ICP-MS 基本原理. 陳麗真 Jennifer Chen Inorganic Products Specialist

Similar documents
The Periodic Table. Periodic Properties. Can you explain this graph? Valence Electrons. Valence Electrons. Paramagnetism

Nucleus. Electron Cloud

Atoms and the Periodic Table

Last 4 Digits of USC ID:

PERIODIC TABLE OF THE ELEMENTS

5 questions, 3 points each, 15 points total possible. 26 Fe Cu Ni Co Pd Ag Ru 101.

Radiometric Dating (tap anywhere)

Element Cube Project (x2)

(C) Pavel Sedach and Prep101 1

Solutions and Ions. Pure Substances

Guide to the Extended Step-Pyramid Periodic Table

Made the FIRST periodic table

The Periodic Table of Elements

Chapter 12 The Atom & Periodic Table- part 2

Chemistry 431 Practice Final Exam Fall Hours

CHEM 10113, Quiz 5 October 26, 2011

Ch. 9 NOTES ~ Chemical Bonding NOTE: Vocabulary terms are in boldface and underlined. Supporting details are in italics.

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 4: Matter and materials 1

Chem Exam 1. September 26, Dr. Susan E. Bates. Name 9:00 OR 10:00

(please print) (1) (18) H IIA IIIA IVA VA VIA VIIA He (2) (13) (14) (15) (16) (17)

OES - Optical Emission Spectrometer 2000

Laser Spectroscopy on Bunched Radioactive Ion Beams

Chemistry 1 First Lecture Exam Fall Abbasi Khajo Levine Mathias Mathias/Ortiz Metlitsky Rahi Sanchez-Delgado Vasserman

The Periodic Table of the Elements

9/20/2017. Elements are Pure Substances that cannot be broken down into simpler substances by chemical change (contain Only One Type of Atom)

If anything confuses you or is not clear, raise your hand and ask!

Using the Periodic Table

CHM 101 PRACTICE TEST 1 Page 1 of 4

1 Genesis 1:1. Chapter 10 Matter. Lesson. Genesis 1:1 In the beginning God created the heavens and the earth. (NKJV)

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

HANDOUT SET GENERAL CHEMISTRY II

Circle the letters only. NO ANSWERS in the Columns!

NAME: FIRST EXAMINATION

1 of 5 14/10/ :21

610B Final Exam Cover Page

Part 2. Multiple choice (use answer card). 90 pts. total. 3 pts. each.

CHEM 130 Exp. 8: Molecular Models

02/05/09 Last 4 Digits of USC ID: Dr. Jessica Parr

BROOKLYN COLLEGE Department of Chemistry. Chemistry 1 Second Lecture Exam Nov. 27, Name Page 1 of 5

Essential Chemistry for Biology

Atomic Structure & Interatomic Bonding

Instructions. 1. Do not open the exam until you are told to start.

INSTRUCTIONS: CHEM Exam I. September 13, 1994 Lab Section


CHEM 107 (Spring-2005) Exam 3 (100 pts)

Metallurgical Chemistry. An Audio Course for Students

MANY ELECTRON ATOMS Chapter 15

Modified from: Larry Scheffler Lincoln High School IB Chemistry 1-2.1

Chem GENERAL CHEMISTRY I MIDTERM EXAMINATION

The exam must be written in ink. No calculators of any sort allowed. You have 2 hours to complete the exam. Periodic table 7 0

PHYSICAL SCIENCES GRADE : 10

CHEM Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

8. Relax and do well.

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Speed of light c = m/s. x n e a x d x = 1. 2 n+1 a n π a. He Li Ne Na Ar K Ni 58.

CHEM 10123/10125, Exam 2

K. 27 Co. 28 Ni. 29 Cu Rb. 46 Pd. 45 Rh. 47 Ag Cs Ir. 78 Pt.

PART CHAPTER2. Atomic Bonding

CMSC 313 Lecture 17 Postulates & Theorems of Boolean Algebra Semiconductors CMOS Logic Gates

CHEM 167 FINAL EXAM MONDAY, MAY 2 9:45 11:45 A.M GILMAN HALL

8. Relax and do well.

PART 1 Introduction to Theory of Solids

Chemistry 2 Exam Roane State Academic Festival. Name (print neatly) School

HANDOUT SET GENERAL CHEMISTRY I

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

What is the periodic table?

8. Relax and do well.

single-layer transition metal dichalcogenides MC2

INSTRUCTIONS: Exam III. November 10, 1999 Lab Section

Marks for each question are as indicated in [] brackets.

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start. Page # Points possible Points awarded

Fall 2011 CHEM Test 4, Form A

Atomic Emission Spectra. and. Flame Tests. Burlingame High School Chemistry

From Quantum to Matter 2005

CHEM 172 EXAMINATION 1. January 15, 2009

POLYTECHNIC OF NAMIBIA

8. Relax and do well.

Why all the repeating Why all the repeating Why all the repeating Why all the repeating

PHYSICAL SCIENCES MARCH CONTROLLED TEST GRADE

INTRODUCTION TO MEASUREMENTS

DO NOW: Retrieve your projects. We will be reviewing them again today. Textbook pg 23, answer questions 1-3. Use the section 1.2 to help you.

7. Relax and do well.

M10/4/CHEMI/SPM/ENG/TZ2/XX+ CHEMISTRY. Wednesday 12 May 2010 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1. Analytical Chemistry CMY 283. Time: 120 min Marks: 100 Pages: 6

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Secondary Support Pack. be introduced to some of the different elements within the periodic table;

Chemistry Standard level Paper 1

8. Relax and do well.

Circle the letters only. NO ANSWERS in the Columns! (3 points each)

CHEM 107 (Spring-2004) Exam 2 (100 pts)

CHEM 171 EXAMINATION 1. October 9, Dr. Kimberly M. Broekemeier. NAME: Key

B. X : in phase; Y: out of phase C. X : out of phase; Y: in phase D. X : out of phase; Y: out of phase

M11/4/CHEMI/SPM/ENG/TZ2/XX CHEMISTRY STANDARD LEVEL PAPER 1. Monday 9 May 2011 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

Chapter 3: Stoichiometry

Instructions. 1. Do not open the exam until you are told to start.

M09/4/CHEMI/SPM/ENG/TZ1/XX+ CHEMISTRY. Monday 18 May 2009 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

30 Zn(s) 45 Rh. Pd(s) Ag(s) Cd(s) In(s) Sn(s) white. 77 Ir. Pt(s) Au. Hg(l) Tl. 109 Mt. 111 Uuu. 112 Uub. 110 Uun. 65 Tb. 62 Sm. 64 Gd. 63 Eu.

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Transcription:

ICP-MS 基本原理 陳麗真 Jennifer Chen Inorganic Products Specialist Email:Jennifer.Chen@perkinelmer.com

What is the ICP-MS Inductively Coupled Plasma Mass Spectrometry can analyze almost all elements in the periodic table at concentration of 1 ppm = 1 mg/l = 1 μg/ml = 10-6 g/ml 1 ppb = 1 μg/l = 1 ng/ml = 10-9 g/ml 1 ppt = 1 ng/l = 1 pg/ml = 10-12 g/ml 1 ppq = 1 pg/l = 1 fg/ml = 10-15 g/ml Other similar techniques: Atomic Absorption Spectroscopy (AAS) Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES)

Atom He Atomic number = 2 Atomic weight = 4.002602 g Electron cloud Proton 1,840 electrons - - -- --- - + - - - - - - - - -- - Electron - Nucleus + + Proton - Neutron Proton + Neutron

Isotope and Isobar Fe Atomic number = 26 Atomic weight = 55.845 g Ni Atomic number = 28 Atomic weight = 58.6934 g Isotopes Abundance(%) Protons Neutrons Electrons 54 Fe 5.845 26 28 26 56 Fe 91.754 26 30 26 57 Fe 2.119 26 31 26 58 Fe 0.282 26 32 26 58 Ni 68.0769 28 30 28 60 Ni 26.2231 28 32 28 61 Ni 1.1399 28 33 28 62 Ni 3.6345 28 34 28 64 Ni 0.9256 28 36 28

ICP-MS Spectrum 1 ppb Pb Photocurrent (Amperes) -5 10-6 10-7 10-8 10-9 10 1 Pb 100mg/L Pb isotopes 4 7 8 9 5 6 3 2 10 11 12 190 210 230 250 270 290 310 330 350 Wavelength (nm)

Elements Analyzed by ICP-MS - D.L. of ELAN DRC - 1A 2A 3B 4B 5B 6B 7B 8B 8B 8B 1B 2B 3A 4A 5A 6A 7A 8A H Inductively Coupled Plasma Mass Spectrometry Li Be B C N O F Ne Na Mg Al Si P S Cl Ar K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe Cs Ba La Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn He Fr Ra Ac Lanthanoid Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu Actinoid Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr D.L. range < 1 ppt 1 100 ppt 0.1 1 ppb Other similar techniques: Atomic Absorption Spectroscopy (AAS) Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES)

ELAN Product History ELAN Series Page 7

Schematic Diagram of ICP-MS : ELAN 9000 Main Q-pole DC + AC ( U + Vcosωt ) ShadowStop + + + + + + + Detector Ar gas in Pre-filter AC only ( Vcosωt ) E-Lens Turbomolecular pumps Roughing pumps

Schematic Diagram of ELAN DRC Main Q-pole DC + AC ( U + Vcosωt ) DRC DC + AC ( U + Vcosωt ) Vent valve Gas inlet Shadow Stop + + + + + + Detector Ar gas in Pre-filter AC only ( Vcosωt ) Turbomolecular pumps Roughing pumps E-Lens Axial Field Gradient DC

ELAN ICP-MS System 主要結構 Sample Introduction System Ionization Source Ion Extraction System Ion Focusing System Mass Filter Ion Detection System Control Software Page 10

Components of the ELAN 9000 Mass Filter Plasma Spectrometer Interface Ion Lens ICP Torch Spray Chamber Electron Multiplier Sample Argon Turbo Pump Mech. Pump Mech Pump RF Supply ICP-MS Computer and Control Electronics Page 11

Elan 9000 Major Subsystems Interface Region Mass Filter and Ion Optics Area Sample Introduction System ICP Power Supply (RF Generator) Vacuum Pump System Page 12

ICP-MS -sample introduction Mass spectrometer ICP Detector Interface Sample........... Page 13

Pneumatic Nebulizers Concentric nebulizer Cross flow nebulizer Sample Sample Ar nebulizer gas Ar nebulizer gas

Cross-Flow Nebulizer Standard for ELAN DRCe Uptake 0.5-1.5 ml/min. Good general purpose HF resistant Inexpensive Resistant to clogging Page 15

Sample Introduction Device To generate sample droplets by nebulization and to introduce only fine droplets in the plasma. Sample solution Nebulizer To ICP Ar carrier gas

Sample Introduction Device ( Cyclon spray chamber ) Nebulizer generates small droplets. Spray chamber eliminates larger droplets and introduces only fine droplets into ICP. To ICP Nebulizer To drain

Droplet Size Distribution and Effect of Spray Chamber (%) 50 40 30 20 10 No Spray Cham be r (%) 30 25 20 15 10 5 with Spray Ch a m b e r 0 8 142026323844505662687480 Particle Size ( um ) 0 2 3 4 5 6 7 8 9 10 11 Particle Size ( um)

PFA Sample Introduction System

Plasma Torch, Injector, and Load Coil Assembly Check concentricity of torch and RF coil Use torch alignment tool Tool should move freely Check Sampling Depth Check torch for deposits and discoloration Soak in acid to clean Check for thermal deformation Replace as necessary Check injector and adapter Page 20

Plasma RF 40.68 True Power Control feedback system to control output power provides excellent stability

Ionization Efficiency of Elements in Ar Plasma - Saha equation - a 1 - a = ( 2 p mk T ) Neh 3 3 2 2 Z + Z e V k T a : Ionization efficiency Ne: Electron density m : Mass of an ion V : Ionization potential of an element k : Boltzman constant T : Electron temperature h : Plank constant Z : Partition function

Ionization Efficiency of Elements in Ar Plasma Ionisation efficiency (%) 100 80 60 40 20 0 Li Be B Ru Na Al K ScVMnCo Ga Rb Y Nb Pd In Cs Lanthanoides Hf Tl Pb Ra Mg Si P S Ca Ti Cr Cu Fe Ge Ni Zn As Se C O Ne Cl Ar Br Xe Sr Sn Zr Tc Ba Ta Mo RhAg W Cd Sb Te I 0 He 10 20 30 40 50 60 70 80 90 N F Kr Electron temperature : 6,680K Atomic number Re Bi Po Ac Os Pt Au Rn Hg Ir Electron density : 1.47 14 x 10 cm -1

Ionization efficiency of elements in Ar plasma 100 10 Inonizatoin Efficiency (%) 1 0.1 0.01 0.001 0.0001 0.00001 0.000001 Li Be Mg Cl Ar Fe As 0.0000001 4,500 5,000 5,500 6,000 6,500 7,000 7,500 Electron Temperature (K) Electron density: 5 x 10 13

ELAN DRC Plasma Magnetic field Auxiliary gas Nebulizer gas + sample droplets Plasma Eddy current Plasma gas RF coil

Plasma Ionisation Source To desolvate, decompose, atomise and ionise fine sample droplets. Auxiliary gas Carrier gas + Sample Auxiliary gas Plasma gas Wok coil Magnetic field

電漿形成過程

Ionization Process in Plasma Aerosol Particles Molecule Atom Ion Ca(OH) 2 Ca Ca + Nebulization Desolvation Vaporization Dissociation Ionization

Ion Distribution in Plasma Relative Ion intensity (%) 100 80 60 40 20 Ca Ar 0-8 -6-4 -2 0 2 4 6 8 Distance from the torch center

ELAN RF Generator Fully computer-controlled and autotuned 40-MHz free-running generator handles widely varying sample matrices, including organics PlasmaLok grounding system to ensure seamless analysis of wide range of sample types

First Ionization Potential of Elements (ev) 25 He Ne He 24.58eV 20 Ionisation potential 15 10 5 F N O C Be B Li Ar Kr Xe Cl Br P I Fe Zn As Ir Mg S Mn Co Se Mo Ru Cd Pd Sb Os Ti Si Ca Ge Y Zr Te Ta Lanthanoides Pt Cu Ag W Cr Ni Nb Rh Sn Hf Al Sc Ga Re Sr Tc In Na Ba K V Rb Cs Au Hg Po Pb Tl Bi Rn Ra Ac Ar 15.75eV 8 ev 0 0 10 20 30 40 50 60 70 80 90 Atomic number

Sampling ions through interfaces Sampling cone Direction of ions and neutral species gathers by expansion of plasma through sampling cone. Mach disk Shadow stop Na + e- Ar Ar Na + e- Ar Na + e- e- e- Ar Ar Na + Ar e- Na + e- e- e- e- e - Na + Ar Na + Ions and neutral species and elencrons are randamly moving in the plasma Vacuum Skimmer cone AutoLens

ELAN DRCe Interface New quick-change sampler and skimmer cones Ni is standard. Large diameter orifices to minimize clogging Sampler - 1.1 mm Skimmer - 0.9 mm Rugged design for excellent stability with real-world samples skimmer cone sampler cone

Page 34 Rinse well with de-ionized water DRY THOROUGHLY Reinstall or replace O-rings and reinstall the cones

Ion Extraction to Vacuum Skimmer cone Sampling cone Mach disk Na + Na + Na + Na + + -e Na Ar -e -e + Ar -e + Na Na Ar Ar -e -e - + e Na Ar + Ar Na -e -e Ar + Na -e -e AutoLens ShadowStop Mach disk Plasma Vacuum Vasuum

Elan Series Ion Extraction Process Differential aperture Photon Stop Quadrupole assembly Cylinder lens Skimmer Sampler Page 36

ELAN New Single Ion Lens System New SwiftMount single ion lens with shadow stop Quick-change demountable design Allows removal and replacement of ion lens in less than 3 minutes Reproducible and precise re-positioning of ion lens ever time Shadow Stop

Elan Series Ion Beam Focusing Aperture Cylinder Lens (Net + Charge on Lens) Skimmer Page 38

ELAN DRC AutoLens 1.2 Normalized Signal 1 0.8 0.6 0.4 Li Co Y In Pb U 0.2 1 3 5 7 9 Lens Voltage (V)

Dependence of Optimum Lens Voltage on Analyte Mass 9 8 7 Optimum Lens 6 Voltage 5 4 3 0 50 100 150 200 250 300 Mass, amu Page 40

ELAN DRC Quadrupole Mass Filter Binary gold metallized ceramic rods for hyperbolic quadrupole field. Proven rock-solid mass calibration stability. Rapid scanning characteristics. On-the-fly custom resolution.

Principle of Q-pole Mass Filter + Vcos ωt + + U 2ro Remove lighter mass PB + ( U + Vcos ω t ) PB - ( U + Vcosω t ) -U + Remove heavy mass -Vcosωt

Scanning and Measurement Protocol Sc : scan Stn : settle time Dwn : dwell time low amu high Integration time : Sc x ( Dw1 + Dw2 + +Dwn ) Measurement time : Sc x ((St1 + Dw1 ) + (St2 + Dw2 ) + + (Stn + Dwn ))

ELAN DRC Dual-Stage Discrete Dynode Detector with SimulScan TM

Electron Multiplier Detector To convert ions to electrical signal and detect a number of ions. Amp M + e - e - M + Electron Dynode surface High voltage of EM

Principle of Dual Mode Detector Pulse mode is used for lower concentration. Analog mode is used for higher concentration. Gate closes when signals are too high. Low conc. Amp Discriminator Counter Pulse counting High conc. Gate Amp V/F converter P/A factor Analog counting

ELAN Improvements All new ELANs will have 1 cassette torch mount 3 2 1 One hand removal and replacement 2 3 New lens mount No tools required detector electronics 4 4 Quick release oil drain valves

New cassette torch mount Designed for one hand removal from the instrument Shortcut to install.lnk Ratcheting thumbscrews

New cassette torch mount Unitized design that 1 works with current torch and injectors Automatically makes/breaks gas and electrical connections 2 3 4 Push-on torch gas 3 connectors with o-ringso Ratcheting thumbscrews (like a car gas cap) ensure 4 constant correct torque 2 1 Hybrid between the Optima and current designs

New oil drain valve Quick release valve lever Requires no tools Removable drain hose Kit W101-1013 1013 converts both pumps

ELAN DRC Vacuum System Triple-stage, turbo vacuum system for optimum pumping Roughing pump (25 m 3 /hr) for interface region. Turbo molecular pump (220 L/sec) for Q-pole mass filter chamber. Roughing pump 10 m 3 /hr to back-up turbo molecular pumps.

ELAN DRC Single Ion Lens System SwiftMount single ion lens with shadow stop Quick-change demountable design Allows removal and replacement of ion lens in less than 3 minutes Reproducible and precise repositioning of ion lens ever time Shadow Stop AutoLens

Snap out and Snap in New lens mount Elan photos.exe New Shadow stop sits on posts. Two fingers to remove and replace lens mount. Retrofittable onto existing instruments.