fundamental study on simple quantitative approach of damping performance for semi-active damper

1. Introduction

Self-powered and sensing control system based on MR damper: presentation and application

Boundary Nonlinear Dynamic Analysis

Real-Time Hybrid Simulation of Single and Multiple Tuned Liquid Column Dampers for Controlling Seismic-Induced Response

Response of Elastic and Inelastic Structures with Damping Systems to Near-Field and Soft-Soil Ground Motions

SEISMIC BASE ISOLATION

Investigation of semi-active control for seismic protection of elevated highway bridges

Analytical Predictive Models for Lead-Core and Elastomeric Bearing

Robust Loop Shaping Force Feedback Controller

Open Access Semi-active Pneumatic Devices for Control of MDOF Structures

The Analysis of Seismic Response for Base-isolated Structure by LS-DYNA

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

midas Civil Dynamic Analysis

ME 563 HOMEWORK # 7 SOLUTIONS Fall 2010

System Identification procedures for nonlinear response of Buckling Restraint Braces J. Martínez 1, R. Boroschek 1, J. Bilbao 1 (1)University of Chile

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

Suppression of the primary resonance vibrations of a forced nonlinear system using a dynamic vibration absorber

DEVELOPMENT OF EQUIVALENT FORCE CONTROL METHOD FOR PSEUDO- DYNAMIC AND REAL-TIME SUBSTRUCTURE TESTS ABSTRACT

Contrôle adaptatif backstepping de structures à base isolée hystérétiques

Seismic design of bridges

STRUCTURAL PARAMETERS IDENTIFICATION BASED ON DIFFERENTIAL EVOLUTION AND PARTICLE SWARM OPTIMIZATION

Preliminary Examination - Dynamics

Experimental Study of Sliding Base-Isolated Buildings with Magnetorheological Dampers in Near-Fault Earthquakes

Finite Element Modules for Demonstrating Critical Concepts in Engineering Vibration Course

Earthquake Excited Base-Isolated Structures Protected by Tuned Liquid Column Dampers: Design Approach and Experimental Verification

Preliminary Examination in Dynamics

SAFETY EVALUATION OF SEISMICALLY ISOLATED HOUSES WITH DISPLACEMENT RESTRAINT DEVICES UNDER SEVERE EARTHQUAKE MOTIONS

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

EXPLICIT EQUIVALENT FORCE CONTROL FOR REAL-TIME SUBSTRUCTURE TESTING

Damping stay-cable transverse vibration using shape memory alloys and magneto rheological dampers

Hysteresis Modelling of an MR Damper Applied to Suspension System

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

Aseismic design of structure equipment systems using variable frequency pendulum isolator

SYSTEM IDENTIFICATION & DAMAGE ASSESSMENT OF STRUCTURES USING OPTICAL TRACKER ARRAY DATA

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

Safety Margin Ratio-Based Design of Isolation Gap Size for Base-isolated Structures

STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS

Structural Control: Introduction and Fruitful Research Areas

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

Vibration Control Effects of Tuned Cradle Damped Mass Damper

Wire rope springs for passive vibration control of a light steel structure

Multi Linear Elastic and Plastic Link in SAP2000

Control of Earthquake Induced Vibrations in Asymmetric Buildings Using Passive Damping

Input-Output Peak Picking Modal Identification & Output only Modal Identification and Damage Detection of Structures using

Modelling Seismic Isolation and Viscous Damping

Influence of the Soil Structure Interaction on the Fundamental Period of Large Dynamic Machine Foundation

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

SIMULATION AND TESTING OF A 6-STORY STRUCTURE INCORPORATING A COUPLED TWO MASS NONLINEAR ENERGY SINK. Sean Hubbard Dept. of Aerospace Engineering

DEVELOPMENT OF A REAL-TIME HYBRID EXPERIMENTAL SYSTEM USING A SHAKING TABLE

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM

SMART BASE ISOLATED BENCHMARK BUILDING PART III: A SAMPLE CONTROLLER FOR BILINEAR ISOLATION

Single-Degree-of-Freedom Analytical Predictive Models for Lead-Core Bearing Devices

1338. Experimental and numerical studies on multi-spherical sliding friction isolation bearing

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

midas Civil Advanced Tutorial Nonlinear time history analysis of a bridge with seismic isolators

PROTECTING PRECISION MACHINERY USING GUIDEWAY SLIDING ISOLATOR WITH GAP SPRING AND DAMPERS

Semi-Active Control of Structures Using a Neuro-Inverse Model of MR Dampers

DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS

REAL-TIME HYBRID EXPERIMENTAL SIMULATION SYSTEM USING COUPLED CONTROL OF SHAKE TABLE AND HYDRAULIC ACTUATOR

A Study on Variance of Maximum Responses of Elastoplastic Structure Subjected to Artificial Earthquake Ground Motions

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

A Guide to linear dynamic analysis with Damping

Tuning TMDs to Fix Floors in MDOF Shear Buildings

Dynamic Analysis and Modeling of Wood-framed Shear Walls

INFLUENCE OF FRICTION MODELS ON RESPONSE EVALUATION OF BUILDINGS WITH SLIDING ISOLATION DEVICES

NUMERICAL ANALYSIS OF ELEVATED FRAMED STAGING SHALLOW TANK BY NEWMARK S STEP-BY-STEP METHOD


A parametric study of linear and non-linear passively damped seismic isolation systems for buildings

SEISMIC RELIABILITY ANALYSIS OF BASE-ISOLATED BUILDINGS

A simple approach to real-time fault detection and diagnosis in base-isolation systems

THE CAPABILITY OF THE MR DAMPER VERIFIED BY SHAKING TABLE TESTS AND REAL TIME HYBRID TESTS

EARTHQUAKES AND EARTHQUAKE-RESISTANT DESIGN OF STRUCTURES. Er. K. S. BHARGAV LECTURER Department of Civil Engineering, GGSGP CHEEKA

MOOC QP Set 2 Principles of Vibration Control

ANALYSIS OF HIGHRISE BUILDING STRUCTURE WITH SETBACK SUBJECT TO EARTHQUAKE GROUND MOTIONS

Civil Engineering. Optimization of location and forces of friction dampers. Engenharia Civil. Abstract. 1. Introduction. 2. Problem formulation

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

2.003 Engineering Dynamics Problem Set 10 with answer to the concept questions

INVESTIGATION OF JACOBSEN'S EQUIVALENT VISCOUS DAMPING APPROACH AS APPLIED TO DISPLACEMENT-BASED SEISMIC DESIGN

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

Nonlinear dynamic analysis of a structure with a friction-based seismic base isolation system

IMPORTANT FEATURES OF THE RESPONSE OF INELASTIC STRUCTURES TO NEAR-FIELD GROUND MOTION

EVALUATING RADIATION DAMPING OF SHALLOW FOUNDATIONS ON NONLINEAR SOIL MEDIUM FOR SOIL-STRUCTURE INTERACTION ANALYSIS OF BRIDGES

Application of bouc-wen model to frequency-dependent nonlinear hysteretic friction damper

Transcription:

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration L. Y. Li & J. P. Ou Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, 11624, China SUMMARY: In this paper, structural nonlinear vibration control using base isolation system is studied. A nonlinear structure model with base isolation devices is developed to analyze the control effect of base isolated structure. A bi-linear hysteresis model is incorporated into the structure to mimic nonlinear behaviors. Simulation is made on this nonlinear structure with base isolation system. It can be concluded from the simulation that for nonlinear structure with base isolation if linear structural parameters are used to calculate the related control parameters, the control effect may be worse than the case without control. Therefore, in order to design the based isolation device for nonlinear structure, nonlinear response is recommended to calculate the related control parameters. Moreover, an active control method based on the negative stiffness idea is proposed to control the nonlinear base isolated structure, which is verified by the simulation. Keywords: structural nonlinear vibration; base isolation; negative stiffness 1. INTRODUCTION Base isolation is a widely used technique to suppress the vibration of structure under earthquake excitation (Lin and Zhou, 22; Ni et al., 26; Sun et al., 26; Liu and Li, 26; Shang and Qi, 212). It can shift the fundamental frequency of the structure from the dominant period of the earthquake, and also increase the damping of the whole system. With the development of civil engineering, the structure becomes more and more flexible and higher. Even with the base isolation system, the superstructure may still exhibit the nonlinear behaviors. Therefore, it is of theoretical and practical value to study the structural nonlinear vibration with base isolation devices. Suy et al. (27) studied a base isolation system composed of linear laminated rubber bearings and viscous dampers and nonlinear friction elements. The dynamic performance of the system was analyzed in both nonlinear transient and steady-state analyses. Kikuchi et al. (28) investigated the seismic response of yielding isolated structures. The study considered both viscously damped and hysteretically damped isolation systems. Choi et al. (28) investigated the applicability of the MR damper-based smart passive control system to the seismic protection of base isolated building structures with nonlinear isolation systems such as friction pendulum bearings and lead rubber bearings. Ye et al. (21) proposed a harmonic balancing method and a gradient method to solve two-degree-of-freedom system of LRB base-isolated building structure where the nonlinearity of both LRB isolation system and superstructure were taken into

consideration. Du et al. (21) introduced an analytical method of nonlinear seismic response of high-rise isolated structure. Almost all the above studies focused on the nonlinearity of the base isolation part, while few of them considered the nonlinearity of the superstructure. In this paper the structural nonlinear vibration is studied. A bi-linear hysteresis model is used to build the nonlinearity of the superstructure. Then simulation is conducted on this nonlinear model with base isolation devices. The analysis and conclusions are presented based on the numerical results. 2. THE NONLINEAR VIBRATION MODEL OF BASE ISOLATED STRUCTURE The nth-story nonlinear shear-type structure with base isolation devices is shown in Fig. 2.1. Under the horizontal earthquake input x g, the motion of equation of the super structure based on interstory drift is: where,,, x t x1 x2 x n T Mx( t) +Cx( t) + F é n x t ë ( ),x( t) ù û = -Mhx t g ( ) (2.1) is the interstory drift of all levels. Mn n and Cn n are the mass and damping matrix of the structure, respectively. n 1 is the earthquake input vector. The hysteresis force of the nth story can be represented as: F n é ë x( t),x t ( ) ù û = K x t e ( ) + H h f é h x t ë ( ),x t ( ) ù û (2.2) where Ken n is the linear stiffness matrix of the nth story. H hr1 the location matrix of hysteresis force. f hr1 is the nonlinear hysteresis vector of the nth story. The Eqn. 2.1 can be written as a state space model: Z = AZ - B h f h ( Z) +Gx g (2.3) é where Z = ê ë x x ù I ú is the state vector. A 1 1 û M Ke M C is the linear system matrix of the structure. Bh 1 M H h and G. The mass m i, damping coefficient ci and interstory stiffness k i of each story are shown in Table 2.1.

The first three frequencies of the linear structure are 1.9 2.86 and 4.2Hz, respectively. The corresponding modal damping ratios are 2.% 5.67% and 7.7%. The hysteresis model of restoring force is chosen to be a bi-linear model. x n m n F n ( x n, x n ) m n-1 x 2 m 2 x 1 F 2 ( x 2, x 2 ) m 1 Active control device F 1 ( m b, x ) x 1 1 x b k b, c b Figure 2.1. Structural nonlinear vibration model with base isolation devices Table 2.1. Structural parameters of the 3-story nonlinear structural model 5 5 2 Story number mi 1 kg ki 1 kn/m ci 1 kn s/m 1 345.6 3.524 9.986 2 345.6 3.379 9.547 3 345.6 3.64 9.383 Base on the above derivation, the mass matrix M, the linear stiffness matrix K e and the damping matrix C can be written as: m1 1k1 2k2 c1 c2 M m2 m2, K e 2k2 3k 3, C c2 c 3 (2.4) m 3 m3 m 3 3k 3 c 3

Acceleration/(m/s2) The bi-linear model is described by the Bouc-Wen hysteresis model, which is shown as: 1 F k x t f k x t k D z (2.5) ni ei i hi i i i i yi i ( ) (2.6) z i = D -1 n i -1 n i yi A i x i - b i x i z zi i -g i x i z i where z i is the dimensionless variable of the hysteresis displacement, the value of which is between 1. The other parameters of this model are Ai 1., i i 1., ni 95. The coefficient i represents the ratio between the post-yield stiffness and pre-yield stiffness, which is.1 for each story. The yielding displacement of each story is Dyi 1.93,1.76 and 1.47cm, respectively. The location matrix H h and earthquake input vector are 1 1 1 H h 1 1, 1 (2.7) In this paper, the earthquake input is the El Centro earthquake wave, which is shown in Fig. 2.2. 4 3 2 1-1 -2-3 1 2 3 4 5 Time/s Figure 2.2. El Centro earthquake wave

Base displacement/m Base acceleration/(m/s2) 3. SIMULATION ANALYSIS OF NONLINEAR BASE ISOLATED STRUCTURE 3.1. Analysis of Linear Case At first, we consider the simulation analysis of linear structure. The stiffness of the base layer is 6.4841e+7N.m according to the first frequency of the structure. The damping coefficient of the base layer is changed from N.s/m to 4e7N.s/m. Fig. 3.1. shows the simulation results between the structural response and the damping coefficient. Fig. 3.2 shows the simulation results between the response of base layers and the damping coefficient. 7 6 8 6 5 4 4 2 3 2-2 1 2 3 4 1 2 3 4 Damping coefficient/(n.s/m) x 1 7 Damping coefficient/(n.s/m) x 1 7 a) interstory drift b) absolute acceleration Figure 3.1. Structural response with base isolation device.3.25.2.15.1.3.25.2.15.1.5.5 1 2 3 4 1 2 3 4 Damping coefficient/(n.s/m) x 1 7 Damping coefficient/(n.s/m) x 1 7 a) base displacement b) based acceleration Figure 3.2. Response of the base layer From the simulation results, it can be concluded that there exists the optimal value of the damping coefficient. In this case, when the damping coefficient is about 5e6N.m/s, the control effect of displacement will be 5%-7% and the control effect of acceleration will be 4%-7%. However, under the optimal case, the base displacement or acceleration may be excessive large, which will lead to the damage of the base.

Base displacement/m Base acceleration/(m/s2) 3.2. Analysis of Nonlinear Case 3.2.1. Simulation based on linear response For the nonlinear base isolated structure, we firstly use the linear structural parameters to design the base isolation system. Therefore, the stiffness of the isolation layer is still 6.4841e+7N.m based on the linear analysis The damping coefficient of the base is changed from N.s/m to 4e7N.s/m. Fig. 3.3. shows the simulation results between the structural response and the damping coefficient. Fig. 3.4. shows the simulation results between the response of base layers and the damping coefficient. 2 15 1 5-2 -4-5 -6 1 2 3 4 Damping coefficient/(n.s/m) x 1 7-1 1 2 3 4 Damping coefficient/(n.s/m) x 1 7 a) interstory drift b) absolute acceleration Figure 3.3. Structural response with base isolation device.9.8.7.6.5.4.3.2.1 1 2 3 4 Damping coefficient/(n.s/m) x 1 7.1.8.6.4.2 1 2 3 4 Damping coefficient/(n.s/m) x 1 7 a) base displacement b) based acceleration Figure 3.4. Response of the base layer From the above results, we can see that if linear structural parameters are used to calculate the related control parameters of nonlinear base isolated structure, the control effect is not very good. Close to the optimal damping coefficient, the control effect is only 1%-15%. Moreover, for some damping coefficient, even negative control effect can be achieved, which means that the control effect with base isolation is even worse than that without base isolation. Therefore, for nonlinear base structure design, it is not suggested to use the linear structural parameters.

Base displacement/m Base acceleration/(m/s2) 3.2.2. Simulation based on nonlinear response In order to improve the above simulation results, the nonlinear response will be used to design the base isolation system. Base on the analysis of nonlinear structural response under earthquake input, the dominant frequency of the structure is.33 Hz. Using this dominant frequency, the stiffness of the isolation layer is 4.9117e+6N.m. The damping coefficient of the base is changed from N.s/m to 4e7N.s/m. Fig. 3.5. shows the simulation results between the structural response and the damping coefficient. Fig. 3.6. shows the simulation results between the response of base layers and the damping coefficient. 8 6 8 6 4 4 2 2-2 1 2 3 4 5 6 1 2 3 4 5 6 Damping coefficient/(n.s/m) x 1 7 Damping coefficient/(n.s/m) x 1 7 a) Interstory drift b) Absolute acceleration Figure 3.5. Structural response with base isolation device.7.6.7.6.5.4.3.2.1.5.4.3.2.1 1 2 3 4 5 6 1 2 3 4 5 6 Damping coefficient/(n.s/m) x 1 7 Damping coefficient/(n.s/m) x 1 7 a) Base displacement b) Based acceleration Figure 3.6. Response of the base layer From the simulation results, it can be observed that the control effect of the based isolation structure is more satisfactory based on the nonlinear structure response than the case using linear structural parameters. 3.3. Active Control Based on Linear Structural Parameters From the previous section, it can be concluded that when the passive control is considered for the nonlinear structure analysis with the base isolation system, the related nonlinear response should be used

Interstory restore force/n Interstory displacement/m Absolute acceleration/(m/s2) to design the base isolation system. However, usually the nonlinear response is not easy to obtain unless there is some online system identification system which will further increase the complexity of the system and also raise the issue of convergence. Therefore, in the following we will design an active controller to compensate the nonlinear response, while the base isolation system is still designed according to the linear structural parameters. Due to the frequency difference of linear and nonlinear structure, we will use active control methodology to design the controller. Because of the stiffness degradation of the nonlinear system, the negative stiffness needs to be considered in the active control algorithms. Since the commonly used semi-active control devices can not provide the negative stiffness, it is suggested to use active control devices in this case. The control input is chosen to be the displacement and velocity of the base layer. Then the control method is to design a suitable displacement feedback gain to compensate the loss of stiffness and a suitable velocity feedback gain to increase the damping. It can be computed that the designed displacement feedback gain is -599293N/m and the designed velocity feedback gain is 1e6N.s/m. Fig. 3.7. and Fig. 3.8. shows the control results with the active control device. It can be observed that using the negative stiffness idea we can achieve a satisfactory control result..15.1 Without control With control 1 Without control With control.5 5 -.5 -.1-5 -.15 -.2 5 1 15 2 25 3 Time/s -1 5 1 15 2 25 3 Time/s a) interstory drift b) absolute acceleration Figure 3.7. Structural response of the 1 st floor with base isolation device 4 x 16 3 Without control With control 2 1-1 -2-3 -.2 -.15 -.1 -.5.5.1.15 Interstory displacement/m Figure 3.8. Control results of hysteresis curve of the 1 st floor

4. CONCLUSIONS In this paper, we mainly analyze the control effect of a nonlinear structure with the base isolation system. A bi-linear hysteresis model is used to simulate the material nonlinearity of the structure. The simulation is conducted on the nonlinear structure with base isolation devices. The conclusions are drawn as following: 1)For the nonlinear structure with base isolation system, if linear structural parameters are considered for the base isolation system, the control effect may be unacceptable. In some cases, it is even worse than the case without base isolation system. 2)If the base isolation system is designed based on the nonlinear response, the control effect of both displacement and acceleration will be better than the case based on linear structural parameters. Therefore, if possible it is recommended to use nonlinear response related parameters to design the nonlinear structure with base isolation system. 3)Using the concept of negative stiffness, active or semi-active device can be used to compensate the nonlinear response of the structure. ACKNOWLEDGEMENT This work was supported in part by the National Science Foundation of China under Award No. 59833 and the Fundamental Research Funds for the Central Universities under Award No. DUT11RC(3)1. REFERENCES Lin, X., Zhou F. (22). Theory and applicatoin of energy dissipation-seisimic reduction technology. World Earthquake Engineering, 18:3,48-51. Ni, G., Zhang, Y. and Zhao, Y. (26). Analysis of base isolation building system. Earthquake Engineering and Engeering Vibration, 26:3,26-29. Sun, Z., Cheng, S. and Wang, H. (26). Performance and parameter analysis of base-isolated structure with transducer. World Earthquake Engineering, 22:1,14-18. Liu, H. and Li, Z. (26). Application of SMA-rubber bearing to structural seismic isolation. Journal of Natural Disasters, 15:3,123-127. Shang, H., Qi, A. (212). Isolation mechanism of high-rise isolation structure. Journal of vibration and shock, 31:4,8-12. Suy, H. M. R., Fey, R. H. B., Galanti, F. M. B. and Nijmeijer, H. (27). Nonlinear dynamic analysis of a structure with a friction-based seismic base isolation system. Nonlinear Dynamics. 5, 523-538. Kikuchi, M., Black, C. J. and Aiken, I. D. (28). On the response of yielding seismically isolated structures. Earthquake Engineering and Structural Dynamics. 37,658-679. Choi, K., Jung, H., Lee, H. and Cho, S. (28). Seismic protection of base-isolated building with nonlinear isolation system using smart passive control strategy. Structural Control and Health Monitoring, 15,785-796. Ye, K., Fu, R. and Li, L. (21). Investigation into the dynamic behavior of LRB base-isolated building structure considering the nonlinearity of superstructure. China Civil Engineering Journal. 43,31-316. Du, D., Wang, S., Liu, W. and Wang, H. (21). Research on nonlinear seismic response Analysis and Design Method of High-rise Isolated Structure. Journal of Disaster Prevention and Mitigation Engineering. 3:5,55-557.