PLUS. Zeta/Nano Particle Analyzer

Similar documents
The solution for all of your

Particle Characterization Laboratories, Inc.

Electrophoretic Light Scattering Overview

Review: ISO Colloidal systems Methods for zeta potential determination

South pacific Journal of Technology and Science

Methods for charge and size characterization colloidal systems

How DLS Works: Interference of Light

Nanoparticle Analyzer

Litesizer Sheet 1. [Home]

Single Nano Particle Size Analyzer

Seeing the Nano-scale: Nanoparticle Tracking Analysis HVM MNT Expo 2006 Oxford. Jeremy Warren CEO, NanoSight Ltd

ENV/JM/MONO(2015)17/PART1/ANN2

STABILITY OF PIGMENT INKJET INKS

How to measure the zeta potential of individual Nanoparticles (NPs)? To anticipate the answer: With the

Particle Analysis at the Touch of a Button. Litesizer series

Size and Zeta Potential of Colloidal Gold Particles

Introduction to Dynamic Light Scattering for Particle Size Determination

Scattering intensity fluctuations

Zeta Potential Analysis using Z-NTA

Electrophoretic Deposition. - process in which particles, suspended in a liquid medium, migrate in an electric field and deposit on an electrode

Particle Concentration Particle Size Zeta Potential

Nanoparticle Tracking Analysis; Sizing, Counting and Visualizing of Nanoparticles. Dr Bob Carr, Founder and CTO NanoSight Ltd

Low-coherence heterodyne photon correlation spectroscopy

Introduction to Nanoparticle Tracking Analysis (NTA) Measurement Principle of ZetaView

Particle Charge Titration Zeta Potential Size Distribution

Suspension Stability; Why Particle Size, Zeta Potential and Rheology are Important

Using the Zetasizer Nano to optimize formulation stability

Amended Specifications as per the Pre Bid meeting held on in Chapter 4

Introduction to Dynamic Light Scattering with Applications. Onofrio Annunziata Department of Chemistry Texas Christian University Fort Worth, TX, USA

Particle Size Determination with Dynamic Light Scattering DLS

Particles, drops, and bubbles. Lecture 3

A dispersion (system) Colloidal solutions High molecular mass compounds

Zeta potential - An introduction in 30 minutes

Engineering Nanomedical Systems. Zeta Potential

Separation Sciences. 1. Introduction: Fundamentals of Distribution Equilibrium. 2. Gas Chromatography (Chapter 2 & 3)

Introduction to Zeta Potential Measurement with the SZ-100

200 to +200mV. Particle Diameter Measurement Range 0.3nm to 8µm. Zeta Potential Measurement. Molecular weight to g/mol

An Overview of the Concept, Measurement, Use and Application of Zeta Potential. David Fairhurst, Ph.D. Colloid Consultants, Ltd

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

Particle Tracking on. Exosomes. ZetaView. Multiparameter NTA sizing, counting and zeta potential. C. Helmbrecht and H. Wachernig

Single action pressing (from top)

Visualize and Measure Nanoparticle Size and Concentration

Measuring Lysozyme Monomer at 0.1 mg/ml Concentration. Equipment used : Sample Preparation and Measurement :

RHEOLASER LAB MICRORHEOLOGY & END USE PROPERTIES ANALYSIS. MICRORHEOLOGY

The Dangers of Dilution When Measuring Water Based Pharmaceutical Suspensions and How Nanoflex Overcomes these Obstacles

NANO-flex 180 DLS nanoparticle sizing. Laser. Scattered light from particles. Size & concentration vol%

*blood and bones contain colloids. *milk is a good example of a colloidal dispersion.

NanoParticle Tracking Analysis The NANOSIGHT system.

ANALYSIS OF LOW DENSITY PARTICLES USING DIFFERENTIAL CENTRIFUGAL SEDIMENTATION

Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

DYNAMICS OF SUSPENDED COLLOIDAL PARTICLES NEAR A WALL

Coherent X-ray Scattering and X-ray Photon Correlation Spectroscopy

LUMiSizer. Dispersion Analyser. The All-in-One. Dispersion Analyser. Stability Demixing Consolidation Particle Sizing

The CMP Slurry Monitor - Background

FRITSCH NANO PARTICLE SIZER IDEAL FOR PIGMENTS CHEMICALS PETROCHEMISTRY FOODSTUFFS PHARMACEUTICALS ENVIRONMENT COSMETICS DYNAMIC LIGHT SCATTERING DLS

Zetasizer Nano ZSP: A Perfect Tool For Life Science Applications

Applied Surfactants: Principles and Applications

Introduction to Differential Sedimentation

Overview. Lecture 5 Colloidal Dispersions

VASCO Flex TM Remote Particle size Analyzer

Particle Analysis at the Touch of a Button. Litesizer series

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

Amorphous Polymers: Polymer Conformation Laboratory 1: Module 1

Foundations of. Colloid Science SECOND EDITION. Robert J. Hunter. School of Chemistry University of Sydney OXPORD UNIVERSITY PRESS

Stability of colloidal systems

Particles in displays

Aadil Zayid. Submitted in partial fulfilment of the requirements for the degree of Master of Applied Science

What is the value of multi-angle DLS?

PHOTOELECTRON SPECTROSCOPY IN AIR (PESA)

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

An introduction to particle size characterisation by DCS:

Interaction of Gold Nanoparticle with Proteins

CPS Instruments Europe P.O. Box 180, NL-4900 AD Oosterhout, The Netherlands T: +31 (0) F: +31 (0) E:

Contents. Preface XIII

Measuring sub-50nm particle retention of UPW filters

Aggregation and Deposition Behavior of Carbon-Based Nanomaterials in Aquatic Environments

ELECTROPHORESIS SLAB (THIN LAYER GEL) AND CAPILLARY METHODS. A. General Introduction

Wave Motion and Sound

Pigment Particle Size Using Microtrac Laser Technology

Lab Week 4 Module α 3. Polymer Conformation. Lab. Instructor : Francesco Stellacci

The ultimate in desktop particle characterization

Measuring particle aggregation rates by light scattering

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

The ultimate in desktop particle characterization

Colloidal Dispersions

Fresnel Equations cont.

MicroBrook Eyetech. Particle Size, Shape, and Concentration Analyzer. Particle Sizing. Particle Concentration. Particle Shape

Particle Size and Rapid Stability Analyses of Concentrated Dispersions

Measurement of Particle Size Distributions

Part 8. Special Topic: Light Scattering

ISO Colloidal systems Methods for zetapotential. Part 1: Electroacoustic and electrokinetic phenomena

THE ZETASIZER FAMILY OF DISPERSION TECHNOLOGY SYSTEMS

Colloidal Materials: Part III

Sanitary Engineering. Coagulation and Flocculation. Week 3

Correlation Spectroscopy in Polymer Physics Methodenseminar im Wahlpflichtfach Basics diffusion and brownian motion correlations functions

Colloid stability. Lyophobic sols. Stabilization of colloids.

CH676 Physical Chemistry: Principles and Applications. CH676 Physical Chemistry: Principles and Applications

Advances in particle concentration measurements

1. The Classification of Dispersion Systems 2. Lyophobic Colloids 3. The Stability and Coagulation of Dispersion Systems 4. Properties of Colloids

Transcription:

PLUS Zeta/Nano Particle Analyzer

-100 m The NanoPlus Zeta-Potential & Particle Size Analyzer Features ELSZ-1000 series ZETA-POTENTIAL & PARTICLE SIZE ANALYZER of ink for inkjet printer (Yellow) Concentration range -200~200mV 0.6~10000nm 0.00001~40 150 100 50 0-50 -100-150 -200-250 mv) oncentration dependence of latex suspension FEATURES Accurate measurement for dilute and concentrated suspension Easy-to-use cells and user friendly software Reliable measurement based on electroosmosis profile estimation Evaluation of surface charge on solid-plate, film and etc. Micro-volume disposable cell Wide size range(0.6nm~10000nm), wide concentration range (0.00001%~40%) Combination of linear and log-scale correlator covers various sample characteristics Well-established technique comform to ISO 13321 : analysis-photon correlation spectroscopy Micro-volume cell CELL LINE-UP distribution of thiamine prob(%) 6 4 2-80 -60-40 -20 0 0 0.0001 0.001 0.01 0.1 1 10 100 solid content 500 400 300 200 100 ave,diameter 0.6nm diameter nm Sizing Standard cell (Flow cell) Micro volume disposable cell High concentration cell Low conductivity cell Solid sample cell Sizing cell Disposable cell Micro volume cell Flow cell 0 0.1 1 10 100 diameter(nm)

High-resolution analysis of zeta-potential Resolution of zeta-potential measurement is so high as to enable multi-component analysis owing to calculation of correlation and FFT calculation with the software. Mixture of five polystyrene latex of different particle size is measured. Five spectrum correspounding to each latex are appeared. of five components are in the range of -45mV to -107mV, and they show good cosistent with that from individual measurement. Zeta potential of Polystyrene latex mixture Evaluation of surface charge of solid plate Using the solid-plate sample cell, surface charge of solid sample can be estimated (1)Zeta potential of glass plate charged to negative (Blank) surface charge = -58.4mV (solvent:1mm NaCl solution) (2)Surface charge of glass is neutralized by positive charge of cethyl trimethyl ammonium bromide (CTAB) surface charge = +1.3mV (solvent:1mm NaCl solution containing 1 x 10-5mol/l CTAB) (3)Surface charge of glass change to positive owing absorption of excess CTAB surface charge = +48.4mV (solvent F1mM NaCl solution containing 1 10-5mol/l CTAB)

Evaluation of dispersion stability by zeta-potential/particle size As the absolute value of zeta-potential is larger, general colloidal particles show good dispersibility, as the electrostatic repulsion becomes stronger. As the zeta-potential is close to zero, they become so unstable as to be likely to aggregate. Typical NanoPlus Applications Neutralization of charge Nano Material / Nano Technology Charge (Dispersion Stable) (Unstable Aggregation) As the ph value of the solution changes from acidic to alkaline values, alumina particles show a large change of the zeta-potential from plus to minus values. It can be seen that they have the isoelectric point to indicate the zero zeta-potential at around ph9. In the ph range where the absolute value of zeta-potential is large, their average particle size is small, and it can be seen that dispersion stability of the particles is good due to electrostatic repulsion. On the other hand, it can be seen that particles aggregation to be large in the average particle size, resulting in instability, in the area around the isoelectric point. σ-zeta potential Researches for fuel cells (carbon nanotube, fullerene, nano material, etc.) and for nano-bio (dendrimer, DDS, nano-capsule, etc.) Semiconductor Researches for clarification of deposition mechanism of foreign matters on silicon wafer surfaces, and interactions among abrasives, additives and wafer surface Medicine and food Researches for control of dispersion and aggregation of emulations (foods, perfumes, medicines and cosmetics), for functionality of protein, for cintrol of dispersion and aggregation of ribosome, and for functionality of protein, for control of dispersion and aggregation of ribosome, and for functionality of surface active agents (micelle) Ceramic and color material σ-diameter Resarches for control of surface reforming, dispersion and aggregation of ceramics(silica, alumina, titanium oxide, etc.) and inorganic sol, control of dispersion and aggregation of pigments),and for adsorption of collector of floating ores Polymer and chemical Researches for control of dispersion and aggregation of emulsions(paints and adhesives), control of surface reforming of latex(for medicines and industrial use), and for functionality of electrolytic polymers (polystyrene sulfonate, polycarboxyloic acid,etc.) Control of paper and pulp manufacturing process, and researches for pulp additives

The NanoPlus Zeta-Potential & Particle Size Analyzer Principle of Zeta-Potential Measurement In most cases, colloidal particles posses an either positively or negatively electrostatic charge. Having electrical fields applied to that particle dispersion, the particles migrate to oppositely charged direction. Upon particles being irradiated in migrating, scatter light causes Doppler shift depending upon electrophoresis mobility. ELSZ-1000 software calculates Doppler shift amount followed by electric mobility and zeta potential by combining heterodyne system and photon correlation method to perform Fourier transform (FFT) of obtained correlation function. v Doppler shift Velocity of particle movement Refractive index Viscosity v = 2Vn sin( /2)/ U = V/E = 4 U/... Smoluchowski equation Slipping level Detect angle Wavelength of incidence light Electrophoretic mobility Major part of medium Ion diffuse layer Fixed layer Colloidal particle Electric field Dielectric constant Electrophoresis Incident beam Concept of FST method By conventional method, scattered light from concentrated suspention can not be measured correctly due to multiple scattering (A). FST method developed recently detects the scattering light at forward direction through the transparent electrode. Optical path lengh of its detection is minimized to reduce the influence of multiple scattering. Thus, it can perform zeta-potential measurement of concentrated suspension with high accuracy (B). FST*: Electrophoretic mobility measurement of concentrated suspension using Forward Scattering through Transparent electrode. * patent pending Cell Transmission Scattering Incident beam Scattering Determination of true electrophoretic mobility (A) Standard cell (B) High concentration cell When measurement of electrophoresis is actually taken, electroosmotic current is generated in the cell due to electric charge on the cell wall. The electroosmotic current means a phenomenon that, in the case of the cell wall charged to minus, ions and particles of plus electric charge gather together around the cell wall, so that the solution located around the wall faces migrates toward the minus electrode direction during electrophoresis and the solution located at the cell center follows in the opposite plus electrode direction to compensate the flow in the plus electrode direction. Accordingly, electroosmic current is added to the apparent electrophoreis of particles observed. The ELSZ-1000 series apparatuses are designed to measure the electrophoretic mobility at severall points in the cell to thereby obtain a position not influenced by the electroosmotic current, i.e.static surface,and then calulate the true mobility at the position. As a result, the moblity can be measured at high accuracy, even if the electroosmotic profile of the system is asymmetrical due to adsorption or sedimentation of the sample. Principle of particle sizing Particulates dispersed in a solution are normally performing the Brownian motion. The motion is slower as the particles are larger and is faster as the particles are smaller. This principle is applicable namely when laser beams are irradiated to particles under the Brownian motion, scattered light from the particles shows fluctuation corresponding to individual particles.the fluctuation is observed according to the pinhole type photon detection method, so that particle size and particle size distributions are calculated. G 2 ( ) = 1+ (G 1 ( )) 2 G 1 ( ) = exp(-dq 2 ) d = kt/3 D... Stokes-Einstein equation cell wall cell wall Stationary layer apparent mobility at position (Z) True mobility electroosmosis flow at position (Z) G 1 ( ), G 2 ( ): Secondary and primary auto-correlation function(acf) : Diffusion coefficent : Scattering vector : Correlation time : Hydrodynamic diameter Incident beam APD(Avalanche Photo Diode) : Boltzmanns constant : Absolute temperature : Viscosity of medium Measurement cell Pinhole 1 Pinhole 2 (Colloid particle in Brown motion) Difference of scattering intensity and autocorrelation function(acf) between various sized particles Intensity Intensity Intensity and ACF of small particles Fluctuation of scattering light T Scattering light fluctuate fiercely Intensity and ACF of large particles Fluctuation of scattering light T Scattering light fluctuate moderately ACF The smaller particle is, the quicker ACF is decaying Correlation time ACF The larger particle is, the slower ACF is decaying Correlation time

Component NanoPlus-1 Particle Size Analyzer, Computer, Monitor, Size Cell NanoPlus-2 Zeta Potential Analyzer, Computer, Monitor, Flow Cell, Disposable Cell Principle Photon Correlation Spectroscopy Laser Doppler Method NanoPlus-3 Particle Sizing & Zeta Potential Analyzer, Computer, Monitor, Size Cell, Flow Cell, Disposable Cell Laser Doppler Method & Photon Correlation Spectroscopy Light Source Semiconductor Laser Semiconductor Laser Semiconductor Laser Detector Avalanche Photodiode Avalanche Photodiode Avalanche Photodiode Cell/Sample Volume [Size] Glass Cell(0.9mL~) [Zeta] Flow Cell(0.7mL~), High Concentration Cell(0.6mL~), Disposable Cell(130μL~) [Size] Glass Cell(0.9mL~) [Zeta] Flow Cell (0.7mL~), High Concentration Cell(0.6mL~), Disposable Cell(130μL~) Condensation Range [Size] :0.00001 to 40% [Zeta] 0.001 to 40% [Size] :0.00001 to 40% [Zeta] 0.001 to 40% [Zeta] -200 to 200mV, [Mobility] Measure Range [Size] :0.6nm to 10μm -20x10-4 to 20x10-4 cm 2 /Vs Operation 15 to 35 C 15 to 35 C 15 to 35 C Electricity Requirement AC 100-240V, 50/60Hz AC 100-240V, 50/60Hz AC 100-240V, 50/60Hz Dimention 380(W) x 600(D) x 210(H) mm 380(W) x 600(D) x 210(H) mm 380(W) x 600(D) x 210(H) mm Weight Approx. 22kg Approx. 22kg Approx. 22kg Data Processing Desk Top PC, Windows 7 Desk Top PC, Windows 7 Desk Top PC, Windows 7 Function Principle Auto-Titrator Automatic perform liquid titration for zeta potential measurement Automatic ph control of liquid suspension Operation Temperature 15 to 35 C Electricity Requirement AC 100-240V, 50/60Hz Dimention 250(W) x 310(D) x 290(H) mm Weight Approx. 7kg