Micro Computed Tomography Based Quantification of Pore Size in Electron Beam Melted Titanium Biomaterials

Similar documents
Trabecular Metal Material Spine Overview. Page 1 of 6

MAPPING FRACTURE APERTURES USING MICRO COMPUTED TOMOGRAPHY

HOMOGENIZATION OF TRABECULAR BONE MICROSTRUCTURE BASED ON FINITE ELEMENT METHOD AND MICRO COMPUTED TOMOGRAPHY

Supplementary Data Supplementary figures

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

arxiv: v1 [physics.med-ph] 21 Nov 2013

Biomaterial Scaffolds

This section develops numerically and analytically the geometric optimisation of

A GLOBAL LEADER IN METAL AM QUALITY ASSURANCE

X-Ray Microtomography and NMR: complimentary tools for evaluation of pore structure within a core

AM Metrology at NPL. Stephen Brown. Tuesday 8 th December 2015

X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT. University of California Davis. Dorthe Wildenschild & Annette Mortensen

Michael Lee Spring 2015 PHYS570: Introduction to Synchrotron Radiation

Template-Free Synthesis of Highly Porous Boron. Nitride: Insights into Pore Network Design and Impact

A direct evaluation of the Fabric Tensor in anisotropic porous media

Regular, low density cellular structures - rapid prototyping, numerical simulation, mechanical testing

Supporting Information

PILLAR P E E K A N D P T C S P A C E R S Y S T E M PEEK PTC

Excerpt from the Proceedings of the COMSOL Conference 2009 Milan

Structure analysis of rock by X-ray microtomography and PMMA-impregnation Kiven huokostilavuuden kuvaus tomografiamenetelmillä

Generalizing the mean intercept length tensor for gray-level images

Geometry modeling of open-cell foams for efficient fluid flow and heat transfer computations using modified Kelvin cells

ANALYSIS OF A SLOPE FAILURE IN AN OPEN PIT MINE USING TSLOPE

Principles of Nuclear Magnetic Resonance Microscopy

Developments & Limitations in GSR Analysis

Supporting Information

A Riemannian Framework for Denoising Diffusion Tensor Images

Basics of Diffusion Tensor Imaging and DtiStudio

Nanoscale IR spectroscopy of organic contaminants

The detection of subsurface inclusions using internal measurements and genetic algorithms

ALICE Tomography Section: Measurements and Analysis

Simulating Fluid-Fluid Interfacial Area

Objective Mathematics

X-ray Computer Tomography

Specific surface area computed with X-ray micro-tomography:

Computational Simulation of Cancellous Bone Remodeling Using Digital Image-based Model

Application of Automated detection techniques in Magnetic Data for Identification of Cu-Au Porphyries

Metal Artifact Reduction and Dose Efficiency Improvement on Photon Counting Detector CT using an Additional Tin Filter

SEAFLOOR MAPPING MODELLING UNDERWATER PROPAGATION RAY ACOUSTICS

A CONTACT-MECHANICS BASED MODEL FOR DISHING AND EROSION IN

Automated atom-by-atom 3D reconstruction of field ion microscopy data

Sequential Monte Carlo Methods for Bayesian Model Selection in Positron Emission Tomography

Master Projects in Materials Physics, 2014 / 2015

Disordered Structures. Part 2

A Laplacian of Gaussian-based Approach for Spot Detection in Two-Dimensional Gel Electrophoresis Images

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

This chapter focuses on the study of the numerical approximation of threedimensional

Linköping University Electronic Press

Optics of complex micro structures

Monte Carlo Simulation of Long-Range Self-Diffusion in Model Porous Membranes and Catalysts

Supplementary Information

M3-4-5 A16 Notes for Geometric Mechanics: Oct Nov 2011

Towards Proton Computed Tomography

A network model for characterizing brine channels in sea ice

Initial Studies in Proton Computed Tomography

NEW BALANCING PRINCIPLES APPLIED TO CIRCUMSOLIDS OF REVOLUTION, AND TO n-dimensional SPHERES, CYLINDROIDS, AND CYLINDRICAL WEDGES

Technical University of Denmark

EE 4372 Tomography. Carlos E. Davila, Dept. of Electrical Engineering Southern Methodist University

Anisotropic permeabilities evolution of reservoir rocks under pressure:

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES

UAV Navigation: Airborne Inertial SLAM

Iterative Data Refinement for Soft X-ray Microscopy

OHSx XM521 Multivariable Differential Calculus: Homework Solutions 13.1

Trabecular Bone Structure of the Calcaneus: : Comparison of high resolution MR Imaging at 1.5T and 3T using MicroCT as a standard of reference

MICROSTRUCTURAL AND ELASTIC PROPERTIES OF SHORT FIBER REINFORCED COMPOSITES

Pore Scale Analysis of Oil Shale/Sands Pyrolysis

Track Fitting With Broken Lines for the MU3E Experiment

MATHEMATICS. SECTION A (80 Marks)

Data Acquisition and Image Formation Methods for Multi Energy CT

SPHERICAL NEAR-FIELD ANTENNA MEASUREMENTS

Chapter 12. Nanometrology. Oxford University Press All rights reserved.

Ultrashort Pulse Laser Technology for Processing of Advanced Electronics Materials

CFD SIMULATIONS OF SINGLE AND TWO-PHASE MIXING PROESSES IN STIRRED TANK REACTORS

Machine Positioning Uncertainty with Laser Interferometer Feedback

Supporting Information. Methane bubble growth and migration in aquatic sediments observed by X-ray µct

No turning round: abusing µct as an X-ray transmission microscope

Application of the TRT LB model to simulate pesticide transport in cultivated soils

Team Captain: Ben Jones Design and Modeling: Elizabeth Ashley Modeling: Kerry Toole Prototyping and Secretary: Rachel Stein Treasurer: Mari Hagemeyer

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

COMSOL Thermal Model for a Heated Neural Micro-Probe

Quantifying and mitigating correlated noise between formed beams on the ASKAP Phased Array Feeds

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

GRAPHENE FLAGSHIP. Funded by the European Union

A Second-order Finite Difference Scheme For The Wave Equation on a Reduced Polar Grid DRAFT

Chapter I : Basic Notions

Supplements to : Isotropic stress reduces cell proliferation in tumor spheroids

Fraunhofer Institute for Computer Graphics Research Interactive Graphics Systems Group, TU Darmstadt Fraunhoferstrasse 5, Darmstadt, Germany

Enhanced Surface Metrology

A Numerical Investigation of Laser Heating Including the Phase Change Process in Relation to Laser Drilling

Distributed Data Fusion with Kalman Filters. Simon Julier Computer Science Department University College London

Chem 728 Introduction to Solid Surfaces

Holographic Characterization of Agglomerates in CMP Slurries

Principal Component Analysis -- PCA (also called Karhunen-Loeve transformation)

Distance Formula in 3-D Given any two points P 1 (x 1, y 1, z 1 ) and P 2 (x 2, y 2, z 2 ) the distance between them is ( ) ( ) ( )

Module 16. Diffusion in solids II. Lecture 16. Diffusion in solids II

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

The construction of complex networks from linear and nonlinear measures Climate Networks

NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT

Kirk Borne Booz Allen Hamilton

MATH 332: Vector Analysis Summer 2005 Homework

Transcription:

Micro Computed Tomography Based Quantification of Pore Size in Electron Beam Melted Titanium Biomaterials SJ Tredinnick* JG Chase ** *NZi3 National ICT Innovation Institute, University of Canterbury, Christchurch, New Zealand (e-mail: seamus.tredinnick@pg.canterbury.ac.nz ** Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand (e-mail: Geoff.chase@canterbury.ac.nz) Abstract: This paper presents a new method for the quantification of pore size of scaffold biomaterials from micro computed tomography (µct). A two dimensional implementation of a spherical pore approximation model and a novel pore quantification algorithm have been applied to actual and phantom µct reconstructions and the accurate measurement of pore size has been demonstrated. This paper describes the circular pore model used for the two dimensional analysis, a spherical pore model for three dimensional analysis, the algorithm for quantifying pore size, and the mechanics of the algorithm for both the 2-D and 3-D implementations. Keywords: algorithms, biomedical systems, 3-D metallic constructs, metallic bone scaffolds, bone tissue engineering 1. INTRODUCTION The Electron Beam Melting (EBM) of titanium to produce bone interfacing orthopaedic biomaterials is now in common use. These EBM titanium scaffolds are typically highly interconnected, ordered structures with large macro sized pores well in excess of traditional pore sizes such as those investigated by Marin (2010). Many of these titanium scaffolds have demonstrated excellent osseointegration properties as summarized by Alvarez and Nakajima (2009). With the advancement of scaffold architecture moving away from random and orthogonal lattices and towards bone mimicking morphology (trabecular structure) and incorporating aesthetic driven design the quantification of pore size has become more challenging. Significant work has been performed relating pore size to bone in-growth for orthopaedic biomaterials and so it is vital to the advancement of scaffold biomaterials that this metric be included in any design or analysis. There are limits of pore size above which vascularization of bone in-growth can occur and ranges of pore size that are more favourable to bone in-growth for specific pore architectures (Karageorgiou, 2005). This information can be easily incorporated in to scaffold design if the pore size of the scaffold can be readily determined. The application of micro computed tomography (µct) for pore quantification gives the capability to produce volumetric reconstructions in high resolution; typically 1-50µm per voxel. µct scanning is non-destructive and can be performed on complete products to give insight to the final product structure in a production setting. Additionally, µct can be used for bone in-growth, apposition, and quality quantification in-vitro, in-vivo, and ex-vivo (Jones, 2004). However, determining the pore characteristics of complex morphologies from a µct scan can require a great deal of user input as traditional approaches have required the user identification of individual pores and landmarks from which to take measurements. The algorithm presented takes an approach that can differentiate a pore from the surrounding interconnect region, approximate the pore diameter and do so in a scalable and automated environment to enable statistically relevant quantification to be performed in an automated fashion. The basis of the method presented is a spherical pore model which aims to simplify complex pore architecture and provide a comparative metric that can be used with many differing scaffold morphologies. 2.1 Pore Model 2. METHODS For any interconnected scaffold structure the strut arrangement will constrain a porous region. Although the arrangement of the struts may be complex, for most strut arrangements the porosity can be adequately described as a collection of pores and interconnecting boundaries. With a spherical pore approximation model the individual pores constrained by a series of struts are modelled as the largest circumscribed spherical volume with the diameter of the sphere indicating the diameter of the pore. All internal fully constrained regions of a scaffold are described in this way. Where spherical pores intersect one and other the boundary between the adjacent pores is defined to be the interconnect region. When dealing with highly interconnected structures, such as in (Fig. 1), there is often little differentiation between

adjacent pores. With a spherical pore approximation model pores are identified with a hierarchical approach where larger pores are determined before smaller pores. This approach ensures that an accurate indication of true pore size is achieved and that interconnecting regions are not falsely determined to be small pores. Centre Initialisation Diameter Expansion Centre Migration Diameter Maximisation Fig. 2. A schematic diagram of the pore quantification algorithm for an individual pore. 2.3 Algorithm Mechanics 2.3.1 Determining the solution space and its boundaries Fig. 1. A three dimensional µct reconstruction of a complex scaffold manufactured by EBM. The scaffold is 5mm in diameter and 6mm in length. 2.2 Algorithm Overview The constraint of a pore is achieved by a series of contact points. In the simple case when dealing with two dimensional slice data a circular pore can be fully defined by three contact points. When a three dimensional volumetric reconstruction is used a spherical pore is fully defined by four contact points. Of importance to the accuracy of the pore approximation is the maximization of the pore size within the constraints of the scaffold. When dealing with complex structures the best approach is an iterative method that allows the incremental search from an initiation site to a local maximum in pore diameter while allowing the pore centre to shift as necessary to achieve this. The iterative migration of the pore centre is in a direction that allows the greatest expansion of the pore in a given iteration. At each step of the search for a local maximum of pore diameter the contact points of a pore are re-established by expanding the pore to meet the closest contact points and where a new contact point is made a substitution of contact points occurs. If the pore is not fully constrained the pore is migrated to a new location. When a local maximum in pore diameter has been found the change in pore diameter will remain constant for all subsequent iterations and the search is complete. As this process is repeated over many pore initiation sites all local maxima of pore diameters are found within the constraints of a scaffold and as such the sizes and locations of the pores of a scaffold are described. The solution space where the algorithm may look for pores is the inverse space of the struts comprising a scaffold and may be bounded externally by an artificial boarder. The boundaries of this solution space are the surfaces of the struts within a scaffold and are potential contact point locations. 2.3.2 Selecting suitable initiation sites To ensure all pores within a scaffold are identified, suitable initiation sites for the search of pores must be selected. As pore centres will lie in regions of the solution space far away from the boundary these regions should be preferentially chosen for initiation sites. Pore initiation sites should be hierarchically chosen to favour sites farther from the boundary than those close to the boundary. As subsequent pores are found the regions of the solution space occupied by pores already quantified should be excluded from the search process. 2.3.3 Defining a pore in two dimensions In the 2D regime a pore can be quantified as the largest possible circumcircle to fit within an area of interest. The circumcircle is fully defined by three contact points and a geometric construction of the circumcircle is given by Pedoe (1995). 2.3.4 Migration of a pore during a search in two dimensions To determine the size of a pore contained within a region of the scaffold the pore is first initiated in an arbitrary location then expanded radially to fill the pore site. During this process the pore centre may migrate to enable the local maximum in pore diameter to be found. In 2D this migration is determined in the following ways: where there is one contact point the direction of the migration is opposite to the direction of the ray extending to that contact point (Fig. 3); where there are two contact points the direction of the migration is opposite to the bisector of the angle between the two rays extending to the two contact points (Fig. 4). Where there are three contact points the circular pore is fully defined (Fig. 5).

of having 3 contact points. For three contact points the direction of migration is the opposite to the trisector of the angles made between rays extending to the three contact points (an extension of the case shown in Fig. 4). Where there are four contact points the spherical pore is fully defined. 2.3.7 Determining the interconnecting boundaries of pores Fig. 3. Migration direction for one contact point. Where there are two adjacent pores the minimum throat diameter of the interconnecting region between them is considered to be the interconnecting boundary. For a 2D reconstruction this boundary is a linear and for a 3D reconstruction this boundary is planar. 3. RESULTS 3.1 A simple pore in two dimensions from phantom data To demonstrate the pore model and ensure the algorithm can accurately determine pore size a simple phantom was evaluated. A phantom consisting of a simple cubic structure with two dimensional slices oriented at 0 was used (Fig. 6). The two dimensional image produced had a canvas size of 100x100 pixels (px). Circular struts (each 10px in diameter) were placed at the corners of the canvas. The algorithm was applied to this phantom and the pore size was measured. Fig. 4. Migration direction for two contact points. Fig. 5. The circle is fully defined by three contact points. 2.3.5 Defining a pore in three dimensions In the 3D regime a pore can be quantified as the largest possible circumsphere to fit within a volume of interest. The circumsphere is fully defined by four contact points and can be constructed with an extension of the geometric construction of the circumcircle. 2.3.6 Migration of a pore during a search in three dimensions In 3D the pore centre migration is determined in a similar fashion as for 2D with an extension of this method in the case Fig. 6. Two dimensional pore quantification of a pore in a simple cubic scaffold phantom. Table 1. Phantom pore quantification Actual Pore Measured Pore Error Diameter [px] Diameter [px] 90.5 90.47 2.7% The pore was found to be 90.47 pixels in diameter which is within 2.7% error of the original dimensions of the phantom pore indicating that the algorithm can accurately determine pore size.

3.2 A simple pore in two dimensions from µct data Following the validation of the algorithm on phantom data the pore size of a µct slice of an EBM scaffold was analysed. Analysing actual data is significantly more challenging that simulated data due to significant levels of noise both in the form of CT artefact and topographical roughness of the scaffold. To deal with CT artefact the image was filtered to reduce noise prior to analysis. The robust application of the pore migration techniques (2.3.2) ensured that the local maximum in pore diameter was found irrespective of topological roughness. A two dimensional slice (Fig. 8) of unit cell of a simple scaffold (Fig. 7) was chosen and the pore size of the bounded pore was quantified. A comparison was made showing the difference in pore size reported with the spherical pore approximation model to a traditional µct technique, such as that shown in by Ho, S.T. (2006), which involves measurement of a pore between scaffold struts at the surface of a scaffold. Fig. 10 shows the pore size measurement for a simple scaffold that would be reported using this technique. Fig. 9. Two dimensional pore quantification of the pore in the simple cubic scaffold unit cell shown in Fig. 7 The pore diameter was determined to be 3.39 mm based on a scan resolution of 17.47 µm/px. Fig. 7. A three dimensional µct reconstruction of a unit cell of a simple scaffold manufactured by EBM. Fig. 10. Pore size measurement from µct reconstruction showing the pore diameter measurement that would be reported using a traditional method. The pore diameter was determined to be 2.87 mm. Table 2. Pore measurements of a simple scaffold Spherical Pore Approximation Model Traditional measurement of pore diameter Difference 3.39 mm 2.87 mm -15% Fig. 8. A filtered and thresholded two dimensional slice reconstructed from a µct scan of the unit cell of the simple EBM scaffold shown in Fig. 7. The measured pore diameters in Table 2 indicate that a traditional reporting technique gives a smaller pore diameter than the spherical pore approximation model measuring the pore diameter within the scaffold cell. Furthermore, according to the spherical pore approximation model, the measurement of the distance between struts at the surface of a scaffold would more accurately describe the diameter of an interconnecting region between fully contained pores.

3.3 A complex pore in two dimensions A two dimensional slice of a complex scaffold was chosen and the pore size of a single pore was quantified. The pore located in the central region of the image was chosen for analysis. The original scaffold was cylindrical and nominally 5mm in diameter. The scan was performed at a resolution of 6.94 µm/px.\ full resolution data and half resolution data to show that search time can be reduced by down sampling the data with negligible effect on the accuracy of the results. A 75% reduction in the number of pixels in the image resulted in the computation time dropping to 50% of the original value with an insignificant 0.1% change in the diameter of the pore. Table 4. Effect of resolution on computation time Particular Value Difference Image size [px] 300x300 150x150-75% Time [sec] 0.021 0.011-50% Pore dia [µm] 898.0 897.2-0.1% Fig. 11. The filtered and thresholded central region of a two dimensional slice reconstructed from a µct scan of a complex EBM scaffold. 4. DISCUSSION AND FUTURE WORK The pore model and quantification algorithm was successfully implemented for a phantom scaffold and simple and complex EBM scaffolds in two dimensions only. A three dimensional implementation of the algorithm would allow this method to be used for the volumetric quantification of pore size from µct data. The pore model was effective for approximating complex pore architecture. The pore centre migration methods were found to be effective in discovering the local maxima in pore diameter within the complex topography of EBM scaffolds. In the two dimensional analysis of a phantom scaffold the algorithm determined the pore size to within 2.7% of the actual maximum diameter of the region of interest. The spherical pore approximation model reported a larger pore diameter than a traditional µct technique. For high resolution data it was shown that a pore can be effectively and quickly discovered and that the computation time can be decreased significantly by down sampling the data with little loss of accuracy. Fig. 12. The processed image showing the pore quantified. Table 3. Complex pore quantification Measured Pore Measured Pore Diameter [px] Diameter [µm] 129.4 898.0 From an arbitrary starting location in the central region of the image a pore was successfully located. The pore migration allowed for the maximisation of the pore within the area of interest. The maximum diameter of a circular pore in this region was found to be 898.0 µm. This evaluation was performed at the full resolution of the original data (300x300 px). A comparison was made between 5. REFERENCES Alvarez, K., Nakajima, H. (2009). Metallic scaffolds for bone regeneration, Materials 2, Issue 3, Pages 790-832. Ho, S.T., Hutmacher, D.W. (2006). A comparison of micro CT with other techniques used in the characterization of scaffolds, Biomaterials, Volume 27, Issue 8, Pages 1362-1376. Jones, A., et al. (2004). Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imaging, Biomaterials, Volume 25, Issue 20, Pages 4947-4954. Karageorgiou, V., Kaplan, D. (2005). Porosity of 3D biomaterial scaffolds and osseogenesis, Biomaterials, Volume 26, Issue 27, Pages 5474-5491. Marin, E., et al. (2010) Characterization of cellular solids in Ti6Al4V for Orthopaedic implant applications: Trabecular titanium, Journal of the Mechanical Behaviour of Biomedical Materials 3, Issue 5, Pages 373-381. Pedoe, D. (1995). Circles: A Mathematical View, rev. ed. Washington, DC: Math. Assoc. Amer.