Agilent LC & LC-MS Cannabis Testing

Similar documents
LC-MS/MS Analysis of Phytocannabinoids and their

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Quantitative determination of cannabinoids in Hemp and Hemp products by High Performance Liquid Chromatography using a UV Detector

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Figure 1. Structures for Vitamin B2 and Vitamin B1.

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Figure 1. Structures for Vitamin B2 and Vitamin B1.

The new Agilent 1290 Infinity Quaternary LC

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput

LC and LC/MS Column Selection Flow Chart

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

New York State Department of Health - Wadsworth Center Laboratory of Organic Analytical Chemistry NYS ELAP Laboratory ID 10763

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Fast methods for the determination of ibuprofen in drug products

New York State Department of Health - Wadsworth Center Laboratory of Organic Analytical Chemistry NYS ELAP Laboratory ID 10763

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Too Polar for Reversed Phase What Do You Do?

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

How proteins separate on reverse-phase HPLC

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

High Resolution Fast LC

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Agilent All Ions MS/MS

Agilent InfinityLab SFC Solutions EXTEND YOUR APPLICATION REACH WITH MAXIMUM EFFICIENCY

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

HPLC analysis of VFAs, Furfural and HMF

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

HPLC Praktikum Skript

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Varian Galaxie Chromatography Data System for Preparative HPLC

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Qualification Specifications for Agilent 1100/1200 HPLC Systems

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

QTOF Training Manual

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Agilent ESI and APCI sources: for polar to non-polar compounds

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Application Note. Agilent Application Solution Analysis of acaricides in honey. Authors. Abstract. Food

LC Technical Information

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Automated Sample Preparation in Quality Control of Eye-Drop Formulation

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

GAS CHROMATOGRAPHY (GC)

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Routine MS Detection for USP Chromatographic Methods

for Acclaim Mixed-Mode HILIC-1 Column

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Transcription:

Agilent LC & LC-MS Cannabis Testing Potency Analysis for Cannabinoids Mike Adams 1, A. Roth 1, Joan Stevens 2, Karen Kaikaris 1, & Sue D Antonio 2 1 CWC LABS, 2 Agilent Technologies,

UV detection with UHPLC separation. 1220 1260 Infinity II 1290 Infinity II 2

Compound Tetrahydrocannabivarin (THCV) ( )-trans-δ9-tetrahydrocannabinol (THC) Cannabidiol (CBD) Cannabigerol (CBG) Tetrahydrocannabinolic acid ( Δ9-THCA) Cannabidiolic Acid (CBDA) Cannabinol (CBN) Cannabigerolic acid (CBGA) Cannabichromene (CBC) Cannabidivarin (CBDV) 7696A SAMPLE PREP WORKBENCH 3

The new Agilent 1260 or 1290 Infinity II LC! Significantly improved Workflow Solution! Method-Development Solution Method New development detectors (improved system: specifications) Up to 8 columns (used 6) New Column Compartment (four columns Only up limited by your imagination Flexible pump (quaternary) to 300mm, four-column selection valve, four column tag-reader) Method scouting wizard (builds sequences based on your methods, New Multisampler tells how (Dual-Needle-option much solvent and for sample) wide range injection volumes, fast, lowest Using carry-over) Peak Explorer (OpenLab II) you can review chromatograms in a sequences quickly New quaternary pump (improved usability, additional 12 or 24-fold solvent selection)

Zorbax Bonus-RP Polar-linked alkyl phase 1 1 1 PG PG R R Superb peak shape for basic compounds Long column life (ph 2-8) Unique selectivity Patented bonding technology polar-linked alkyl phase for fast mass 1 transfer giving good peak shape bulky side groups give low ph stability triple endcapped for mid-range ph stability 1 PG R and good peak shape 1

Buffer: 1. 1 vial (2.2 ml) of Ammonium Formate (G1946-85021) 2. 1 ml of Formic Acid (G2452-85060) 3. QS to 1 Liter of LC-MS grade H 2 O Caveat: make sure to flush columns (methanol) after use 6

Testing this method for ruggedness with the QBD approach QBD: Quality by design 1. We used the method development column kit. Three columns of the same type from 3 different lots. 2. We ran the system of three different types of instruments 3. We ran the method with 3 different operators making the mobile phase Page 7

The Open Lab 2.1 data acquisition Just drop an MS- Excel file into your sequence screen Ease of use from ALS systems including workbench

HPLC Conditions for short method (5 minutes) Agilent 1290 Infinity II UHPLC series Quaternary Pump, Multisampler with wash, Multi Column Themostat, DAD Column: Zorbax Bonus RP 2.1 x 50 mm, 1.8 µm or Poroshell 3.0 x50 2.7um Column temperature: 50 C Injection volume: 0.05 µl Autosampler temp: 23 ºC Needle wash: 3.5 s Flush Port (25:25:50) (H 2 O:IPA:MeOH) DAD-UV 254 nm Mobile phase: A = Water Binary pump - A is buffer B= Methanol C= 0.1% CH 2 O 2 + 2.2 ml 5M NH₄formate in H 2 O Flow rate: 0.5 ml/min Gradient: Time (min) %B %C 0.0 72 5 6.25 95 5 Stop time: 5.00 min. Post time: 1.0 min. Overall run time 6.0 minutes (incl. re-equilibration)

Chemical Structures of Top 10 Cannabinoids CBC THC CBG CBD CBGA THCV CBDA CBDV http://herb.co/2016/02/06/top-10-cannabinoids/ CBN THCA 10

10 cannabinoids under 5 minutes with 1.86 Resolution between the critical pair

Carryover Carry over with the Infinity II vial sampler 1300 Bar addition (G7129A) with needle wash. Blanks after a 10 ul injection of 1 mg/ml standard. Note the chromatography will a 10 ul injection at that concentration saturates the column 12

A single click adds a peak to the calibration and assigns a compound name 13

Assigning compounds for calibration and create reference spectra 14

10 cannabinoids under 5 minutes @ 230 nm HDR really helps

Diode Array Quant Data 16

17

Lower end of CBG calibration curve: 1 9 ng/ml 18

Custom Reporting Custom reporting is wizard based. It allows you to use all your existing IR reports. It allow a simple answer with chromatographic calculations with Pass/Fail color flags

Added Flavor Component 20

Overview of all the samples 21

CBD results in commercially available hemp oil products (names masked) Sample Identifier Average Concentration (mg/ml) Standard Deviation Standard Error 99% CI SIA-1 508.1 9.8 4.9 479.5, 536.7 SIA-2 460.7 14.7 7.4 417.8, 503.6 SIB Not detected N/A N/A N/A SIC 2.3 0.17 0.085 1.7, 2.9 SID 9.3 0.86 0.43 6.8, 11.8 SIE 11.6 0.85 0.43 9.1, 14.1 SIF 12.3 0.78 0.39 9.9, 14.5 SIA-1 and SIA-2: Same manufacturer SIB: Non CBD product SIC: Filtered product about 1/3 of labeled concentration SID: 15% higher than labeled concentration SIE and SIF: 50% higher than labeled concentration * Calibrators and samples were note matrix matched 22

Optional detectors and what they add High Dynamic Range (HDR) 1260 Infinity II DAD-HS 1260 Infinity II DAD-WR 23

24

High Dynamic Range Diode Array 25

UV Spectrum and Chromatogram 26

The addition of spectra and multiple signals CBDV THCV CBD CBG CBN 254 280 230 220 9 -THC CBDA CBC CBGA 9 -TCHA

This is an example of the HDR chromatograms. Note the Y axis is mau/cm typically Y axis are mau/ mm 28

HDR Chromatogram Output # Time Area Height Width Area% Symmetry 1 5.819 133.2 31 0.0611 2.802 0.872 2 6.375 150.5 46.3 0.0484 3.167 0.705 3 6.51 252.8 69.8 0.0538 5.319 0.658 4 7.27 78.2 15 0.0724 1.645 0.45 5 9.069 59.6 12 0.071 1.254 0.5 6 10.003 2954.8 752.1 0.0583 62.157 0.768 7 10.731 937.9 247 0.0563 19.73 0.755 8 11.575 64.3 15.7 0.0593 1.353 0.911 9 12.878 122.3 34.3 0.0547 2.574 0.721 Product peaks are no longer off scale and impurity peaks are quantifiable

Adding Mass Spectrometry Time of Flight Gives ions a kick and measures their speed Tandem Mass Spectroscopy (MS-MS) Selects a range of masses Fragments by collision Analyzes the fragments IONS Quadrupole Passes only ions with the correct mass QTOF QQQ IONS

MSD Spectrum of Peaks Bonus RP column 8 -THC 31

Roy Turton Adele Blackler This is QQQ data with the Agilent G6470 using Acetonitrile as a mobile phase. They used a 2.1 x 100 poroshell Bonus RP Can do potency and pesticides on same system (different columns) D8 will separate 32

Check out www.agilent.com for more information, applications, videos, etc. 33

34