Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 1 o 15 TANAKA ELECTRONICS (M) SDN BHD PLOT 11, PHASE IV, BAYAN LEPAS FREE INDUSTRIAL ZONE 11900 PENANG, MALAYSIA The ollowing merchandise was (were) submitted and identiied by the client as: Sample Description : Au Bonding Wire Sample Receiving Date : 10/10/2013 Testing Period : 10/10/2013 to 17/10/2013 Date Completed : 17/10/2013 Reporting Date : 01/11/2013 Test Requested : Selected test(s) as requested by client Test Method : Please reer to next page(s). Test Results : Please reer to next page(s). Analysts : Ng Jing Wei, Cho Kar Yen, Tan Li Wei, Teh Pui Sean, Lim Meng Hoe Tay Siam Pine & Yee Sook Wai
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 2 o 15 Test results: Test Part Description : Sample Description : Au Bonding Wire RoHS Directive 2011/65/EU Annex II Test Item(s): Unit Test Method Results MDL Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (CrVI) Hexavalent Chromium (CrVI) by Spot test / boiling water extraction (optional) # Sum o PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Hexabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl perormed by ICP-OES perormed by ICP-OES perormed by ICP-OES With reerence to JIS H 8625, and perormed by UV-VIS Spectrophotometry N.D. 2 N.D. 2 N.D. 2 N.D. 2 --- With reerence to IEC 62321:2008 Negative - N.D. -
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 3 o 15 Sum o PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether N.D. - Note : (a) = ppm ; (0.1wt% = 1000ppm) (b) N.D. = Not Detected (c) MDL = Method Detection Limit (d) # = Spot-Test: a. Negative means the absence o Cr(VI) on the tested areas b. Positive means the presence o Cr(VI) on the tested areas (The tested sample should be urther veriied by boiling-water-extraction method i the spot test result is negative or cannot be conirmed) Boiling water extraction: a. Negative means the absence o Cr(VI) on the tested areas b. Positive means the presence o Cr(VI) on the tested areas; The detected concentration in 50 ml boiling water extraction solution is equal or greater than 0.02 with 50 cm 2 sample surace area. For corrosion protection coatings on metals: Inormation on storage conditions and production date o the tested sample is unavailable and thus results o Cr(VI) represent status o the sample at the time o testing. (e) - = Not regulated
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 4 o 15 Test results by chemical method: Test Item (s): Unit Method Result MDL Antimony (Sb) With reerence to EPA Method 3051A, and perormed by ICP-OES N.D. 2 Magnesium (Mg) With reerence to EPA Method 3051A, and perormed by ICP-OES N.D. 2 Beryllium (Be) With reerence to EPA Method 3051A, and perormed by ICP-OES 5 2 Polyvinylchloride (PVC) ** Analysis was perormed by FT-IR/ATR Negative - Halogen --- --- --- --- Halogen-Fluorine (F) With reerence to BS EN 14582. Analysis was perormed by IC method or Fluorine content. 0 Halogen-Chlorine (Cl) With reerence to BS EN 14582. Analysis was perormed by IC method or Chlorine content. 0 Halogen-Bromine (Br) With reerence to BS EN 14582. Analysis was perormed by IC method or Bromine content. 0 Halogen-Iodine (I) With reerence to BS EN 14582. Analysis was perormed by IC method or Iodine content. 0 Test Part Description: Sample Description : Au Bonding Wire Note : (a) = ppm (b) N.D. = Not Detected (d) --- = Not Conducted (e) - = Not regulated () ** = Qualitative analysis (no unit) (g) MDL= Method Detection Limit (h) Negative = Undetectable / Positive = Detectable
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 5 o 15 Test results by chemical method: Test Item (s): Unit Method Result MDL Hexabromocyclododecane (HBCDD) Based on EPA 3540C, and perormed by GC-MS N.D. 10 Phthalates --- --- --- --- DBP (Di-butyl phthalate) % DEHP (Di-(2-ethylhexyl phthalate) % BBP (Benzyl Butyl phthalate) % DINP (Di-isononyl phthalate) % DIDP (Di-isodecyl phthalate % DNOP (Di-n-octyl phthalate) % DNHP (Di-n-hexyl phthalate) % DMEP (Bis(2-methoxyethyl)phthalate) *Di-isobutyl phthalate (DIBP) % Test Part Description: Sample Description : Au Bonding Wire % With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. With reerence to Chromatographia Vol.47, No.784, 1998. Analysis was perormed by GC/MS. Note : (a) = ppm (b) N.D. = Not Detected (c) MDL = Method Detection Limit (d) --- = Not Conducted (e) * = The above result is extracted rom the Report No. CTSSA/22889/13 N.D. 0.003 N.D. 0.003 N.D. 0.003 N.D. 0.01 N.D. 0.01 N.D. 0.003 N.D. 0.003 N.D. 0.003 N.D. 0.003
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 6 o 15 Test Part Description : Sample Description : Au Bonding Wire Test results: Test Item (s): Unit Method Result MDL Dimethyl Fumarate (CAS No. 624-49-7) Perluorooctane sulonates (PFOS) PFOS Acid, Metal Salt, Amide PFOA (CAS No.: 000335-67-1) *Phosphorus (P) *Polychlorinated Naphthalene (PCNs) *Polychlorinated Terphenyls (PCTs) With reerence to US EPA 3550C method. Analysis was perormed by GC/MS. With reerence to US EPA 3540C: 1996 method or PFOS content. Analysis was perormed by LC/MS. With reerence to US EPA 3540C: 1996 method or PFOA content. Analysis was perormed by LC/MS. With reerence to US EPA Method 3052 or Phosphorus Content. Analysis was perormed by ICP-AES With reerence to US EPA 3540C method. Analysis was perormed by GC/MS With reerence to US EPA 3540C method. Analysis was perormed by GC/MS N.D. 0.1 N.D. 10 N.D. 10 N.D. 2 N.D. 0.5 Note : (a) = ppm (b) N.D. = Not Detected (c) MDL = Method Detection Limit (d) --- = Not Conducted (e) * = The above tests were subcontracted to SGS Taiwan based on report no. KA/2013/A0723 PFOS Reerence Inormation : POPs (EU) 757/2010 Outlawing PFOS as substances or preparations in concentrations above 0.001% (10ppm), in semi-inished products or articles or parts at a level above 0.1%(1000ppm), in textiles or other coated materials above 1µg/m 2.
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 7 o 15 Test Part Description : Sample Description : Au Bonding Wire TANAKA ELECTRONICS (M) SDN BHD CTSSA/22191/13+KA/2013/A0723 SGS authenticate the photo on original report only
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 8 o 15 1. DETERMINATION OF CADMIUM CONTENT BY IEC 62321 2008 Sample Receiving and Registration 2. DETERMINATION OF LEAD CONTENT BY IEC 62321 2008 Sample Receiving and Registration Cut sample in small pieces Weight sample (0.2-0.5g) into digestion vessel Acid digestion (Microwave) Totally Dissolved Filtration Analyses by ICP 3. DETERMINATION OF MERCURY CONTENT BY IEC 62321 2008 Sample Receiving and Registration Cut sample in small pieces Weight sample (0.2-0.5g) into digestion vessel Acid digestion (Microwave) Totally Dissolved Filtration Analyses by ICP 5. DETERMINATION OF PBB/PBDE WITH GC-MS BY IEC 62321 2008 Cut sample in small pieces Weight sample (0.5-4.0g) into extraction thimble Soxhlet Extraction with Toluene Filter through 0.45 um membrane ilter Analyses by GC-MS (with appropriate dilution) Cut sample in small pieces Weight sample (0.2-0.5g) into digestion vessel Acid digestion (Microwave) Totally Dissolved Filtration Analyses by ICP 4. DETERMINATION OF HEXAVALENT CHROMIUM BY IEC 62321 2008 Sample Receiving and Registration Sample Preparation Spot-test (Qualitative) Boiling-water-extraction Analyses by UV- Spectrophotometer Test Report 6. DETERMINATION OF HEXAVALENT CHROMIUM BY JIS H 8625 Sample Preparation Hot water extraction Add colour-developing reagent Let stand or 5-10 min Analyses by UV- Spectrophotometer (540 nm)
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 9 o 15 DETERMINATION OF HALOGEN CONTENT Sample pretreatment Weighting and putting sample in cell Combustion / Absorption Dilution to ixed volume Analyses by IC MICROWAVE ASSISTED ACID DIGESTION OF ORGANICALLY BASED METRICES (US EPA 3051A) Cut sample in small pieces Weight sample (0.2-0.5g) into digestion vessel Acid digestion (HNO 3) Microwave Totally Dissolved Filtration Analyses by ICP FLOW CHART FOR PVC DETECTION WITH FTIR Sample preparation (apply ATR or analysis) FT-IR Scanning Report
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 10 o 15 DETERMINATION OF HBCDD CONTENT BY IEC 62321 2008 Cut sample in small pieces Weight sample (0.5-4.0g) into extraction thimble Soxhlet Extraction with Toluene Filter through 0.45 um membrane ilter Analyses by GC-MS (with appropriate dilution)
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 11 o 15 Analytical low chart o Phthalates Content Sample pre-treatment/separation Sample extraction by soxhlet method Concentrate/Dilute Extracted solution Analysis was perormed by GC/MS Data
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 12 o 15 Analytical Flow Chart or Dimethyl Fumarate Sample pre-treatment/separation Sample extraction by organic solvent Concentrate/Dilute Extracted solution Analysis was perormed by GC/MS Data
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 13 o 15 Analytical Flow Chart o PFOS & PFOA Content Sample pre-treatment/separation Sample extraction by soxhlet method Concentrate/Dilute Extracted solution Analysis was perormed by LC/MS Data
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 14 o 15 1) These samples were dissolved totally by pre-conditioning method according to below low chart. 2) Name o the person who made measurement: Alex Chang 3) Name o the person in charge o measurement: Ray Chang Flow Chart o digestion or the elements analysis perormed by ICP-AES Cutting / Preparation Sample Measurement Acid digestion by suitable acid depended on dierent sample material (as below table) Filtration Solution Residue 1) Alkali Fusion 2) HCI to dissolve ICP-AES Steel, copper, aluminium, solder Aqua regia, HNO 3, HCI, HF, H 2 O 2 Glass HNO 3 /HF Gold, platinum, palladium, ceramic Aqua regia Silver HNO 3 Plastic H 2 SO 4, H 2 O 2, HNO 3, HCI Others Any acid to total digestion
Test Report No. CTSSA/22191/13+KA/2013/A0723 Date : 01/11/2013 Page: 15 o 15 Chlorinated Flame retardant analytical Flow Chart 1) Name o the person who made measurement: Anson Tsao 2) Name o the person in charge o measurement: Ray Chang Reerence method: US EPA 8270D, US EPA 3540 Test Item: PCNs, PCTs, Mirex Sample pretreatment Sample extraction by organic solvent Concentrate/Dilute the Extracted solution Analysis was perormed by GC/MS Data **** End o Report ****