DYNAMIC MECHANICAL ANALYZER DMA 2980

Similar documents
D Y N A M I C M E C H A N I C A L A N A L Y S I S A N D I T S A D V A N T A G E S O V E R D E F L E C T I O N T E M P E R A T U R E U N D E R L O A D

Dynamic Mechanical Analysis of Solid Polymers and Polymer Melts

Mechanical properties of polymers: an overview. Suryasarathi Bose Dept. of Materials Engineering, IISc, Bangalore

Viscoelasticity, Creep and Oscillation Experiment. Basic Seminar Applied Rheology

Abvanced Lab Course. Dynamical-Mechanical Analysis (DMA) of Polymers

BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test

Inverted Pendulum System

MATERIAL MECHANICS, SE2126 COMPUTER LAB 3 VISCOELASTICITY. k a. N t

DEVELOPMENT OF IMPROVED METHODS FOR CHARACTERISING THE CURE OF COMPOSITE MATERIALS

2: SIMPLE HARMONIC MOTION

FAVIMAT (AI)ROBOT2 FAVIGRAPH. Automatic Single-Fibre Testers

CONSISTENCY OF RHEOLOGICAL EXPERIMENTS FOR PSA CHARACTERIZATION

APPLICATIONS OF THERMAL ANALYSIS IN POLYMER AND COMPOSITES CHARACTERIZATION. Wei Xie TA Instruments

(Refer Slide Time: 00:58)

Modelling of viscoelastic properties of a curing adhesive

Measurement Engineering Group, Paderborn University, Warburger Straße 100, Paderborn, Germany

Characterisation Programme Polymer Multi-scale Properties Industrial Advisory Group 22 nd April 2008

SHM Simple Harmonic Motion revised May 23, 2017

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

Mechatronics II Laboratory EXPERIMENT #1 MOTOR CHARACTERISTICS FORCE/TORQUE SENSORS AND DYNAMOMETER PART 1

Elastic Properties of Solids (One or two weights)

2: SIMPLE HARMONIC MOTION

Understanding Frequency Domain Viscoelasticity in Abaqus

MEMS Report for Lab #3. Use of Strain Gages to Determine the Strain in Cantilever Beams

Dynamic Mechanical Analysis (DMA) of Polymers by Oscillatory Indentation

MAKING THE MOST OF THE VNC

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

The 2S2P1D: An Excellent Linear Viscoelastic Model

Reliable Test Results

Atomic Force Microscopy imaging and beyond

Characterisation of the mechanical behaviour of a polyurethane elastomer based on indentation and tensile creep experiments

Rotational Motion. Figure 1: Torsional harmonic oscillator. The locations of the rotor and fiber are indicated.

Introduction. Pre-Lab Questions: Physics 1CL PERIODIC MOTION - PART II Fall 2009

1.105 Solid Mechanics Laboratory Fall 2003 Experiment 3 The Tension Test

High Tech High Top Hat Technicians. An Introduction to Solid Mechanics. Is that supposed to bend there?

L13 Structural Engineering Laboratory

Workshop 8. Lateral Buckling

(Refer Slide Time: 1: 19)

Introduction. Pre-Lab Questions: Physics 1CL PERIODIC MOTION - PART II Spring 2009

Experiment Five (5) Principal of Stress and Strain

For an imposed stress history consisting of a rapidly applied step-function jump in

Determination of Glass Transition Temperature of Double-Base Rocket Propellants with the Use of Dynamic Mechanical Analysis

Excerpt from the Proceedings of the COMSOL Conference 2010 Boston

EXPERIMENTALLY DETERMINING THE VISCOELASTIC BEHAVIOR OF A CURING THERMOSET EPOXY R. Thorpe 1, A. Poursartip 1*

MSC Elastomers Seminar Some Things About Elastomers

LAB 2 - ONE DIMENSIONAL MOTION

Figure 1. Dimension of PSA in face paper laminate

Roark s Formulas for Excel Superposition Wizard

Application Note. No. 51. Visualization of Progress of Internal Damage in Carbon Fiber Composite Materials and Mechanism of Impact Strength

Flexural properties of polymers

Difference Between Fixed and Floating Reference Points AASHTO T-321

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

Testing and Analysis

Ablaos Asphalt Binder Large Amplitude Oscillatory Shear

AERO 214. Lab II. Measurement of elastic moduli using bending of beams and torsion of bars

A New Methodology for Fiber Optic Strain Gage Measurements and its Characterization ABSTRACT

Determination of Activation Energy for Glass Transition of an Epoxy Adhesive Using Dynamic Mechanical Analysis

Periodic table with the elements associated with commercial polymers in color.

Finite Element Modelling with Plastic Hinges

Determining thermal noise limiting properties of thin films

March 24, Chapter 4. Deflection and Stiffness. Dr. Mohammad Suliman Abuhaiba, PE

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Response Spectrum Analysis Shock and Seismic. FEMAP & NX Nastran

Improved stress prediction in adhesive bonded optical components

TA INSTRUMENTS THERMOMECHANICAL ANALYZER

Lecture 7 Constitutive Behavior of Asphalt Concrete

Representations of Motion in One Dimension: Speeding up and slowing down with constant acceleration

SIZE EFFECTS IN THE COMPRESSIVE CRUSHING OF HONEYCOMBS

Finite Element Analysis of Piezoelectric Cantilever

OPTIMISING THE MECHANICAL CHARACTERISATION OF A RESILIENT INTERLAYER FOR THE USE IN TIMBER CON- STRUCTION

ε t increases from the compressioncontrolled Figure 9.15: Adjusted interaction diagram

Coupled Oscillators. 1 Introduction. 2 Theory. PHY 300 Lab 2 Fall 2012

Application Note #3413

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

STRUCTURAL ANALYSIS OF THE LIFTING DEVICE DETECTOR SUPPORTS FOR THE LHCb VERTEX LOCATOR (VELO)

EFFECT OF SOY PROTEIN AND CARBOHYDRATE RATIO ON THE VISCOELASTIC PROPERTIES OF STYRENE-BUTADIENE COMPOSITES

BIAS EXTENSION TEST STANDARD

NOTE To improve the TA to class ratio, two groups will perform this experiment at one time. Group times are listed on the class website.

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

Conservation of Momentum

MECHANICS LAB AM 317 EXP 3 BENDING STRESS IN A BEAM

Guideline for Rheological Measurements

Torsion/Axial Illustration: 1 (3/30/00)

MSE 383, Unit 3-3. Joshua U. Otaigbe Iowa State University Materials Science & Engineering Dept.

MAAE 2202 A. Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

Strain Measurements. Isaac Choutapalli

MAE106 Laboratory Exercises Lab # 6 - Vibrating systems

Members Subjected to Torsional Loads

Experiment Two (2) Torsional testing of Circular Shafts

Lab 2: Static Response, Cantilevered Beam

THE MATRIX: EVOLUTIONS II

An Experimental Investigation of the Elastic and Viscoelastic Properties of Small

Activity P15: Simple Harmonic Oscillation (Force Sensor, Photogate)

Lab 1: Damped, Driven Harmonic Oscillator

The Rheology Handbook

EXPERIMENT 7: ANGULAR KINEMATICS AND TORQUE (V_3)

AE3610 Experiments in Fluid and Solid Mechanics TRANSIENT MEASUREMENTS OF HOOP STRESSES FOR A THIN-WALL PRESSURE VESSEL

REPORT DOCUMENTATION PAGE

3.032 Problem Set 4 Fall 2007 Due: Start of Lecture,

Transcription:

Prepared by Russell R. Ulbrich Sujan E. Bin Wadud DYNAMIC MECHANICAL ANALYZER DMA 2980 Getting Started Guide for Thermal Advantage Users TABLE OF CONTENTS Mearurement Principles of the DMA 2980 1 Force and Amplitude 2 Sample Stiffness and Modulus Calculations 4 Static Force and Force Track 7 Choosing Parameters for Temperature Ramp Scan in Dynamic Mode 8 Real-Time Signal Display 10 Measuring the Linear Viscoelastic Region of a Material 11 Measurement Principles of the DMA 2980 The DMA 2980 is a stress (force) controlled instrument. This is initially confusing to new users because when we program the DMA 2980 we enter an amplitude (strain) as our commanded parameter. A generic schematic of a controlled stress DMA is shown below. A controlled stress DMA is composed of a motor, which applies force (stress) to the sample, and a displacement sensor that measures the amplitude (strain). Fig 1. Schematic diagram of the DMA 2980. Sample Displacement Sensor - Measures Strain Motor Applies Force (Stress) When programming the instrument, we request a deformation in the form of amplitude. The instrument simply applies force (its control parameter) until it measures the amplitude that we requested. It s that simple An example of a typical measurement over a wide temperature range is shown in Fig. 2. Note that the measured amplitude (strain) is constant throughout the test. The controlled force variable changes as the stiffness of the sample changes to keep the amplitude constant.

Fig 2. Changing stiffness of the material with temperature at a fixed strain. Stiffness, K Measured strain (programmed) Stress (Instrument Control Variable) Temperature Force and Amplitude Now that you know how the DMA2980 makes a measurement, you need to understand some of the basic specifications of the instrument. The DMA 2980 is stress or FORCE controlled. This means is that the motor can apply any force within the range of its specifications. The DMA 2980 uses an optical encoder to measure displacement. This means that the amplitude you command must be within the minimum and maximum measurement limits of the optical encoder. Things to Know The instrument controls force. The force range of the instrument is 0.0001 N to 18 N. The instrument measures strain. The amplitudes you can command in a dynamic experiment are from ± 0.5 µm to 10,000 µm. The following table gives some suggestions for starting amplitudes to use in dynamic testing for various clamps. Table 1. Recommended Starting Amplitudes for Dynamic Experiments Clamp Type Amplitude, µm Tension Film or Fiber Compression Three Point Bend Dual/Single Cantilever Shear Sandwich 15 to 25 10 to 20 25 to 40 20 to 30 10 to 20 2/16

Specialty Fiber 15 to 25 If the amplitude you request does not require at least 0.0001 N to achieve, the measurement will be out of the specification of the instrument. If force generated is below 0.001N, increase the amplitude to boost the signal. By increasing the amplitude, you are increasing the force required to deform the sample and achieve that amplitude. It is recommended that you increase the amplitude in increments of 5 to 10 microns. NOTE If amplitudes are too large, you may deform the sample outside of the linear viscoelastic region, LVER. The LVER will be discussed later. If the amplitude you request requires more than 18 N to achieve, the measurements will more than likely be fine. When the DMA 2980 is driving the full 18 N, the module will display Force Limit. Basically what happens is the sample is so stiff that the full 18 N of the DMA 2980, is not enough force to displace the sample to the requested amplitude. The measurement is not valid if the measured amplitude at full force is below the 0.5 µm limit of dynamic displacement. If the displacement is above 0.5 µm, then let the test continue. It is business as usual A schematic of this situation is depicted below. The instrument will continue to command the 18 N of force until the request amplitude is achieved. As the sample heats, the sample stiffness will decrease and the force required to drive the desired displacement will decrease. Eventually the instrument will be able to command enough force to maintain the commanded displacement. At this time the force will begin to decrease to keep the amplitude constant. Fig. 3. Stiffness and strain when Force Limit is reached. Max. Force Measured strain (programmed) Stiffness, K Stress(Instrument Control Variable) Temperature If you are not measuring at least 0.5 µm at full force of 18 N, you will need to change either the size of the sample, the clamp you are using, or both. Changing the sample size and clamp type will change the sample stiffness. 3/16

Sample Stiffness and Modulus Calculations Perhaps one of the most overlooked considerations when designing an experiment is the sample geometry, i.e. sample length, width, and thickness. Many times it is assumed that as long as the sample fits into the clamp of interest, accurate measurements can be made. For example, the Tension Film clamp of the DMA 2980 can accommodate samples up to 2 mm thick, however this does not necessarily mean that all samples of this thickness can be tested. To understand why the sample size is such an important consideration we must discuss the difference between sample modulus and sample stiffness. The fundamental measurement of the DMA 2980 is sample stiffness K. Sample stiffness is defined as the force applied to the sample divided by the amplitude of deformation (force in N/displacement in µm). The stiffness of a material is an extrinsic property that is dependent on its geometry (physical dimensions). The modulus of a material however, is an intrinsic property that is independent of its geometry. As an example, consider a piece of aluminum foil. It is very easy to bend the aluminum foil. Now take a bar of aluminum one-inch thick. This piece of aluminum is not easily bent. Both the aluminum foil and bar are made of the same material but simply changing the physical dimensions of the material changes the amount of force required to deform the material. If we were to measure the modulus of both the foil and bar, we would get the same number. Put another way, two materials of different modulus can have the same stiffness if the dimensions of the two samples are different. This concept is shown schematically in the figure to the right. After the instrument makes the fundamental measurement of stiffness, the materials modulus is then calculated. Explanations of modulus calculations for dynamic and transient measurements are as follows: Fig. 4. Stiffness vs Modulus Thick and Thin Samples Can Have The Same St iffness F = 1 High Mat eria x = 10 F = 1 x = 10 Low Modulus Thick and Thin Samples That Have The Same Modulus F = 1 x = 10 Low St iffness Sam F = 1 x = 2 High St iffness Dynamic Measurements In dynamic experiments, the DMA 2980 measures the raw signals of force, amplitude of deformation, and phase angle. Instrument calibration constants are applied to the raw signals. Force and amplitude are used to calculate the complex stiffness K* which is used with the phase angle to calculate the storage and loss stiffness (K and K ). Tan δ is calculated as the ratio of K to K. Storage and loss moduli are then calculated by multiplying the raw stiffness measurements by the appropriate geometry factors GF. 4/16

Transient Measurements In transient measurements, the DMA 2980 measures the raw signals of force and amplitude of deformation. Stress and strain are derived from the raw force and amplitude normalized for the geometry factor GF. Things to Know The stiffness range of the DMA 2980 is 100 N/m to 10,000,000 N/m. If the sample stiffness is above or below this range, you will need to change the dimensions of the sample for the clamp being used or change clamp type altogether. The stiffness is a signal that is not saved, so once a sample is loaded and the procedure has been programmed, hit the MEASURE button on the module and note the stiffness in the real-time display. The following table is a guide for increasing or decreasing sample stiffness. Table 2. Guide for changing sample stiffness. Clamp Type To Increase Stiffness To Decrease Stiffness Tension Film Decrease length or increase width. If possible increase thickness Increase length or decrease width. If possible decrease thickness. Tension Fiber Decrease length or increase diameter if possible. Increase length or decrease diameter if possible. Dual/Single Cantilever Decrease length or increase width. If possible increase thickness. Note: L/T 10 Increase length or decrease width, if possible decrease thickness. Note: L/T 10 Three-point Bending Decrease length or increase width. If possible increase thickness. Increase length or decrease width. If possible decrease thickness. Compression circular Decrease thickness or Increase diameter Increase thickness or decrease diameter. Shear Sandwich Decrease thickness or Increase length and width. Increase thickness or decrease length and width. Example The geometry factor, GF, equations and operating windows can be used to help you determine both the optimum sample size for a sample under test, and the modulus range for a particular sample size. The geometry factors and operating windows are found in Chapter 5 of the DMA 2980 Operator s Manual (P/N 984004.001). The following is an example of using an operating window and the geometry 5/16

factors to determine if a film of a particular size can be measured using the Tension Film Clamp. Fig 5. Operating Window for Tension Film Clamp of DMA 2980 Modulus (Pa ) 10 13 10 12 10 11 10 10 10 9 10 8 10 7 10 6 10 5 } Modulus Range Geometry Factor = L /A = 1 0 10 4 10-1 10 0 10 1 10 2 10 3 10 4 10 5 Geometry Factor (1 /mm) The operating window above is for the Tension Film clamp of the DMA 2980. To use the window, calculate the geometry factor using the dimensions of the sample to be tested. Strike a vertical line at the calculated geometry factor. The maximum and minimum modulus will be where the vertical line crosses at the upper and lower limits of the geometry window. The following is an example of using the geometry factors and stiffness range to calculate the modulus range for a film sample in tension film clamp: For Tension Film Clamp, GF = L/A, where L is the length and A is the cross sectional Area The sample modulus is calculated in the DMA 2980 by multiplying the measured sample stiffness, Ks, by the geometry factor, GF. Modulus = Ks x GF or Modulus = Ks x (L/A) The measurable stiffness range of the instrument is a fixed quantity between 100 to 10,000,000 N/m. It can be seen from this equation that the measurable modulus range for a given sample size can be determined by solving the equation at the minimum and maximum stiffness values. Note we can solve the modulus equation above for stiffness as follows Ks = Modulus / GF, or Ks = (Modulus _ A) / L Since the modulus of the material is an intrinsic property, i.e. independent of the sample dimensions, it can be seen that the sample dimensions must be selected to yield stiffness values within the allowable measurable range of the instrument. 6/16

Static Force and Force Track There are two basic classes of clamps tensioning and nontensioning. The tension film, tension fiber, three point bend, and compression clamps are all tensioning clamps. When using tensioning clamps, after loading the sample, the static force entered in the software will be activated when the Measure button is pressed. Force-track is used when a static force needs to be changed in accordance with any change in the sample stiffness, e.g., during a temperature ramp/sweep. But why do we need static force at all? The following describes how it can be used in the different clamps: Tension film or fiber: Applied to remove the buckle from a sample in tension so an accurate length measurement can be made. Compression: Applied to keep upper plate in contact with sample so an accurate thickness measurement can be made and improve contact between sample and plate. Three point bending: Applied to keep center fulcrum in contact with sample prior to starting any experiment, e.g., dynamic oscillation. When used without force-track, any non-zero static force entered in the software will simply maintain a constant force the sample for the duration of the test. There are no recommended starting values for static force when used alone. The only requirement is that the static force must exceed the dynamic force generated at all amplitudes and frequencies in the test chosen. But for materials such as amorphous or semi-crystaline thermoplastic polymers, application of only a static force during a temperature ramp will lead to erroneous results because at higher temperatures, where the material is softer, it may start to creep. Hence, ideally, the force on the sample would have to be changed to follow the stiffness of the sample during temperature ramps. This is exactly what force-track does. As the sample softens during a temperature ramp, the dynamic force required to achieve a certain amplitude decreases. When force-track is activated, the instrument will adjust the static load to be a set proportion of the dynamic load required to drive the selected amplitude. The ratio of static to dynamic force can be defined as a percentage by the user. The static load is always maintained higher than the dynamic load, so the force-track percentage is always greater than 100. The following table gives recommended values for static force and force track for the different tensioning clamps. Table 3. Guide for initial static force and force-track values. Clamp Type Static Force (N) Force-Track (%) Tension Film 0.01 120 to 150 Tension Fiber 0.001 A discussion of the difference between tensioning and nontensioning clamps can be found in Chapter 5 of the DMA 2980 Operator s Manual (PN984004.001) 7/16

120 Compression 0.001 to 0.1 125 Three-point Bending (Thermoplastics) 1.0 125 to 150 Three-point Bending (Stiff Thermosets) 1.0 150 to 200, or Can use constant force NOTE Minimizing the amplitude and force track percentage will minimize the risk of creep as the sample softens. Choosing Parameters for Multi-Frequency and Multi-strain Modes Frequency The frequency range of the DMA 2980 is 0.01 to 200 Hz. This is the frequency range that the instrument s motor is capable of driving, however, the upper frequency that can be applied to a sample is dependent on the stiffness of the sample. The higher the sample stiffness the easier it will be to drive the sample at higher frequencies. SINGLE FREQUENCY TEMPERATURE RAMP SCAN Unless there is a special interest in any other frequency and there is a need to run a typical temperature ramp test for determining the location of transitions in a material, the recommended starting frequency is 1 Hz, which is a benchmarked standard. The limiting factor in selecting a frequency for a test is the data collection rate. The lower the frequency, the longer it will take to collect data. This can cause very big voids in data points over a wide temperature range if the frequency selected is too low (and/or the ramp rate is too high). When running a temperature ramp scan at a single frequency, the data will be collected according to the following: First data point in the scan: t = 7/F, where F = frequency in Hz Second through last data points: t = 3/F So if you are running a 1 Hz scan, the first data point will be taken at 7 seconds into the scan and the second through the last data points will be taken every 3 second thereafter. 8/16

MULTI-FREQUENCY TEMPERATURE RAMP SCAN If you would like to run multiple frequencies during a temperature ramp you should run only two or three frequencies in a single scan. The minimum frequency in a ramp scan should be no lower than 0.5 Hz. This is because when running multiple frequencies each data point at each frequency will be taken at a time of 7/F. For example, say you are running a temperature ramp at 3 C/min and at frequencies of 0.5 Hz, 1 Hz, and 5 Hz. The total time required to scan through all three frequencies will be: t = 7/0.5 + 7/1 + 7/5 = 14 + 7 + 1.4 =22.4 seconds This scenario will give approximately three data points every degree. In essence, this translates to a data point approximately every one degree, at each frequency in the sweep. This generates more than enough data points to define the transitions smoothly. NOTE For information on running multi-frequency scans for timetemperature superposition TTS see TA-246. Temperature Ramp Rate The recommended temperature ramp rate for DMA experiments is from 1 C/min. to 5 C/min. The temperature ramp rate in a DMA experiment should not exceed 5 C/min. The choice of ramp rate will depend on the sample size, the frequency or frequencies of interest, and the desired degree of accuracy in transitions. When designing a test consider the following: The faster the heating rate, the more the sample will lag the actual temperature and transitions will be pushed to higher temperatures. Slower heating rates (1 to 3 C/min.) will give more accurate transition temperatures. If the absolute temperature of the transition is desired, then a step and hold temperature profile should be programmed. Big and thick samples, such as those used in three point bending and cantilever-bending clamps will lag the heating rate more than thin samples, such as films and fibers. The lower the frequency, the less often data will be acquired. Low frequencies (<0.5 Hz) and fast heating rates (5 C/min.) are not good combinations. Make sure data will be acquired at reasonable time intervals for the ramp rate selected (see time for data collection above). A recommended combination for a single-frequency temperature ramp is a frequency of 1 Hz and Ramp rate of 3 C/min. Real-Time Signal Display Selecting the right parameters when conducting dynamic mechanical 9/16

measurements on the DMA 2980 is very important for achieving accurate and reproducible results. What parameter whould I use is typically the most frequent question for new users. The Thermal Advantage software for the DMA 2980 is equipped with an on-line signal display that aids the user in selecting valid instrument parameters. Familiarize yourself with the signal display. Fig 6. Real-time display The real-time signal display can guide you through just about any question you may have pertaining to the validity of your experimental test set-up as long as you know your instruments limitations. After measuring sample dimensions, and mounting the sample in the appropriate clamp, press the MEASURE key on the 2980 module keypad and view the signal display. When running a dynamic experiment (multifrequency and multistrain mode) pay special attention to the following signals: Amplitude: Should achieve and maintain the value programmed. If running a multistrain experiment, this amplitude will cycle through the values programmed. It should be noted that the interpretation of the data might rely on linear viscoelastic theory in which case the data should be collected at an amplitude within the linear viscoelastic region of the material. Stiffness: Should be within instruments measurable range of 100 N/m to 10,000,000 N/m. Drive Force: Drive force should between 0.0001 N and 18 N. If the drive force is lower, increase the programmed amplitude to increase the drive force or increase the stiffness of the sample by changing the physical dimensions of the sample. Increasing the frequency will also increase the drive force. Static Force: If Force Track (formerly Autostrain) is used, the static force should adjust to be the set percentage greater than the drive force required to maintain the amplitude programmed. For example, say an amplitude of 20 microns is selected with an auto strain setting of 120%. If the instrument requires 1 N of dynamic force to maintain the set amplitude, the static force should adjust to 1.2 N. In the above example, a Force Track setting of 150% was used. If using constant static force mode, the static force should read 10/16

the value set in instrument parameters. If the initial conditions are acceptable i.e., smooth oscillation and good modulus values, then start the experiment. If the values are not acceptable, then change conditions appropriately. Measuring the Linear Viscoelastic Region of a Material In order to use a DMA to accurately determine mechanical properties and develop morpholigical relationships (crystallinity, molecular weight, crosslinking, etc). 1, the material must be deformed at an amplitude that is within the linear viscoelastic region of the material. Within the linear viscoelastic region, the materials response is independent of the magnitude of the deformation and the materials structure is maintained in tact (unbroken). Characterization of the material within the linear region yields a fingerprint of the morphology of the polymer. Therefore, any morphological differences between polymers can easily be measured as differences in the dynamic mechanical properties. The figure below shows the response of a viscoelastic material to increasing strain (amplitude). The slope of the stress-strain curve is equal to the modulus. In the initial stages of deformation, the slope of the stress versus strain curve (i.e., modulus) is constant. Put another way, we say the response is linear, or the modulus is independent of the strain. At some point, as the deformation gets larger, the slope of the stress-strain curve is no longer constant and the modulus is now a function of the magnitude of the strain. The strain at which the slope of the stress-strain curve is no longer constant, or the point at which the modulus becomes a function of the applied strain is called the critical strain, γ c. In almost all cases the modulus will decrease with increasing strain after the critical strain. As a practical way of finding the end of the linear region, a good rule is to mark the amplitude at which the initial value of the storage modulus changes by 5% (eg. the storage modulus at the lowest amplitude in the sweep). Fig 7. Determination of Linear Viscoelastic Region from a strain-sweep test. Linear Region: Modulus is independent of Strai Non-linear Region: Modulus is a function of str E' or G' Stress Constant Slope γ c = Crit ical St rain Strain (amplitude) Special care should be given when selecting an amplitude (strain) for a DMA 11/16

test. As a general rule γ c of = Critical thumb, solids strain (amplitude) are linear at strains less then 0.1% (0.001 strain units). However, this is a general rule and does not apply to all samples, so the linear region may require verification. The way the linear region is verified will depend on whether you are using a tensioning or non-tensioning clamp. We will discuss each separately. MEASURING THE LINEAR REGION FOR NON-TENSIONING CLAMPS Non-tensioning clamps include dual and single cantilever and shear sandwich only. The linear region for non-tensioning clamps can be measured using a strain sweep test. In a strain sweep test, the frequency of the test is fixed and the amplitude is incrementally increased. To determine the linear viscoelastic region, the storage modulus should be plotted against the amplitude, as the amplitude is the control variable in the DMA 2980. Fig 8. Amplitude sweep time To find the end of the linear region, a good rule is to find the amplitude at which the initial value of the storage modulus (eg. the storage modulus at the lowest amplitude in the sweep) changes by 5%. The figure below shows a comparison of normalized storage modulus versus amplitude for a polystyrene and a filled silicone elastomer sample. The storage modulus was normalized for comparative purposes. It can be seen in the figure below that the polystyrene sample has a much longer linear region as compared to the filled elastomer. After finding the linear region, subsequent scans, such as temperature ramps and frequency sweeps, should be conducted at amplitudes within the linear viscoelastic region. Fig 9. Determining the end of the linear viscoelastic region. 1.10 1.05 Clamp: Single Cantilever Frequency: 1 Hz Filled Silicone Elastomer " General Purpose Polystyrene Normalized Storage Modulus 1.00 0.95 0.90 0.85 0.80 0.75 " " " " " End of Linear Region for Filled Elastomer " " " " End of Linear Region for Polystyrene 0.70 0 20 40 60 80 100 120 140 Amplitude (µm) Universal V2.4D TA Instrument 12/16

MEASURING THE LINEAR REGION FOR TENSIONING CLAMPS The tension film, tension fiber, three point bend, and compression clamps are the tensioning clamps, or clamps which require a static offset force. A discussion of the difference between tensioning and nontensioning clamps can be found in Chapter 5 of the DMA 2980 Operator s Manual (PN984004.001). A discussion of parameters to use with these clamps is discussed in section titled Static Force and Force Track (AutoStrain). Because these clamps require maintaining a static force during an the oscillation, the strain sweep test discussed above cannot be used to STRICTLY define the linear viscoelastic region of a material. This is because when a static force is applied to the sample, the material is already strained. The strain applied to the sample as a result of the static force is in addition to the strain applied to the sample during the oscillation. However, when we plot the amplitude (or strain) we only see the strain generated as a result of the dynamic oscillation. Your initial reaction to this may be, why don t we just add the strain generated from the static force to the dynamic strain. But it is more complicated than simply adding the two. When you increase the amplitude in a strain sweep, the force necessary to drive the increasing amplitude also increases. As a result, the static force required to drive the higher amplitude increases because of Force-track and the strain on the sample increases dramatically. In addition, to do a simple addition of the strain, we would have to assume the sample was reacting perfectly linearly, and we cannot assume that we are in the linear region because we are trying to determine the linear viscoelastic region. Confusing? Let s take an example. Consider a sample in tension. We want to perform a strain sweep at every 5 microns with a Force Track setting of 125%. Assume the force required to drive amplitude of 5 microns is 0.1 N and an amplitude of 5 microns is 0.01% strain. What we will get is the following IF WE ASSUME PERFECT LINEAR RESPONSE. Table 4. Example of strain generated during strain sweep in tensioning clamps. Total Strain Amplitude (microns) Dyn. Force (N) Static Force (N) Dyn. Strain (%) Static Strain (%) (%) 10 0.2 0.25 0.02 0.025 0.0225 15 0.3 0.375 0.03 0.0375 0.045 20 13/16

0.4 0.5 0.04 0.05 0.0675 25 0.5 0.625 0.05 0.0625 0.09 30 0.6 0.75 0.06 0.075 0.1125 35 0.7 0.875 0.07 0.0875 0.135 40 0.8 1.0 0.08 0.1 0.1575 45 0.9 1.125 0.09 0.1125 0.18 50 1.0 1.25 0.1 0.125 0.2025 Remember our rule of thumb states that solids are linear to about 0.1% strain. It can be seen in the above table that this value of dynamic strain is reached at an amplitude of 50 microns, while the same value of static strain is reached at 40 microns, and the total strain exceeds this limit at 25 microns. So here is the loophole. If you perform a strain sweep test as described above for a non-tensioning clamp using a tensioning clamp, you can still look for a 5% change in the storage modulus and draw the conclusion that the sample is showing a linear viscoelastic response under all the experimental conditions just used. However, you cannot define the 5% change in modulus as the end 14/16

of the linear region or critical strain. Why? Because you do not know the total strain on the sample. The Force Ramp Test One method for measuring the linear viscoelastic region of a sample tested in tensioning clamps is a FORCE RAMP test on the sample. In this test we simply deform the sample by an increasing force. The increase in the applied force takes place at a constant rate, such as 1 N/min. m = force ramp rate (N/min) Fig 10. Schematic diagram of a force ramp experiment. This type of deformation is shown in the figure to the right. We can then look at either the force versus dimension change or stress vs. strain curves. This test is very similar to a classic Instron test. The difference is that in an Instron instrument, usually the rate of strain is controlled as opposed to the rate of force. The data below show an example of a force ramp test conducted on a polyethylene sample. Fig 11. Force Ramp on Polyethylene Sample Stress vs. Strain 15/16

1.0 p p 0.8 Static Force (N) 0.6 0.4 0.2 γ c = Critical Strain (%) 0.0 0 50 100 150 200 250 300 350 Dimension Change (µm) Universal V2.6B TA Instrument Figure. Force Ramp on Polyethylene Sample Static Force vs. Dimension Change 1.0 p p 0.8 Static Force (N) 0.6 0.4 0.2 γ c = Critical Strain (amplitude) 0.0 0 50 100 150 200 250 300 350 Dimension Change (µm) Universal V2.6B TA Instrument Reference 1. Reference: Turi, Edith A., Thermal Characterization of Polymeric Materials, Second Edition, Volume I., Academic Press, Brooklyn, New York, 1997, P. 980. 16/16