A Fusion-Product Source. Plasma Fusion Center

Similar documents
The MIT Accelerator for development of ICF diagnostics at OMEGA / OMEGA-EP and the NIF

The MIT accelerator: A fusion product source for ICF diagnostics development and education

DETECTORS. I. Charged Particle Detectors

EEE4106Z Radiation Interactions & Detection

Chem 481 Lecture Material 3/20/09

Gamma and X-Ray Detection

PFC/JA MEASUREMENT OF THE D-D FUSION NEUTRON ENERGY SPECTRUM AND VARIATION OF THE PEAK WIDTH WITH PLASMA ION TEMPERATURE

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

The MIT Nuclear Products Generator for development of ICF diagnostics at Omega / Omega EP and the NIF

MEASUREMENT AND DETECTION OF RADIATION

Chapter Seven (Nuclear Detectors)

The MIT HED Accelerator Facility for Diagnostic Development for OMEGA, NIF, Z, and for Discovery Science

Chapter 11: Neutrons detectors

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

Shielded Scintillator for Neutron Characterization

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Semiconductor Detectors

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Unit 2. Instrumentation. Experts Teaching from Practical Experience

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency

Charged Fusion Product Diagnostic on the Alcator C-Mod Tokamak

The Magnetic Recoil Spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Dipartimento di Fisica, Università degli Studi di Milano-Bicocca, Milano 2. Istituto di Fisica del Plasma, CNR, Milano

Ion Implanter Cyclotron Apparatus System

STATUS REPORT ON THE SIN NEUTRON SOURCE

Journal of Radiation Protection and Research

Quality Assurance. Purity control. Polycrystalline Ingots

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

A Project for High Fluence 14 MeV Neutron Source

A Comparison between Channel Selections in Heavy Ion Reactions

Spectroscopy of light exotic nuclei using resonance scattering in inverse kinematics.

PERSPECTIVES OF PERSONNEL EXTERNAL DOSIMETRY AT STANFORD LINEAR ACCELERATOR CENTER

Diagnosing OMEGA and NIF Implosions Using the D 3 He Spectrum Line Width

Occupational Radiation Protection at Accelerator Facilities: Challenges

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Jeancarlo Torres, CHP. Naval Surface Warfare Center Carderock Division

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

Radiation safety of the Danish Center for Proton Therapy (DCPT) Lars Hjorth Præstegaard Dept. of Medical Physics, Aarhus University Hospital

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

He-3 Neutron Detectors

BALKAN PHYSICS LETTERS Bogazici University Press 15 November 2016 BPL, 24, , pp , (2016)

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Radiation Detection. 15 th Annual OSC Readiness Training Program.

SEARCH FOR COHERENT DEUTERON FUSION BY BEAM AND ELECTROLYSIS EXPERIMENTS

Method of active correlations in the experiment 249 Cf+ 48 Ca n

arxiv:physics/ v1 3 Aug 2006

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

Experimental Activities in China

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

Angular Correlation Experiments

Compton suppression spectrometry

Radiation Detection and Measurement

New irradiation zones at the CERN-PS

Verification of intermediate nuclear fusions without harmful radiation and the production of magnecular clusters

Feasibility Studies for the EXL Project at FAIR *

The scanning microbeam PIXE analysis facility at NIRS

A new detector for neutron beam monitoring

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Neutron Metrology Activities at CIAE (2009~2010)

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Accelerators and radiation spectra

Calibration of a 1.7 MV Pelletron Accelerator at the University of Florida. Ralph Kelly. Department of Physics, University of Florida

Recent activities in neutron standardization at NMIJ/AIST

Rutherford Backscattering Spectrometry

Neutron Generators for Detection of Explosives and Illicit Materials

Recent Developments of Compact Neutron Generators at LBNL

Monte Carlo simulations of neutron and photon radiation fields at the PF 24 plasma focus device

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Non-radioactive radiation sources. Lesson FYSKJM4710 Eirik Malinen

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Measurement of 40 MeV Deuteron Induced Reaction on Fe and Ta for Neutron Emission Spectrum and Activation Cross Section

RADIATION DETECTION AND MEASUREMENT

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Radiation Detection and Measurement

Recent Activities on Neutron Calibration Fields at FRS of JAERI

The photoneutron yield predictions by PICA and comparison with the measurements

Radionuclide Imaging MII Detection of Nuclear Emission

Neutronics Experiments for ITER at JAERI/FNS

Researchers at the University of Missouri-Columbia have designed a triple crystal

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

PHITS calculation of the radiation field in HIMAC BIO

Gas-filled Detectors

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

D- 3 He Protons as a Diagnostic for Target ρr

Nuclear Physics and Astrophysics

Chemical Engineering 412

CCD readout of GEM-based neutron detectors

Los Alamos National Laboratory Facility Review

Detection and measurement of gamma-radiation by gammaspectroscopy

IAP NAN of Ukraine activity in. Possible areas of cooperation in. Roman Kholodov, PICS Meeting, Basivka, Ukraine,

Radiation Detection and Measurement

Transcription:

PFC/JA-92-6 A Fusion-Product Source K. W. Wenzel, D. H. Lo, R. D. Petrasso, J. W. Coleman, C. K. Li, J. R. Lierzer, C. Borris, T. Wei, E. Hsieht and T. Bernatt Submitted for publication in: Review of Scientific Instruments Plasma Fusion Center Massachusetts Institute of Technology Cambridge, MA 02139 t Lawrence Livermore National Laboratory Livermore, CA 94550 This work was supported in part by U.S. DOE Grant No. DE-FG02-91ER54109 and LLNL Subcontract No. B116798.

A Fusion-Product Source K. W. Wenzelt, D. H. Lot, R. D. Petrasso, J. W. Coleman, C. K. Li, J. R. Lierzer, C. Borrds, and T. Wei MIT Plasma Ftsion Center, Cambridge MA 02139 E. Hsieh and T. Bernat Lawrence Livermore National Laboratory, Livermore CA 94550 March 1992 Abstract We refurbished a Texas Nuclear Cockcroft-Walton neutron generator for use as a general fusion-product source. This well-calibrated source is now used routinely for characterizing energetic charged-particle detectors, for the development of nuclear fusion diagnostics, for studying radiation damage, and for calibrating x-ray detectors for laboratory and space plasmas. This paper is an overview of the facility. We describe the main accelerator operating systems, the primary fusion reactions studied, and several diagnostics used to characterize the fusion-product source. 1

I. Introduction The cornerstone of our fusion-product facility is a 170-kV Cockcroft- Walton linear accelerator, located in a radiation vault area with ~3-foot thick concrete walls. Originally manufactured (circa 1962) by Texas Nuclear Corp. (TNC), it is described in Ref. 1. Over the past two years we have refurbished the accelerator in order to use it as a well-calibrated source of fusion products and Particle-Induced X-Ray Emissions (PIXE; described in Ref. 2). In this paper, we emphasize its use as a fusion-product source. We describe in Section II its main components: the target chambers, the vacuum/gas system, and the ion source. Fusion-product generation is described in Section III, and in Section IV we discuss diagnostics used to characterize the emitted radiations. II. Accelerator Systems The TNC device was originally a neutron generator without any direct access to the target vacuum, thereby precluding, for example, the detection of charged fusion products. Our most significant change was to build two new target chambers that allowed detectors to "see" the target, either directly in vacuum or in air through thin windows' (see Fig. 1). The beam is limited by a 1-cm-diameter stainless-steel collimator, electrically insulated from the drift tube, located about 15 cm upstream from the target. The collimator is biased at +300 V to attract secondary electrons 2

created at the collimator edge. Beam current on target is measured by a micro-ammeter connected between the target and ground. The water-cooled target is biased at +200 V to attract secondary electrons generated at the target surface and thus avoid misleading current measurement. The target chamber may be separated from the beam line by a gate valve to allow target changes without bringing the entire accelerator to air. Vacuum is maintained by a Leybold TMP150V turbomolecular pump (which replaces the original ion pump). The base pressure is -0.5-1.O x10~* torr, and the operating pressure ranges from 5 x 10-6 to about 5 x 10- torr depending on beam power, target conditions, and the particular diagnostics installed (e.g., vacuum is degraded when we use an ultra-thin-window gasflow proportional counter to measure low energy x rays). We use high-purity, research-grade gases (H, D, 'He, and 4 He) as beam species, which are fed through electrically insulating tubing to the highvoltage section of the accelerator via a Granville-Phillips 203 variable leak valve. (This replaces the original resistively-heated Pd leak, which only passed hydrogen isotopes.) The ion source consists of a plasma bottle, an extraction electrode, a compression solenoid, and a focus electrode. Plasma is generated in the bottle by 60-MHz RF rings. Ions are forced from the bottle by application of up to +5 kv on the extraction electrode. The magnetic field from the solenoid compresses the plasma and optimizes molecular break-up and gas 3

ionization. 1 After extraction, some beam focusing is achieved by applying up to -10 kv on a focus electrode located just downstream from the ion source. Subsequently the beam is accelerated down the column to the drift tube which houses the target. III. Fusion-Product Generation D-D or D-He reactions are generated by accelerating D or 'He ions onto a deuterated titanium or deuterated erbium target (accelerating voltage ~170 kv; beam current ~300 PA): D + D -+ p(3.0 MeV) + T(1.0 MeV) (1) D + D -+ n(2.5 MeV) +' He(0.8 MeV) (2) D +3 He -+ p(14.6 MeV) + a(3.7 MeV) (3) The maximum reaction rates, normalized to the beam current, are RDD = 9 x 10/(s tpa) and RD3He ~ 3 x 10'/(s pa). In the future we will implement a third target chamber for tritiated targets in order to generate 14.1-MeV neutrons through D-T fusion: D + T - n(14.1 MeV) + a(3.5 MeV). (4) The particle energy observed in the laboratory depends on the beam energy and the angle of observation, 0, relative to the beam direction (see Fig. 1). This kinematic effect makes possible a "tunable" source of monoenergetic particles. (Figs. 2 and 3 show examples.) 4

IV. Cockcroft-Walton Diagnostics Our standard charged-fusion-product diagnostic uses silicon surface-barrier diodes (SBDs) inside vacuum (VSBD), viewing the target at 1200. SBDs have intrinsic detection efficiency of 1.0 and energy resolution of 50 kev for most charged particles, which is sufficient to uniquely identify the charged products of reactions (1)-(3). Thus VSBD provides an absolute calibration of the fusion rate, which was not available with the original target chamber. 1 We typically use a partially-depleted SBD covered with a 1.5-Am-mylar filter to protect it from backscattered beam particles. However, this precludes the detection of 0.8-MeV D-D 'He particles, because they lose most of their energy in the mylar. 4 Another limitation of partially-depleted SBDs (typical thickness -300 pim) is that they cannot measure the full energy of the 14.6 MeV D- 3 He proton (its range is about 1300 pim in silicon"). In order to measure this, a 2000-/im thick fully-depleted SBD is used. We are also examining the charged particle emission at other values of 0. For example, Fig. 2 shows spectra of D-D fusion products taken with VSBD at 0 ~ 650 and 0 ~ 1150. The energy of both the proton and triton shifted downward as 0 was increased. The relative neutron flux is monitored with a she or BF 3 thermal-neutron detector inside a moderating cylinder located a fixed distance from the target. Around the target chamber the time-integrated fast- and thermal-neutron doses are also monitored with neutron dosimeters. These detectors provide 5

a quantitative comparison of the total number of neutrons produced during different experiments. This is important for radiation damage experiments, where the total dose on a sample is the important parameter. We have used both 'He and 4He proportional counters to measure fast neutron spectra. Fig. 3 shows 'He proportional-counter fast-neutron spectra taken at B ~_40* and 0 ~140*. For incident neutrons with energy E,, each spectrum consists of three primary features: 6 (1) the thermal peak (TP at the capture reaction Q-value, 765 kev) and the corresponding wall-effect contributions; (2) the 'He recoil edge at 75% of E, (RE); and (3) the fast neutron capture peak (FP at Q + Es). Table 1 compares the measured fast neutron energies with the values calculated based on kinematics for B = 40*, 90*, and 140'. The measured and calculated neutron energies agreed to within about 5%. X rays are generated in the Cockcroft-Walton via two mechanisms. First, PIXE generates characteristic line radiation from the target material (typically with energy <20 kev) 3. Second, a very much smaller but undesired x-ray flux is generated near the ion source when secondary electrons are accelerated back up to the high voltage section, generating high-energy bremsstrahlung in the process. We measure PIXE x-ray spectra with a Si(Li) detector for x rays with energy ~1 kev, and thin-window gas-flow proportional counters for x rays with energy ~1.5 kev.' We also monitor x rays from secondary electrons 6

using both active (electronic) and passive x-ray detectors. As passive x- ray detectors, we use x-ray dosimeters located around the accelerator room. These monitors are read and recorded before and after each run. As an active x-ray detector, we use a Centronic IG1 ionization chamber located near the ion source. The accelerator generates -y rays via low-probability branches of fusion reactions (e.g., 3 He(D,-y)rLi, "B(p,-y)1 2 C or 7 Li(p,-y) 8 Be). These reactions are used as well-calibrated high-energy y-ray sources for characterizing -y-ray diagnostics, 7 such as NaI(Tl) scintillators or a High-Purity Germanium highresolution spectrometer. As an illustration, Fig. 4 shows the y-ray spectrum taken with a NaI(TI) scintillator from the 7 Li(p,-f) 8 Be reaction. Acknowledgements Dr. Ramon Leeper and Dr. Carlos Ruiz of Sandia National Laboratory and Dr. Lynn Provo of General Electric provided several deuterated erbium targets used in this work. We appreciate Dr. Fredrick Seguin's careful reading of the manuscript. This work was supported by LLNL Subcontract B116798, U.S. DOE Grant No. DE-FG02-91ER54109, by the U.S. DOE Fusion Energy Postdoctoral Fellowship t, and by the U.S. DOE Magnetic Fusion Energy Technology Fellowshipt. 1. J. T. Prud'homme, Texas Nuclear Neutron Generators, Texas Nuclear Corp. Publication No. 5845 (1962). 7

2. C. K. Li, K. W. Wenzel, R. D. Petrasso et al. submitted to Rev. Sci. Instrum. (1992). 3. J. W. Coleman, K. W. Wenzel, C. K. Li et al., Rev. Sci. Instrum. 61, 3234 (1990). 4. To measure low-energy D-D 'He particles with VSBD, we use either a 0.5 I.m mylar filter and maintain the beam voltage at ~40 kv, or no filter and maintain the beam voltage at ~25 kv in order to reduce backscattered beam counts in the VSBD. 5. D. H. Lo, R. D. Petrasso, K. W. Wenzel et al., submitted to Rev. Sci. Instrum. (1992). 6. M. J. Loughlin, J. M. Adams, and G. Sadler, Nucl. Instrum. and Meth. A294, 606 (1990). 7. K. W. Wenzel, R. D. Petrasso, D. H. Lo et al., submitted to Rev. Sci. Instrum. (1992). 8

Table 1: D-D neutron energies, calculated (on the basis of beam/target kinematics and neutron scattering on 3 He) and measured (with a 3 He proportional counter; all in MeV). The measured values agree to <5% with the predictions 0 Measured Predicted Measured Predicted Full Energy Full Energy I Recoil Edge Recoil Edge 400 3.57 3.60 1.92 2.13 900 3.23 3.25 1.69 1.87 1400 3.01 2.95 1.58 1.64 9

VACUUM SBD CERAMIC BREAK COLLIMATOR BIAS WATER IN OU BEAM- A fg10 SWATER OUT VIEWPORT Fig. 1. Schematic diagram of the target chamber. The water-cooled target and the collimator are positively biased to restrain secondary electrons from leaving. The beam current on target is measured directly. A surface barrier diode at angle 9 is operated in vacuum to detect charged fusion products. 10

1100 1000 C, 0 U 900 800 700 600 500 400 300 200 - -. - I - -.I - -1 - - -~ 100 - - 0 0. 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Energy (MeV) Fig. 2. D-D charged-particle spectra were measured with a vacuum SBD at 0 ~65* (solid spectrum) and 0 ~115* (dotted spectrum). Higher energies were measured when the SBD viewed the target from a "forward" angle (i.e., a < 900). 11

I I I I I 1 ~IU TP 105 104 RE 10 e= C -C -- FP 2 U 103-10 L 0.102 101 -c e=1400 0 10 100 100 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Energy (MeV) Fig. 3. 'He proportional-counter fast-neutron spectra were measured at 0 ~ 40* and 0 ~ 140*. An energy calibration was obtained by using the thermal capture peak (at 765 kev) and the lowest edge due to the wall effect (at 191 kev). The "fast peak" (FP) and the recoil edge (RE) are at higher energies for forward angles (see Table 1). 12

105 104 4 0 K C C 103 2 0 8TI LO -c -10 oi2 o 101 100 3 2 4 6 8 10 12 14 16 18 20 Energy (MeV) Fig. 4. The -y rays (at 17.3 and 14 MeV) from the 7 Li(p,-y)aBe reaction were measured with a 3" x 3" Nal(Tl) scintillator. A natural lithium target was used, but the 5.6-MeV 'Li(p,-y) 7 Be -y rays were not observed in the NaI(Tl) data because of the small y-ray branching ratio. (The background lines of 'K and 2 "T1 are also present at 1.46 MeV and 2.61 MeV respectively.) 13