Varian SpectrAA 220/880 Zeeman

Similar documents
Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Atomic Absorption Spectrometer ZEEnit P series

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

novaa 800 D Atomic Absorption Spectrometer

Introduction to Fourier Transform Infrared Spectroscopy

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

110 Lowell Rd Hudson, NH USA Tel:

Product Descriptions and Offerings

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

Introduction to Fourier Transform Infrared Spectroscopy

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

IN QUALITATIVE ANALYSIS,

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

University Wet Chemistry Analyzer Packages

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Defining quality standards for the analysis of solid samples

Analytical Instrumentation

Perseverance. Experimentation. Knowledge.

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

DI 3500 Discrete Aoalvzer

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

SIFT-MS. technology overview

Traceable UV-Vis Reference Materials

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Compact Orifice FlowMeter

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

ICP-OES Application Note Number 35

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Prof. Dr. Biljana Škrbić, Jelena Živančev

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer

Atomic Absorption & Atomic Fluorescence Spectrometry

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

The Plus for your lab!

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

SIMATIC Ident Industrial Identification Systems

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

AutoChem II 2920 A Catalyst Characterization Laboratory

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

ICP-MS. High Resolution ICP-MS.

Toxinometer Measurement System FUJIFILM Wako Chemicals U.S.A. Corp.

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

ZEEnit. Quality is the difference

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Fusion UV/Persulfate TOC Analyzer

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

XBC300 Gen2. Fully-automated debonder and Cleaner

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

XR Analog Clock - Manual Setting Model Troubleshooting Guide

cobas 6000 analyzer series Flexibility you can build on

BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY

Analysis of domestic sludge using the Agilent 4200 MP-AES

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

CONTINUOUS FLOW CHEMISTRY (PROCESSING) FOR INTERMEDIATES AND APIs

Guide to Peptide Quantitation. Agilent clinical research

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

high performance OPTIC 3 and applications a total analytical solution

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Multi-element process analyzer

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

On the use of Deming and quadratic calibrations in analytical chemistry

Humidity Calibration Solutions

Elemental analysis of river sediment using the Agilent 4200 MP-AES

SPECTROPHOTOMETERS. Visible and UV-Visible

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

MetWorks Metabolite Identification Software

Varian Galaxie Chromatography Data System for Preparative HPLC

Humidity Calibration Solutions

The solution for all of your

2101 Atomic Spectroscopy

Your partner in Science!

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Atomic Spectroscopy AA/ICP/ICPMS:

Atomic Absorption Spectroscopy

for XPS surface analysis

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Chemistry Instrumental Analysis Lecture 18. Chem 4631

L-malic acid measurement in wines using the SpectraMax Plus 384 Microplate Reader

Pulsar. Delivering NMR to your benchtop

Transcription:

AA Varian SpectrAA 220/880 Zeeman

The world s best family of Zeeman AAS Varian, Inc. is a world leader in instrumentation for atomic spectroscopy. From our development of the first components for atomic absorption spectrometers in the 1950s to the recent ground breaking Vista series of simultaneous ICP emission spectrometers, Varian, Inc. has over 40 years experience of innovation and development in all areas of atomic spectroscopy. 2

Varian researchers developed the Zeeman technique in the late 1960s and patented all possible configurations in 1971. Since then, three generations of Varian instrumentation have consolidated SpectrAA Zeeman s reputation for excellence, sensitivity and maximum performance with challenging samples. The new generation of SpectrAA Zeeman instruments continues this proud tradition by offering the highest sensitivity, performance, simplicity of operation and industry leading software expected of a worldwide leader in atomic spectroscopy. The combination of a Constant Temperature Zone graphite furnace, AC modulated Transverse Zeeman background correction and polynomial interpolation ensures superior spectral interference correction and maximum sample accuracy. In addition, Varian s low thermal mass graphite tubes with their long atom cell and fixed 0.8 Tesla AC magnetic field maximizes sensitivity without requiring complex optimization of the field strength. Productivity in the laboratory is also improved with the use of Varian s award winning multi-tasking Worksheet software. This advanced software combines the familiar spreadsheet concept with the full multi-tasking capabilities of the Windows operating system. When combined with flexible accessory options, the SpectrAA Zeeman series sets the industry benchmarks for performance without compromise. The SpectrAA Zeeman Family: The economical SpectrAA-220 Zeeman and the high performance research grade SpectrAA-880 Zeeman. 3

Optical excellence Microdrive monochromator Polarizer Coma Elimination Pairs The optical layout of the SpectrAA-880 Zeeman is shown. This features an automated 8 lamp turret providing ample lamp capacity and simple operation. 4 The first requirement of the Zeeman optics is for a narrow, laser like optical image, which is provided by the high-energy hollow cathode lamps. This intense beam is matched to the narrow furnace tube profile and high efficiency surface protected mirrors which transmit the beam. This ensures maximum light throughput, producing excellent signal-to-noise ratios. The use of Coma Elimination Pairs (comprising a matched set of a flat mirror and a focusing mirror) to turn the light beam eliminates coma (divergence of the light beam). This provides maximum light transmission for the best signal-to-noise performance at all wavelengths. The selected Polarizer used in Varian Zeeman instruments is designed for minimum energy loss, unlike prism-based systems. The microdrive monochromator provides up to six times better wavelength definition for optimum line selection with unsurpassed repeatability of +/- 0.02 nm. The outcome is smooth, quiet operation with the highest wavelength accuracy. The result is the utmost accuracy with all your results and superb detection limits at all analytical wavelengths. Having designed superior optics, we ensure superior lifetime performance by coating the optical components with quartz, and completely sealing the optical system against dust and vapor.

Achieving accurate Zeeman background correction The Zeeman Effect The Zeeman effect is the splitting and polarization of atomic spectral lines in the presence of a magnetic field. Molecular species and particulates that can cause background absorption remain relatively unaffected by the magnetic field. The Zeeman technique uses a magnetic field to achieve accurate background correction. With the magnet off, the total absorbance is measured. With the magnetic field applied, splitting of the spectral profile occurs, and only the background is measured. The atomic absorbance signal is determined by subtracting the background absorbance (magnet on) from the total absorbance (magnet off). The Varian solution Zeeman background correction is a powerful tool, but requires correct design to deliver accurate answers. The SpectrAA Zeeman features the sensitive transverse AC modulated Zeeman configuration, which has the field applied across the atomizer. This avoids the sensitivity losses observed with a DC (permanent) magnet and maximizes light throughput compared with longitudinal designs where end caps restrict the light passing through the pole pieces of the magnet. Varian s patented magneticfield waveform provides a delay time of less than 5 ms between measurements and collects 100/120 data points (50/60 Hz) every second. Polynomial interpolation For accurate correction the instrument must determine the true background at the time the total signal was measured. Some instruments use simple linear interpolation of the background, which can result in erroneous calculations of the background signal if this signal is changing rapidly (a common occurrence with furnace analyses). SpectrAA Zeeman uses threepoint polynomial interpolation to accurately track the actual shape of the peak and correctly calculate the background signal at the time the total signal was measured. Background to be calculated at this magnet off measurement Background to be calculated at this magnet off measurement λ Magnet Off λ Magnet On Calculated signal inferior Background Molecular Absorption Total Absorbance Measured HC Lamp Emission Profile Background Molecular Absorption π component (parallel polarized) rejected by polarizer HC Lamp Emission Profile Total absorbance signal Magnet on (Background abs) Magnet off (Total abs) Linear Interpolation Procedure Polynomial Interpolation Procedure Total absorbance signal Magnet On (Background abs) Magnet Off (Total abs) The principle of the Transverse (AC) Zeeman technique Magnet Off The total absorbance is measured. Magnet On Zeeman splitting of the atomic absorption profile occurs and the polarizer excludes the central π component. This allows only background absorbance to be measured at the exact analytical wavelength. Linear interpolation between consecutive background data points incorrectly calculates the background. Erroneous results with complex matrices are often observed. The SpectrAA Zeeman three-point polynomial interpolation accurately tracks the background signal, resulting in 11 times improvement in correction accuracy. 5

Superior Zeeman performance Constant Temperature Zone design Varian s furnace research has demonstrated that the best graphite furnace performance is achieved using a Constant Temperature Zone (CTZ) graphite furnace. The CTZ is created by carefully matching the design of the GTA-110 power supply to low thermal mass, end-heated graphite tubes. This ensures extremely fast atomization for the best signal-to-noise characteristics with difficult sample matrices. The GTA-110 also features the most advanced furnace sampling systems. Analytical cycle times are reduced and performance is improved using hot injection and synchronized sampling. Varian s longitudinally heated GTA-110 CTZ graphite furnace with transverse Zeeman background correction provides outstanding performance at ppb levels with the flexibility to handle difficult samples speedily and effectively. This comes from the proven efficient furnace design, the patented dynamic feedback temperature control and flexibility in gas and temperature programming. Performance Table Element Wavelength Detection Limit Characteristic Mass (nm) (µg/l) (pg) (pg) Arsenic 193.7 0.0474 2.37 7.50 Cadmium 228.2 0.0010 0.05 0.29 Chromium 357.9 0.0103 0.52 1.72 Copper 324.8 0.0410 2.03 10.29 Manganese 279.5 0.0048 0.24 0.48 Molybdenum 313.2 0.0840 4.18 6.30 Lead 283.3 0.0150 0.74 5.17 Selenium 196.0 0.0230 1.59 8.50 Thallium 276.8 0.0640 3.20 5.05 Vanadium 318.4 0.1200 6.01 35.15 0.81 0.60 0.40 0.20 0.00 0.64 0.60 0.40 0.20 Cr Pb By combining research grade optics with improved graphite tube design and new state of the art peak algorithms, the SpectrAA Zeeman provides unparalleled detection limits even in complex sample matrices (top graph). 0.00 The Universal tube 1 with an integrated platform allows determination of difficult elements such as Cr and Cd. 0.66 0.60 0.40 0.20 0.00 As Signal graphics for lead and arsenic analysis of an environmental river water sample gave a result of 16.2 µg/l for lead and 30 µg/l for arsenic using an injection volume of 50 µl (middle and bottom graphs). 6

UltrAA lamps lower detection limits Whether you are using flame, furnace or vapor AA, Varian s range of UltrAA lamps increase sensitivity and reduce detection limits, allowing determinations of trace metals at even lower levels. The UltrAA lamp series of high intensity, boosted discharge, hollow cathode lamps can be used with all SpectrAA series instruments, for the most demanding applications. Lamp operation UltrAA lamps use the standard lamp current, but apply a second discharge within the lamp. This boost current is supplied from an external control module. The resulting sharper emission profile reduces self-absorption and line broadening, increasing sensitivity of AA determinations by up to 40%. Emission intensity is also increased by three to five times, reducing baseline noise levels. The lower baseline noise levels and the higher sensitivity ensure lower detection limits can be achieved. Benefits of the UltrAA lamp Increased sensitivity comparative signals for a 75 µg/l Se standard are shown. Reduced baseline noise. Lower detection limits, resulting from the enhanced signal-to-noise. Enhanced calibration linearity. Longer lamp lifetimes typical lamp lifetimes exceed 8000 ma hours of operation. Simple installation lamps are mounted directly into the socket (without any flying leads), just like conventional lamps. A fixed boost current eliminates difficult manual adjustments. Automatic lamp recognition enables the software to identify the lamp and select the recommended operating conditions. Enables simultaneous operation of two UltrAA lamps one lamp to be in use while the other is being pre-warmed. Standard 3 0.50 0.50 UltrAA lamp Absorbance Background 0.00 0.00 Conventional HCL 2500 0 Temperature 72.0 74.5 Time (sec) 7

Innovative worksheet software Press the Select button to select samples for analysis or tag selected results for export to LIMS or another software package. Autocopy and unique pattern recognition capabilities simplify manual label entry. Alternatively, you can import directly from LIMS or use bar code readers to scan sample labels directly into the software. View concentration results, precision and absorbance results as the analysis progresses. Color coding and flags (displayed after the sample result) highlight out-of-range results, uncalibrated results or other errors. Using OLE-2, results can be exported online during analysis to other commercial software programs (e.g., Microsoft Excel), for custom data manipulation. The message line informs you of the system status and provides operational hints. Status display provides an instant summary of instrument conditions for the selected element and keeps you informed of progress during analysis. 8

The SpectrAA Zeeman software is modeled on Varian s acclaimed worksheet software. Using the multi-tasking capabilities of Windows, you can start today s analysis while simultaneously preparing a report on yesterday s results. Imagine the productivity improvements you will achieve. The spreadsheet concept at the heart of the SpectrAA software and the simplified interface also means minimal training is required. The Worksheet AA Final concentration results are displayed (after weight/volume correction if required) in a spreadsheet concept common to many business applications. Results for flame, vapor and furnace determinations are displayed simultaneously so that you can view results for the entire batch of samples. Quality Control Extensive rate and label driven Quality Control Protocols are provided to validate data as it is collected. The optional Quality Control Protocols software provides even greater capability for full compliance with all international regulatory requirements. This includes the capability to create custom QC tests. Which operating system? Choose from Windows 95/98, Windows NT or Windows 2000 operating systems. Click on an individual result to display the signal graphics where stored. You can customize the display to view only the information you need. For example, select from the worksheet, signal graphics, calibration graph with full calibration data or the data log with complete analytical results. The data log is date and time stamped and includes all measurement parameters, raw data, final results and error messages. Comprehensive multimedia Help includes step-by-step audio and video instructions on hardware setup and routine maintenance. 9

High productivity vapor generation Couple the VGA-77 and ETC-60 for hydride generation capability with the Zeeman series. This offers an easy and reliable way of validating GFAA results and analyzing difficult matrices. 10 Varian s fully automated modular VGA-77 Vapor Generation Accessory is ideal for rapid trace level analyses of mercury (using the proven cold vapor technique) and other hydride forming elements at part per billion (µg/l) concentrations. The hydride vapor generated by the VGA-77 is electrically heated and atomized using the ETC-60 Electrothermal Temperature Controller. Using hydride generation techniques with SpectrAA Zeeman, you can verify your graphite furnace results, or eliminate complex and time consuming furnace programs. Unattended operation With the addition of the SPS-5 flame and vapor autosampler, unattended multielement determinations are also possible. The versatile SPS-5 provides capacity for up to 400 samples, loaded in convenient polypropylene racks, and has a separate rack dedicated to standards. For greater flexibility, you can program the SPS-5 to accept any rack type using the Custom Rack definition feature. Advantages of Continuous Flow Vapor Generation The continuous flow VGA-77 offers these advantages over competitive techniques, such as Flow Injection: Maximum sensitivity. Enhanced precision of 1-2 % RSD is achieved using integration of the steady state signal. Flow Injection produces transient signals, requiring multiple injections for accurate, reproducible results. Greater productivity results are obtained in less than a minute. High sample throughput of up to 70 samples per hour with 3 replicates per sample. Low sample consumption less than 8 ml per element during analysis. Modular construction to simplify change-over between elements with conflicting chemistries. Eliminate cross contamination by changing modules. Simple and automatic operation each sample is automatically combined with a continuous flow of acid and reagents.

From ownership to partnership Reducing the cost of ownership The SpectrAA series was designed with cost of ownership in mind. The easy-to-use software will minimize training and get your lab up and running faster. For protection in dusty or corrosive environments, the optics are completely sealed and all mirrors are quartz overcoated for long term, stable performance. When connected to a supply of clean, dry air, the internal air purge ensures total protection from attack in corrosive, humid or dust-filled environments. Comprehensive diagnostics assist rapid trouble shooting and fault diagnosis, maximizing instrument uptime. Varian s Telediagnostics option connects you to our worldwide network of support personnel for online assistance. This remote diagnosis service minimizes on-site calls and reduces down-time. Telediagnostics also gives you the freedom to access your data at any time. You can view the progress of your analysis from your home, exchange methods or results with other users or connect to other laboratories in your company. GLP Compliance and Validation The SpectrAA software complies with many international standards for Good Laboratory Practice (GLP). If you need to validate your SpectrAA system, Validation documentation is available for SpectrAA instruments, software and accessories. Varian, Inc. service organizations around the world support validation of our instruments in a number of ways, including training programs, support agreements, hotlines, Telediagnostics, service contracts and certification. An overview of the Validation documentation and services Varian, Inc. provides is available from your local Varian, Inc. office. Safety It is Varian s policy to manufacture safe products and to meet all legal requirements governing the design, manufacture and sale of safe products. As with all similar products, the following hazards may be present: high temperatures, high pressure gases, explosive gases, UV and visible light and electricity. Each product is designed to protect operators from potential hazards. Varian, Inc. supplies instructions that describe the correct procedures for the operation and maintenance of each product. For clarity, some images in this brochure may depict the spectrometer being used without safety covers. Ensure all safety covers, chimney etc. are in place for normal operation. SpectrAA atomic absorption spectrometers are designed to determine the concentrations of trace and major elements in solution. World Wide Web Varian s home page http://www.varianinc.com is another part of our on-going commitment to customer support. You can access application notes, newsletters and updates about the latest product developments or you can email us if you have a question. Use our online Parts and Supplies catalog to identify any consumables you need. Immediate access to information, applications support and technical service is never more than a mouse click, or a phone call away. The SpectrAA Zeeman series instruments are certified to comply with the requirements of the EMC and LV directives of the European Union. The SpectrAA Zeeman series also complies with the guidelines established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) for exposure to time varying magnetic fields. 11

Varian Analytical Instruments serving worldwide markets in: Agriculture Basic Chemical Biotechnology Clinical Electronics Environmental Photonics Toxicology Pharmaceutical Food and Beverage Metals and Mining Petroleum and Petrochemical Varian is committed to a process of continuous improvement which demands that we understand and then meet or exceed the needs and expectations of our customers both inside and outside the company in everything we do. Varian Sales and Dealer Offices Varian Analytical Instruments www.varianinc.com North America 800.926.3000, 1.925.939.2400 Europe The Netherlands 31.11.867.1000 Asia Pacific Australia 613.9560.7133 Latin America Brazil 55.11.3845.0444 China 86.21.6375.6969 Japan 81.3.5232.1239 Korea 82.2.3452.2452 Taiwan 886.22.698.9555 India 91.22.857.0181 Other sales offices and dealers throughout the world GC GC/MS HPLC AAS ICP-OES ICP-MS UV-Vis-NIR Fluorescence NMR Analytical Supplies Specifications subject to change without notice. Varian Australia Pty Ltd Part number 8510161900 Printed in Australia 2/2001 Windows is a registered trademark of Microsoft Corporation 1. Under exclusive worldwide licence from SGL Carbon and Analytik Jena. Printed on environmentally friendly paper. Design: Cruise Design Partnership. Photography: Earl Carter