S-100 Antiscalant AXEON S-100 Antiscalant is a highly effective antiscalant, specially formulated for feedwaters with the highest levels of metal oxid

Similar documents
NANOSTONE Cleaning Guidelines for Spiral E-Coat Elements

FILMTEC Membranes Testing Chemical Compatibilities with FILMTEC Membranes

Membrane Clean In Place Recipe Optimization

Feed Water Parameters Assessing RO & NF Feed Water Quality

Water Soluble Polymers For Industrial Water Treatment Applications

SAWEA Innovative Water & Waste Water Technologies Workshop

VIPOL MEMBRANE CHEMICALS PROTECT YOUR RO FEEDWATER FROM SCALE, BACTERIAL GROWTH, AND FOULING

HYDRACoRe. CHLORINE TOLERANT SPIRAL WOUND Nanofiltration Color Removal Membrane Elements. February Lenntech

Lenntech Tel Fax

Module 20: Corrosion Control and Sequestering Answer Key (edited April 2017)

Lecture 10. Membrane Separation Materials and Modules

CE 370. Disinfection. Location in the Treatment Plant. After the water has been filtered, it is disinfected. Disinfection follows filtration.

07/03/18. Laboratory Water and Water Purification Systems. Water in the Laboratory. Sources of Water and Water Contamination. Contaminants in Water

CHALLENGES ASSESSING AND TREATING WASTEWATER FROM BIOTECHNOLOGY SCALE UP OPERATIONS

ADVANCED SEPARATION TECHNOLOGY APPLICATION FOR NOM REMOVAL FROM A FRESHWATER SUPPLY

Polymer Applications Understanding Polymer Activation. Presented by Rich Hopkins February 15, 2011

Organic Polymer Feeding

Several advances have been made since

Feed. Figure 1. The above image depicts the construction of a typical spiral wound element.

ECOTAN SERIES. Natural Based Coagulants

ENVIRONMENTAL ENGINEERING. Chemical Engineering department

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

CCGT/HRSG WATER CHEMISTRY COURSE OUTLINE

COMBINING PAC AND HAOPS IN A MICROGRANULAR ADSORPTIVE FILTRATION PROCESS. Abstract. Introduction

Drillox Technology. Technology Covered by Patent Application

Membrane for water reuse: effect of pre-coagulation on fouling and selectivity

INDBOND 3000 Dry Strength Resin for Paper

Water Membrane Processing Solutions. Reverse Osmosis

Carbonate Chemistry Applied to the Beverage Production of Still Water

Delvin DeBoer, Ph.D., PE. MN/ND/SD SWTW April 29, 2014 OUTLINE

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

BASU. Healthcare. Knowledge brings the greatest benefit

L-17 Coagulation and Flocculation Part-I. Environmental Engineering-I

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Conducting Polymer /TiO 2 Photocatalytic Nanocomposite for Wastewater Treatment

Coagulant Overview. Tom Coughlin Chemtrade 2015

Biocides, additives and chemical solutions. Company introduction, 2013

REMOVAL OF REACTIVE YELLOW DYE USING NATURAL COAGULANTS IN SYNTHETIC TEXTILE WASTE WATER

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Copyrighted Material ~ All Rights Reserved Course Materials for NEHA-CERT Course SP0703 Page 1

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Frequently asked question about our new Platinum Water Ionizer

HBeAg and HBeAg Ab ELISA Kit

Estimate the extent of concentration polarization in crossflow filtration Select filtration unit operations to meet product requirements, consistent

Wastewater Treatment Plant Chemical Perspectives. Presented By: Brian Villacorta, P.E., BCEE Los Angeles County Sanitation Districts

Santa Monica College Chemistry 11

TECHNOLOGIES THAT TRANSFORM POLLUTANTS TO INNOCUOUS COMPONENTS: CHEMICAL AND PHYSICOCHEMICAL METHODS

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Ashland Chemicals. Membrane Autopsy Report. Completed for: March 2012 WO#

Thermal Polyaspartate as a Biodegradable Alternative to Polyacrylate and Other Currently Used Water Soluble Polymers

When you partner with Kemira you work with a solutions provider with the world s largest supply of inorganic coagulants.

Procedures for Preparing Reagents and Media used in Firearm and Tool Mark Examinations

Chlorine, Free and Total, High Range

DR/4000 PROCEDURE. IRON, Total

CEE 371 Water and Wastewater Systems

Unit B Analysis Questions

M.A. Javeed 1, K. Chinu 1, H.K. Shon 1 and S. Vigneswaran 1,* Abstract

Nelson Environmental Technologies, Inc. ( Chlorine and Chlorine Monitoring 2011 November 8

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Physical Separations and Chromatography

Chemistry & Technology of Sanitizers

PRETREATMENT TECHNICAL DATA SHEET IRON PHOSPHATE CLEANER COATER / CONVERSION COATING PRODUCT DESCRIPTION

What Do You Think? Investigate GOALS. Part A: Precipitation of Calcium

Guide to ph Analysis.

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

Reuse of Produced Water for Electrolytic Oxidant Production: Challenges and Solutions

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

arium Water Purification Terms

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Chlorine dioxide at your convenience. By Ralph Berdin, Brenntag Nordic February 2016

Water Quality - Condensed Version 1999

equipment used commercially in processing these Materials, Inc. s direct control. THE SELLER MAKES NO reliable, but no representations, guarantees or

5. SEPARATION OF MIXTURES, PURIFICATION OF SOLIDS Objectives

CALCIUM CHLORIDE (HT Fines 94-97%)

Glossary of Common Laboratory Terms

CT4471 Drinking Water 1

Science of Chloramination. Maine Water Utilities Association June 8, 2010

Technical Resource Package 1

THE DIAL PROFESSIONAL DUO DISPENSER

Projects Involving Nanotechnology at The Oxford Centre for Sustainable Water Engineering. Dr Nick Hankins

Investigating the effect of graphene oxide on scaling in thin-film composite polyamide reverse osmosis membranes

Soil Sample Preparation Protocol (Modified from Faegri and Iversen 1 ; Moore and Webb 2 protocols)

PRETREATMENT TECHNICAL DATA SHEET IRON PHOSPHATE CONVERSION COATING PRODUCT DESCRIPTION

Trihalomethane Formation Potential (THMFP)

What is physical treatment? What is chemical treatment?

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

NECi Nitrate Kits FAQs

Name Partner Lab Section M Tu W Th F Chemistry 130 Experiment 6: Titration and Analysis

CHEMICAL OXIDATION. The use of oxidizing agents without the need of microorganisms for the reactions to proceed

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Technical Data Sheet Tersil COR

Analysis and Steps to Mitigate Heat Exchanger Fouling in an Aromatics Plant

Optimizing Coagulation with the Streaming Current Meter. Chuck Veal Micrometrix Corp

PRETREATMENT TECHNICAL DATA SHEET MULTIMETAL IRON PHOSPHATE CONVERSION COATING PRODUCT DESCRIPTION

Dehydrated Alcohol. » Dehydrated Alcohol contains not less than 99.2 percent, Pharmacopeial Forum Vol. 30(5) [Sept. Oct. 2004] HARMONIZATION 1847

SECTION D.2 AMMONIA NITROGEN

A. GENERAL NOTICES. Ninth Edition, which may be abbreviated as JSFA-IX.

Transcription:

Membrane Chemicals AXEON Water Technologies features a broad range of membrane chemicals formulated to treat a variety of water conditions for commercial and industrial applications. AXEON Membrane Chemicals are formulated to be compatible with all brands and types of RO, NF, UF membranes and provide antiscaling and antifouling capabilities while being certified under ANSI/NSF standard 60 for drinking water production. AXEON Cleaners and Support Chemicals are the ideal choice for prolonging the life of membranes and obtaining a higher level of performance from the elements within the membrane system. Antiscalants: S-100, S-200 AXEON Antiscalants are a unique polymeric system designed to control a vast range of RO/UF membrane foulants, which maximizes system performance and minimizes membrane cleaning requirements. AXEON Antiscalants are environmentally safe and resistant to biological growth, which ensures product integrity and optimum performance. Control of scale at up to 100 times saturation values or higher A lower cost and maintenance alternative to water softeners High system recovery and extended membrane life NSF/FDA approved Antifoulants: F-25 AXEON Antifoulants are specially formulated for feedwaters with high potential for fouling by colloidial particles, organic matter and silt. These Antifoulants are designed for sea and brackish surface waters that contain high levels of organic matter. Designed to reduce the amount of bacteria and fouling within the membranes Can be used as a pre treatment option to control membrane fouling Environmentally friendly and food grade Membrane Cleaners: C-10, C-20 AXEON features a robust offering of membrane cleaners designed to safely and effectively remove membrane foulants from thin film composite or cellulose acetate membranes. Ideal for prolonging the life of membranes and obtaining a higher level of performance from the elements Formulated to counteract a variety of foulants Substantial cost savings on replacement membranes Support Chemicals: M-100 AXEON also provides a variety of support chemicals to further preserve and protect the life of a system or membrane. Preservative and storage chemicals are ideal for preventing microbiological growth and freezing within membrane elements during storage. Protects against microbiological growth Protects against freezing Non-hazardous, environmentally safe

S-100 Antiscalant AXEON S-100 Antiscalant is a highly effective antiscalant, specially formulated for feedwaters with the highest levels of metal oxides, silica and scale-forming minerals. It is effective over a wide range of concentrations, and does not flocculate dissolved polymers such as residual coagulants, iron or aluminum rich silica. Use of this product is recommended for reducing the operating and capital costs of reverse osmosis (RO), nanofiltration (NF) and ultrafiltration (UF) systems. A special utility is in its application as a substitute for pretreatment with ion exchange beds. Effective in retarding polymerization and precipitation of silica Effectively controls inorganic scales over a large concentration range. Certified under ANSI/NSF Standard 60 for drinking water production. Compatible with major manufacturer s RO, NF, and UF membranes. Does not flocculate dissolved iron/aluminum oxide/silica complexes. Effective in controlling calcium carbonate and calcium sulfate scales. Effective in feedwaters with ph range 5.0 10.0 Efficacious for controlling aluminum, iron and heavy metal salts. Technical Specifications Liquid* Appearance: Clear, colorless ph: 1.5 ± 0.8 Specific Gravity: 1.08 ± 0.05 Powder* Appearance: Colorless ph (1% in water): 11 12 AXEON S-100 Antiscalant should be injected into the feedstream prior to the static mixer and cartridge filter. Effective ph range is 5 10. If frozen, may be thawed and mixed before use. Stability is excellent, but best used within 12 months. In the useful dosage range of 1 15 mg/l (neat), S-100 controls a wide range of inorganic scales at up to 100 x saturation values or higher is possible. By monitoring the concentrate stream and trend charts, optimal dosage can be achieved for the control of scales including that from calcium carbonate, calcium sulfate, barium sulfate, strontium sulfate, iron hydroxide, aluminum hydroxide and silica. Packaging Liquid: Pails and drums Powder (concentrate): Totes

S-200 Antiscalant AXEON S-200 Antiscalant is a highly effective antiscalant, specially formulated for feedwater with the highest levels of metal oxides, silica and scale-forming minerals. It is effective over a wide range of concentrations, and does not flocculate dissolved polymers such as residual coagulants, iron or aluminum-rich silica. Use of this product is recommended for reducing the operating and capital costs of reverse osmosis (RO), nanofiltration (NF) and ultrafiltration (UF) systems. It inhibits polymerization of reactive silica, and disperses colloidal (non-reactive) silica. Effective in retarding polymerization and precipitation of silica Effectively controls inorganic scales over a large concentration range. Certified under ANSI/NSF Standard 60 for drinking water production. Compatible with major manufacturer s RO, NF, and UF membranes. Does not flocculate dissolved iron/aluminum oxide/silicate complexes. May be used diluted or undiluted. Effective in feedwaters with ph range 5.0 10.0 Particularly efficacious for controlling coagulation of colloidal silica by aluminum, iron and heavy metal salts. Technical Specifications Liquid* Appearance: Clear, colorless ph: 1.5 ± 0.8 Specific Gravity: 1.08 ± 0.05 Powder* Appearance: Colorless ph (1% in water): 11 12 AXEON S-200 Antiscalant should be injected into the feedstream prior to the static mixer and cartridge filter. Effective ph range is 5 10. If frozen, may be thawed and mixed before use. Stability is excellent, but best used within 12 months. In the useful dosage range of 1 50 ppm, S-200 controls a wide range of inorganic scales along with reactive and nonreactive silica at high levels. By monitoring the concentrate stream and trend charts, optimal dosage can be achieved for the control of silica gels and scales, which form chemically linked foulants prone to flocculation with organic materials. Packaging Liquid: Pails and drums Powder (concentrate): Totes

F-25 Antifoulant AXEON F-25 Antifoulant is a highly effective anticoagulant and antifoulant for all membrane systems treating feedwaters with high potentials for fouling by silt, organics, colloids and fine particulates. It is effective over a wide range of concentrations, and does not flocculate dissolved polymers such as residual coagulants, iron or aluminum-rich silica. A special utility of AXEON F-25 Antifoulant is in its application as an anti-deposition agent for colloidal matter in sea and brackish surface waters, and industrial and municipal wastewaters. It prevents the coagulation and subsequent membrane fouling by colloidal organic matter which includes humic acid, lignin, tannin, microorganisms, polysaccharides, lipids, proteins, cellular debris and organic polymers from water treatment and inorganic colloids including silica, clay, silt, sulfur and various microcrystalline precipitates. Inhibits coagulation and deposition of organic and inorganic colloidal particles. Reduces requirements for membrane cleaning by decreasing the rate of membrane fouling. Effectively reduces membrane fouling when processing waters with high SDI values. Certified under ANSI/NSF Standard 60 for drinking water production. Eliminates the need for additional expensive pretreatment equipment and chemicals to control feedwaters with high SDI values. Compatible with major manufacturers RO, NF, and UF membranes. Compatible with simultaneous administration of antiscalants into feedwaters. Technical Specifications Liquid* Appearance: Amber clear liquid ph: 7 9 Specific Gravity: 1.02 ± 0.15 Powder* Appearance: Tan colored powder ph (1% in water): Approx. 7 F-25 Antifoulant should be injected into the feed-stream prior to the static mixer and cartridge filter. Effective ph range is 2 14. If frozen, may be thawed and mixed before use. Stability is excellent, but best used within 12 months. In the useful dosage range of 1 100 ppm neat (liquid), and 0.3 33ppm (powder), the liquid being 33% w/w of the powder in water. By monitoring the concentrate stream and trend charts, optimal dosage can be achieved for the control of colloidal particles in feedwater of microbial, plant or inorganic origins, and organic compounds in industrial process or waste streams. Packaging Powder: Custom sizes, 50 lbs, 100 lbs. Liquid: Custom sizes, 5 gallons, 55 gallons MKTF-188

C-Series Cleaners AXEON C-Series Cleaners are heavy duty action cleaners that quickly and easily mix with water to make an easy to use cleaning solution that safely and effectively remove a wide range of membrane foulants from polyamide thin film (TF), cellulose acetate (CA) and ultrafiltration (UF) membrane elements. AXEON C-Series Cleaners Product For Removing Membrane Types Solution ph C-10* Calcium Carbonate Scale TFC, CA and UF 2 SYMPTOMS OF CALCIUM CARBONATE SCALE INCLUDE: Scale extruding out of the downstream end of the last membranes in the system. All of the scale dissolves when introduced to a dilute hydrochloric acid solution. Poor salt rejection, low flow, and or, high pressure differential on individual membrane test data. 8 x 40 Element weight exceeds 45 pounds. Site reports interruption in the antiscalant or acid injection. Site reports scale in the last vessel or piping of the concentrate stream. TESTING FOR CALCIUM CARBONATE SCALE: Calcium carbonate scale is not always white. However, a quick test can be conducted to see if the foulant is comprised solely of calcium carbonate. In a glass beaker, make a 1:1 dilution of HCl and DI water. Drop a small sample of the foulant into the solution. If the foulant contains calcium carbonate, it will bubble. Continue adding acid until the bubbling stops or until the scale disappears. If the beaker contains residual material after the bubbling has stopped, then the foulant consists of more than just calcium carbonate. C-20* Organics TFC and UF 11 SYMPTOMS OF BIOLOGICAL FOULING INCLUDE: Visible slime on the feed side of the membrane. Site reports slime in the cartridge filter housing and piping. Site reports high pressure differential in the first array. Odor Individual membrane test data reports high pressure differentials. Membranes are telescoped. STEPS TO PREVENT BIOLOGICAL FOULING INCLUDE: Properly dose sodium bisulfite. Clean and sanitize the pretreatment equipment and piping. Consider an intermittent biocide treatment. Evaluate the necessity of a continuous injection biocide.

M-100 Membrane Preservative AXEON M-100 Membrane Preservative safely prevents microbiological growth within membrane elements and in membrane systems during long and short-term storage. AXEON M-100 Membrane Preservative For Removing Membrane Type Mixing Ratio ph Microbiological growth within membrane elements and systems during storage Thin film composite, cellulose acetate, ultrafiltration 1 pound AXEON M-100 to 6 gallons water Medium / Low AXEON M-100 safely and effectively prevents microbiological growth within membrane elements and systems during long- and short-term storage. It replaces the use of sodium metabisulphite and other chemicals that are typically used. While sodium bisulfite can be hazardous or unstable, M-100 is effective long-term and does not create environmental or health risks. AXEON M-100 is compatible with all membrane types and rinses easily from membranes. AXEON M-100 is packaged as a dry, stable, nonreactive powder for ease of transportation and storage. Procedures In Storage 1. Clean the membranes with AXEON C10 or C20 Cleaners prior to storage. Using good quality water (RO product water), mix at a ratio of one pound M-100 to 6 gallons of water. 2. Recirculate storage solution at low pressure (less than 60 psig) through membranes for minimum of 15 minutes. 3. After re-circulation, shut system down making sure storage solution does not drain out of membranes. Container Storage 1. Clean membranes with AXEON C10 or C20 Cleaners. 2. Using good quality water (RO product water), mix a ratio of one pound M-100 to 6 gallons of water. Place membranes in storage container containing M-100 solution. 3. After storage, place membranes in system and rinse with good quality water for 30 minutes prior to system start-up. 4. After storage, rinse membranes with good quality water for 30 minutes before system start up.