SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Similar documents
SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

Total Organic Carbon, Total Nitrogen

Fusion UV/Persulfate TOC Analyzer

Fusion UV/Persulfate TOC Analyzer

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:

University Wet Chemistry Analyzer Packages

DMA-80L TECHNICAL SPECIFICATIONS

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Advanced technics in the. (TIC/TOC/TNb)

APPRENTICESHIP AT SKALAR S LABORATORY. The organization Skalar Analytical BV. The product lines of Skalar Analytical BV

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Basic Digestion Principles

DI 3500 Discrete Aoalvzer

The solution for all of your

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

2. Pharmaceutical industry

ISO 8245 INTERNATIONAL STANDARD. Water quality Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)

Mercury Stack Monitor SM-4

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

The art of elemental analysis

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

SMARTCHEM 140. DIRECt READ DISCREtE ANAlyZER FOR SIMPlE AND AUtOMAtED CHEMIStRIES

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Examining the Role of TOC Analyzers in the Pharmaceutical Laboratory

The Elzone II Particle Count and Size Analyzer

Hydra-C Application Note: 1076

AFT. Advanced Friction Tester. Static and dynamic coefficient of friction Fast, repeatable measurements Compliant to multiple standards

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

Automating Wet Chemical Analysis

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

110 Lowell Rd Hudson, NH USA Tel:

LCTech GmbH Chromatographie

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Perseverance. Experimentation. Knowledge.

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Oxygen Demand, Chemical

Oxygen Demand, Chemical

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

Simplifying the Process: Automated USP 643 / EP

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Freezing point osmometry

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

The ultimate in desktop particle characterization

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Kjeltec 2300 Analyzer Unit

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

Freezing point osmometry

OXITEST Oxidation Test Reactor

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

RS-C Flexible Reticle Stocker

The first address for Titration. TITRONIC 300 and TitroLine 5000

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Rapid Catalyst Screening Reactors

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

novaa 800 D Atomic Absorption Spectrometer

Application field / Industry branch:

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

ActiPix SDI300 Surface Dissolution Imaging System

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

Phosphate total LR TT mg/l P b) Phosphomolybdenum Blue

RS 1700/1900/2300/2900 High Density Reticle Stockers

RH7-D & RH10-D CAPILLARY RHEOMETERS

Shorten your Time-to-Result

SIFT-MS. technology overview

lems. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement task.

Gamma Analyst Performance Characteristics (MDAs)

Speed and flexibility

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

5. TOC in daily practice

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Fast and effective. quality monitoring for breweries. Thermo Scientific Gallery Plus Beermaster

2. Pharmaceutical industry

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

Transcription:

SKALAR your partner in chemistry automation Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Skalar s Formacs HT TOC / TN Analyzer The Formacs HT TOC/TN analyzers provide fast, reliable analysis of Total Organic Carbon (TOC) and Total Nitrogen (TN) in liquid samples using high temperature catalytic combustion. The units are designed to measure and handle the concentration of nitrogen and / or carbon fractions from various sample matrices. The instrument is supplied customized for the sample type and optimized from a range of different catalysts and operation temperatures allowing the analysis of all carbon and nitrogen fractions present in the sample. The fractions can be measured sequentially or simultaneously with automated sample pretreatments such as acidification and purging. A variety of options and accessories are available, including the Primacs MCS add-on module for carbon determination in solid materials, the ND25 Total Nitrogen detector and the possibility of measuring nitrates and nitrites to provide a true Kjeldahl alternative. The Formacs HT analyzer meets the latest requirements for any laboratory from low level up to extended high concentration ranges. Applicable for: Drinking water Waste water Surface water Sea water High saline waters Process control Pharmaceutical industry Soil extracts Others

Principle of operation The Formacs HT Analyzer measures Total Organic Carbon (TOC) by analyzing the Total Carbon (TC) and the Total Inorganic Carbon (TIC). Total Carbon (TC) is obtained by injection of the sample into a high temperature combustion furnace. TC is converted to carbon dioxide at temperatures up to 950 C by catalytic oxidation. The carbon dioxide formed is subsequently dispersed into the carrier gas and the CO 2 concentration is measured by a non-dispersive infrared detector (NDIR). Total Inorganic Carbon (TIC) is determined by injecting the sample into a reactor containing acid, converting inorganic carbon to carbon dioxide. The NDIR measures the carbon dioxide concentration formed during acidification. The TOC is calculated by automatically subtracting the TIC from the TC. In addition, Non Purgeable Organic Carbon (NPOC) can be measured by automatic acidification and purging of the sample. Total Inorganic Carbon (TIC) and the Purgeable Organic Carbon (POC) are removed. NPOC remains in the sample and can be measured directly by injecting the sample into the high temperature combustion furnace. The NPOC equals the TOC if the POC concentration is insignificant (TOC = NPOC + POC). Optional the removed POC can be measured. The Formacs HT analyzer can be operated as standalone analyzer. A random access auto sampler is available for complete automation. The auto sampler allows homogenization and acidification & purging of the following sample while analyzing the current one, which saves valuable analysis time. The NPOC sample pretreatment is fully controlled by the software and auto sampler, this pretreatment can be set in a preferred mode by the operator. Carbon Fractions Particulate Carbonates TIC Total Inoganic Carbon Features Dissolved CO2 TC Total Carbon POC Purgeable TOC Total Organic Carbon NPOC Non Purgeable Stand-alone TOC operation or with auto-sampler Homogenization by automated stirring (rod or magnetic) Robust rotary septumless injection ports Integrated Peltier cooler for optimum moisture removal Large variety of vial sizes including septum-closed vials Allows a true system blank analysis Method according to EPA 415.1, Standard Methods 5310B, DIN 38409 H3, ASTM D-5173, USP <643>, EU 2.2.44, ISO 8245, EN 1484, USEPA 9060A

TN & TKN analysis The ND25 detector can be added to the Formacs HT Analyzer for Total Nitrogen (TN) analysis. A wide concentration range of TN can be measured with high accuracy in a short analysis time using chemiluminescence detection (CLD). The sample is injected into the high temperature furnace where it is catalytically combusted. Oxidative pyrolysis causes the chemically bound nitrogen to be converted to nitric oxide (NO). In the ND25 detector, nitric oxide (NO) reacts to form metastable nitrogen dioxide. The photons emitted from the rapid decay of the metastable nitrogen dioxide are detected by a photomultiplier tube. The Formacs HT analyzer also provides a unique cost-effective and safer alternative for Total Kjeldahl Nitrogen (TKN) analysis, by an integrated NN-reactor for the analysis of NO 3 + NO 2 (NN). The TKN value is determined in two steps, i.e. the analysis of Total Nitrogen (TN) and the analysis of NO 3 + NO 2 via chemical reduction, where NO 3 and NO 2 are reduced to nitric oxide (NO) and detected via CLD detection. The TKN value is obtained automatically by subtraction: TKN = TN NN. This unique alternative method of TKN analysis results in a very fast analysis time (5 min.), and eliminates the use of hazardous digestion acids. The Formacs HT TOC/TN analyzer combines the automation of TOC, TN and TKN all in one system. Features Nitrogen Detector NO 2 and NO 3 Reactor Simultaneous TOC and TN measurements CLD detector for analysis of TN and NO 2 + NO 3 Excellent alternative for Total Kjeldahl Analysis Low detection limits Fast analyses using no hazardous reagents No sample preparation required Wide dynamic range Low maintenance unit Method according to EN 12260, ISO 11905-2, ASTM D5176-91, DIN 38409 H27

Primacs MCS TOC module for solid samples The Primacs MCS add-on module is designed for analyzing solid materials and operates in combination with the Skalar Formacs series liquid sample TOC analyzers, offering an economical solution for laboratories handling a large variety of sample matrices. The unit consists of two integrated reactors for both Total Carbon (TC) and Total Inorganic Carbon (TIC) analysis without any sample preparation. The TC is determined by catalytic oxidation of the sample at 1100 C, which converts the carbon to CO 2. TIC is determined by acidification of the sample in a separate reactor, which converts inorganic carbon to CO 2. The Primacs MCS uses the multi-range NDIR detector of the Formacs series for the detection of CO 2. The Primacs MCS analyses TC, TIC and TOC. The software calculates the TOC concentration of the samples by subtraction - (TC - TIC = TOC). Features Automatic balance interfacing Sample weights up to 3 grams Range of 1 mg to 40 mg absolute carbon Unique vertical sample introduction system Reusable quartz sample crucibles Economical concept Requires minimal bench space Integrated TC and TIC reactors No sample pretreatment required Method according ISO 10649, ISO 13137, EN 13639, EPA 415.1, ASTM D-2579 US EPA 9060A

The Formacs analyzers come with an easy, intuitive operable and flexible data acquisition and instrument control software package. Different access levels are available to prevent unauthorized operation. In templates the analysis sequence can be defined allowing the selection of injection volume, type of analysis (TC, TIC, TOC, NPOC, TN and NN), stirring, and acidification & purging. Samples and standards can be set individually as they may vary, or can be entered as a group batch method. Valuable operator time can be saved by using the unique feature of automatic preparation of working standards and pre- and post dilution of overrange samples. During the analysis the real-time peak information and results are displayed in multiple view screens. When Carbon and Nitrogen are analyzed simultaneously, the realtime graphics either provides visualization for both analyses or individually. Results are automatically calculated during the analysis. Multiple calibration curves can be stored for calculation. The software automatically selects the bestfitting curve. When priority samples need to be analyzed the sample table can be expanded and edited during analysis. Parallel to the running analysis it is possible to open other analysis runs for editing/viewing purposes. TOC & TN Software HTAccess includes excellent Quality control features. QC samples can be analyzed and Quality control charts together with other valuable statistical information can be created. The software complies also with CLP protocols ensuring accuracy and precision of analytical results. Analysis results can be exported to LIMS or Excel, including the statistical data of the analysis such as the calibration curve, CV values and average concentrations. Export and print layouts can be customized by the user. Software Features Automatic preparation of working standards Automatic pre- and post dilution of overrange samples Possibility of opening multiple analysis runs All information of a sample in one single view Possibility of using Quality samples and creating Quality Control Charts Contract Laboratory Protocol (CLP) compliant. User definable concentration limits for the different CLP samples and required actions (up to 4) Possibility of exporting results during analysis Windows 7 compatible 21CFR part 11 compliant BOD/COD calculation possible via TOC analysis Remote signal monitoring

Other Skalar TOC & TN Analyzers Liquid Samples Formacs HT-I TOC Analyzer The Formacs HT-I TOC/TN analyzers provide fast, reliable analysis of Total Organic Carbon (TOC) and Total Nitrogen (TN) in liquid samples by direct sample injection in a high temperature catalytic combustion furnace. The units are especially designed for particulate laden samples (suspensions), but can handle the concentration of nitrogen and/or carbon fractions from various other sample matrices. Solid Samples Primacs SNC-100 TOC - TN / Protein Analyzer The Primacs SNC-100 is a flexible solid sample analyzer with integrated 100-position autosampler for determination of Nitrogen (N)/Protein, Total Carbon (TC), Total Elemental Carbon (TEC), Total Inorganic Carbon (TIC) and Total Organic Carbon (TOC). The analyzer provides fast, accurate and low level analysis for these parameters in applications such as soil & plant, sludges & sediments, animal feed & grain, food, malt, fertilizer etc. Primacs MCS TOC Analyzer The Primacs MCS TOC analyzer provides Total Organic Carbon analysis on solid materials. The analyzer is designed as an add-on module and operates in combination with the Formacs HT TOC analyzer. It allows for the analysis of TC, IC and TOC.

Contact Skalar USA Headquarters Skalar, Inc. 5012 Bristol Industrial Way # 107 Buford, GA 30518 Toll Free: 1 800 782 4994 Tel. + 1 770 416 6717 Fax. + 1 770 416 6718 Email: Info@skalar-us.com Germany Skalar Analytic GmbH Gewerbestraße Süd 63 41812 Erkelenz Tel. + 49 (0)2431 96190 Fax. + 49 (0)2431 961970 Email: info.germany@skalar.com Skalar s Headquarters Skalar Analytical B.V. Tinstraat 12 4823 AA Breda The Netherlands Tel. +31 (0)76 5486 486 Fax. +31 (0)76 5486 400 Email: info@skalar.com Internet: www.skalar.com ISO 9001 Certified ISO 14001 Certified Canada Skalar, Inc. Unit # 200, 270 Orenda Road Brampton, L6T 4X6 Toll Free: 1 800 782 4994 Tel. + 1 770 416 6717 Fax. + 1 770 416 6718 Email: Info@skalar-us.com France Skalar Analytique S.A.R.L. 35-37, rue Berthollet 94110 Arcueil Tel. + 33 (0)1 4665 9700 Fax. + 33 (0)1 4665 9506 Email: info.france@skalar.com United Kingdom Skalar (UK) Ltd. Breda House, Millfield Industrial Estate Wheldrake, York, YO19 6NA Tel. + 44 (0)1904 444800 Fax. + 44 (0)1904 444820 Email: info.uk@skalar.com For more information please contact your local Skalar agent or Skalar s headquarters in the Netherlands Copyright Skalar 2015 Publication No. 0404002F.US Asia / Middle East Skalar Analytical India Pvt. Ltd. No. 7/4, Pappathiammal Street Jain Colony, Kodambakkam Chennai - 600024 - India Tel. + 9144 2483 7007 Fax. + 9144 2483 6006 Email: info.skalarindia@skalar.com Skalar reserves the right to change the specifications and the appearance of the equipment without further notification.