Comparison of V and 10 V DC Voltage References

Similar documents
Bureau International des Poids et Mesures, Sèvres, France. *KEBS, Kenya Bureau of Standards P.O. Box , Nairobi, Kenya

by A.Tonina*, R.Iuzzolino*, M.Bierzychudek* and M.Real* S. Solve + R. Chayramy + and M. Stock +

by S. Solve +, R. Chayramy +, M. Stock +, D. Vlad*

Final Report August 2010

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES

* Directorate of Measures and Precious Metals Mike Alasa Beograd Serbia

APMP Key Comparison of DC Voltage at V and 10 V

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Euramet EM-S40. Bilateral Comparison KIM-LIPI / LNE. Final Report

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3.

BUREAU INTERNATIONAL DES POIDS ET MESURES. Comparison of Quantum Hall Effect resistance standards of the PTB and the BIPM

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard

Final Report. CCEM Comparison of 10 pf Capacitance Standards. Anne-Marie Jeffery Electricity Division NIST May 2000 Revised March 2002

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

APMP supplementary comparison of absorbed dose rate in tissue for beta radiation

Supplementary Comparison EURAMET.EM-S19 EURAMET Project No. 688

The BIPM key comparison database (KCDB): linkage of key comparison results

Ajchara Charoensook, Chaiwat Jassadajin. National Institute of Metrology Thailand. Henry Chen, Brian Ricketts and Leigh Johnson

ANNEXE 8. Technical protocols for the interlaboratory comparisons

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

New Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018

PREDICTION OF THE OUTPUT VOLTAGE OF DC VOLTAGE STANDARDS

Exercise 1: Thermistor Characteristics

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

Standards for Radiation Thermometry

The BIPM key comparison database, Aug /10

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

Comparison protocol EURAMET project

Final Report on COOMET Key Comparison of Capacitance at 10 pf (COOMET.EM-K4)

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Euramet project 1075 Bilateral comparison

Metrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017

I. Yang, C. H. Song, Y.-G. Kim & K. S. Gam

Test Report EN (2008)

NORTH AMERICAN INTERLABORATORY COMPARISON OF 10 V JOSEPHSON VOLTAGE STANDARDS

Infrared Thermometer Calibration A Complete Guide

CERTIFICATE OF CALIBRATION

OIML R 50-3 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

EDITION 1 OCTOBER 1997 EA-10/09 PAGE 1 OF

Interamerican Metrology System (SIM) Regional Metrology Organization (RMO) Capacitance Comparison, Final Report

CERTIFICATE OF CALIBRATION

5730A High Performance Multifunction Calibrator. Extended specifications

OIML R 51-2 RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Automatic catchweighing instruments

Referensdosimetri. Crister Ceberg Medical Radiation Physics Lund University Sweden

INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR

INTERLABORATORY MASS COMPARISON BETWEEN LABORATORIES BELONGING TO SIM SUB-REGIONS COORDINATED BY CENAM (SIM.7.31a & SIM.7.31b)

Electricity and Magnetism Supplementary Guide to the JCRB Instructions for Appendix C of MRA

Decade Capacitance System

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the BEV, Austria and the BIPM in medium-energy x-rays

Supplementary Comparison EUROMET.EM-S23 EURAMET PROJECT No 815 FINAL REPORT

Exercise 2: The DC Ohmmeter

Euramet project 1187 Comparison of Instrument Current Transformers up to 10 ka. Technical protocol (March 2012)

DIGITAL THERMOMETER OPERATOR S MANUAL

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Mise en pratique for the definition of the ampere and other electric units in the SI

Low Frequency Electrical Metrology Programs at NIST

UNCERTAINTY ANALYSIS FOR LABORATORY ACCREDITATION. Peter B. Crisp. Fluke Precision Measurement Ltd, 52 Hurricane Way, Norwich, UK

Inter-laboratory Comparison of Impedance-Type Hygrometer in the Range from 10 % to 95 % at 5 C to 55 C

INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN

Establishment of a Traceability Chain in Metrology for Materials

Mass determination of 1 kg silicon spheres for Avogadro project

BIPM Key Comparison BIPM.RI(I)-K6 PROTOCOL 3.0 CCRI(I) 6 November 2017

A bilateral comparison of a 1 kg platinum standard

Glossary Innovative Measurement Solutions

Final Report CCEM.RF-K8.CL COMPARISON CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

European Association of National Metrology Institutes

Electricity and Magnetism Supplementary Guide for the Submission of CMCs

Fig. 1-1 Current Flow in a Resistive load

Uncertainties in Acoustics

R SANAS Page 1 of 7

Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays

Bureau International des Poids et Mesures

Primary Frequency Standards in TAI. Gérard Petit Bureau International des Poids et Mesures Sèvres Cedex, France

WATT BALANCES AND THE FUTURE OF THE KILOGRAM

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

Final Report on COOMET Supplementary Comparison of Capacitance at 100 pf (COOMET.EM-S4)

CCM short note on the dissemination process after the proposed redefinition of the kilogram

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

1 Phone , fax , 2 Phone , fax ,

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

INTERNATIONAL OIML R 61-2 RECOMMENDATION

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Lamp and Control Panel (Lamp Panel)

International Pyrheliometer Comparison IPC-XII

The General Conference on Weights and Measures (CGPM), at its 24th meeting,

INNOVATION IN MAGNETICS DS0003/18. Mag-01H. Single Axis Fluxgate Magnetometer.

EUROMET Comparison of a 10 mh Inductance Standard at 1 khz EUROMET.EM-K3. Final Report

Il nuovo Sistema Internazionale (SI) Le unità elettromagnetiche

Reference Materials for Trade and Development: Quality and Comparability

Nanometrology and its role in the development of nanotechnology

OIML R RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Instruments for measuring the areas of leathers

Transcription:

Comparison of 1.018 V and 10 V DC Voltage References Technical protocol for BIPM.EM-K11.a and.b comparisons 1. Introduction The Mutual Recognition Arrangement among National Metrology Institutes (NMIs) places particular importance on key comparisons to demonstrate a NMI s ability to measure certain critical quantities. The Consultative Committee for Electricity and Magnetism has identified comparisons of 1.018 V and 10 V standards, including Josephson array voltage standards (JAVS), as key comparisons. These standards are considered as primary voltage standards. To take advantage of the high accuracy of JAVS, on-site direct comparisons have been carried out by the BIPM since 1991 (BIPM.EM-K10.a/b). Another way that NMIs check the coherence of JAVS standards is to use Zener diode-based references (Zeners) as travelling standards in international comparisons. Such comparisons are most demanding of the performance of Zeners. Nevertheless, provided that corrections are made for the effects of pressure and temperature on the Zener outputs, it is possible to reach the one part in 10 8 level of uncertainty. The NMIs that do not posses JAVS often rely on Zeners as travelling standards to assure traceability to Josephson standards via calibrations and comparisons with other NMIs or with the BIPM. Over the years, some NMIs have participated in regular calibrations of their national voltage standard by the BIPM. Consequently, they have established accurate values and drift rates of their standards. 2. Purpose The purpose of this comparison is to link the voltage reference of the laboratory (acronym), country, to that of the BIPM in the frame of the BIPM.EM-K11.a and.b key comparisons. Technical changes to this protocol need to be approved by the CCEM WGLF (low frequency working group. 3. The standards The travelling standards are number Fluke 732B Zeners referred as: Za s/n serial number 1 Zb s/n serial number 2 Page 1 of 6

Those Zeners have two output voltages, nominally 1.018 V and 10 V. Within this comparison, both outputs will be measured. 4. Powering the Zeners During the transport the Zeners are powered in parallel by their internal battery and an extra external battery. These external batteries must be disconnected as soon as the Zeners are in the laboratory and be fully charged before the return travel. They must not be connected to the Zeners when powered by the mains nor charged by the internal charger of the Zeners. The Zeners shall be disconnected from the mains at least two hours before the beginning of the measurements and be reconnected to the mains at most six hours later. If the front panel LOW BAT indicator starts blinking the Zeners must be immediately connected to the mains for recharging of the battery. When the Zeners are not in the process of measurements, they must be permanently connected to the mains (front panel AC PWR lighted). 5. Measurements schedule At the BIPM, there will be at least five series of measurements over a two week period before AND after the measurements at laboratory. At the laboratory, one series of, at least, five consecutive measurements will be performed. The measurements at the BIPM will be made in period 1 and then in period 3. The measurements at the laboratory will be made in period 2. If necessary (and justified) the first measurements after the transportation will be considered as preliminary (not taken into account for the final calculation). The Zeners will be sent to and from country on the first working day of the week following the measurements. In organizing the transportation it needs to be ensured that the total transport time is shorter than the battery hold time. Page 2 of 6

6. Temperature and pressure coefficients, environment conditions The resistance of the oven temperature thermistor, which is an indicator for the temperature of the Zener reference, can be measured via the connector at the rear panel of the standard. A special cable is supplied with the standards to measure the two-terminal thermistor resistance. To avoid self-heating of the thermistor, the test current should not exceed 10 µa. The atmospheric pressure and the internal thermistor resistance will be measured and reported for each measurement of an output voltage. The measurement results of the laboratory shall be given without applying any correction for temperature or atmospheric pressure. These corrections for temperature or atmospheric pressure will be applied by the BIPM using the following formula and the coefficients in the table: U 0 = U m (1 C T (T m T 0 ) C P (P m P 0 )) where U 0 is the corrected value, U m the measured value, C T and C P the temperature and pressure coefficients, T m and P m the values of the thermistor resistance and atmospheric pressure at the time of the measurement, T 0 the thermistor reference value and P 0 the reference atmospheric pressure 1013.25 hpa. The measurement results shall be provided in the following format: Standard Output Measured Voltage / µv Zener Temperature /kω Atmospheric Pressure /hpa Lab. Temperature / C Lab. Relative Humidity Level /% 1.018 V value value value value value Za 10 V value value value value value Zb 1.018 V value value value value value 10 V value value value value value The ambient temperature and relative humidity shall be measured and indicated in the results form. No correction will be applied. Page 3 of 6

7. Connections The binding posts GUARD and CHASSIS will be connected together and connected to the ground in a single point. During the measurements the mains plug at the rear of the Zeners will be disconnected. 8. BIPM Uncertainty budget In addition to the uncertainty on the realisation of the volt through the operation of the BIPM primary voltage standard based on the Josephson Effect, BIPM provides the following uncertainty components on the measurement of the transfer standards: 1- Type A uncertainty calculated as the standard deviation of the mean of the measurements performed at BIPM. This uncertainty can t be lower then the Zener intrinsic noise level which is considered, at BIPM, at the level of 1 part in 10 8. 2- The uncertainty on the pressure an temperature corrections evaluated from the uncertainty on the correction coefficients applied to the voltage measurements and the difference of the mean atmospheric pressure and mean internal Zener temperature difference measured at BIPM and at the participation laboratory. 3- Uncertainty on the transfer of the standards calculated in two different ways: the internal consistency (a priori uncertainty) and external consistency (a posteriori uncertainty). The larger of these two components is considered as a measure of the transfer uncertainty. 9. Participant report The laboratory report must be sent to the BIPM within one month from the completion of his measurements. This report shall contain: The measurement method description and: for each reported value: identification of Zener date and time of measurement measured voltage thermistor resistance Page 4 of 6

ambient temperature, humidity, and pressure the Type A standard uncertainty; an uncertainty budget with the different sources of uncertainty and their values, as: realisation or maintenance of the voltage reference detector (gain, bias current, offset, input impedance, nonlinearity, etc.) leakage resistance thermal electromotive forces electromagnetic interference thermistor and pressure measurements; 10. Final report The draft version of the final report will be issued within two months after completion of the comparison. It will be sent to the laboratory for discussion and approval. The final report will be then submitted to the chairman of CCEM WGLF for approval and will be published in the KCDB. 11. Share of costs The BIPM covers the transport of the equipment to the NMI. The NMI is engaged to arrange and pay the transport of the equipment back to the BIPM. 12. Contact persons Pilot Laboratory Participant Dr Bureau international des poids et mesures (BIPM) F 92312 Sèvres Cedex France Tel.: + 33 1 45 07 70 60 Fax : +33 1 45 07 62 62 E-mail: stephane.solve@bipm.org contact details Page 5 of 6

13. Revision History Version number Date of Issue/Review Ver 1.0 Final version 1.0 Summary of change Ver. 2.0 5/4/2012 Attribution of QMS identifier:, V2.0 New section 11: charging policy Ver. 2.1 9/8/2014 text of different sections clarified Page 6 of 6