Metso Concentration Measurement 3300

Similar documents
Electromagnetic Flowmeter

ISEmax CAM40/CAS40. Technical Information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Deionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Conductivity sensor for hygienic applications

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Concise laboratory catalogue

Automatic titrators, TitroMatic

ph / Temperature Meter for Cheese with Application Specific Probe

Differential ph Probe Type 18

473 Dew Point Hygrometer

Industrial Resistance Thermometers according to DIN Model MWD

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF CHEMICALLY AGGRESSIVE LIQUIDS PROCESS REFRACTOMETER PR-23-W/PR-23-M SB:PR-23-W/M

473 Dew Point Hygrometer

PAA-ANALYZERS PRINCIPLE OF OPERATION

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

473-SHX Dew Point Mirror

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

One-hand ph/temperature measuring instrument

ADI 2040 Process Analyzer

Pressure transmitters for industrial applications MBS 32 and MBS 33

Thermometers. Applications

TOP Offers Special Measuring Instruments

Field IT 50T Series Transmitters

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Application Your benefits

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Pressure Measurement Single-range transmitters for general applications

Thermal Mass Flow Meter for Gases

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

5SJ4...-.HG Circuit Breakers to IEC and UL 489

ISEmax CAS40D. Technical Information

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

AC axial compact fan

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Technical specification FLUXUS F502TE

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

Chemistry Instrumental Analysis Lecture 23. Chem 4631

Advanced concentration measurement of sulfuric acid. Alexandra Prokoph M.Sc. SensoTech GmbH Sulphur Conference, 7-10 November 2016, London, U.K.

HANDHELD GAS ANALYZER DELTA 65

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Edgetech Instruments Inc.

OEM ph Competences. Solutions for ph OEM Applications in Liquid Analysis

Reflex-Radar BM 100 A

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Stage 4 G-03: CONDUCTIVITY OF SOLUTIONS CP: USP. May 2015 INTRODUCTION

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Air velocity & IAQ measuring instruments

INNOVATION IN MAGNETICS DS0003/18. Mag-01H. Single Axis Fluxgate Magnetometer.

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

P S H - S 3G m t e e t r e (C ( E mar ar e k d e ) P B H - B 4 - Por or ab ab e l PH M t e e t r

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

SANMUR CONTROLS PVT. LTD.

Perfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors

Information Technology Solutions Neptune Datasheet

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

ED 701 General Industry Pressure Transmitter

Compact ph Measuring Instruments With Pro Engineering

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Operating Instructions for Digital Manometer. Model: MAN-SD

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

water proof water proof Tap water, pure water application Precious, trace amount sample 3-in-1 Plastic Electrode D

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Capacitive Sensors. Contents

SVH with HYDROVAR (HVL range)

Direct-operated 2/2-way compact solenoid valves Type EV210A

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Amir Hossein Parvardi 1

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

UV3000. Accurate, precise, and portable ambient gas point analyzer

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

Fitting PS P - B - R2

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Air velocity & IAQ measuring instruments

FXP DATASHEET JUNHO 2013

Transcription:

Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of strong acid or lye. It calculates the concentration of the process liquor based on 4-electrode conductivity measurement combined with temperature measurement. The Concentration Measurement has selectable pre-programmed recipes and is ready for use upon installation. HCl SO 3 NaCl H 2 NaOH HF ppm Designed for industrial environments Unique corrosion resistant sensors Easy to use 22 pre-programmed recipes for strong acid/lye Display of concentration and temperature Easy sensor installation for all pipe sizes No maintenance HNO 3 SO 2 Long life time H 3 PO 4 P 2

Metso Concentration Measurement Concentration determination The Concentration Measurement is provided with selectable recipes for the range specifications listed next page. The recipes calculate the concentration from the relationship of conductivity versus concentration and temperature. The sensors In-line 4-electrode conductivity sensors with Pt1000 temperature element. Corrosion-resistant materials available: PTFE and platinum (HF and SO 3 ) PTFE and tantalum (strong acids) PTFE and AISI 316 steel (lye) A one-point or two-point calibration facility is available to eliminate the effect on the conductivity-concentration relationship from any foreign chemicals contained in the liquor. However under normal circumstances calibration before use is not needed. The analogue output can be set up to display expanded range. 4-electrode sensor with external electrodes 4-electrode sensor with internal electrodes The sensors perform measurements of high accuracy and require minimum maintenance due to integrated automatic scaling compensation. For measurement in pure liquids, sensors with internal electrodes and a small measuring volume (60 ml) are available. For slurry liquids, sensors with external electrodes are available in a hydrodynamic self-cleaning construction, measuring within a volume corresponding to a radius of 75 mm (3 inches). Conductivity of NaOH at various temperatures. Concentration measurement cannot be used in the shadow area. The sensors are easy to install due to the wide selection of adaptors. The cable connection parts of the sensors are made of AISI 316 steel in a rugged and watertight construction (IP67).

Sensors examples for strong acid measurements Flow-through sensor type with internal electrodes, for mounting in narrow pipes Conductivity/Concentration/Temperature The Concentration Measurement measures the conductivity as well as the temperature and calculates the correct temperature compensation factor. Sensor with external electrodes, suitable for slurry liquids. The Concentration Measurement directly converts those data to actual concentration, which will be displayed in g/l or %, and which is available as output for PLC or DCS display as well. Beyond the pre-programmed 22 standard recipes, other recipes for your specific solutions may be available. The portable version The Portable Conductivity Measurement is microprocessor based, with rechargeable battery, using the 4-electrode principle and is designed for conductivity measurement ranging from ultrapure water to concentrated acids, bases, and pulp liquors. Designed for use in the fields as well as laboratories Data-logger available Reference for certification of field instruments Sturdy carrying case Using same parts as in the standard industrial analyzer

Standard recipes Recipe (GOS) Measuring Electrode No. Solution range Temperature Typical accuracy material 196.03 HCl 0-15 % 10-80 C 0-15 % ± 0.3 HCl 194.59/2 HCl 25-40 % 0-60 C 25-40 % ± 0.5 HCl 194.60 HCl 30-36 % 15-45 C 30-36 % ± 0.2 % HCl 194.56 HF 99.7-100 % 0-50 C Pt 196.62 HNO 3 0-20 % 0-90 C 5-20 % ± 0.8 HNO 3 194.51/3 HNO 3 50-75 % 0-65 C 50-65 % ± 0.5 HNO 3 194.70 P 2 O 5 45-60 % 20-80 C 20-80 C ± 0.2 % 196.42 H 2 0-10 % 0-100 C 0-10 % ± 0.3 H 2 196.43/3 H 2 0-20 % 20-40 C Spec. 194.31 H 2 50-80 % 25-60 C 30-60 C ± 1 % H 2 194.28 H 2 72-82 % 20-70 C 72-80 % ± 0.5 % H 2 194.10 H 2 92-100 % 20-70 C 30-70 C ± 0.35 % H 2 194.06 H 2 93-100 % 20-110 C 94-100 % ± 0.15 % H 2 196.59 H 2 0-230 g/l 0-100 C 194.25 SO 3 (oleum) 18-34 % 20-80 C 18-34 % ± 0.5 % SO 3 Pt 194.26 SO 3 (oleum) 55-70 % 25-80 C 60-70 % ± 0.5 % SO 3 Pt 196.58 NaOH 0-10 % 0-100 C 5-100 C ± 0.17 % NaOH 316 194.61 NaOH 20-40 % 20-50 C 25-40 C ± 0.7 % NaOH 316 194.62 NaOH 45-55 % 40-75 C 45-55 % ± 0.7 % NaOH *316 196.56 NaCl 0-10 % -5+100 C 316 196.60 SO 2 0-25 g/l 0-50 C 0-20 g/l ± 1.3 g/l SO 2 316 194.56/2 H2o in HF 0-3000ppm 0-50 C Pt Many other recipes are possible. Contact us about your specific requirements. * NaOH above 50 % 60 C: Use electrodes Metso Automation Inc. 12/2010 B183 003.0-EN For more information, contact your local automation expert at Metso. www.metso.com/conductivity The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice.

Metso Concentration Measurement 3300 Specifications Concentration ranges: 22 preprogrammed recipes Conductivity ranges: 20 μs/cm to 2000 ms/cm Temperature compensated for: STD salt, weak lye, acids, and OFF Output: Two current outputs 4-20 ma for concentration, conductivity or temperature Temperature measurement: 40 to +250 C Display: LCD Sensor connection: Series 4000 sensors with 11-pole strip connector and MF20 cable adaptor Dimensions in mm Local or remote measuring range selection: Two concentration and two conductivity set-up modes. Control voltage: 12 30 V DC Mounting options HART communication is available Wall Panel Enclosure Material: Cast aluminium, PE coated Protection: IP67 Dimensions: 144 x 144 x 107 mm Mounting: Panel, wall or pipe Ambient temp.: From -10 to + 60 C Storage temp.: From 20 to + 70 C Weight: 2.3 kg Metso Automation Inc. 12/2010 B183 003.0-EN Wall mounting Type 3307 Type 3317 Panel mounting Type 3308 Type 3318 Power supply Loop powered Line powered 16 30 V DC 85 265 V AC, on ma1 6 VA Alarm No alarm Two relays 250 V AC, 8 A Display Non-Illuminated illuminated For more information, contact your local automation expert at Metso. www.metso.com/conductivity The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. Pipe Pipe mounting kits Type For pipe No. dimension 4902 a 25-38 mm b 35-52 mm c 50-73 mm d 72-94 mm e 82-114 mm

World wide support for Metso Concentration Measurements Go to www.metso.com/conductivity to find your local expert Metso Automation Inc. 12/2010 B183 003.0-EN For more information, contact your local automation expert at Metso. www.metso.com/conductivity The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice.