Proportional Counters

Similar documents
Ionization Detectors. Mostly Gaseous Detectors

Ionization Detectors

Resolution. σ z. = σ z. If D(z) is gaussian the relation between FWHM and standard deviation is. = Δz 2.36

3. Gas Detectors General introduction

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

EEE4106Z Radiation Interactions & Detection

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

General Overview of Gas Filled Detectors

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Particle Energy Loss in Matter

Radionuclide Imaging MII Detection of Nuclear Emission

Design optimisation of X-ray detectors for SSM

Particle Energy Loss in Matter

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Lecture 4. Detectors for Ionizing Particles

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Nuclear Physics and Astrophysics

The X-Ray Universe. Potsdam University. Dr. Lidia Oskinova Wintersemester 2008/09

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

GEM: A new concept for electron amplification in gas detectors

Chapter 3 Gas Filled Detectors

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Gamma and X-Ray Detection

PHYS 3446 Lecture #12

Chapter 4 Scintillation Detectors

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

Understanding X-rays: The electromagnetic spectrum

Radioactivity. Lecture 6 Detectors and Instrumentation

GEANT4 Simulations of. the LAXPC Performance. H. M. Antia. Tata Institute of Fundamental Research

Diffractometer. Geometry Optics Detectors

Photoelectron spectroscopy Instrumentation. Nanomaterials characterization 2

Understanding X-rays: The electromagnetic spectrum

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

Chemistry Instrumental Analysis Lecture 17. Chem 4631

Dr. Nidal M. Ershaidat Dr. Nidal M. Ershaidat - Nuclear Techniques - Chapter 5: Gas-Filled Detectors 2

Radiation Detection and Measurement

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Diffraction: spreading of waves around obstacles (EM waves, matter, or sound) Interference: the interaction of waves

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

08 - Miscellaneous and historical detectors

Absorption and Backscattering ofβrays

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

X-Ray Photoelectron Spectroscopy (XPS)

X-ray Polarimetry with gas proportional counters through rise-time

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

Seminar talks. Overall description of CLAS12 (Jefferson Lab) MAPS. Talks on Feb. 6 th, (Contact JR) (Contact TS)

Generic Detector. Layers of Detector Systems around Collision Point

Secondary Ion Mass Spectrometry (SIMS)

Chemical Engineering 412

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

Xe and 36 Kr gas filled proportional counters and characteristic X-rays detection

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

PHOTOELECTRON SPECTROSCOPY IN AIR (PESA)

Waste Characterization

Scintillation Detector

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. II - Particle Detectors - Tsipenyuk Yu.M.

Scintillators General Characteristics

R&D on Astroparticles Detectors. (Activity on CSN )

EXCESS HEAT PRODUCTION IN Pd/D DURING PERIODIC PULSE DISCHARGE CURRENT IN VARIOUS CONDITIONS

Signals in Particle Detectors (1/2?)

Advanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

X-Ray Photoelectron Spectroscopy (XPS)

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

SiPM & Plastic Scintillator

Introduction. Principle of Operation

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

B. Sitar G. I. Merso n V. A. Chechin Yu. A. Budagov. Ionization Measurement s in High Energy Physics

Chapter Seven (Nuclear Detectors)

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Electron temperature is the temperature that describes, through Maxwell's law, the kinetic energy distribution of the free electrons.

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Development of New MicroStrip Gas Chambers for X-ray Applications

PANDA-?? A New Detector for Dark Matter Search

Advances in the Micro-Hole & Strip Plate gaseous detector

Absorption and Backscattering of β-rays

Ionization Techniques Part IV

X-ray Absorption and Emission Prepared By Jose Hodak for BSAC program 2008

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

Chapiter VII: Ionization chamber

The outline. 1) Detector parameters: efficiency, geometrical acceptance, dead-time, resolution, linearity. 2) gaseous ionization chambers

Combinatorial RF Magnetron Sputtering for Rapid Materials Discovery: Methodology and Applications

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence

Ba (Z = 56) W (Z = 74) preferred target Mo (Z = 42) Pb (Z = 82) Pd (Z = 64)

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Sensors and Detectors Part 2

Queen s University PHYS 352

1.4 The Tools of the Trade!

A proposal to study gas gain fluctuations in Micromegas detectors

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Auger Electron Spectroscopy (AES)

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Single Photon detectors

The GEM scintillation in He-CF 4, Ar-CF 4, Ar-TEA and Xe-TEA mixtures

Transcription:

Proportional Counters 3 1

Introduction 3 2 Before we can look at individual radiation processes, we need to understand how the radiation is detected: Non-imaging detectors Detectors capable of detecting photons from a source, but without any spatial resolution = Require, e.g., collimators to limit field of view. Example: Proportional Counters Imaging detectors Detectors with a spatial resolution, typically used in the IR, optical, UV or for soft X-rays. Generally behind some type of focusing optics. Example: Charge coupled devices (CCDs) Here: will concentrate on detectors for X-rays and optical light, starting with non-imaging detectors. Introduction 1

Ionization chamber 3 3 + + + + + + Cathode Anode Volume filled with detector gas R U Simplest gas detector: gas-filled capacitor (ionization chamber) photon is photo absorbed in detector gas K-shell electron ejected with energy initial E through collisional ionization N charges are produced Electrostatic induction induces charge on capacitor plates Charges drain via R = Measurement Pulse height: Q = Ne = C U = U = Ne/C Typical magnitude of signal: C = 20 pf, Ne = 2 10 5 e e = U = 1.6 mv. Problem: Pulse very weak since only primary charge measured. Proportional counters 1

Proportional Counters 3 4 High voltage Entrance window detector gas Cylindrical Cathode Anode wire Solution: amplify charge Close to Anodewire: E(r) = V/(r ln(b/a) (b radius of cathode, a radius of anode) = Strong acceleration of ionized particles = collisional ionization of gas = cascade! Measured voltage: U = en C A where A: amplification factor (typical: A = 10 4... 10 6 ). Since A const.: Voltage pulse N, and therefore Voltage pulse detected X-ray energy! and therefore: proportional counter Proportional counters 2

Pulse Amplification 3 5 Number of collected ions/electrons 10 14 12 10 10 10 10 8 10 6 4 10 10 2 Recombination glow discharge Ionization chamber Proportional counter Geiger counter Limited proportionality 0 250 500 750 1000 1250 Voltage [V] Pulse amplification in detector as a function of anode voltage. Typical proportional counter voltages are several 100 to 1000 V (depending on detector gas). (after Grupen, Fig.4.21) Proportional counters 3

Detector Gas 3 6 Use inert gases, e.g., Ar or Xe, since required voltage smallest and only low losses due to excitation of the gas atoms. Number of ions produced: N = E/ω, where ω is given by: Gas H He Ne Ar Kr ω [ev] 36.6 44.4 36.8 26.25 24.1 Gas Xe Air CO 2 CH 4 ω [ev] 21.9 35.2 34.2 29.1 = Typically N 1000 electron-ion pairs per 20 kev photon. Note: probability for absorption σ bf Z 4...5 = use Xenon (Z = 54) for astronomical detectors since σ bf E 3 = proportional counters limited to E < 100 kev. Proportional counters 4

Cascade, I 3 7 Electron Gas ions Electron cascade Secondary electrons anode wire Grupen (Fig. 4.9) Typical electron paths µm = Cascade happens very close to anode wire Proportional counters 5

Cascade, II 3 8 Grupen (Fig. 4.27) Electrons are accelerated to very high speeds towards wire, Ions are accelerated away from wire = Main signal from ions, not electrons, since ions have larger potential difference typical duration of signal 100 µs, can reach higher time resolution by differentiating the signal Proportional counters 6

Energy Resolution 3 9 Measured signal: pulse height = Energy of the X-ray Resolution: E: Width (=FWHM, Full Width at Half Maximum) of the distribution of measured energies. Poisson statistics (N discrete Electron-Ion pairs!): E 2.35 N 2.35 E Typically one uses E/E Slight correlations due to amplifying discharge = Width of distribution somewhat smaller than expected from Poisson statistics = Fano Factor F : where for gas detectors F 0.2 0.3 E E = 2.35 ( F N ) 1/2 More detailed theory yields ( ) E W (F + A) 1/2 E = 2.35 E W : mean energy to produce a pair (26 ev for Ar+Methane), F 0.2, A 0.6 = up to 14% at 5.9 kev doable. Proportional counters 7

Quenching 3 10 Problem: Excited ions emit UV photons = formation of new cascades due to photo effect = Total cascade takes a long time = large dead time. Solution: Absorption of UV photons in quenching gas, which is added to primary photomultiplier gas = cascade < 1 µs Energy of excited quenching gas is dumped later via inelastic collisions within the gas Also direct quenching of cascade, e.g., via Ar + + CH 4 Ar + CH + Typical quenching gases: CH 4, alcohol (C 2 H 5 OH), CO 2, BF 3,... (about 10% of total gas pressure). Often used: P10-gas (90% Ar and 10% CH 4 ) Proportional counters 8

Ageing 3 11 Marko Spegel, 1999 (Diss. Uni Wien), J. Vavra, SLAC-3882 Cascade: plasma discharge = Destruction of gas contaminants = formation of free radicals = polymerization Polymers have high dipole moment = attach to electrodes = Reduction of pulse charges = Ageing Typical contaminants: carbon, oxide-layers, silicates, e.g., from oil, finger grease, Silan (SiH 4 ), solvents in vacuum sealants,... Results in field electron emission through photo-effect = discharge = wire destroyed ( Malter-Effekt ) Most sensitive proportional counter gas: Ar/CH 4... Proportional counters 9

Example: RXTE-PCA 3 12 Rossi X-ray Timing Explorer HEXTE A B PCA (1 of 5) ASM Rossi-X-ray Timing Explorer, Launch 30.12.1995, 3 instruments: Proportional Counter Array (PCA, 2 100 kev), High Energy X-ray Timing Experiment (HEXTE, 15 250 kev), All Sky Monitor (ASM, 2 10 kev) PCA and HEXTE have µsec timing resolution Proportional counters 10

Example: RXTE-PCA 3 13 Proportional counters 11

Example: RXTE-PCA 3 14 Shielding 3.6 cm hexagonal Collimator Mylar Windows (25 µ m) Propane layer (anticoincidence) Xenon/Methane layers (signal layers) Xenon/Methane chambers (anticoincidence) PCA consists of 5 Proportional Counter Units (PCUs), 1 atm pressure Propane and outer anodes in Anti-Coincidence = Background reduction BeCu-Collimator to limit field of view to 1 Alpha Detector Am source 32.5cm 241 Am-source for energy calibration (simultaneous emission of 59.6 kev γ s and α-particles = coincidence measurements). Proportional counters 12

Example: RXTE-PCA 3 15 Design of the PCA (NASA/GSFC) Proportional counters 13

Example: RXTE-PCA 3 16 100 RXTE-PCA Photon Energy [kev] 10 Response matrix: Relation between incident photon energy and detection channel. 1 10 100 PHA Channel Energy [kev] Resolution: 18% at 6 kev Escape-Peaks caused by Xe Kα (E = 29.46 kev) and Xe Lα (E = 4.11 kev) photons leaving the detector without being detected. Proportional counters 14

Example: RXTE-PCA 3 17... this is what happens once a Mylar window starts having a hole in space In addition ageing = Reduction of high voltage, alternate use of different PCUs. Proportional counters 15