A Sensitive Chemiluminescence Method for Determination of Hydroquinone and Catechol

Similar documents
ISSN X CODEN (USA): PCHHAX. Determination of captopril with potassium permanganate chemiluminescence system*

Cu-Creatinine- Metol system

Study on the interaction behavior of catalase with. cephalosporins by chemiluminescence with flow injection

Reverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water. Jintana Klamtet

Chemiluminescence Emission Reaction of Aldehyde with Hydrogen Peroxide and Luminol

A Fluorescence Turn-On Sensor for the Detection of Palladium Ions that Operates Through In-Situ Generation of Palladium Nanoparticles

SIMULTANEOUS DETERMINATION OF PROCAINE AND BENZOIC ACID BY DERIVATIVE SPECTROMETRY

mediated chemiluminescence for hydrogen peroxide and glucose

Orderly Arranged Fluorescence Dyes as a Highly Efficient Chemiluminescence Resonance Energy Transfer Probe for Peroxynitrite

*Author for Correspondence

Supporting Information

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Supplementary Material

Supporting Information. for A Water-Soluble Switching on Fluorescent Chemosensor of. Selectivity to Cd 2+

Flow injection chemiluminescence determination of epinephrine using epinephrine-imprinted polymer as recognition material

DETERMINATION OF SERUM ALBUMIN WITH TRIBROMOARSENAZO BY SPECTROPHOTOMETRY

DEVELOPMENT AND OPTIMIZATION OF THE UV REDUCER FOR THE DETERMINATION OF EXPLOSIVES

UV Spectrophotometric Estimation of Levoceterizine Dihydrochloride in Bulk and Dosage Form

Supporting Information. Selective detection of trace amount of Cu 2+ using semiconductor nanoparticles in photoelectrochemical analysis

Iron Catalyzed Chlorpromazine-Hydrogen

462 1 & (2&3 ( 4 5 6" 6 7 ' ("0 / L1 1 % FG &

Supplementary Material

A LAZAR LABORATORY HANDBOOK MEASUREMENT OF NITRIC OXIDE IN BIOLOGICAL SAMPLES

Yujuan Zhou, Kecheng Jie and Feihe Huang*

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Supporting Information

A colorimetric and fluorescent turn-on sensor for pyrophosphate. anion based on dicyanomethylene-4h-chromene framework

Characterization of keto-enol tautomerism of p-hydroxyphenylpyruvic acid using CE with amperometric detection and spectrometric analysis

Supporting Information

DETERMINATION OF ESTRADIOL VALERATE IN PHARMACEUTICAL PREPARATIONS BY ZERO - AND FIRST-ORDER DERIVATIVE SPECTROPHOTOMETRIC METHODS

Full-Color Light-Emitting Carbon Dots with a Surface-State

Supporting information. One-step facile synthesis of novel β-amino alcohol functionalized

Journal of the Chinese Chemical Society, 2007, 54,

Fluorescent Chemosensor for Selective Detection of Ag + in an. Aqueous Medium

Spectrophotometric Determination of Hemoglobin with Lanthanum(III)-(DBC-Arsenazo)

Electronic Supporting Information. for

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 8(2),

Spectrophotometric Determination of Lorsartan Potassium and its Dosage Form by Bromothymol Blue and Phosphate Buffer

High Pressure/Performance Liquid Chromatography (HPLC)

CHAPTER 6 SUMMARY & CONCLUSION. pollution. It was known that many analytical methods that are available for the

Energy transfer process in the reaction system NH 2 OH-NaOH-Cu(II)-Eu(III)/thenoyltrifluoroacetone

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Supplementary Information

HI. IN A CONFLUENCE CONFIGURATION +

Supporting Information. An AIE active Y-shaped diimidazolylbenzene: aggregation and

Natural montmorillonite nanosheet colloid-catalyzed hydrogen peroxide

Supporting Information

BINDING INTERACTION BETWEEN CHONDROITIN SULFATE AND METHYLENE BLUE BY SPECTROPHOTOMETRY

Electronic Supplementary Information for. A Redox-Nucleophilic Dual-Reactable Probe for Highly Selective

A novel Ag 3 AsO 4 visible-light-responsive photocatalyst: facile synthesis and exceptional photocatalytic performance

Journal of Chemical and Pharmaceutical Research, 2014, 6(5): Research Article

GB/T Translated English of Chinese Standard: GB/T

Highly Sensitive and Selective Colorimetric Visualization of Streptomycin in Raw Milk Using Au Nanoparticles Supramolecular Assembly

Preparation and adsorption properties of cyclodextrin modified chitosan inclusion compound crosslinked by glutaraldehyde

A dual-model and on off fluorescent Al 3+ /Cu 2+ - chemosensor and the detection of F /Al 3+ with in situ prepared Al 3+ /Cu 2+ complex

of nm throughout the experimental work.

A Novel Detection Technique of Hydrazine Hydrate: Modality Change of Hydrogen-Bonding Induced Rapid and Ultrasensitive Colorimetric Assay

All Questions are to be attempted 1- Redox Titration (35 Marks)

Cyclic Voltametric Studies on the Interaction of Adrenaline With Formic Acid and Acetic Acid

Standard Methods for the Examination of Water and Wastewater

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Electrogenerated Upconverted Emission from Doped Organic Nanowires

Department of Chemistry of The College of Staten Island and The Graduate Center, The City University of

Supplementary Material (ESI) for Journal of Analytical Atomic Spectrometry This journal is The Royal Society of Chemistry 2010

Annex 2 Formaldehyde

Application of Nano-ZnO on Antistatic Finishing to the Polyester Fabric

Separation of Toxic Metal Cations on Stannous Silicate layers in Micellar TLC

Spectrophotometric determination of sodium dodecylbenzene sulphonate using congo red

Absorption and Rayleigh scattering and resonance Rayleigh scattering spectra of [HgX 2 ] n nanoparticles

Method development and validation for the estimation of metronidazole in tablet dosage form by UV spectroscopy and derivative spectroscopy

Research Article Spectrophotometric Estimation of Didanosine in Bulk Drug and its Formulation

A photo-catalytic reactor for degrading volatile organic compounds (VOCs) in paper mill environment

Fax: ; Phone: E mails: (C. B. Zheng) or (X. M. Jiang)

Electronic Supplementary Information

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

Supporting Information. Bi-functional Catalyst with Enhanced Activity and Cycle Stability for. Rechargeable Lithium Oxygen Batteries

Supporting Information. Cells. Mian Wang, Yanglei Yuan, Hongmei Wang* and Zhaohai Qin*

Phosphorescent chemosensor for Hg 2+ and acetonitrile based on iridium(iii) complex

Cyclic Voltammetric Determinations of Dart (Drug) and Cd(II) Ion in Pharmaceutical Preparations

Direct Electrocatalytic Oxidation of Hydrogen Peroxide Based on Nafion and Microspheres MnO 2 Modified Glass Carbon Electrode

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

A graphene oxide-based AIE biosensor with high selectivity toward bovine serum albumin

Urchin-like Ni-P microstructures: A facile synthesis, properties. and application in the fast removal of heavy-metal ions

Development of a Reversible Fluorescent Gold Sensor with High. Selectivity

NEW SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF DESLORATADINE IN PHARMACEUTICAL FORMULATIONS

Supporting Information. Fluorescence Regulation of Copper Nanoclusters via DNA Template. Manipulation toward Design of a High Signal-to-Noise Ratio

Spectrophotometric Determination of Anionic Surfactants in River Water with Cationic Azo Dye by Solvent Extraction- Flow Injection Analysis

ANALYSIS, CHARACTERIZATION AND ESTIMATION OF ORGANIC COMPOUNDS IN WATERS BY USE OF ULTRAVIOLET ABSORPTION PARAMETERS.

HPLC mg 5 RSD 10%

Specific Determination of Hydrogen Peroxide With A Catalase Biosensor Based on Mercury Thin Film Electrodes

Supporting Information. for

Determination of Iodate by HPLC-UV after On-Line Electrochemical Reduction to Iodide

Cobalt-Porphyrin /Dansyl Piperazine Complex Coated Filter. Paper for Turn on Fluorescence Sensing of Ammonia Gas

UV Spectrophotometric Method Development and Validation of Ezetimibe and Simvastatin in Bulk and Pharmaceutical Dosage Form

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

New Spectrophotometric Multicomponent Estimation of Ciprofloxacin and Tinidazole Tablets

A ratiometric luminescent sensing of Ag + ion via in situ formation of coordination polymers

A Visible Near-Infrared Chemosensor for Mercury Ion

Table 1: Volumes of Components of HRP-AAP Assay Solutions Solution Volume [μl] 4-Iodophenol 10 AAP 700 H 2 O HRP 50

PointH Standard Addition Method for Simultaneous Determination of Zinc (II) and Aluminum (III) Ions

Transcription:

Sensors 2007, 7, 578-588 sensors ISSN 1424-8220 2007 by MDPI www.mdpi.org/sensors Full Research Paper A Sensitive Chemiluminescence Method for Determination of Hydroquinone and Catechol Lijun Zhao 1, Baoqiang Lv 2, Hongyan Yuan 2, Zaide Zhou 1 and Dan Xiao 1,2* 1 College of chemistry, Sichuan University, Chengdu, 610064, P. R. China 2 College of chemical engineering, Sichuan University, Chengdu, 610064, P. R. China * Author to whom correspondence should be addressed; Fax +86 28 85407859; Tel. +86 28 85407958; E-mail: xiaodan@scu.edu.cn Received: 14 March 2007 / Accepted: 19 April 2007 / Published: 26 April 2007 Abstract: A novel flow-injection chemiluminescence(cl)method has been developed for the determination of hydroquinone (HQ) and catechol (CT), based on their inhibition of the chemiluminescence reaction of luminol KMn 4 β-cyclodextrin (β-cd). It was found that β-cyclodextrin could effectively enhance the chemiluminescence produced from the reaction of luminol with KMn 4 in basic media. The proposed method is simple, rapid, convenient and sensitive, has a linear range of 1 20 ng/ml for catechol with a detection limit of 0.4 ng/ml, and 1 10 ng/ml for hydroquinone with a detection limit of 0.1 ng/ml, respectively. The possible mechanism of the CL reaction is also discussed. Keywords: hydroquinone; catechol; chemiluminescence; flow injection analysis; determination 1. Introduction Hydroquinone and catechol are phenolic compounds and are widely used in tanning, cosmetics, the pharmaceutical industry and in developing photo-graphs and thus are important environmental pollutants [1, 2]. It is also well documented that HQ and CT are among the most abundant organic constituents of mainstream tobacco smoke [3-5]. These compounds are harmful to humans and animals even in very low concentration. Therefore, it is very important to develop a highly sensitive and selective analytical method for the determination of hydroquinone and catechol in food, biological and

Sensors 2007, 7 579 environmental monitoring, etc. From the literature, several methods for the determination of hydroquinone and catechol are available, such as spectrophotometry [6,7], high performance liquid chromatography (HPLC) [2,8] and electrochemiluminescence [9] techniques. To explore an alternative method for the determination of hydroquinone and catechol, chemiluminescence coupled with flow injection system is developed. Chemiluminescence (CL) is a high sensitive analytical technique that can be used in the determination of different compounds in various fields. In recent years, it has received much attention, especially with flow injection (FIA),due to its high sensitivity, wide linear range and simple instrumentation [10-17]. And some CL methods have been developed for the detection of hydroquinone and catechol [10,17,18]. He et al. [10] have proposed a CL method based on the enhancing effect of polyhydroxy phenols on the Fe 3+ H 2 2 Rh6G system. Du et al. [17] have developed another method for determination of pyrogallol, phlorglucinol, hydroquinone and resorcinol based on the ferricyanide/ferrocyanide enhanced luminol polyphenol CL. In our work, we found that chemiluminescence generated by the reaction of luminol with KMn 4 in basic media could be significantly enhanced by β-cd. While the enhanced chemiluminescence was strongly inhibited in the presence of hydroquinone and catechol. Based on these observations, a new flow-injection CL method was proposed for the determination of hydroquinone and catechol,with detection limits of 0.1 ng/ml and 0.4 ng/ml, respectively. However, the proposed CL system was not suitable for the determination of dihydroxybenzene isomer-resorcinol. The peak of the CL became distorted irregularly for resorcinol, probably because the resorcinol could not be oxidized by singlet oxygen and hydroxyl radical formed in the reaction to produce corresponding quinone. Moreover, the presence of resorcinol affected the detection of hydroquinone and catechol. The actual effect of resorcinol on the CL reaction is still unknown, further study is being carried out. A possible mechanism of the CL reaction was also discussed. 2. Experimental 2.1. Reagents All the chemicals were of analytical-reagent grade and were used as received. The double-distilled water was used throughout. The 1.0 mg/ml standard solutions of hydroquinone and catechol were freshly prepared by dissolving appropriate amount of each in water. A 0.01 mol/l luminol stock solution was prepared with 100mL of 0.1 mol/l NaH solution. A 0.01 mol/l KMn 4 stock solution was prepared with double-distilled water. β-cyclodextrin (1.0 10 3 mol/l) stock standard solution was prepared by dissolving appropriate amount in 0.04 mol/l NaH solution. These standard solutions were stored in the refrigerator and protected from light. 2.2. Apparatus The flow-injection system used in this work is shown in Fig. 1. Two peristaltic pumps were used to deliver all solutions. PTFE tube (0.8 mm i.d.) was used to connect all components in the flow system. The streams of luminol, KMn 4, β-cyclodextrin and analyte were mixed in a flow cell. The CL signal

Sensors 2007, 7 580 produced in the flow cell was detected with a photomultiplier tube and recorded by an IBMcompatible computer using flow-injection CL analysis system (Xi an Ruike Electronic Equipment Corporation, China). A model F-4500 fluorescence spectrophotometer (Hitachi, Japan) and a model UV-2300 spectrophotometer (Shanghai, China) were also used. Figure 1. Schematic of the flow system for determination of hydroquinone and catechol. a, KMn 4 solution; b, β-cyclodextrin solution; c, sample solution; d, luminol solution; P1 and P2, peristaltic pumps 1 and 2; L2 450 mm length; V, eight-way injection valve; F, flow cell; PMT, photomultiplier tube; HV, high voltage (operated at -600 V); CM, computer; W, waste solution. 2.3. Procedures As shown in Fig. 1, flow lines a d, were inserted into KMn 4 solution, β-cd solution, sample solution and luminol solution, respectively. The mixture of KMn 4 and β-cd was merged through the eight-way injection valve into the mixture of sample solution and luminol solution. Then the mixed solution was pumped continuously into the flow cell located in front of the detection window of the photomultiplier tube (PMT). The CL emission was converted to current signal by PMT and the output was fed to luminescence analyzer, recorded with a computer via supplied software(remex CL Analysis System V 2.12). The concentration of sample solution was quantified by the relative CL intensity ( I). 3. Results and Discussions 3.1. The CL Characteristics of the Reaction System As shown in Fig. 2,the CL intensity reached a maximum in the absence of sample solution. With the injection of sample solution, a decreased CL signal appeared, and the CL intensity varied with concentration of sample solution. Therefore, the proposed CL system was suitable for detecting hydroquinone and catechol. To obtain the highest CL signal/noise, the flow rate of peristaltic pumps was also tested. The flow rate of pump 1 and 2 were all finally set at 30 turns/min as a suitable condition with superior sensitivity and reagent consumption. Six nanogram per milliliter hydroquinone solution was used to optimize the experimental conditions.

Sensors 2007, 7 581 5000 A B 4000 a a CL intensity 3000 2000 b b 1000 0 Figure 2. The CL characteristics of the reaction system. A. a, Blank: 1.0 10-5 mol/l KMn 4 +1.0 10-4 mol/l β-cyclodextrin+1.0 10-4 mol/l luminol; b, a+ 10 ng/ml hydroquinone; B. a, Blank: 1.0 10-5 mol/l KMn 4 +1.0 10-4 mol/l β-cyclodextrin+1.0 10-4 mol/l luminol; b, a+ 10 ng/ml catechol. 3.2. Effect of β-cd and NaH Concentrations Due to a significant effect of the concentration of NaH medium on the CL system, five different concentration solutions, i.e. 0.02 mol/l, 0.04 mol/l, 0.06 mol/l, 0.08 mol/l, 0.1 mol/l NaH were tested. As shown in Fig. 3, the CL intensity was dramatically increased with the increase of NaH concentration and the highest CL signal/noise was obtained in the 0.04 mol/l NaH, above which the baseline of the system became higher. Therefore, 0.04 mol/l NaH solution was selected for subsequent experiments. The concentration of β-cd was an important factor, because it was used as an enhancer in the reaction. The influence of β-cd concentration on CL intensity was initially examined from 1.0 10 6 to 4.0 10 4 mol/l (Fig. 4). The result indicated that 1.0 10 4 mol/l β-cd gave the highest relative CL intensity and the sensitivity decreased on either side of this value. Therefore, 1.0 10 4 mol/l β-cd was chosen for the subsequent studies. 16000 14000 12000 10000 CL Intensity 8000 6000 4000 2000 0 0.02 0.04 0.06 0.08 0.10 Concentration of NaH( m o l/l ) Figure 3. Effect of NaH concentration on CL intensity (sample = 6 ng/ml).

Sensors 2007, 7 582 5000 4000 CL Intensity 3000 2000 1000 0 0 10 20 30 40 Concentration of β-cd(10-5 mol/l) Figure 4. Effect of β-cd concentration on CL intensity (sample = 6 ng/ml). 3.3. Effect of Luminol Concentration Luminol was not only the reducing agent for the reduction of KMn 4, but also the CL agent in the system. Hence, its concentration should be carefully optimized to ensure that the system was in good stability. The effect of luminol concentration was studied in the range 1.0 10 5 to 0.6 10 3 mol/l (Fig. 5). It was found that the CL intensity was significantly increased with the increase of luminol concentration below 1.0 10 4 mol/l, above which the background signal was also enhanced, leading to the decrease of signal/noise ratio. Thus, 1.0 10 4 mol/l luminol was selected for subsequent work. 4000 3000 CL intensity 2000 1000 0 0 2 4 6 8 10 Concentration of luminol(10-5 mol/l) Figure 5. Effect of luminol concentration on CL intensity (sample = 6 ng/ml). 3.4. Effect of KMn 4 Concentration The influence of KMn 4 at different concentrations from 0.1 10 4 to 3.0 10 4 mol/l were tested (Fig. 6). The peak height increased gradually with raising KMn 4 concentration up to 0.5 10 4 mol/l, above which CL intensity decreased sharply probably because of self-absorption of the KMn 4. It was

Sensors 2007, 7 583 found that the stability of the CL signal fluctuated obviously as the concentration of KMn 4 became 0.5 10 4 mol/l and 0.2 10 4 mol/l. Therefore, 1.0 10 5 mol/l KMn 4 was used for the following studies. 4000 CL intensity 3000 2000 1000 0 0 1 2 3 Concentration of KMn 4 (10-4 mol/l) Figure 6. Effect of KMn 4 concentration on CL intensity (sample = 6 ng/ml). 3.5. Calibration Curves and Detection Limits Under the optimum conditions described, the calibration curves were obtained for hydroquinone and catechol by plotting the graph of I (relative CL intensity) vs. concentration. The measurable range of hydroquinone concentration was 1 10 ng/ml with a regression equation of ΔI = 187.49C + 194.97 (C, ng/ml; r = 0.9942) and the detection limit was 0.1 ng/ml. A series of 13 repetitive measurements of 6 ng/ml hydroquinone yielded a relative standard deviation of 1.1%. The system had a linear respond to catechol concentration in the range 1 20 ng/ml with a detection limit of 0.4 ng/ml and the regression equation was ΔI = 190.09C + 296.69 (C, ng/ml; r = 0.9939). The relative standard deviation for 6 ng/ml catechol was 1.6% (n = 13). 3.6 Interference studies The influence of some common foreign species on the determination of 6 ng/ml hydroquinone was studied under the optimum experimental conditions stated above. The tolerable limit of a foreign species was taken as a relative error not greater than ±5% in the CL signal of hydroquinone. No interference has been found when including up to 1000-fold Na +, K +, S 4 2, N 3, Cl, Br, C 3 2, Ac, NH 4 + ; 500-fold P 4 3, C 2 4 2, Ca 2+, S 3 2, Al 3+, ethanol; 100-fold Mg 2+, Zn 2+, Ni 2+, N 2 ; fivefold S 2, Cu 2+, Hg 2+, Fe 3+, and equal amount of resorcinol and catechol. Metal ions can be eliminated by EDTA [19] and an exchange resin [10]. 3.7 Analytical applications Because of the interference, the proposed method can only determine the hydroquinone or catechol concentration individually. When the system was used for industrial wastewater, the sample should be

Sensors 2007, 7 584 separated in advance. When the samples were river water and fishpond water, the mentioned substances were eliminated by filtration and ions were eliminated by adding an exchange resin [10]. In our work, the developed method was applied to the determination of catechol in river water. The determination results and recoveries are listed in Table 1. It can be seen that recovery varied from 96.0% to 107.0%, indicating that the method developed is suitable for determination of catechol. The system exhibited good stability and reproducibility, with relative standard deviation less than 3%. This is desirable for routine analysis. Table 1. Determination of Catechol in River Water Samples. Sample Amount found Added Found Recovery (ng/ml) a(rsd) (ng/ml) (ng/ml) a (%) River water 1 15.62 (2.2) 1.0 16.58 96.0 3.0 18.75 104.3 River water 2 15.78 (1.8) 1.0 16.85 107.0 a Average of three measurements. 3.0 18.68 96.7 3.8 Possible CL mechanism of the reaction The possible mechanism of the reaction could be demonstrated in Scheme 1. CL is observed after mixing KMn 4 and luminol in a basic solution, which is described in equation 1[20]. The CL signal is greatly enhanced with the addition of β-cd. In order to explain the possible CL mechanism, the subsequent experiments were carried out with the sample solutions. Firstly, the spectra of CL reaction in the luminol KMn 4 β-cd CL system in the presence and absence of sample solutions were measured by F-4500 fluorescence spectrophotometer, and compared with that of a conventional luminol KMn 4 reaction [21,22]. The results showed that the maximum wavelength of CL spectra was identical with that of reported before (~425nm) [21,22]. It is suggested that the emission species is excited luminol. Secondly, the influence of dissolved oxygen on the CL reaction was investigated by purging solution with argon, the CL intensity was decreased by about 60%, this inferred that the dissolved oxygen possibly played a key role in this CL reaction [23]. Thirdly, the effect of ascorbic acid, a common scavenger of free radicals, on the system was studied to ascertain if free radical participated in the reaction. The striking quenching effect was obtained on the addition of ascorbic acid even at 1.0 10 5 mol/l level. The results indicated that free radical may be involved in the CL process (equation 2 and 3). Based on the above-described experimental results, we could conclude that the possible mechanism of the proposed system is a similar behavior as that described previously [10,23]. Singlet oxygen and hydroxyl radical are first formed in this reaction, which then reacts with luminol to produce excited luminol, thus light-emitting is produced. In order to further elucidate the possible CL mechanism, we study the possible products in the reaction via UV-visible absorption spectrum experiment. After adding 0.1g β-cd into the KMn 4 solution (6.0 10 5 mol/l) in 0.04mol/L

Sensors 2007, 7 585 NaH media, the solution becomes green gradually as shown in Fig. 7. In Fig. 7, the two maxima peaks of KMn 4 at 525nm and 545nm disappear [20], with addition of 0.1g β-cd into the solution. And at about 605 nm, a new absorption peak appears, which is assigned to the Mn 4 2- visible absorption [20]. Based on the above-described experimental results, KMn 4 seems to be reduced to K 2 Mn 4 in the reaction. With the addition of sample solution, hydroquinone and catechol are oxidized by hydroxyl radical and singlet oxygen to produce corresponding quinones [10], hence a decreased CL signal is observed (equation 4 and 5). NH 2 NH 2 NH NH KMn 4 H - _ + hv _ (1) CH 2 H H H 7 Mn 4, 2 H CH 2 H CH 2 H H CH CH + Mn 4 + 1 2 + H H 6 2 (2) NH 2 NH 2 NH 1 2 _ + hv (3) NH H _ H H 1 2 H (4) H H 1 2 H (5) Mn 4 + β-cd + Luminol hydroquinone or catechol Quenching the Light (6) Scheme 1. Possible reaction process of the present system.

Sensors 2007, 7 586 0.20 0.18 0.16 0.14 (A) Absorbance 0.12 0.10 0.08 0.06 (B) 0.04 0.02 0.00 (C) 500 550 600 650 Wavelengh (nm) Figure 7. UV vis absorption spectra: (A) KMn 4 (B) KMn 4 +β-cd (C) β-cd 4. Conclusions A new flow-injection CL method is developed for the determination of hydroquinone and catechol, based upon the inhibitory effects on the luminol KMn 4 β-cyclodextrin reaction in alkaline solution. The system exhibits good stability, reproducibility and satisfactory detection limit. After some pretreatments of industrial wastewater and river water mentioned above, the method can be applied to the determination of hydroquinone and catechol. The proposed method offers the advantages of simplicity, rapidity, and high sensitivity for the determination of hydroquinone and catechol, and can be adopted as an alternative to the existing methods. Further research work on this subject is still in progress, the CL reaction developed can be coupled with high performance liquid chromatography (HPLC) to simultaneously determine hydroquinone and catechol. Acknowledgements This study was supported by the National Natural Science Foundation of China (No. 20570542) and the Innovation Foundation of Sichuan University (No: 2006G006). References 1. Rueda, M. E.; Sarabia, L. A.; Herrero, A.; rtiz, M.C. ptimisation of a flow injection system with electrochemical detection using the desirability function Application to the determination of hydroquinone in cosmetics. Anal. Chim. Acta. 2003, 479, 173-184. 2. Cui, H.; He, C. X.; Zhao, G. W. Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection. J. Chromatogr. A. 1999, 855, 171-179.

Sensors 2007, 7 587 3. Lavrent, K.; Julien, A.; Zofia, M.; Barry, D. Formation of Cyclopentadienyl Radical from the Gas-Phase Pyrolysis of Hydroquinone, Catechol, and Phenol. Environ. Sci. Technol. 2006, 40, 5071-5076. 4. William, S. S.; Robert, M. M.; Maurice, E. S.; Ralph, E. W. Pyrolytic Studies on the Contribution of Tobacco Leaf Constituents to the Formation of Smoke Catechols. J. Agric. Food Chem. 1982, 30, 372-374. 5. Steven, G. C ; Stephen, S. H ; T. C. T ; Dietrich, H. Roles of Tobacco Cellulose, Sugars, and Chlorogenic Acid as Precursors to Catechol in Cigarette Smoke. J. Agric. Food Chem. 1984, 32, 267-273. 6. Nagaraja, P.; Vasantha, R. A.; Sunitha, K. R. A new sensitive and selective spectrophotometric method for the determination of catechol derivatives and its pharmaceutical preparations. J. Pharm. Biomed. Anal. 2001, 25, 417-424. 7. Parham, H.; Pourreza, N.; Cheraghi, S. Kinetic-spectrophotometric determination of trace amounts of resorcinol based on its inhibitory effect on the formaldehyde catalyzed reaction between bromate and neutral red. Anal. Lett. 1999, 32, 1917-1926. 8. Wang, L. H.; Kuo, Y. P. Simultaneous quantitative determination of resorcinol and 1-naphthol in haircolor products by high-performance liquid chromatography. Chromatographia, 1999, 49, 208-211. 9. Sun,Y. G.; Cui, H.; Li, Y. H.; Lin, X. Q. Determination of some catechol derivatives by a flow injection electrochemiluminescent inhibition method. Talanta. 2000, 53, 661-666. 10. He, D. Y.; Zhang, Z. J.; He, C. Investigation on the interaction between dihydroxybenzene and Fe 3+ -H 2 2 -Rh6G system based on enhancing chemiluminescence. Luminescence, 2006, 21, 15 11. Kamil. M ; Antonije,.; Pavel, M.; Zbyneˇk, V. Flow-injection chemiluminescence determination of formaldehyde in water. Talanta. 2007, 71, 900 905. 12. Cao, W.; Yang, J. H.; Sun, C. X.; Zhang, Z. J.; Gao, Q. F. Flow-injection-chemiluminescence method for the determination of penicillin G potassium. Luminescence. 2005, 20, 238-242. 13. Lv, Y.; Zhao, R.; Zhu, Z. L.; Xu, X.S.; Zhang, X. R. A novel chemiluminescence method for the determination of orciprenaline based on ferricyanide-rhodamine 6G. Luminescence. 2005, 20, 298-302. 14. Yao, H.; Sun, Y. Y.; Lin, X. H.; Cheng, J. H.; Huang, L. Y. Flow-injection chemiluminescence determination of catecholamines based on their enhancing effects on the luminol potassium periodate system. Luminescence. 2006, 21, 112-117. 15. Cui, H.; Xie, C. G.; Lai, C. Z. A novel chemiluminescent method for determination of phloroglucinol. Luminescence. 2003, 18, 318-323. 16. Liu, E. B.; Xue, B. C. Flow injection determination of adenine at trace level based on luminol K 2 Cr 2 7 chemiluminescence in a micellar medium. J. Pharm. Biomed. Anal. 2006, 41, 649-653. 17. Du, J. X.; Li, Y. H.; Lu, J. R. Flow injection chemiluminescence determination of polyhydroxy phenols using luminol ferricyanide/ferrocyanide system. Talanta 2001, 55, 1055-1058. 18. Lu, Y.; Zhang, Z. J.; He, D. Y.; Hu, Y. F. Flow injection chemiluminescence determination of polyhydroxy phenols in the presence of Rhodamine B as a sensitiser. Chem. Anal. 2003, 48, 959-966.

Sensors 2007, 7 588 19. Song, Z. H.; Wang, L. Resorcinol chemosensor based on detection of chemiluminescence with immobilized reagents. Microchem. J. 2001, 68, 47-52. 20. Du, J. X.; Liu, W. X.; Lu, J. R. Investigation on the chemiluminescence behavior of alkaline earth metal ions Mg 2+, Ca 2+, Sr 2+ and Ba 2+ in luminol-permanganate reaction. Acta Chimica Sinica. 2004, 14, 1323-1326. 21. Li, Y. H.; Niu, W. F.; Lu, J. R. Sensitive determination of phenothiazines in pharmaceutical preparation and biological fluid by flow injection chemiluminescence method using luminol KMn4 system. Talanta 2007, 71, 1124 1129. 22. Emil, H. W.; liver. Z.; Heinz, H. K.; John, H. M. H. Chemiluminescence of Luminol and Related Hydrazides : The Light Emission Step. J. Am.Chem.Soc. 1964, 86, 941-942. 23. Cao, Z. J.; Choiwan. L.; Lu. J. Z. A general chemiluminescence method for the determination of surfactants based on its quenching effect on the luminol-nai 4 -cyclodextrin reaction. Analyst. 2004, 129, 1262-1266. 2007 by MDPI (http://www.mdpi.org). Reproduction is permitted for noncommercial purposes.