DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Similar documents
DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

DiatoSorb-W High Performance Chromatographic Diatomaceous Earth (DE)

Virtually Particle-Free Rt -Silica BOND Columns

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Water Injections in GC - Does Water Cause Bleed?

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Definitive EtG/EtS LC-MS/MS Analysis:

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds

Determination of Normal Hydrocarbons C 5 -C 18 Using Silanized Algerian Bentonite (B 1100 ) as Support in Gas Chromatographic Analysis

Activity in the FID Detection Port: A Big Problem if Underestimated

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Headspace Technology for GC and GC/MS: Features, benefits & applications

Understanding Gas Chromatography

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

[ a ppl ic at ion no t e ]

Application Note 059 Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Making Improvements to Today s Natural Gas Analysis Systems

Determination of the Boiling-Point Distribution by Simulated Distillation from n-pentane through n-tetratetracontane in 70 to 80 Seconds

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

CHAPTER 6 GAS CHROMATOGRAPHY

A New Web-Based Application for Modeling Gas Chromatographic Separations

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Chemistry Gas Chromatography: Separation of Volatile Organics

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

Introduction and Principles of Gas Chromatography

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Volatile Organic Compounds in Every Day Food

Rely on Rxi -PAH Columns

Evaluation of Capillary Columns for General Performance Parameters

Determination of Solubility Parameters using Inverse Gas Chromatography

Industrial Applications with a New Polyethylene Glycol-Based GC Column

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

Recent advances in Inverse Gas Chromatography - IGC - measurements of HSP. RALF DUEMPELMANN, ERIC BRENDLE and STEVEN ABBOTT

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Get Selective. By Jaap de Zeeuw

Ultra-Inert chemistry for Trace Level Analysis

High Purity Chromasolv Solvents

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Optimizing GPC Separations

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Hypersil BDS Columns TG 01-05

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Automated Characterization of Compounds in Fire Debris Samples

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

for Acclaim Mixed-Mode HILIC-1 Column

SECOBARBITAL Latest Revision: February 15, 1999

GAS CHROMATOGRAPHY (GC)

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Trajan SGE GC Columns

Chapter 27: Gas Chromatography

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Chemistry Instrumental Analysis Lecture 28. Chem 4631

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

How To Select the Correct GC Column. Simon Jones Application Engineer

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

GC Columns PLOT Columns

Instrumental Chemical Analysis

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Chromatography. Gas Chromatography

Pittcon P

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

Gas Chromatography (GC)

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Certified BTEX in Unleaded Gas Composite

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Selection of a Capillary GC Column

Introduction to Chromatography

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

ChromegaChiral TM CSP Media and Columns

Transcription:

Restek GC DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Officially listed USP SA and SNS support material. Ideal for USP and ASTM methods that use white diatomaceous earth. Rigorous QC testing assures consistent quality and improved packed column performance. Always available avoid costly back order delays. Pure Chromatography

Consistent in Quality and Supply Finally, a Reliable Source for Diatomaceous Earth Virtually unlimited in supply but only available from Restek new DiatoSorb-W offers a reliable alternative for packed column users. After years of dealing with diatomaceous earth being in short supply, users of chromatographic grade material now have a reliable new source. Whether you need diatomaceous earth columns or custom packing materials, DiatoSorb-W products from Restek are always available and consistent in quality. As a leader in packed column technology, Restek has engineered an improved, saltwater-based diatomaceous earth product called DiatoSorb-W, which is available in acid-washed (WAW), nonacid-washed (WNAW), and high-performance (WHP) varieties. Based on its superior performance, DiatoSorb-W solid support has replaced the commercially available white diatomaceous earth brand that was previously used in Restek GC packed columns and Silcoport W columns. We now pair DiatoSorb-W solid support with our stationary phases and inert tubing types to ensure our white diatomaceous earth columns provide the inertness and stability you need for your challenging separations. We also offer a wide variety of stationary phases on DiatoSorb-W solid support in 0/0, 0/00, and 00/0 mesh sizes for those who pack their own columns. Figure : Tight QC specifications for DiatoSorb-W particle size distribution result in high-efficiency, narrow peaks, and better separation of closely eluting compounds. DiatoSorb-W Non-DiatoSorb-W, 0 0 GC_PC9 0.0.0.0.0.0 0.0.0.0.0 GC_PC9 Column: % OV-, 0.% Versamid 900, 00/0 mesh on diatomaceous earth, SilcoSmooth tubing, m, ¹/₈ in OD, mm ID; Sample: Methadone (cat.# 00), Cocaine (cat.# 0), Codeine (cat.# 000), Morphine (cat.# 00); Conc.: 0 µg/ml; Inj. Vol.: µl on-column; Inj. Temp.: 0 C; Oven Temp.: 0 C (hold min); Carrier Gas: He, constant flow at 0 ml/min; Detector: FID @ C; Instrument: Agilent 90B GC; Peaks:. Cocaine,. Codeine,. Methadone,. Heroin,. Oxycodone,. Desomorphine,. Hydrocodone. All DiatoSorb-W solid support undergoes rigorous quality testing to ensure high purity and dependable performance. QC testing includes particle size distribution, density control, and chromatographic analysis to ensure inertness and reproducibility. Every mesh size of DiatoSorb-W raw material is QC tested for particle size distribution and density to ensure it meets our stringent quality control specifications. The particle size distribution of DiatoSorb-W is extremely narrow, resulting in higher efficiencies and narrower peaks than were obtained on a similar column packed with a non-diatosorb-w support (Figure ). The basic compounds shown in this comparison clearly show much better resolution and peak shape on the DiatoSorb-W diatomaceous earth column than on the non-diatosorb column made with the same tubing and stationary phase.

9 0 9 0 Along with particle size distribution, small pore size and high density and surface area also contribute to packed column efficiency, compound resolution, retention time reproducibility, and overall data quality. These characteristics accommodate higher stationary phase loading, resulting in higher efficiency and improved resolution, as well as consistent retention time reproducibility. The D chromatograms in Figure illustrate the excellent separation of closely eluting hydrocarbons that is achieved using a high-efficiency DiatoSorb-W packed column. The same analysis on a non-diatosorb diatomaceous earth column results in broader peak widths and poorer resolution. Figure : Highly efficient DiatoSorb-W packed columns provide excellent results for simulated distillation. DiatoSorb-W 9 0 0 0 0 0 GC_PC99 Non-DiatoSorb-W Non-DiatoSorb-W diatomaceous earth columns show wider peak shapes and poorer separations for simulated distillation. 9 0 0 0 0 0 GC_PC9 Column: Rtx- SimDist, 00/0 mesh on diatomaceous earth, SilcoSmooth tubing, in, ¹/₈ in OD,.0 mm ID; Sample: % w/w ASTM D- calibration standard (cat.# ) in carbon disulfide; Inj. Vol.: 0. µl on-column; Inj. Temp.: 0 C; Oven Temp.: C to 0 C at 0 C/min (hold min); Carrier Gas: He, constant flow at ml/min; Detector: FID @ 0 C; Instrument: Agilent 90B GC; Peaks:. n-pentane,. n-hexane,. n-heptane,. n-octane,. n-nonane,. n-decane,. n-undecane,. n-dodecane, 9. n-tetradecane, 0. n-pentadecane,. n-hexadecane,. n-heptadecane,. n-octadecane,. n-eicosane,. n-tetracosane,. n-octacosane,. n-dotriacontane,. n-hexatriacontane, 9. n-tetracontane, 0. n-tetratetracontane.

Rigorous DiatoSorb-W QC Standards Ensure Accurate, Reproducible Results In addition to high efficiency, reproducibility and inertness are key requirements for consistent, high-quality packed column performance. The lot-to-lot comparison in Figure demonstrates the excellent retention time reproducibility that results from Restek s rigorous quality standards and specifications. Because inertness is critical for obtaining accurate data, each batch of DiatoSorb-W is QC analyzed so consistently superior chromatographic performance can be assured. Figure compares results for diatomaceous earth columns from different suppliers (all columns are packed with white diatomaceous earth supports coated with % OV-0 polymer). The packed columns made with DiatoSorb-WHP support and SilcoSmooth tubing are highly inert and clearly outperform competitor columns as demonstrated by the α-cholestane/ cholesterol area ratios. The DiatoSorb-W column produces a ratio of nearly.0; whereas, scores of. and. on columns from other vendors indicate that compound adsorption is occurring due to poor deactivation and active sites in the column. Table I: Each lot of DiatoSorb-W diatomaceous earth solid support is QC analyzed to ensure superior chromatographic performance. Quality Parameters Average (n = 9) Standard Deviation (n = 9) %RSD (n = 9) Retention time, min (cholesterol).9 0.. Efficiency (cholesterol),9 0 Peak area ratio (α-cholestane/cholesterol). 0.0 0. Figure : Excellent retention time reproducibility of DiatoSorb-W diatomaceous earth is ensured by tightly controlled manufacturing and strict QC testing. Lot Lot Lot.0.0 GC_PC Column: % OV-0, 00/0 mesh on DiatoSorb-WHP, SilcoSmooth tubing, ft., ¹/₈ in OD,.0 mm ID; Sample:,000 µg/ml α-cholestane and cholesterol in dichloromethane; Inj. Vol.: µl packed on-column; Inj. Temp.: 0 C; Oven Temp.: 0 C (hold min); Carrier Gas: He, constant flow at 0 ml/min @ 0 C; Detector: FID @ C; Instrument: Agilent 90B GC; Peaks:. α-cholestane,. Cholesterol.

Figure : All DiatoSorb-W material undergoes rigorous quality testing to ensure high purity and dependable performance. DiatoSorb-W columns are highly inert, ensuring excellent peak shape and response. DiatoSorb-W Peak area ratio (α-cholestane/cholesterol) =. 0 Peak asymmetry =. Put the Power of Restek Packed Columns to Work for You /packedgc GC_PC00 Vendor A Instrument Conditions for Figure : Columns: % OV-0, 00/0 mesh on diatomaceous earth solid support; Tubing: SilcoSmooth tubing, m, / in OD, mm ID (DiatoSorb-WHP) and glass column, m, / in OD, mm ID (Vendors A and B); Sample:,000 µg/ml cholesterol and α-cholestane in chloroform; Inj. Vol.:.0 µl on-column; Inj. Temp.: 0 C; Oven Temp.: 0 C (hold min); Carrier Gas: He, constant flow at 0 ml/min; Detector: FID @ 0 C; Instrument: Agilent 90B GC; Peaks:. α-cholestane,. Cholesterol. Peak area ratio (α-cholestane/cholesterol) =. 0 Peak asymmetry =. GC_PC0 Vendor B Peak area ratio (α-cholestane/cholesterol) =. Peak asymmetry =. 0 GC_PC0

Consistent Performance Means Results You Can Trust for Critical Applications All characteristics of DiatoSorb-W solid support are tightly controlled and rigorously tested, which ensures that DiatoSorb-W packed columns will work dependably for vital applications. For example, accurate solvent analysis is critical for ensuring the safety of finished pharmaceutical products as well as for controlling solvent content in waste streams. As shown in Figure, DiatoSorb-W diatomaceous earth columns are a great choice for this analysis because the high surface area of the DiatoSorb-W solid support increases the coating capacity of the polymer, resulting in a column with high efficiency that is able to separate even the most volatile solvents. The analysis of underivatized free fatty acids in Figure is another example of how DiatoSorb-W packed columns perform well for difficult applications. In this case, the high inertness of the DiatoSorb-W column allows these reactive compounds to be monitored reliably even at low levels. Figure : Even volatile solvents can be retained and reliably separated on high-efficiency DiatoSorb-W diatomaceous earth columns. 0.0.0.0.0.0.0 GC_PH Column: 0% OV-0, 0.% CW-00, 00/0 mesh on DiatoSorb-WHP, SilcoSmooth tubing, m, ¹/₈ in OD, mm ID; Sample: Equal proportions of neat compounds; Inj. Vol.: 0. µl on-column; Inj. Temp.: 00 C; Oven Temp.: 00 C (hold min); Carrier Gas: He, constant flow at 0 ml/min; Detector: FID @ 0 C; Instrument: Agilent 90B GC; Peaks:. Methanol,. Ethanol,. Acetone,. Methyl ethyl ketone (MEK);. Isopropyl acetate;. -Nitropropane;. Methyl isobutyl ketone (MIBK);. Toluene. Figure : Highly inert DiatoSorb-W packed columns are ideal for analyzing underivatized free fatty acids. 9 0 0 0 GC_PC9 Column: 0% FFAP, % HPO, 00/0 mesh on DiatoSorb-WHP, SilcoSmooth tubing, m, / in OD, mm ID; Sample:,000 µg/ml fatty acids C-C in ether; Inj. Vol.: µl on-column; Inj. Temp.: 00 C; Oven Temp.: C (hold min) to C at 0 C/min (hold min); Carrier Gas: He, constant flow at 0 ml/min; Detector: TCD @ 0 C; Instrument: Agilent 90B GC; Peaks:. Acetic acid,. Formic acid,. Propionic acid,. Isobutyric acid,. n-butyric acid,. Isovaleric acid,. n-valeric acid,. Isocaproic acid, 9. n-caproic acid, 0. Heptanoic acid.

Switch to DiatoSorb-W Columns Today and Say Goodbye to Long Delivery Times Struggling to find a reliable supply of white diatomaceous earth? Frustrated with the high cost of long delivery times and inconsistent product quality? Save time, money, and aggravation by switching to DiatoSorb-W today. Whether you need packed columns or custom packing materials, DiatoSorb-W is consistent in quality and always available. DiatoSorb Diatomaceous Earth Packed Columns Bonded Stationary Phase Packed Columns Column Instrument Configurations Stainless Steel Tubing SilcoSmooth Tubing** Bonded Phase L OD ID L OD ID on 00/0 Silcoport W*** (ft) (in) (mm) cat.#* (m) (in) (mm) cat.#* % Rtx- /. 0- /.0 00-0% Rtx- /. 0- /.0 00-0% Rtx- /. 0- /.0 009- % Rtx- /. 0- /.0 0-0% Rtx- /. 0- /.0 0-0% Rtx- /. 0- /.0 09- % Rtx-Stabilwax /. 0- /.0 0-0% Rtx-Stabilwax /. 0- /.0 0-0% Rtx-Stabilwax /. 09- /.0 0- Rtx- SimDist **** " /. 00- " /.0 0000- DiatoSorb Diatomaceous Earth Packed Columns Nonbonded Stationary Phase Packed Columns " " General Configuration Suffix -00 Agilent 0, 90, 9, 90, 90: Suffix -0* Bruker 0, 00, Vista Series, FID: Suffix -0 PE 900-90, Sigma,,: Suffix -0 PE Auto System 00, 00, 00 Suffix -0 Stainless Steel Tubing SilcoSmooth Tubing** L OD ID L OD ID On 00/0 Silcoport W*** (ft) (in) (mm) cat.#* (m) (in) (mm) cat.#* % Rt-0 /. 0- /.0 000- % Rt-00/.% Bentone /. 0- /.0 0- % Rt-00/% Bentone /. 0- /.0 09- *Please add column instrument configuration suffix number to cat.# when ordering. **Siltek-treated stainless steel. ***Modified version of DiatoSorb W; highest inertness, most consistent performance. ****Application-specific column. Additional configurations available. Note: Initial " of column will be empty to accommodate a needle. For a completely filled column (not on-column), add suffix -90. *-0 suffix also includes " void on detector side. Note: Standard micropacked columns fit all instruments. No special instrument configuration suffix is required. Custom packings are available for DiatoSorb-W in 0/0, 0/00, and 00/0 mesh sizes. Contact your Restek representative for a quote. Order today! /DiatoSorb-W

Meet the Experts Restek s packed column experts have decades of industry experience. If you have any questions about DiatoSorb-W products or packed column applications, consider them your personal technical resources! Barry Burger Restek s Senior Petrochemical Innovations Chemist, Barry has more than 0 years of chromatography experience and has been a voting member of the ASTM D committee for over a decade. He specializes in petrochemical applications. Barry.Burger@restek.com Jaap de Zeeuw Jaap is a world-renowned chromatographer with over years of experience, including years with Varian/ Chrompack focusing on industrial analysis challenges. Directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena, Restek s International GC Specialist has helped develop new techniques, such as fast GC-MS using vacuum GC technology, and has filed two patents for his work. Jaap.deZeeuw@restek.com Katarina Oden Katarina came to Restek with a B.S. in Chemistry from the University of Ljubljana, Slovenia, and research experience in both commercial and university labs. After three years as a QA Analyst, she joined the Innovations Department, where her work focuses on supporting new product development and applications for the petrochemical market. Katarina.Oden@restek.com Order today! /DiatoSorb-W Pure Chromatography Questions about this or any other Restek product? Contact us or your local Restek representative (/contact-us). Restek patents and trademarks are the property of Restek Corporation. (See /Patents-Trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 0 Restek Corporation. All rights reserved. Printed in the U.S.A. Lit. Cat.# GNBR-UNV