Agilent Intuvo 9000 Gas Chromatograph System

Similar documents
The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Understanding Gas Chromatography

Agilent G2350A Atomic Emission Detector (AED)

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Agilent 5977A Series GC/MSD System

Introduction to Capillary GC

Petrochemical. Transformer Oil Gas Analysis - TOGA

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

Introducing 7820A GC System. Reliability, Simplicity & Affordability!

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

2401 Gas (liquid) Chromatography

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

U.S. EPA Method 8270 for multicomponent analyte determination

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

GAS CHROMATOGRAPHY (GC)

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

USP<467> residual solvents

brochure brief 5973Network Mass Selective Detector General Description and Configurations

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Activity in the FID Detection Port: A Big Problem if Underestimated

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Gas chromatography. Advantages of GC. Disadvantages of GC

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Author. Abstract. Introduction

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

COOKBOOK FOR THE PERKINELMER SWAFER TM TECHNOLOGY FOR GC APPLICATIONS

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Analytical Instrumentation

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

Trajan SGE GC Columns

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

costech instruments ECS 4010 Elemental Combustion System CHNS-O

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

1.0 Reactive Gas Chromatography Design and Setup Procedure for Catalyst Pelletization & Inlet Packing Software and Method.

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Ultra-Inert chemistry for Trace Level Analysis

Selection of a Capillary GC Column

Application. Gas Chromatography February Introduction

Introduction to Capillary GC

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Application Note 032

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Gas Chromatography (GC)

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Application Note S/SL

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

DET REPORT. 1.) CATALYTIC COMBUSTION IONIZATION DETECTION (CCID) - MORE CHARACTERISTICS OF THE SELECTIVITY FOR n PARAFFINS. NO.

Introduction to Gas Chromatography

Secrets of GC Column Dimensions

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Experiment 6 Simple and Fractional Distillation

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Chapter 31 Gas Chromatography. Carrier Gas System

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Rapid Catalyst Screening Reactors

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

GC Instruments. GC Instruments - Sample Introduction

Luminescence transitions. Fluorescence spectroscopy

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Paints and varnishes Determination of volatile organic compound (VOC) content. Part 2: Gas-chromatographic method

Highly Sensitive and Rugged GC/MS/MS Tool

Sulfotepp impurities in Chlorpyrifos EC formulations

The Pulsed Flame Photometric Detector for analysis of phosphorus pesticides in wastewater and food commodities

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Detection of Chemical Warfare Agents by Transportable GC/MS

ENVIRONMENTAL analysis

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Transcription:

Agilent Intuvo 9000 Gas Chromatograph System Data Sheet The Agilent Intuvo 9000 GC System is a new breed of GC from the industry leader in GC innovation. Intuvo accomplishes GC in a completely new way, and clears a completely new path to productivity. Intuvo brings you a suite of enabling technologies unavailable elsewhere: Direct heating, shorter cycle times Planar column design Fast, confident column changes Click and run connections An end to column trimming Intuvo Guard Chip technology Critical instrument information instantly Intuitive touch screen More free lab space Half the footprint of a conventional oven GC Visit www.agilent.com/chem/intuvo, and discover just how much innovation Agilent has managed to pack into such a small box.

Chromatographic Performance* Retention time repeatability < 0.008 % or < 0.0008 minutes Area repeatability < 1 % RSD System Capabilities Supports: Inlets: SSL, MMI Detectors: FID, TCD, ECD, NPD, FPD, SCD/NCD, Mass Spec (single and triple quad) Four detector signals State-of-the-art detector electronics and the full-range digital data path enable peaks to be quantified over the entire concentration range of the detector (10 7 for the FID) in a single run. Full EPC is available for all inlets and detectors. Control range and resolution are optimized for the specific inlet or detector module. Pressure setpoint and control precision to 0.001 psi provides more retention time locking precision for low-pressure applications. EPC provides four column flow control modes: constant pressure, ramped pressure (three ramps), constant flow, or ramped flow (three ramps). Column average linear velocity is calculated. Atmospheric pressure and temperature compensation is standard, so results do not change, even when the laboratory environment changes. Automatic leak checking can be enabled by user for every run or run any time during maintenance or diagnostic tasks. System alerts the user when a leak is detected so immediate action can be taken to correct and minimize downtime. A run time deviation log is created for each analysis to ensure that all method parameters were achieved and maintained. Automatic Liquid Sampling is fully integrated into GC control. Display of all GC and ALS setpoints at the GC or data system. Built-in context sensitive help available on color touchscreen interface. Web interface available to view status, user information, and monitor runs. GC Color Touchscreen Interface Available in English, Chinese, or Japanese Column Oven Accommodates up to two 30 m 0.320 mm id capillary columns or one 60 m 0.320 mm id capillary column Support columns 0.100 mm to 0.320 mm id Operating temperature range suitable for all columns and chromatographic separations. Ambient temperature +10 C to 450 C Temperature setpoint resolution: 0.1 C Supports 20 oven ramps with 21 plateaus. Negative ramps are allowed. Maximum achievable temperature ramp rate: 250 C/min Maximum run time: 999.99 minutes (16.7 hours) Oven cool down (22 C ambient) 450 to 50 C in less than 3 minutes Electronic Pneumatics Control (EPC) Compensation for barometric pressure and ambient temperature changes is standard, Pressure has typical control of 0.001 psi for the range of 0 to 150 psi. Pressure setpoints may be adjusted in increments of 0.001 for the range 0.000 to 99.999 psi; 0.01 psi for the range 100.00 to 150.00 psi. User may select pressure units as psi, kpa, or bar. Pressure/flow ramps: Three maximum. Carrier and makeup gas settings selectable for He, H 2, N 2, and argon/methane. Flow or pressure setpoints for each inlet or detector parameter with both Agilent Intuvo 9000 and Agilent data system software. Constant flow mode is available when capillary column dimensions are loaded from the installed column(s) through the Agilent Intuvo Smart ID Key, or manually entered. *Using an Agilent Intuvo 9000 with EPC (splitless), ALS, and Agilent Data System for analysis of tetradecane (2 ng to the column). Results may vary with other samples and conditions. 2

Split/splitless and Multimode inlets have flow sensors for the control of split ratio. Inlet modules Pressure sensors Accuracy < ±2 % full scale Repeatability < ±0.05 psi Temperature coefficient <±0.01 psi/ C Drift < ±0.1 psi/6 months Flow sensors Accuracy Repeatability Temperature coefficient < ±5 % depending on carrier gas < ±0.35 % of setpoint < ±0.20 ml/min (NTP)* per C for He or H 2 ; < ±0.05 ml/min NTP per C for N 2 or Ar/CH 4 *NTP = 25 C and 1 atmosphere Detector modules Accuracy <±3 ml/min NTP or 7 % or setpoint Repeatability <±0.35 % or setpoint Inlets Maximum of one inlet installed EPC compensated for atmospheric pressure and temperature variation S/SL Split ratios up to 7,500:1 to avoid column overload. Setting split ratios (particularly low split ratios) is limited by column parameters and control of system flows (particularly low system flows). Splitless mode for trace analysis. Pressure-pulsed splitless is easily accessible for best performance. Maximum temperature: 400 C. EPC available in two pressure ranges: 0 to 100 psig (0 to 680 kpa) for best control for columns 0.200 mm diameter; 0 to 150 psig for columns < 0.200 mm diameter. Gas saver mode to reduce gas consumption without compromising performance. Electronic septum purge flow control to eliminate ghost peaks. Total flow setting range: 0 to 500 ml/min N 2 0 to 1,250 ml/min H 2 or He Turn top inlet sealing system is built in standard with each Agilent Intuvo 9000 S/SL inlet for quick, easy, injector liner changes. Optional inert S/SL inlet includes chemical deactivation process for weldment and weldment insert. MMI Provides the flexibility of a standard Agilent split/splitless inlet, combined with temperature programmable capabilities which allow for large volume injection. Temperature control: LCO 2 (to 70 C), air cooling (to ambient +10 C with oven temperature < 50 C) (due to high consumption, air cooling with cylinders is not advised). Temperature programming of up to 10 ramps at up to 900 C/min. Maximum temperature: 450 C. Injection modes: Hot or cold split/splitless Pulsed split/splitless Solvent vent Direct Suitable for all capillary columns that Intuvo supports. EPC pressure range (psig): 0 to 100 psig Split ratio: up to 7,500 to 1 to avoid column overload. Setting split ratios (particularly low split ratios) is limited by column parameters and control of system flows (particularly low system flows). Splitless mode for trace analysis. Pressure pulsed splitless is easily accessible for improved performance. Electronic septum purge flow control Compatible with Merlin Microseal septum Setup of parameters facilitated with Agilent Solvent Elimination Calculator Total flow setting range: 0 to 500 ml/min N 2 0 to 1,250 ml/min H 2 or He Turn-top inlet sealing system is built in standard with each Agilent Intuvo 9000 Multimode inlet for quick, easy injector liner changes. Detectors Electronic pneumatics control and electronic on/off for all detector gases EPC compensated for atmospheric pressure and temperature variation Flame ionization detector (FID) FID that responds to most organic compounds Minimum detectable level (for tridecane): <1.4 pg C/s Linear dynamic range: >10 7 (±10 %). Full-range digital data path enables peaks to be quantified over the entire 10 7 concentration range in a single run. 3

Data rates up to 1,000 Hz accommodate peaks as narrow as 10 msec at half height. Standard electronic pneumatic control for three gases: Air: 0 to 800 ml/min H 2 : 0 to 100 ml/min Makeup gas (N 2 or He): 0 to 100 ml/min Capillary only configuration Flameout detection and automatic re-ignition 450 C maximum operating temperature Thermal conductivity detector (TCD) A universal detector that responds to all compounds, excluding the carrier gas. Minimum detectable level: 400 pg tridecane/ml with He carrier. (This value may be affected by laboratory environment). Linear dynamic range: >10 5 ± 5 % Unique fluidic switching design provides rapid stabilization from turn-on, low-drift performance. Signal polarity can be run programmed for components having higher thermal conductivity than the carrier gas. Maximum temperature: 400 C Standard EPC for 2 gases (He, H 2, or N 2 matched to carrier gas type) Make-up gas: 0 to 12 ml/min Reference gas: 0 to 100 ml/min Micro-ECD Micro-electron capture detector (micro-ecd), a very sensitive detector for electrophilic compounds such as halogenated organic compounds. Minimum detectable level: < 4.4 fg/ml lindane At standard checkout conditions, with a detector temperature of 300 C and flow to the detector (makeup plus column) of 30 ml/min N 2, this is equivalent to 4.5 fg/sec. Proprietary signal linearization Linear dynamic range: > 5 10 4 with lindane Data acquisition rate: up to 50 Hz Uses β emission of < 15 mci 63 Ni as the electron source. Unique micro-cell design minimizes contamination and optimizes sensitivity. Maximum temperature: 400 C Standard EPC makeup gas types: argon/5 % methane or nitrogen; 0 to 150 ml/min Nitrogen-phosphorus detector (NPD) NPD with Blos (glass) bead, a detector specific to nitrogen or phosphorus-containing compounds. With azobenzene/malathion/ octadecane mixture: MDL of <0.08 pg N/sec MDL of <0.01 pg P/sec Dynamic range >10 5 for Nitrogen Dynamic range >10 5 for Phosphorus Selectivity of >25,000 to 1 (g N/g C) Selectivity of >200,000 to 1 (g P/g C) Data rates from 0.1 to 1,000 Hz Air flow settable from 0 to 200 ml/min Hydrogen flow settable from 0 to 20 ml/min Makeup gas (He or N 2 ) flow settable from 0 to 100 ml/min Maximum temperature: 400 C Flame Photometric Detector (FPD) + (Plus) Single-wavelength FPD, a sensitive, specific detector to sulfur- or phosphorus-containing compounds. With methyl parathion: MDL < 45 fg P/sec MDL < 2.5 pg S/sec Dynamic range of >10 3 S Dynamic range of >10 4 P Selectivity of 10 6 g S/g C Selectivity of 10 6 g P/g C Data rates from 0.1 to 200 Hz Air flow settable from 0 to 200 ml/min H 2 flow settable from 0 to 250 ml/min Makeup gas (N 2 ) flow settable from 0 to 130 ml/min Maximum transfer line temperature of 400 C SCD (Model 8355) Highest sensitivity and selectivity for sulfur-containing compounds MDL: Typical < 0.5 pg/s, dimethyl sulfide in toluene Linear dynamic range: > 10 4 Selectivity: > 2 10 7 g S/g C NCD (Model 8255) High selectivity for nitrogen containing compounds. MDL: < 3 pg N/s, in both N and nitrosamine modes, 25 ppm N as nitrobenzene in toluene 4

Linear dynamic range: > 10 4 Selectivity: > 2 10 7 g N/g C (selectivity in nitrosamine mode is matrix dependent) See Agilent Sulfur Chemiluminescence Detector and Nitrogen Chemiluminescence Detector Specification Guide for additional information regarding performance and physical and environmental specifications. Mass Spectrometers See Agilent 5977 Series MSD specifications. See Agilent 7000/7010 Triple Quadrupole GC/MS specifications. Data Communications LAN Two analog output channels (1-mV, 1-V, and 10-V output available) as standard Remote start/stop Binary-coded decimal input for a stream selection valve Maintenance and Support Services Integrated early maintenance counters allows planned maintenance and helps eliminate unnecessary downtime. Instrument events or shutdowns displayed on keyboard display or Data System Remote diagnostics Performance verification services Easy parts identification and part number finder software (standalone software, does not require Agilent CDS) Dimensions and Weight Height Width Depth Weight 51 cm (20 in) 27 cm (10.7 in) 69 cm (27.2 in) 31.8 kg (70 lbs) Environmental Conditions Ambient operating temperature: 15 C to 35 C Ambient operating humidity: 5 % to 95 % (noncondensing) Storage extremes: 40 C to 70 C Power requirements: Line voltage: 120/200/220/230/240 Volts ±10 % of nominal Frequency: 50/60 Hz Safety and Regulatory Certification Conforms to the following safety standards: Canadian Standards Association (CSA) C22.2 No. 60101-1 Nationally Recognized Test Laboratory (NRTL): ANSI/UL61010 1 International Electrotechnical Commission (IEC): 61010-1, 60101 2-010, 60101-2-081 EuroNorm (EN): 61010-1 Conforms to the following regulations on Electromagnetic Compatibility (EMC) and Radio Frequency Interference (RFI): CISPR 11/EN 55011: Group 1 Class A IEC/EN 61326 AUS/NZ CISPR11 This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada. Designed and manufactured under a quality system registered to ISO9001, Declaration of Conformity available. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. Merlin Microseal is a trademark of Merlin Instrument Company. 5

www.agilent.com/chem/intuvo This information is subject to change without notice. Agilent Technologies, Inc., 2016 Published in the USA, September 1, 2016 5991-7321EN