Additional Analytical Methods. Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained

Similar documents
Supplementary material

Zircons were separated using standard techniques of mineral separation, including a Wilfley

DETRITAL ZIRCON GEOCHRONOLOGY BY LASER-ABLATION MULTICOLLECTOR ICPMS AT THE ARIZONA LASERCHRON CENTER

Appendix 1. Supplementary data presented here include isotopic and concentration data for

TABLE DR1. Summary of SHRIMP U-Pb zircon results for migmatitic rocks at Stowe Mountain. Total Radiogenic ratios Ages (in Ma) 204 Pb f U/ ±

Nu Plasma II - Collector Configuration

TABLE DR1. SUMMARY OF SHRIMP U-Pb ZIRCON RESULTS FOR SAMPLES D2-83 AND D2-24.

DR law. Interference of 176 Lu and 176 Yb onto 176 Hf was corrected by measuring 176 Lu and

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

from the Sierra Nevada Fault Project

Contributions to Mineralogy and Petrology. Department of Geology, University of California Davis, Davis, CA, USA

To avoid potential biasing, zircon fractions were not magnetically separated following

Data Repository DR Supplemental Data File. Feinberg et al., Figure DR2. Isothermal remanent magnetization data for typical lapillus

Sample and analytical information:

Supporting Online Material for

Cloudland gneisses, Mars Hill terrane, NC-TN: New SHRIMP U-Pb ages for detrital zircon and. monazite

Header. Volcanic matrix from three basalts and one dacite sample from the Black Mountains and Black Hills, respectively, were separated to perform

Supplementary Information. Table S1. Samples. 2. U-Pb and TE LASS-ICPMS analysis

LAACHER SEE REVISITED: HIGH SPATIAL RESOLUTION ZIRCON DATING IMPLIES RAPID FORMATION OF A ZONED MAGMA CHAMBER -

Towards SHRIMP SI: Developments in Stable Isotope Analysis with SHRIMP

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

dating of geological samples by laser ablation ICPMS

G 3. AN ELECTRONIC JOURNAL OF THE EARTH SCIENCES Published by AGU and the Geochemical Society

All work was carried out at the Advanced Analytical Centre, at James Cook

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Low level Os isotopic measurements using multiple ion counting

published sources and U-Pb geochronology performed in this study. We analyzed six

ICPMS Doherty Lecture 1

SUPPLEMENTARY INFORMATION

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Antonio Simonetti University of Notre Dame

), and age probability distribution (Deino and Potts, 1990). Open symbols denote analyses not used in weighted mean age calculations.

Table of Isotopic Masses and Natural Abudances

Accurate Hf isotope determinations of complex zircons using the laser ablation split stream method

GSA DATA REPOSITORY Topuz et al. ANALYTICAL PROCEDURE

Laser ablation split stream (LASS) between three ICP-MS for zircon petrochronology

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it?

Sample preparation for LAM work:

ICP-MS. High Resolution ICP-MS.

Observations Regarding Automated SEM and SIMS Analysis of Minerals. Kristofor Ingeneri. April 22, 2009

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

GSA Data Repository How old is Kīlauea Volcano (Hawai i)? Insights from 40 Ar/ 39 Ar dating of the 1.7-km-deep SOH-1 core M.O. Garcia et al.

APPENDICES. Appendix 1

Rock Sample Description and Petrography

Trace Elements - Definitions

Very long-term stability of passive margin escarpment

40 Ar (10-14 mol) 40 Ar* %

Laser Spectroscopy on Bunched Radioactive Ion Beams

SUPPLEMENTARY FILE. Whole-Rock Geochemistry

Autenticity control, provenance testing and fraud detection using mass spectrometry

40 Ar/ 39 Ar dating and errors

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Geological record of flat-slab induced extension in the Southern Peruvian forearc

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

McClelland & Oldow, p. 1

Dating methods Stragraphic or geologic methods. Thomas INGICCO

Exploring new fields of Applications using Multi Collector Magnetic Sector MS

DATA REPOSITORY ITEM: METAMORPHIC-AGE DATA AND TEXTURES

AMHERST COLLEGE Department of Geology GEOLOGY 41 - Environmental and Solid Earth Geophysics Lab 2: Geochronology Solution

CLOSURE TEMPERATURES OF ACCESSORY MINERALS

AND LIMITATIONS K. BALOGH

Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS)

USE OF DISCRETE-DYNODE SECONDARY ELECTRON MULTIPLIERS WITH FARADAYS A REDUCED VOLUME

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

GSA Data Repository Denyszyn, et al., 2018, A bigger tent for CAMP: Geology,

DR DATA REPOSITORY

Temperature and Pressure Sensor Interfaces for the ATTA Experiment. Ashleigh Lonis Columbia University REU 2012

Major element compositions of the minerals were obtained on polished thin sections using a

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

When good zircons go bad Redistribution of Radiogenic Pb in Granulite Grade Zircon, Snowbird Tectonic Zone, Canada

Evolution of the Slave Province and Abitibi Subprovince Based on U-Pb Dating and Hf Isotopic Composition of Zircon

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Introduction to Elemental Analysis

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Single zircon U/Pb analyses were performed at the Berkeley Geochronology Center. After using

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Intro to Quantitative Geology

1. The range of frequencies that a measurement is sensitive to is called the frequency

05 - Scintillation detectors

Effect of Sampling Depth on the Analyte Response in Laser Ablation Inductively Coupled Plasma Mass Spectrometry

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

high temp ( K) Chapter 20: Atomic Spectroscopy

Th) ) dating of micro-baddeleyite

Modern Physics Laboratory (Physics 6180/7180)

G 3. AN ELECTRONIC JOURNAL OF THE EARTH SCIENCES Published by AGU and the Geochemical Society

Calculations. λ old. λ new

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Data Repository for 40 Ar/ 39 Ar Age Constraints on the Duration of Resurgence at the Valles Caldera, New Mexico

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Spot Name U-Pb ages (Ma) Plagioclase ages (Ma) Biotite age (Ma) Whole rock age (Ma)

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Noble Gas Mass Spectrometer

U-Pb dating of calcite veins reveals complex stress evolution and thrust sequence in the Bighorn Basin, USA.

Secondary ion mass spectrometry (SIMS)

Extrel Application Note

vacuum analysis plasma diagnostics surface science gas analysis

Treatment of Data. Methods of determining analytical error -Counting statistics -Reproducibility of reference materials -Homogeneity of sample

Transcription:

GSA Data Repository 2016214 Leary, R.J., DeCelles, P.G., Quade, J., Gehrels, G.E., and Waanders, G., 2016, The Liuqu Conglomerate, southern Tibet: Early Miocene basin development related to deformation within the Great Counter Thrust system: Lithosphere, doi:10.1130/l542.1. Detrital U-Pb Geochronology Additional Analytical Methods Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained sandstone beds (from sections 1LQ, 4LQ, 5LQ, 7LQ, and 9LQ; samples LQ-1, LQ-2, and LiuquTuff were collected separately) and 6 fine-grained intervals (from sections 1LQ, 8LQ, and 14LQ) within the Liuqu Conglomerate (see Figs. 2 and 4-9 for locations). These samples were processed according to standard crushing, sieving, water table, magnetic, and heavy liquid procedures. Zircon grains were then mounted in epoxy pucks, polished, and mapped with high resolution BSE imaging at the University of Arizona Laserchron Center. U-Pb ages of zircon grains were determined using Laser Ablation Inductively Coupled Plasma Mass Spectrometetry (LA-ICPMS) (Gehrels et al., 2006, 2008; Gehrels and Pecha, 2014) at the University of Arizona LaserChron Center. Most samples were ablated using a Photon Machines Analyte G2 excimer laser with a standard spot size of 30 microns. The ablated material was carried in helium gas into the plasma source of a Nu HR ICPMS equipped with a flight tube of sufficient width that U, Th, and Pb isotopes can be measured simultaneously. All measurements were made in static mode, using Faraday detectors with 3x10 11 ohm resistors for 238 U, 232 Th, 208 Pb- 206 Pb, and discrete dynode ion counters for 204 Pb and 202 Hg. Ion yields were ~0.8 mv per ppm. Each analysis consisted of one 15-second integration on peaks with the laser off (for backgrounds), 15 one-second integrations with the laser firing, and a 30 second delay to purge the previous sample and prepare for the next analysis. The ablation pits were ~15 microns in depth. For each analysis, the errors in determining 206 Pb/ 238 U and 206 Pb/ 204 Pb resulted in a measurement error of ~1-2% (at 2-sigma

level) in the 206 Pb/ 238 U age. The errors in measurement of 206 Pb/ 207 Pb and 206 Pb/ 204 Pb also resulted in ~1-2% (at 2-sigma level) uncertainty in age for grains that are >1.0 Ga, but are substantially larger for younger grains due to low intensity of the 207 Pb signal. For most analyses, the cross-over in precision of 206 Pb/ 238 U and 206 Pb/ 207 Pb ages occurs at ~1.0 Ga. 204 Hg interference with 204 Pb was accounted for by measurement of 202 Hg during laser ablation and subtraction of 204 Hg according to the natural 202 Hg/ 204 Hg of 4.35. This Hg is correction was not significant for most analyses because our Hg backgrounds were low (generally ~150 cps at mass 204). Common Pb correction was accomplished by using the Hg-corrected 204 Pb and assuming an initial Pb composition from Stacey and Kramers (1975). Uncertainties of 1.5 for 206 Pb/ 204 Pb and 0.3 for 207 Pb/ 204 Pb were are applied to these compositional values based on the variation in Pb isotopic composition in modern crystal rocks. Inter-element fractionation of Pb/U is generally ~5%, whereas apparent fractionation of Pb isotopes is generally <0.2%. In-run analysis of fragments of a large zircon crystal (every sixth measurement) with known age of 563.5 ± 3.2 Ma (2-sigma error) was used to correct for this fractionation. The uncertainty resulting from the calibration correction was generally 1-2% (2- sigma) for both 206 Pb/ 207 Pb and 206 Pb/ 238 U ages. Concentrations of U and Th were calibrated relative to a Sri Lanka zircon, which contains ~518 ppm of U and 68 ppm Th. Additional samples were analyzed via ablation of zircon with a Photon Analyte G2 excimer laser equipped with HelEx ablation cell using a spot diameter of 20 microns. The ablated material was carried in helium into the plasma source of an Element2 HR ICPMS, which sequences rapidly through U, Th, and Pb isotopes. Signal intensities were measured with an SEM that operates in pulse counting mode for signals less than 50K cps, in both pulse-counting

and analog mode for signals between 50K and 4M cps, and in analog mode above 4M cps. The calibration between pulse-counting and analog signals was determined line-by-line for signals between 50K and 4M cps, and was applied to 4M cps signals. Four intensities are determined and averaged for each isotope, with dwell times of 0.0052 sec for 202, 0.0075 sec for 204, 0.0202 sec for 206, 0.0284 sec for 207, 0.0026 sec for 208, 0.0026 sec for 232, and 0.0104 sec for 238. With the laser set to an energy density of ~5 J/cm 2, a repetition rate of 8 hz, and an ablation time of 10 seconds, ablation pits are ~12 microns deep. Sensitivity with these settings is approximately ~5,000 cps/ppm. Each analysis consists of 5 sec. on peaks with the laser off (for backgrounds), 10 sec. with the laser firing (for peak intensities), and a 20 second delay to purge the previous sample and save files. MC-LA-ICPMS data were reduced using the program AgeCalc, while Single Collector data were reduced using the Python decoding routine E2AgeCalc. See www.laserchron.org for additional information. Uncertainties shown for individual grains in the supplemental data are at the 1-sigma level, and include only measurement errors, and systematic uncertainties for each sample are reported separately. Analyses that are >20% discordant or >5% reverse discordant are reported in the supplemental data but are not considered in interpretive aspects of this study. Detrital Zircon Hf Analysis Analyses were conducted with a Nu HR ICPMS connected to a Photon Machines Analyte G2 excimer laser using methods described by Gehrels and Pecha (2014). Instrument settings were established first by analysis of 10 ppb solutions of JMC475 and a Spex Hf solution, and then by analysis of 10 ppb solutions containing Spex Hf, Yb, and Lu. The mixtures ranged in concentration of Yb and Lu, with 176 (Yb+Lu) up to 70% of the 176 Hf. When all solutions yielded

176 Hf/ 177 Hf of ~0.28216, instrument settings were optimized for laser ablation analyses and seven different standard zircons (Mud Tank, 91500, Temora, R33, FC52, Plesovice, and Sri Lanka) were analyzed. These standards were included with unknowns on the same epoxy mounts. When precision and accuracy were acceptable, unknowns were analyzed using exactly the same acquisition parameters. Laser ablation analyses were conducted with a laser beam diameter of 40 microns, with the ablation pits located on top of the U-Pb analysis pits. CL images were used to ensure that the ablation pits did not overlap multiple age domains or inclusions. Each acquisition consisted of one 40-second integration on backgrounds (on peaks with no laser firing) followed by 60 onesecond integrations with the laser firing. Using a typical laser fluence of ~5 J/cm2 and pulse rate of 7 hz, the ablation rate was ~0.8 microns per second. Each standard was analyzed once for every ~20 unknowns. Isotope fractionation was accounted for using the method of Woodhead et al. (2004): Hf was determined from the measured 179 Hf/ 177 Hf; Yb was determined from the measured 173 Yb/ 171 Yb (except for very low Yb signals); Lu was assumed to be the same as Yb; and an exponential formula is used for fractionation correction. Yb and Lu interferences were corrected by measurement of 176 Yb/ 171 Yb and 176 Lu/ 175 Lu (respectively), as advocated by Woodhead et al. (2004). Critical isotope ratios were 179 Hf/ 177 Hf =0.73250 (Patchett & Tatsumoto, 1980); 173 Yb/ 171 Yb = 1.132338 (Vervoort et al. 2004); 176 Yb/ 171 Yb =0.901691 (Vervoort et al., 2004; Amelin and Davis, 2005); 176 Lu/ 175 Lu = 0.02653 (Patchett, 1983). All corrections were done line-by-line. For very low Yb signals, Hf is used for fractionation of Yb isotopes. The corrected 176 Hf/ 177 Hf values were filtered for outliers (2-sigma filter), and the average and standard error

were calculated from the resulting ~58 integrations. There is no capability to use only a portion of the acquired data. All solutions, standards, and unknowns analyzed during a session were reduced together. The cutoff for using Hf versus Yb was determined by monitoring the average offset of the standards from their known values, and the cutoff was set at the minimum offset. For most data sets, this is achieved at ~6 mv of 171 Yb. For sessions in which the standards yield 176 Hf/ 177 Hf values that are shifted consistently from the know values, a correction factor was applied to the 176 Hf/ 177 Hf of all standards and unknowns. This correction factor, which is not necessary for most sessions, averages 1 epsilon unit. The 176 Hf/ 177 Hf at time of crystallization was calculated from measurement of presentday 176 Hf/ 177 Hf and 176 Lu/ 177 Hf, using the decay constant of 176 Lu (λ = 1.867e -11 ) from Scherer et al. (2001) and Söderlund et al. (2004). No capability is provided for calculating Hf Depleted Mantle model ages because the 176 Hf/ 177 Hf and 176 Lu/ 177 Hf of the source material(s) from which the zircon crystallized is not known. 40 Ar/ 39 Ar Analysis Analyses were carried out at the Arizona Noble Gas Laboratory at the University of Arizona. Handpicked biotite grains were irradiated at the USGS TRIGA Reactor, Denver, Colorado along with flux monitors to calculate J-factors and K 2 SO 4 and CaF 2 salts to calculate correction factors for interfering neutron reactions. Following a 2 to 3 week cooling period to allow for the decay of short-lived isotopes, samples were loaded into the arms of a glass storage tree above a double-vacuum, resistance-heated furnace and heated to 120 at the same time that the entire extraction line was baked for 48 hours at 220 C. Getters and furnace were

independently degassed near the end of the bake-out. Samples were then dropped into the furnace and argon was extracted from each sample using a computer controlled step-heating routine with 12 individual steps. The temperature of the furnace is estimated to be accurate to ± 20 C. Each heating step had a duration of 12 minutes followed by a cool down to 500 C prior to advancing the gas into two successive gettering stages for argon purification. The argon was then admitted into a VG 5400 mass spectrometer, where it was ionized and detected by a VG electron multiplier and digitized with a Keithley 617 Electrometer. Data collection and processing were accomplished using the computer program Mass Spec (Deino, 2001). The decay constants used were those recommended by Renne et al. (2010). Baseline values were subtracted and the isotopic measurements then were regressed to time zero using standard linear regression techniques. Additional corrections and associated uncertainties were applied to account for blanks, machine discrimination, atmospheric contribution, and interfering isotopes produced in the reactor from Ca, K and Cl present in the samples. 2016214_SupplementalData.xlsx