Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS)

Similar documents
Chemistry Instrumental Analysis Lecture 37. Chem 4631

Using Different Drift Gases To Change Separation Factors (r) in Ion Mobility Spectrometry

Liquid chromatography/mass spectrometric analysis of explosives: RDX adduct ions

Quantitative and Qualitative Determination of Organics in Water Using Electrospray Ionization Coupled with Ion Mobility Spectrometry

THE NEW ROLE FOR LC/MS AND LC/MS/MS IN EXPLOSIVES INVESTIGATIONS. L. Penfold Severn Trent Laboratories, Inc.

M M e M M H M M H. Ion Sources

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Electrospray Ionization High-Resolution Ion Mobility Spectrometry for the Detection of Organic Compounds, 1. Amino Acids

Supporting Information

Introduction. Chapter 1. Learning Objectives

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Mass Spectrometry in MCAL

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

Supporting Information. Use of Mass Spectrometric Vapor Analysis to Improve Canine Explosive Detection Efficiency

An EZ-DART spectrum was taken for both fifty (SI figure 2a) and twenty (figure 3 and

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

This method describes the identification of the following prohibited colorants in cosmetic products:

Agilent G3212 GC-APCI Source

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

The Theory of HPLC. Quantitative and Qualitative HPLC

Mass Spectrometry. Electron Ionization and Chemical Ionization

METHOD 8330A NITROAROMATICS AND NITRAMINES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

2,5-DIMETHOXY-4-IODOPHENETHYLAMINE Latest Revision: August 22, 2005

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Extrel Application Note

DEVELOPMENT AND OPTIMIZATION OF THE UV REDUCER FOR THE DETERMINATION OF EXPLOSIVES

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Technical Note. Introduction

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D.

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

1. The range of frequencies that a measurement is sensitive to is called the frequency

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

LC-MS Based Metabolomics

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

CHAPTER-2 Formation of Adenine from CH 3 COONH 4 /NH 4 HCO 3 the Probable Prebiotic Route for Adenine

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Ionization Techniques Part IV

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry

Detection and Classification of Explosive Compounds in Presence of Interferents Utilizing Laser Ion Mobility Spectrometry

Fluorescent Chemosensor for Selective Detection of Ag + in an. Aqueous Medium

Studies of the Thermal Degradation of Acetaminophen Using a Conventional HPLC Approach and Electrospray Ionization Mass Spectrometry

Chemistry Gas Chromatography: Separation of Volatile Organics

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

CHEM 429 / 529 Chemical Separation Techniques

Ion-mobility mass spectrometry of polyoxometalate Keplerate clusters and their supramolecular assemblies

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

HPLC Praktikum Skript

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Explosive Screening by Vapour Detection: Operational Aspects

STANDARD OPERATING PROCEDURES

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Experiment 1: Thin Layer Chromatography

Chapter 14. Molar Mass Distribution.

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

*Correspondence to:

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

B.J. Hicks, W. Han TestAmerica Laboratories Rider Trail North, Earth City, MO 63045

Supporting Information

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Lecture 15: Introduction to mass spectrometry-i

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Selecting Detectors for Compounds with No Optical Absorbance

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Lecture 8: Mass Spectrometry

High Performance Liquid Chromatography

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Supporting Information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Ester Synthesis And Analysis: Aspirin and Oil of Wintergreen. Vanessa Jones November 19, 2015 Thursday 8:30 Lab Section Lab Partner: Melissa Blanco

Analysis of Polar Metabolites using Mass Spectrometry

CEE 772: Instrumental Methods in Environmental Analysis

A dual redox-responsive supramolecular amphiphile fabricated by selenium-containing pillar[6]arene-based molecular recognition

GPC/MS. Analysis of PET

Transcription:

Talanta 50 (2000) 1291 1298 www.elsevier.com/locate/talanta Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS) G. Reid Asbury, Jörg Klasmeier, Herbert H. Hill Jr. * Department of Chemistry, Washington State Uni ersity, Pullman, WA 99164-4630, USA Received 6 May 1999; received in revised form 2 August 1999; accepted 3 August 1999 Abstract The analysis of explosives with ion mobility spectrometry (IMS) directly from aqueous solutions was shown for the first time using an electrospray ionization technique. The IMS was operated in the negative mode at 250 C and coupled with a quadrupole mass spectrometer to identify the observed IMS peaks. The IMS response characteristics of trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DNT), 2-amino-4,6-dinitrotoluene (2-ADNT), 4-nitrotoluene (4-NT), trinitrobenzene (TNB), cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), cyclo-tetramethylene-tetranitramine (HMX), dinitro-ethyleneglycol (EGDN) and nitroglycerine (NG) were investigated. Several breakdown products, predominantly NO 2 and NO 3, were observed in the low-mass region. Nevertheless, all compounds with the exception of NG produced at least one ion related to the intact molecule and could therefore be selectively detected. For RDX and HMX the [M+Cl ] cluster ion was the main peak and the signal intensities could be greatly enhanced by the addition of small amounts of sodium chloride to the sprayed solutions. The reduced mobility constants (K 0 ) were in good agreement with literature data obtained from experiments where the explosives were introduced into the IMS from the vapor phase. The detection limits were in the range of 15 190 g l 1 and all calibration curves showed good linearity. A mixture of TNT, RDX and HMX was used to demonstrate the high separation potential of the IMS system. Baseline separation of the three compounds was attained within a total analysis time of 6.4 s. 2000 Elsevier Science B.V. All rights reserved. Keywords: Electrospray ionization; Ion mobility spectrometry; Reduced mobility constants; Baseline separation 1. Introduction Trace analysis of explosives is of major importance in two different fields. One is the threat of an illegal use of these compounds, which has led * Corresponding author. Tel.: +1-509-3355648; fax: +1-509-3358867. E-mail address: hhhill@wsu.edu (H.H. Hill Jr.) to major efforts in developing explosives detection systems [1 3]. The other is growing concern about the health risks associated with the release of explosives from military sites and former ammunition plants into the environment [4 6]. Ion mobility spectrometry (IMS) is one of the most promising analytical techniques currently investigated for the detection of explosives. The major advantages of IMS are its fast response times and 0039-9140/00/$ - see front matter 2000 Elsevier Science B.V. All rights reserved. PII: S0039-9140(99)00241-6

1292 G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 its sensitivity to many of the commonly used explosives due to their strong electron affinity [7]. Although a number of commercial IMS systems are already available, there are still some problems to overcome. The routine use of IMS as a detection method for explosives requires a reproducible response produced by clearly identified ions. The ion chemistry of the compounds, however, is different depending on the operation conditions (e.g. ionization method, drift tube temperature, drift gas) of the IMS system. Published IMS spectra often differ significantly due to temperature effects and the addition of reactants to the drift gas [8,9]. Hitherto, several different ions have been reported including molecular ions of the form M or [M-H], multi-component cluster-ions (e.g. [M+Cl ] or [M+NO 3 ] ) and fragment ions (e.g. NO 3 ). The exact nature of the species formed in the IMS can only be decisively determined using an IMS/MS combination. Thermally labile compounds like NG and EGDN tend to decompose at elevated temperatures and often only non-specific fragment ions (e.g. NO 2 and NO 3 ) are observed [1]. As hightemperature operation of the IMS provides several advantages such as, eliminating interference problems and enhancing the sensitivity, it would be desirable to establish such a system for the determination of explosives. The use of electrospray ionization (ESI) instead of the standard 63 Ni ionization source could also be advantageous. The combination of ESI with mass spectrometry (MS) has already been successfully applied to the analysis of explosives [10,11]. In our lab, recently a novel, cooled electrospray ionization system has been developed for the use with IMS. This enables the direct analysis of aqueous samples [12,13]. This methodology could provide a helpful tool for the screening of water samples suspected to be contaminated with explosives. Using our ESI-IMS-MS, we investigated the response characteristics and the detection limits for a number of different explosives. The mass spectral data were used to identify the IMS peaks to enable a comparison of the calculated K 0 -values with literature data. Also the ion patterns observed for RDX and HMX were compared to results of previously published ESI-MS studies. 2-ADNT, one of the initial metabolic intermediates of TNT formed after release of TNT into the environment [5], was included in the study to address the possible tracing of environmental contamination with an IMS method. 2. Experimental 2.1. Chemicals and sol ents The explosives used in this study included 2,4,6- trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4- DNT), 1,3,5-trinitrobenzene (TNB), 2-amino-4,6- dinitro-toluene (2-ADNT), 4-nitrotoluene (4- NT), cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), cyclo-tetramethylene-tetranitramine (HMX), ethyleneglycol-dinitrate (EGDN), and nitroglycerin (NG). All compounds were purchased as standards in sealed ampoules from either Supelco (Bellefonte, PA) or Radian International (Austin, TX). They came dissolved in acetonitrile at a concentration of 1000 mg l 1 and were diluted with methanol water (9:1, v/v) to 10 mg l 1 or less. Solutions containing sodium chloride or ammonium acetate were prepared by diluting the stock standard solutions with an appropriate solution of the respective salt in methanol water (9:1, v/v). All solvents used were reagent grade (J.T. Baker, Phillipsburg, PA). 2.2. Instrumentation The ESI/IMS/MS-system was constructed at Washington State University and has been described in detail elsewhere [12,13]. A total spray voltage of 2500 V was applied to the electrospray unit. The electrospray needle was kept cool by water cooled nitrogen flowing along the axis of the needle at a flow rate of about 60 ml min 1. This cooling process was necessary to eliminate solvent evaporation inside the needle prior to electrospray. A continuous flow of solvent (methanol water, 9:1, v/v) through the ESI source was provided by a dual piston syringe

G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 1293 pump (Brownlee Labs, Santa Clara, CA) with a flow rate of 5 l min 1. Samples were injected via a six-port injector (C6W, Valco Industries, Houston, TX) with an external injection loop. A detailed description of the IMS unit can be found in Wu et al. [13]. The instrument was operated in the negative mode, as explosives tend to produce negative ions. The electric field strength in the desolvation region and the drift region was 280 V cm 1 with a total drift voltage of 3650 V. The drift tube was operated at 250 C at atmospheric pressure. A counterflow of preheated dry nitrogen (800 ml min 1 ) was introduced as drift gas at the end of the drift region. This drift gas was further used to desolvate the electrosprayed ions in the desolvation region. The ion mobility spectrometer was interfaced to a C50-Q quadrupole mass spectrometer (ABB Extrel, Pittsburgh, PA 15238). The ions entered the MS via a 40-micron pin hole leak which served as the barrier between the atmospheric pressure of the IMS tube and the vacuum of the mass spectrometer. All mobility data was collected by replacing the stock preamplifier with a Keithley 427 amplifier (Keithley Instruments, Cleveland, OH) and sending the amplified signal to the data acquisition system, which was constructed at WSU. A detailed description of the IMS control and data acquisition system can be found in [12]. All of the IMS spectra shown in this paper were the average of 256 individual spectra. Mobility spectra were collected in a non-selective and a mass selective mode. In the non-selective mode all ions were allowed to pass the mass filter, whereas in the mass selective mode the mass spectrometer was set to allow only a single m/z to pass. All identifications of distinct ions were based on the mass spectral data. 3. Results and discussion 3.1. Low-mass background and breakdown ions Fig. 1. Background ions in the low-mass region of the IMS monitored for pure solvent (a), a solution of 10 mg l 1 RDX (b) and a solution of 2 mm NaCl in the solvent (c). Notation: 1, chloride (Cl ); 2, nitrate (NO 3 ); 3, formate (HCOO ); 4, nitrite (NO 2 ); 5, acetate (CH 3 COO ); 6, probably nitrite adduct (CH 3 OH+NO 2 ); 7, cluster of at least two unidentified ions (m/z 89 and 97). The low-mass region of the IMS spectra was studied in some detail in order to better characterize the high temperature atmospheric pressure ESI/IMS and its ion chemistry. The top spectrum of Fig. 1 shows the background signal of the IMS when spraying pure solvent. There are three distinct peaks (c1, c3, c5), which were identified by mass analysis to be Cl, HCOO, and CH 3 COO, respectively. These ions are most likely formed by ESI from trace impurities of the solvents (e.g. acetic acid, chloride salts). The middle spectrum of Fig. 1 shows the peaks observed in the low-mass region with a solution of RDX (10 mg l 1 ). Besides the three background peaks a number of other peaks appeared. Peaks labeled c2 and c4 were identified as nitrite and nitrate. They were probably formed by thermal breakdown of RDX in the hot desolvation region. All of the investigated explosives produced significant amounts of these two ions, which is not surprising since most of the compounds are thermally labile [1].

1294 G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 reduction of the other background ions is probably a result of charge competition. 3.2. IMS spectra of standard solutions of explosi es Fig. 2. Ion mobility spectra of eight explosives with low mass filter set to 140. Concentration of standard solutions was 10 mg l 1 in methanol water (9/1, v/v), 2 mm NaCl was added for RDX and HMX. M/z values can be seen in Table 1. The peak labeled c6 has a mass of 78 amu and is suggested to be a (CH 3 OH+NO 2 ) adduct ion. The final peak (c7) appears to be a cluster of different ions. The mass spectral analysis revealed that it contains at least two ions with m/z 89 and 97. The identity of these peaks is speculated to be adducts of nitrite and nitrate with other breakdown products. The same mass peaks have been previously observed in an ESI/MS study, but were also unidentified [11]. The bottom spectrum of Fig. 1 shows the lowmass region for pure solvent containing 2 mm sodium chloride. As expected the chloride peak ( c1) dominates this spectrum. The simultaneous The different explosives were sprayed out of standard solutions at concentrations of 10 mg l 1 each. The respective spectra are shown in Fig. 2. They were taken with the low-mass filter set to 140, effectively eliminating any ions in the lowmass region from reaching the detector. Furthermore it should be noted that the spectra shown for RDX and HMX were taken with the addition of 2 mm NaCl to the standard solution, predominantly forming (M+Cl ) adduct ions (see discussion below). In the case of nitroglycerine only breakdown product ions (mainly nitrate) were produced and no ions could be detected in the high mass region. The thermal instability of NG in traditional IMS systems at temperatures above 150 C is known and has been reported before [1,9]. Obviously this is also valid for the ESI/IMS system at 250 C. TNB showed at least three different peaks with the M (m/z 213) being the dominant one. Mass spectral analysis revealed m/z values of 178 and 244 for the two other peaks seen in the IMS spectrum. The latter is speculated to be a (M+ CH 3 CO ) adduct formed by the molecule clustering with the methanol solvent. All the other compounds showed only one main peak being either (M-H) or M. The reduced mobility constants (K 0 ) of the dominant peaks for each compound were calculated and are listed in Table 1. It can be seen that they are in good agreement with previously reported literature values obtained from experiments where the compounds have been introduced into the IMS as vapors. 3.3. Sensiti ity enhancement by addition of Cl It is known that the sensitivity of IMS systems using a 63 Ni foil as ionization source to certain explosives can be enhanced by adding chlorinated reactants (e.g. dichloromethane) to the carrier gas [1,3,9]. This phenomenon has not yet been investigated with electrospray ionization. In our experi-

G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 1295 Table 1 K 0 -values of different product ions of the investigated compounds compared to literature data Compound m/z Species LoD ( g l 1 ) K 0 (cm 2 V 1 s 1 ) a Reference TNT 226 (M-H) 15 1.48 1.54 (N 2 ) [8] 1.45 (air) [1 3] 2 ADNT 196 (M-H) 16 1.57 2,4 DNT 181 (M-H) 26 1.62 1.67 (N 2 ) [8] 1.57 (air) [1] 4-NT 136 (M-H) 1000 1.79 1.81 (air) [8] TNB 244 (M+CH 3 O ) n.c. 1.42 213 M 1.54 178? 1.65 RDX 257 (M+Cl ) 40 1.40 1.39 (air) [2,3] HMX 331 (M+Cl ) 86 1.25 1.25 (air) [2] EGDN 152 M 190 1.57 NG 226 (M-H) n.d. 1.45 (air) [2] 262 (M+Cl ) n.d. 1.47 (N 2 ) [9] a First column: measured in this study with N 2 as drift gas. Second column: reference data, drift gas given in parentheses. n.d., not detected; n.c., not calculated; LoD, limit of detection. ments the addition of small amounts of dichloromethane to samples of RDX and HMX showed no significant effects in the IMS, even with respect to the Cl peak. However, a huge increase in the peak intensities for the Cl peak and the (M+Cl ) adduct peak could be achieved by adding sodium chloride to the samples. This seems reasonable taking into account that when using a 63 Ni foil the ions are created in the gas phase from volatile species, whereas electrospray creates the ions in solution from dissolved species. Significant increases in signal intensity for the (M+Cl ) adduct were observed at concentrations as low as 0.02 mm NaCl. The optimal concentration was found to be about 2 mm with an overall increase in signal intensity compared to a pure standard solution of more than one order of magnitude (about 12 times). Figs. 3 and 4 show the different spectra for RDX and HMX with and without the addition of 2 mm NaCl. The increase in the intensity of the chloride peak after adding NaCl can be seen from Fig. 3. No M or (M-H) ions were detected in either case. However, the spectra clearly indicate a significant increase in the peak intensity with the addition of the chloride salt. Apparently, both compounds are able to form stable (M+Cl ) adduct ions with our operating conditions. None Fig. 3. Ion mobility spectra of RDX with (a) and without (b) addition of NaCl (2 mm). Concentration of standard solution was 10 mg l 1 in methanol water (9/1, v/v) each.

1296 G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 refer to the same peak as an acetate adduct (M+ CH 3 COO ) due to the fact that they sprayed standard solutions containing 2 mm of ammonium acetate. With our experimental design we could not achieve any increase in the (M+59)- peak by adding 2 mm of ammonium acetate, but this might well be a temperature effect since the IMS was operated at 250 C. 3.4. Detection limits and linearity of response Fig. 4. Ion mobility spectra of HMX with (a) and without (b) addition of NaCl (2 mm). Concentration of standard solution was 10 mg l 1 in methanol water (9/1, v/v) each. Notation: 1, m/z 334, 2, m/z 331; 3, m/z 341; 4, m/z 355; and 5, m/z 357. of the other explosives produced measurable amounts of (M+Cl ) adduct ions. This is surprising for EGDN, as this compound has been shown to do so in vapor phase IMS systems [1,9]. The top spectra of Figs. 3 and 4 obtained with the pure standards also show the peak for the (M+Cl ) adduct, but the signals are much weaker. Whereas for pure RDX no other ions appeared in the IMS spectrum, HMX showed a couple of additional peaks. M/z of these peaks were identified to be 334, 341, 355 (M+59) and 357. Similar observations were made in previously published ESI/MS studies, but the identity of the respective ions remains in question. Yinon et al [11] labeled the (M+59) as a (M+NNO 2 -H) cluster ion, whereas Casetta and Garofolo [10] With the exception of NG, TNB and 4-NT all explosives produced signals significantly above the noise level (about 300 fa) at a concentration of 10 mg l 1. Detection limits for these compounds were determined as the concentrations giving peak heights three times the noise level. The calculated values for the different compounds are given in Table 1. They were found to vary between 15 190 g l 1 which is similar to detection limits reported for HPLC systems [6,14]. With the parameters used for data acquisition this calculates to absolute IMS detection limits of 8 100 pg, which compares to the lowest reported values for commercial vapor phase IMS systems [1,3]. The calibration curves of the compounds showed excellent linearity over a concentration range of at least two orders of magnitude having r 2 -values greater than 0.99. These results are especially promising with respect to the need of establishing a quantitative IMS determination method for explosives. 3.5. Separation of three common explosi es by IMS A number of different methods for analyzing explosives from complex environmental matrices using liquid chromatographic and gas chromatographic separations have been reported so far [4 6,14,15]. The separation capabilities of ESI- IMS-MS demonstrating a resolving power similar to liquid chromatography has already been demonstrated [13]. As the IMS also shows high sensitivity for many of the explosives, the use of ESI/IMS for analyzing environmental samples was taken into consideration.

G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 1297 The experimental data showed measurable differences in the K 0 -values for most of the compounds (see Table 1). Thus, a mixture of three common explosives at concentrations of 1 mg l 1 (TNT) and 2 mg l 1 (RDX and HMX), respectively was analyzed to evaluate the separation capabilities of the instrument. In order to enhance the sensitivity of the system to RDX and HMX, 2 mm NaCl was added to the mixture. The resulting spectrum is shown in Fig. 5. Although the instrument was not optimized to give the highest possible resolution, the resolving power was sufficient to achieve baseline separation of the three compounds. The actual resolving power calculated from the data was 57 5 for the three peaks. In chromatographic terms, this corresponds to about 18 000 theoretical plates. Additionally, it must be pointed out that the whole separation was achieved in less than 25 ms per single spectrum resulting in a total analysis time of only 6.4 s for averaging 256 spectra. This indicates that ESI-IMS could be a method to rapidly analyze environmental samples for mixtures of explosives at trace concentrations. Further investigations including improvement of resolution and analyzing real samples are currently in preparation. Acknowledgements This project was in part supported by research grants from the Federal Aviation Administration (Grant c97g009) and the U.S. Army Research Office (Grant DAAG559810107). Additionally, an ACS research fellowship was awarded to Reid Asbury sponsored by the Society of Analytical Chemistry of Pittsburgh. References Fig. 5. Ion mobility spectrum of a mixture of TNT (m/z 226), RDX (m/z 257) and HMX (m/z 331) showing baseline separation of these explosives. Concentrations were 1 mg l 1 for TNT and 2 mg l 1 for RDX and HMX in methanol water (9/1, v/v) additionally containing 2 mm NaCl. [1] L.L. Danylewych-May, C. Cummings, Explosive and taggant detection with Ionscan, in: J. Yinon (Ed.), Advances in Analysis and Detection of Explosives, Kluwer Academic Publishers, Dordrecht, 1993, pp. 385 401. [2] R.K. Ritchie, F.J. Kuja, R.A. Jackson, A.J. Loveless, L.L. Danylewych-May, Recent developments in IMS detection technology, in: G. Harding, R.C. Lanza, L.J. Myers, P.A. Young (Eds.), Substance Detection Systems, International Society for Optical Engineering, Bellingham, WA, 1994, pp. 76 86. [3] D.D. Fetterolf, Detection of trace explosive evidence by ion mobility spectrometry, in: J. Yinon (Ed.), Advances in Analysis and Detection of Explosives, Kluwer Academic Publishers, Dordrecht, 1993, pp. 117 131. [4] S. Barshick, W.H. Griest, Anal. Chem. 70 (1998) 3015. [5] S.D. Harvey, H. Galloway, A. Krupsha, J. Chromatogr. A 775 (1997) 117. [6] C.A. Weisberg, M.L. Ellickson, Am. Lab. 30 (1998) 32N. [7] R. Wilson, A. Brittain, Explosives detection by ion mobility spectrometry, in: J.E. Dolan, S.S. Langer (Eds.), Explosives in the Service of Man, Royal Society of Chemistry, Cambridge, 1997, pp. 92 101. [8] G.E. Spangler, P.A. Lawless, Anal. Chem. 50 (1978) 884. [9] A.H. Lawrence, P. Neudorfl, Anal. Chem. 60 (1998) 104.

1298 G. Reid Asbury et al. / Talanta 50 (2000) 1291 1298 [10] B. Casetta, F. Garofolo, Org. Mass Spectr. 29 (1994) 517. [11] J. Yinon, J.E. McClellan, R.A. Yost, Rapid Commun. Mass Spectr. 11 (1997) 1961. [12] D. Wittmer, Y.H. Chen, B.K. Luckenbill, H.H. Hill, Anal. Chem. 66 (1994) 2348. [13] C. Wu, W.F. Siems, G.R. Asbury, H.H. Hill, Anal. Chem. 70 (1998) 4929. [14] U. Lewin, J. Efer, W. Engewald, J. Chromatogr. A 730 (1996) 161. [15] F. Garofolo, V. Migliozzi, B. Roio, Rapid Commun. Mass Spectrometr 8 (1994) 527..