Building Envelope Requirements Overview Page 3-4

Similar documents
Today s A/C systems include:

Inclusion of Solar Reflectance and Thermal Emittance Prescriptive Requirements for Steep-Sloped Nonresidential Roofs in Title 24

COOL SHINGLES COOL SCIENCE. California Energy Code Title 24, Part 6 Compliant

Abstract. Introduction. Benefits of cool roofs

Welcome. HVAC Change Out Regulations and Rater Verification California Track

Cool Roofs and Reroofing

COOL SHINGLES COOL SCIENCE. California Energy Code Title 24, Part 6 Compliant

2018 North Carolina Residential Code Prescriptive Tables for Selection of Support Elements for Beams, Girders, and Headers: Example Problems

Imagine... a Roof that can pay for Itself! 1 Cool Roof Leader THE LEADER IN COOL ROOF TILE IN THE U.S.

CPO Science Foundations of Physics. Unit 8, Chapter 26

The Effects of Infrared-Blocking Pigments and Deck Venting on Stone-Coated Metal Residential Roofs

5. Thermal Design. Objective: Control heat flow to: Maintain comfortable indoor conditions

PHYSICS OF FOIL. HEAT GAIN/LOSS IN BUILDINGS. Up Heat Flow. Down Heat Flow. Side Heat Flow

THERMAL DYNAMIC BEHAVIOR OF SINGLE COMPONENT: EXPERIMENTAL ANALYSIS AND NUMERICAL MODELING

Guide Specifications Section

Here Comes the Sun. Rachel Wagner. Duluth Energy Design Conference 26 February

Design strategy for Low e windows with effective insulation

PHYSICS 220. Lecture 25. Textbook Sections Lecture 25 Purdue University, Physics 220 1

Heat Transfer. Conduction, Convection, and Radiation. Review: Temperature

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

Energy Transfers. Heat Transfer. Internal Energy. Going With The Flow! 5/12/17. à Thermal Energy. Q = mcdt Q =DU. U = N(1/2mv 2 )

COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

Hygrothermal Performance of Ventilated Cold Roofs an Experimental Study

CAE 463/524 Building Enclosure Design Fall 2012

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Use of Phase-Change Materials to Enhance the Thermal Performance of Building Insulations

University of New Mexico Mechanical Engineering Spring 2012 PhD qualifying examination Heat Transfer

Chapter 3. Basic Principles. Contents

DEVELOPMENT OF COOLING LOAD TEMPERATURE DIFFERENTIAL VALUES FOR BUILDING ENVELOPES IN THAILAND

announcements 4/17/08

Addendum to ARI Standard , Air Terminals September 2002

F. A. Q. Frequently Asked Questions about ASTEC. Copyright 2007 Insulating Coatings Corporation

ARCH 348 BUILDING AND ENVIRONMENTAL SYSTEMS

ATS150 Global Climate Change Spring 2019 Candidate Questions for Exam #1

Science 7 Unit C: Heat and Temperature. Topic 6. Transferring Energy. pp WORKBOOK. Name:

ANSI/SPRI ES-1 Test Reports UL Classified Products

HOT /05/2014. Page 1 of 14 GENERAL HOUSE CHARACTERISTICS. Natural Resources CANADA Version sample house report

Winter Night. Thermos 6mm Outdoors # #

Chapter 13 The Transfer of Heat

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

TRANSMISSION OF HEAT

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Transportation Noise Assessment Prince of Wales Residential Development Ottawa, Ontario

PHYSICS 149: Lecture 26

Exercises Conduction (pages ) 1. Define conduction. 2. What is a conductor?

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 2/11/2013 BUILDING SURVEY DATE

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

Project 2. Introduction: 10/23/2016. Josh Rodriguez and Becca Behrens

Introduction to Electromagnetic Radiation and Radiative Transfer

ANSI/CRRC S100 (2016) Standard Test Methods for Determining Radiative Properties of Materials

General Physics (PHY 2130)

EPA ENERGY STAR Program Modification Request. Qualifying Products Using Calculated 3-Year Aged Values From Initial Solar Reflectance

Conduction, Convection, and Radiation

Δ q = ( ψ L) HDH (1) here, Δq is the additional heat transfer caused by the thermal bridge, Ψ and L are the linear thermal transmittance and length of

K20: Temperature, Heat, and How Heat Moves

Sixth Grade Science BLOCK 3 ASSESSMENT Heat, Light, and Sound

Cedarbrook Sauna + Steam Family owned and operated since 1971

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

ERT 460 CONTROLLED ENVIRONMENT DESIGN II HEAT TRANSFER. En Mohd Khairul Rabani Bin Hashim

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

Tips on Using Infrared During a Home Inspection Jan 5, 2017 Ben Gromicko

Chapter 6. Atoms and Starlight

The energy performance of an airflow window

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

Chapter 1 Heating Processes

Thermal Radiation By: Prof. K M Joshi

2. Climate (Outdoor) Altitude. Distance from the ocean. Conditions of the ocean. Store/release heat. angle of solar radiation Amount of solar energy

CAE 331/513 Building Science Fall 2016

KITCHEN. How can improvements or remodeling save me money? Increase Attic Insulation Add a Ceiling Fan Add Vacancy Sensors

Chapter 11. Energy in Thermal Processes

CRRC-1 STANDARD Cool Roof Rating Council, Inc. All Rights Reserved. Cool Roof Rating Council 1610 Harrison Street Oakland, CA 94612

Name Class Date. What are three kinds of energy transfer? What are conductors and insulators? What makes something a good conductor of heat?

Back to Basics: Realizing Cabling Determines Design. F. Patrick Mahoney, CSI CDT, RCDD Direct Supply - Aptura

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

Chapter 22: Uses of Solar Energy

Energy and Insolation Review 2

Chapter 5 Light and Matter: Reading Messages from the Cosmos. 5.1 Light in Everyday Life. How do we experience light?

Homework #4 Solution

Glazing selection for solar design

Name: Partner(s): 1102 or 3311: Desk # Date: Spectroscopy Part I

SPH3U1 Lesson 03 Energy

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Lecture 6. Solar vs. terrestrial radiation and the bare rock climate model.

Night-time radiative cooling: harvesting the darkness of the universe

Equilibrium in Two Dimensions

TECHNICAL COMMITTEE of the EU Cool Roofs Council

Chapter 5 Light and Matter: Reading Messages from the Cosmos. How do we experience light? Colors of Light. How do light and matter interact?

Chapter 5: Light and Matter: Reading Messages from the Cosmos

Absorptivity, Reflectivity, and Transmissivity

A) usually less B) dark colored and rough D) light colored with a smooth surface A) transparency of the atmosphere D) rough, black surface

Chapter 11. Important to distinguish between them. They are not interchangeable. They mean very different things when used in physics Internal Energy

L 18 Thermodynamics [3] Heat flow. Conduction. Convection. Thermal Conductivity. heat conduction. Heat transfer

8.2 The Sun pg Stars emit electromagnetic radiation, which travels at the speed of light.

Roadway Traffic Noise Feasibility Assessment. 315 Chapel Street. Ottawa, Ontario

Innovative Products February 2016

PHYS:1200 LECTURE 18 THERMODYNAMICS (3)

Arctice Engineering Module 3a Page 1 of 32

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

Transcription:

Building Envelope Requirements Overview Page 3-4 The benefit of a high reflectance surface is obvious: while dark surfaces absorb the sun s energy (visible light, invisible infrared. and ultraviolet radiation) and become hot, light-colored surfaces reflect solar energy and stay cooler. However, high emittance is also important. Emittance refers to the ability of heat to escape from a surface once it is absorbed. Surfaces with low emittance (usually shiny metallic surfaces) contribute to the transmission of heat into the roof components under the roof surface. The heat can increase the building s air conditioning load resulting in increased air conditioning load and less comfort for the occupants. High-emitting roof surfaces give off absorbed heat relatively quickly through the path of least resistance- upward (and out of the building). Rating and Labeling Roofing products that are used for compliance with the standards (prescriptive and performance approaches) are require to be tested and labeled by the Cool Roof Rating Council (CRRC) per 10-113 and that liquid applied products meet minimum standards for performance and durability per 118(i)4. The CRRC is the supervisory entity responsible for certifying cool roof products. The CRRC test procedure is documented in CRRC-1, the CRRC Product Rating Program Manual. This test procedure includes tests for both solar reflectance and thermal emittance. The roofing products manufacturer must have its roofing product tested for solar reflectance and thermal emittance, and be labeled according to CRRC procedures. Figure 3-1 provides an example of an approved CRRC product label. Figure 3-1- CRRC Product label and information The residential roofing product requirement in the prescriptive package is as follows. For steep-sloped applications in climate zones 10-15, for roofing products that have a density of less than 5 pounds per square foot (generally, asphalt shingle and metal products) there is a three year aged solar reflectance requirement of and a (three year aged or new) thermal emittance

Building Envelope Requirements Overview Page 3-5 requirement of, or a minimum solar reflectance index (SRI) of 16. For roofing products with a density of 5 pounds per square feet or more (generally include concrete, clay tiles, slate and possibly some synthetic roof coverings), in climate zones 1-16, there is a minimum aged solar reflectance of 0.15 and thermal emittance of, or a minimum SRI of 10. For low-sloped roofing applications, in climate zones 13 and 15, there is a minimum aged solar reflectance of 0.55 and thermal emittance of, or a minimum SRI of 64. There are two exceptions to meeting the roofing products requirements in the prescriptive package: 1. The roof area with building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the minimum requirements for aged solar reflectance and thermal emittance or SRI per Exception 1 to 151(f)12. 2. If roof constructions that have thermal mass over the roof membrane with a weight of at least 25 lb/ft 2 are exempt from the minimum requirements for aged solar reflectance and thermal emittance or SRI under Exception 2 to 151(f)12 If the aged value for the reflectance is not available in the CRRC s Rated Product Directory then the equation bellow can be used until the aged rated value for the reflectance is posted in the directory. Aged Reflectance calculated =(0.2+0.7[ρ initial 0.2]) Where ρ initial = Initial Reflectance listed in the CRRC Rated Product Directory. Solar Reflectance Index (SRI) is a new concept in the 2008 Standards; in lieu of meeting a thermal resistance and solar reflectance requirement, compliance can be shown by meeting a minimum SRI. The temperature of a surface depends on the surface s reflectance and emittance, as well as solar radiation. The SRI measures the relative steady-state surface temperature of a surface with respect to the standard white (SRI=100) and standard black (SRI=0) under the standard solar and ambient condition. A calculator was produced by the staff at Lawrence Berkeley National Laboratory which calculates the SRI by designating the solar reflectance and thermal emittance of the desired roofing material. Calculations shall be based on moderate wind velocity of 2-6 meters per second. To calculate the SRI the 3-year aged value of the roofing product must be used. By using the SRI calculator a cool roof may comply with an emittance lower than 0.85 as long as the aged reflectance is higher. Also, SRI can be obtained by trading off a lower aged solar reflectance with a higher thermal emittance. Although not included as prescriptive equivalents for new construction, 152(b)1H contains acceptable cool roof alternatives to the prescriptive requirements for alterations. These alterations can also be utilized in the design and construction of a new roof system to improve the thermal performance by reducing the cooling energy load placed on the building. Examples of these practices that can be utilized in new construction and that a contractor or designer could consider include: (Note: some of the following measures may result in an additional compliance credit if incorporated into the building.)

Building Envelope Requirements Overview Page 3-6 a. Insulation with a thermal resistance of at least 0.85 hr ft 2 F/Btu or at least a 3/4 inch air-space is added to the roof deck over an attic; or b. Existing ducts in the attic are insulated and sealed according to 151(f)10; or c. In climate zones 10, 12 and 13, with 1 ft 2 of free ventilation area of attic ventilation for every 150 ft 2 of attic floor area, and where at least 30 percent of the free ventilation area is within two feet vertical distance of the roof ridge; or d. Buildings with additional ceiling insulation annexes of the Prescriptive package requirement for the climate zone; or e. Buildings with a radiant barrier in the attic meeting the requirements of 151(f)2; or f. Buildings that have no ducts in the attic; or g. In climate zones 10, 11, 13 and 14, R-3 or greater roof deck insulation above vented attic.

Building Envelope Requirements Insulation Page 3-55 Example 3-14 The prescriptive requirements call for a cool roof in both low-slope and steepslope applications for residential buildings. A low-slope roof is defined as a surface with a pitch less than or equal to 2:12 (9.5 degrees from the horizontal) while a steep-slope roof is a surface with a pitch greater than 2:12 (9.5 degrees from the horizontal). The prescriptive requirements for cool roofs under the new 2008 Standards are now climate zone dependent and the aged reflectance and emittance criteria depend on the type of roofing material being used. Solar Reflectance Index (SRI) is a new concept with in the 2008 Standards. The temperature of a surface depends on the surface s reflectance and emittance, as well as solar radiation. The SRI measures the relative steadystate surface temperature of a surface with respect to the standard white (SRI=100) and standard black (SRI=0) under the standard solar and ambient condition. A calculator was produced by the staff at Lawrence Berkeley National Laboratory which calculates the SRI by designating the Solar Reflectance and Thermal emittance of the desired roofing material. SRI calculations shall be based on moderate wind velocity of 2-6 meters per second. To calculate the SRI the 3-year aged value of the roofing product must be used. By using the SRI calculator a cool roof may comply with an emittance lower than 0.85 as long as the aged reflectance is higher. A qualifying cool roof must have an aged reflectance and emittance greater than or equal to that provided. Also to be a cool roof the roofing material must be listed in the CRRC s Rated Product Directory (see http://www.coolroofs.org). For a newly constructed Low-Rise Residential buildings with steep-slope roofs in Climate Zones 1-16 with a density of 5 lbs/ft 2 or more, is required to have an aged reflectance of 0.15 and aged emittance of, or a SRI equivalence of 10. In Climate Zones 10-15, low density roofs, weighing less than 5 lbs/ft 2, is required to have an aged reflectance of and aged emittance of, or a SRI equivalence of 16. However, if the aged value for the reflectance is not available in the CRRC s Rated Product Directory then the equation below can be used until the aged rated value for the reflectance is posted in the directory. Aged Reflectance calculated =(0.2+0.7[ρ initial 0.2]) Where ρ initial = Initial Reflectance listed in the CRRC Rated Product Directory. In addition to the questions and answers below about cool roofs, the 2008 Nonresidential Manual contains more cool roof information (including different questions and answers) in Section 3.4. Is a cool roof required in new residential construction or in residential alterations or additions? Yes, for the 2008 Title 24 Standards cool roof is required when using the prescriptive package in new residential construction, additions or alterations. Cool roof now applies to both low-slope and steep-slope residential roofs. Also, the cool roof requirement is different per climate zone and per the type of product being used (product weighing less than 5 lbs/ft 2 or 5 lbs/ft 2 or

Building Envelope Requirements Insulation Page 3-56 more). If one wishes not to install a cool roof then they must meet the title 24 Standards using the performance method where tradeoffs can be done. Example 3-15 I am a salesperson and represent some roofing products, and many of them are on the EPA s Energy Star list for cool roofing materials. Is this sufficient to meet Title 24 Standards? No. Energy Star has different requirements for reflectance and NO requirements for emittance. The Cool Roof Rating Council (http://www.coolroofs.org) is the only entity currently recognized by the Energy Commission to determine what qualifies as a cool roof under Title 24. Example 3-16 Example 3-17 How does a product get CRRC cool roof certification? Any party wishing to have a product or products certified by CRRC should contact CRRC to get started - call toll-free (86 465-2523 from inside the US or (510) 485-7176, or email info@coolroofs.org. CRRC staff will walk interested parties through the procedures. In addition, CRRC publishes the procedures in "CRRC-1 Program Manual," available for free on http://www.coolroofs.org or by calling CRRC. However, working with CRRC staff is strongly recommended. Example 3-18 I ve heard the words reflectivity, reflectance, emissivity, and emittance? Can you explain? Reflectivity and reflectance denote the same thing, but the Standards use only reflectance to avoid confusion. Emissivity and emittance denote the same thing, and again the Standards use only emittance. Example 3-19 I understand reflectance, but what is emittance? Even a material that reflects the sun s energy will still absorb some of that energy as heat; there are no perfectly reflecting materials being used for roofing. That absorbed heat undergoes a physical change (an increase in wavelength, for readers who remember physics) and is given off emitted to the environment in varying amounts by various materials and surface types. This emittance is given a unitless value between 0 and 1, and this value represents a comparison (ratio) between what a given material or surface emits and what a perfect blackbody emitter (again, recall physics) would emit at the same temperature.

Additions, Alterations and Repairs Building Envelope Page 8-8 150(c) if the building can show compliance using performance compliance and modeling R-11. Roofing Products All roofing products must meet the mandatory requirements of 10-113 and 118(i), and the prescriptive requirements of 152(b)1H. Roofing products with high solar reflectance and thermal emittance are referred to as cool roof, which refers to an outer layer or exterior surface of a roof. As the term implies, the temperature of a cool roof is lower on hot sunny days than for a conventional roof, reducing cooling loads and the energy required to provide air conditioning. The benefit of a high reflectance is obvious: while dark surfaces absorb the sun s energy (visible light, invisible infrared. and ultraviolet radiation) and become hot, light-colored surfaces reflect solar energy and stay cooler. However, high emittance is also important. Emittance refers to the ability of heat to escape from a surface once it is absorbed. Surfaces with low emittance (usually shiny metallic surfaces) contribute to the transmission of heat into the roof components under the roof surface. The heat can increase the building s air conditioning load resulting in increased air conditioning load and less comfort for the occupants. High-emitting roof surfaces give off absorbed heat relatively quickly through the path of least resistance- upward (and out of the building). Rating and Labeling Roofing products that are used for compliance with the standards (prescriptive and performance approaches) are require to be tested and labeled by the Cool Roof Rating Council (CRRC) per 10-113 and that liquid applied products meet minimum standards for performance and durability per 118(i)4. The CRRC is the supervisory entity responsible for certifying cool roof products. The CRRC test procedure is documented in CRRC-1, the CRRC Product Rating Program Manual. This test procedure includes tests for both solar reflectance and thermal emittance. The roofing products manufacturer must have its roofing product tested for solar reflectance and thermal emittance, and be labeled according to CRRC procedures. Figure 8-1 provides an example of an approved CRRC product label

Additions, Alterations and Repairs Building Envelope Page 8-19 Example 8-17 I am considering doing a reroof on my home. When will I be required to put on a cool roof? Cool roof requirements are triggered when either more than 50 percent of the roof area or more than 1,000 ft 2, whichever is less is replaced. If one of the exceptions below applies then cool roof requirements are not triggered: Buildings with no ducts in the attic; or If the building with a radiant barrier in the attic meeting the requirements of section 152(f)2 of the Title 24 standards Part 6; or Buildings with at least R-30 ceiling insulation; or If in climate Zones 10, 11, 13, and 14, R-3 or greater roof deck insulation above vented attic; or If existing ducts in the attic are insulated and sealed according to section 151(f)10 of the title 24 standards part 6; or Insulation with a thermal resistance of at least 0.85hr. ft 2.o F/Btu or at least ¾ inch air-space is added to the rook deck over an attic; or In climate zones, 10, 12, and 13, with 1ft 2 of free ventilation area of attic ventilation for every 150 ft 2 of attic floor area, and where at least 30 percent of the free ventilation area is within two feet vertical distance of the roof ridge; or If the building can show compliance using performance approach. Example 8-18 I am building a 450 ft 2 addition on my house; do I have to meet cool roof requirements in the prescriptive package? Yes, if using prescriptive compliance the roof must meet the cool roof requirements of Package D for the type of roof slope and density. To avoid the cool roof requirements requirement you can use the performance approach and tradeoff against other energy efficiency features of the addition alone or the existing building use the existing + addition + alteration approach.

2008 Building Energy Efficiency Standards Page 150 TABLE 151-B COMPONENT PACKAGE C Climate Zone 1, 16 3 4 5 6 7 8, 9 10 2, 11-13 14 15 BUILDING ENVELOPE Insulation minimums 1 Ceiling R49 R38 R38 R38 R38 R38 R38 R49 R49 R49 R49 Wood-frame walls R29 R25 R25 R25 R21 R21 R21 R25 R29 R29 R29 Heavy mass walls NA NA NA NA NA NA NA NA NA NA NA Light mass walls NA NA NA NA NA NA NA NA NA NA NA Below-grade walls NA NA NA NA NA NA NA NA NA NA NA Slab floor perimeter R7 R7 R7 R7 R7 R7 R7 R7 R7 R7 R7 Raised floors R30 R30 R30 R30 R21 R21 R21 R30 R30 R30 R21 Concrete raised floors NA NA NA NA NA NA NA NA NA NA NA Radiant Barrier REQ REQ REQ REQ REQ REQ Roofing Products FENESTRATION See TABLE 151-C, COMPONENT PACKAGE D Maximum U-factor 2 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 Maximum Solar Heat 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 Gain Coefficient (SHGC) 3 Maximum total area 14% 14% 14% 16% 14% 14% 14% 16% 16% 14% 16% Maximum West facing area 5% 5% 5% 5% 5% 5% 5% THERMAL MASS 4 REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ SPACE-HEATING 5 Electric-resistant allowed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes If gas, AFUE = MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN If heat pump, HSPF 6 = MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN SPACE-COOLING SEER = MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN If split system, Refrigerant charge measurement or charge indicator display Central Forced Air Handler: DUCTS REQ REQ REQ REQ REQ See TABLE 151-C, COMPONENT PACKAGE D Duct sealing REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ Duct Insulation R-8 R-8 R-8 R-8 R-8 R-8 R-8 R-8 R-8 R-8 R-8 WATER-HEATING System shall meet Section 151(f)8 or Section 151(b)1 7 SECTION 151 PERFORMANCE AND PRESCRIPTIVE COMPLIANCE APPROACHES

2008 Building Energy Efficiency Standards Page 151 TABLE 151-C COMPONENT PACKAGE D Insulation minimums 1 Climate Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Ceilings R38 R30 R30 R30 R30 R30 R30 R30 R30 R30 R38 R38 R38 R38 R38 R38 Walls Floors Wood-frame walls R21 R13 R13 R13 R13 R13 R13 R13 R13 R13 R19 R19 R19 R21 R21 R21 Heavy mass walls Light mass walls NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA Below-grade walls R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R13 Slab floor perim. R7 Raised floors R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 R19 Concrete raised floors R8 R8 R0 R0 R0 R0 R0 R0 R0 R0 R8 R4 R8 R8 R4 R8 Radiant Barrier REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ Roofing Products Fenestration Low-sloped Aged Solar 0.55 0.55 Reflectance Thermal Emittance Steep Sloped (less than 5 lb/ft²) Aged Solar Reflectance Thermal Emittance Steep Sloped (5 lb/ft² or more) Aged Solar Reflectance 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 Thermal Emittance Maximum U-factor 2 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 Maximum Solar Heat Gain 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.35 Coefficient (SHGC) 3 Maximum Total Area 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% Maximum West Facing Area 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% THERMAL MASS 4 SPACE- HEATING 5, 10 SPACE- COOLING Central Forced Air Handlers Electric-resistant allowed No No No No No No No No No No No No No No No No If gas, AFUE = MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN If heat pump, HSPF 6 = MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN SEER = MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN MIN If split system, Refrigerant charge measurement or charge indicator REQ REQ REQ REQ REQ REQ REQ REQ REQ display Cooling Airflow and Watt Draw REQ REQ REQ REQ REQ REQ Central Fan Integrated Ventilation System Watt Draw REQ REQ REQ 2 REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ DUCTS Duct sealing REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ SECTION 151 PERFORMANCE AND PRESCRIPTIVE COMPLIANCE APPROACHES