Incremental Sampling Methodology Status Report on ITRC Guidance

Similar documents
Laboratory Support for Multi-Increment Sampling

Better Site Characterization through Incremental Sampling Methodology Mark Bruce Ph. D.

Incremental Sampling Methodology

INCREMENTAL SAMPLING METHODOLOGY

METHOD 3600C CLEANUP

Explosives by HPLC, LC/MS and LC/MS/MS

Best Practices for Obtaining Samples of Known Quality

METHOD 3545A PRESSURIZED FLUID EXTRACTION (PFE)

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

IRTC Incremental Sampling Methodology February 2012

METHOD 3600B CLEANUP

Incremental Sampling Methods: Current VSP Applications for Representative Soil Sampling

Engineer Research and Development Center. Cost and Performance Report of Incremental Sampling Methodology for Soil Containing Metallic Residues

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

ALLOWAY METHOD OUTLINE

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

One Corps Serving the Army and the Nation. Improving the Quality of Environmental Samples

EPAs New MDL Procedure What it Means, Why it Works, and How to Comply

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

Distinguishing between analytical precision and assessment accuracy in relation to materials characterisation

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

TABLE 1 SSFL CHEMICAL SOIL BACKGROUND STUDY DATA QUALITY OBJECTIVES

METHOD 8330B NITROAROMATICS, NITRAMINES, AND NITRATE ESTERS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Measurement Uncertainty: A practical guide to understanding what your results really mean.

GOOD TEST PORTIONS. QA / QC: A Critical Need for Laboratory Sampling

Sources of variability in measuring aflatoxin and the role of sampling

Remote Sensing Techniques for Characterizing Distribution of Impact Area Energetic Compounds

Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures

EPA's Revision to the 40 CFR Part 136 Method Detection Limit (MDL) Procedure

Facilities Management

In room E 28 slightly elevated concentrations of Stachybotrys were found.

Analysis of SVOCs in Indoor Air Using Thermal Desorption GC/MS

Putting the Pieces of the Puzzle Together. By Kim Kirkland, Methods Team Leader EPA s Office of Resource Conservation and Recovery

WACEL AGGREGATE LABORATORY TESTING TECHNICIAN

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

QA/QC IN MINING REALITY OR FANTASY? M. Sc. Samuel Canchaya Exploration Senior Geologist Cía. de Minas Buenaventura S. A. A. - PERU

Laboratory 101: A Guide to Understanding your Testing Laboratory

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Test Method: CPSC-CH-E

CERTIFICATE OF ACCREDITATION

Key Considerations for Ensuring Quality Radioanalytical Laboratory Services for Superfund Sites Activities

METHOD 8330A NITROAROMATICS AND NITRAMINES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Update on ASTM and Standard Methods method development activities

Drillox Technology. Technology Covered by Patent Application

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Shaker Table Extraction

Shake-and-Shoot : A Rapid Solvent Extraction Process for PCBs and TPH 11375

This document is a preview generated by EVS

An Update on SW-846. Office of Resource Conservation and Recovery (ORCR)

SADA General Information

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

FINAL. Contract No. W52P1J-06-D-0019 Delivery Order 0004

Desk study 33-1 Sample pre-treatment for soil, sludge and biowaste. ANNEX 1 Tables

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

Leaching Environmental Assessment Framework Pre-Method 1313: Liquid-Solid Partitioning as a Function of Eluate ph using a Parallel Batch Procedure

Gy sampling theory in environmental studies 2. Subsampling error estimates

ISO INTERNATIONAL STANDARD. Soil quality Pretreatment of samples for determination of organic contaminants

APPENDIX II QUALITY CONTROL SUMMARY TABLES

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

Basic Digestion Principles

U.S. EPA Superfund Counts Per Minute (CPM) Electronic Calculator Stuart A. Walker. U.S. Environmental Protection Agency, Washington, DC.

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

METHOD 3520B CONTINUOUS LIQUID-LIQUID EXTRACTION

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

Advanced Design Application & Data Analysis for Field-Portable XRF

MANUAL FOR THE CERTIFICATION OF LABORATORIES ANALYZING ENVIRONMENTAL SAMPLES FOR THE IOWA DEPARTMENT OF NATURAL RESOURCES

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments

Part 14: Water quality Sampling. Guidance on quality assurance and quality control of environmental water sampling and handling

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

DRAIN TRACING DYE RED E123

CALIBRATION REPORT FOR THERMOHYDROMETER

Understanding the Uncertainty Associated with Analytical Results: Sources, Control and Interpretation of Results. Marc Paquet, Chemist M.Sc.

PROJECT ID: W09341 LABORATORY REPORT NUMBER: L

LOUISVILLE CHEMISTRY GUIDELINE (LCG)

DOE S RADIOLOGICAL TRACEABILITY PROGRAM FOR RADIOANALYTICAL MEASUREMENTS: WORK IN PROGRESS

COLUMBIA UNIVERSITY PERMIT APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIALS

POLICY ISSUE (INFORMATION)

Clay Robinson, PhD, CPSS, PG copyright 2009

WM2011 Conference, February 27 - March 3, 2011, Phoenix, AZ

Quality by Design and Analytical Methods

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

4. STATISTICAL SAMPLING DESIGNS FOR ISM

Standard Practice for Heat Aging of Plastics Without Load 1

ANALYTICAL REPORT. Attn: Richard Boelter

NANOTECHNOLOGY: AN INDUSTRIAL HYGIENE PERSPECTIVE. Loren Anderson, CIH, ROH

IRTC Incremental Sampling Methodology February 2012

Pitfalls of Using Non-Standard Standards. Mark Bruce Ph. D.

U.S. EPA Method 8270 for multicomponent analyte determination

IMPROVE DETECTION AND QUANTITATION. Richard Burrows

STANDARD OPERATING PROCEDURE NO. 40 GRAVIMETRIC MOISTURE CONTENT

-However, this definition can be expanded to include: biology (biometrics), environmental science (environmetrics), economics (econometrics).

Introduction to IH Analytical Chemistry

The Application of Method TO-15 to Naphthalene Measurements in Indoor Air

ACCURACY is the nearness of a result or the mean of a set of results to the true or accepted value.

Transcription:

Better Site Characterization Through Incremental Sampling Methodology Status Report on ITRC Guidance Mark Bruce Ph. D. 2011, TestAmerica Laboratories, Inc. All rights reserved. TestAmerica & Design are trademarks of TestAmerica Laboratories, Inc. August 15, 2011

Chasing Uncertainty Sources Instrumental analysis Sample preparation Laboratory sub-sampling Field sample collection 2

Does the decision unit fit in the sample jar? Representative subsampling 3

Why is this important? _ X with known and less uncertainty Representative subsampling 4

Better Data Drives Better Decisions 5

Incremental Sampling Systematic Random Design Random starting locations in first grid 6

ITRC Developing Guidance Incremental Sampling Methodology Team ~ www.itrcweb.org/teampublic_mis.asp ~ Formed Jan. 2009 Disclaimer: Most of the material in this presentation has been derived from the Spring 2011 draft guidance developed by the ITRC ISM team. ITRC does not endorse the use of specific vendors or technologies. This presentation is not official ITRC sanctioned training material. It has been reviewed by ITRC for compliance with the ITRC usage policy. 7

ISM Guidance 8 Introduction ISM Principles Systematic Planning Statistical ISM Design Field Implementation Laboratory Process Making Decisions Regulatory Concerns Case Studies Stakeholder Input

Laboratory Processing & Analysis Introduction Laboratory Processing Laboratory Analysis Quality Assurance 9

10 No Universal Lab Sample Processing

11 Real Life ISM is Complicated

Include Lab Processing in Project Planning Lab 12

Sample Processing Goals Goal: Improve subsampling representativeness Goal: Improve precision & minimize bias 13

Sample Processing Affects Data Always ~ Improved precision Hopefully ~ Improved accuracy (of single measurements) Retain contaminants of concern Avoid contamination Sweat the details or risk misleading data 14

Symbol key Good effect Bad effect Good or Bad effect depending the question Result or statistic gets larger in value Result or statistic gets smaller in value

Identify the Sample 16 Materials to remove ~ Vegetation ~ Oversized material ~ Decantable water Manual removal Sieve (after drying) ~ < 2 mm (#10) Lead source example ~ Paint fines ~ Intact slugs

Analyte Groups Volatile organics Energetics Metals, Hg PCBs Organochlorine Pesticides Phenoxy acid herbicides Petroleum hydrocarbons Semivolatile organics 17

Semivolatile Organic Compounds and Inorganics 18 Bulk Sample Splitting Sample Conditioning Particle Size Reduction Splitting and Subsampling Analyte Specific Considera tions

Bulk Sample Splitting Limited Applicability Sample Splitting for multiple analyte groups ~ Alternate or fractional shoveling ~ Consider nugget effect ~ Increases fundamental error (variance) 19

Semivolatile Organic Compounds and Inorganics 20 Bulk Sample Splitting Sample Conditioning Particle Size Reduction Splitting and Subsampling Analyte Specific Considera tions

Sample Conditioning Air drying ~ Room temperature - most common ~ Ventilation hood ~ Consider volatilization losses Boiling point 21 R&D Binding to soil particles (lower conc. > higher binding > lower losses) Loss risk table naphthalene 2-methylnaphthalene acenaphthene dibenzofuran Loss risk test ~ Goal: Crushable agglomerates

Sample Conditioning As-received ~ Least air exposure Fewest analyte losses ~ Limits soil processing options Fractional shoveling Manual forced sieving 22

Semivolatile Organic Compounds and Inorganics 23 Bulk Sample Splitting Sample Conditioning Particle Size Reduction Splitting and Subsampling Analyte Specific Considera tions

Defining Terms Grinding: ~ Generic term for soil disaggregation or milling. The grinding type or equipment must be specified to select a particular laboratory process. 24

Defining Terms Disaggregating: ~ Breaking the soil clumps into individual small particles, but keeping the small pebbles and hard crystalline particles intact. t RSD Metals Conc. Compared to milling 25

Defining Terms Milling: ~ Complete particle size reduction of all soil components including hard crystalline materials to a defined maximum particle size (e.g. < 250 um or < 75 um). RS SD Metals Conc. Picture from USACE-Alan Alan Hewitt Compared to disaggregating 26

To mill or not to mill Yes - recommended ~ Crystalline particles, fibrous threads ~ Energetics, metals ~ Strengths Reduces fundamental error Reduces sub-sampling error Facilitates mixing Improves precision Picture from USACE-Alan Hewitt 27

Milling Improves Precision 70 Lead Precision 60 % RSD 50 40 30 20 10 28 0 Unground 5-min Puck Mill 8-hr Ball Mill 12-hr Ball Mill 16-hr Ball Mill 20-hr Ball Mill

To mill or not to mill No not recommended ~ Volatile, thermally labile, increased availability ~ Examples Low boiling PCBs, OCPs, TPHs, SVOCs, metals ~ Limitations Analyte losses Metals contamination 29 Potential bias to metals risk assessment (pebbles)

Mill Erosion Elevates Cr Results 250 Chromium Results Con centratio on (mg/kg g) 200 150 100 50 30 0 Unground 5-min Puck Mill 8-hr Ball Mill 12-hr Ball Mill 16-hr Ball Mill 20-hr Ball Mill

Milling Releases Metals from Pebbles 25000 Lead Results Conc centration n (mg/kg g) 20000 15000 10000 5000 31 0 Unground 5-min Puck Mill 8-hr Ball Mill 12-hr Ball Mill 16-hr Ball Mill 20-hr Ball Mill

How best to mill Puck mill or ring and puck mill ~ stable energetics Ball mill Mortar and pestle Consider ~ Analytes ~ concentration of interest ~ grinder materials ~ Particle size needed Picture from USACE-Alan Hewitt 32

How fine is the grind? What is the target particle size? How to determine completeness ~ Timer ~ Visual inspection ~ Pinch of flour ~ Sieve #200 (~75 um) 33

Mills have Limitations 5 Minutes puck mill grindingg ~ 94% of Material < 100 mesh ~ 6% > 100 mesh 8.6 g of deformed metal fragments 47.6 g of other material 34

Semivolatile Organic Compounds and Inorganics 35 Bulk Sample Splitting Sample Conditioning Particle Size Reduction Splitting and Subsampling Analyte Specific Considera tions

Sample Condition Affects Subsampling Options Wet sticky sample ~ Alternate shoveling ~ Fractional shoveling ~ 2 Dimensional Japanese Slabcake Dry flowable powder sample ~ All splitting and subsampling techniques 36

Wet Splitting Options Alternate shoveling Fractional shoveling 37

Dry Splitting Options Riffle splitter Gerlach, J. Chemometrics 2002; 16: 321-328 38

Dry Splitting Options Rotary sectorial splitter Paper cone sectorial splitter 39 Gerlach, J. Chemometrics 2002; 16: 321-328

Dry Splitting Options 1-Dimensional Japanese Slab Cake 40

Sub-sampling Options 2-Dimensional Japanese Slabcake Dry 41 Wet

Sub-sampling Tools Square straight sided scoops for dry non-cohesive soil 42

Using large subsamples Larger particles ~ Produce larger errors or require larger subsamples %RSD 200 150 100 1 g 5 g 10 g 30 g Fundamental Error 50 0 0 1 2 3 4 5 43 Particle size (mm) ASTM D6323 Sec. A1.1

Dry, fine particulate samples ~ Health and Safety dust control Larger sub-samples ~ (driven by fundamental error concerns) ~ Metals 10 g vs 1 g ~ Hg5gvs06g g 0.6 g Water added samples ~ Additional drying agent and time Sample Preparation Modifications 44

Laboratory equipment blanks ~ Limited clean matrices Laboratory Quality Control Measures Laboratory control samples (LCS) and matrix spikes ~ Practicality of large scale spiking in kg samples High cost Limited availability ~ Introduced post ISM processing into subsample Subsampling replicates 45

Matrix Options for Laboratory Quality Control Measures Reagent Water Ottawa sand Teflon Boiling Chips Soda Lime Glass Reference Sample Split field sample 46

Laboratory Certification National Environmental Laboratory Accreditation Program Non-NELAP State Accreditation Agency-specific Accreditation ti ~ DoD Environmental Laboratory Approval Program

Reference Methods Incremental Sampling MIS-Based Laboratory Requirements for the Analysis of Explosives ~ (USEPA SW-846 Method 8330B) Metals in Solid Matrices ~ (USACE 2008) ~ Planned SW-846 Method 3050 Update V? 48

Reference Methods ASTM D6323 Standard Guide for Laboratory Subsampling of Media Related to Waste Management Activities ~ (ASTM 2003) Guidance for Obtaining Representative Laboratory Analytical Subsamples from Particulate Laboratory Samples ~ (Gerlach 2003) Laboratory Standard Operating Procedure 49

Lab Process Big Rocks Subsample with correct tools and process Match processes and analyte needs Disaggregate Mill or not Manage sample moisture 50

Guidance Document Projected Schedule Full ITRC (non-dod) review Early Q2, 2011 DoD & EPA review Late Q2, 2011 Final to ITRC communications Q4, 2011 Tech. Reg. Publically Available Q2, 2012 Internet based training Q2, 2012 51

Purpose of ISM Representative samples Better data Better decisions i 52

Acknowledgements Alan Hewitt, Tom Jenkins, Marianne Walsh, Hugh Rieck Ligia Mora-Applegate (FL DEP) Mark Malinowski (CA DTSC) Michael Stroh (MO DNR) Kelly Black (Neptune) 53

Contact Information Mark L. Bruce Ph.D. Technical Director 54 TestAmerica 4101 Shuffel St. NW North Canton, OH 44720 Tel: 330-966-7267 Email: mark.bruce@testamericainc.com t i www.testamericainc.com