THE USE OF IONISING RADIATION IN THE MANUFACTURE OF MEDICINAL PRODUCTS

Similar documents
PART II VIII. CONCERNING CHEMICAL. PHARMACEUTICAL AND BIOLOGICAL DOCUMENTATION FOR RADIOPHARMACEUTICAL PRODUCTS.

COMMITTEE FOR HUMAN MEDICINAL PRODUCTS (CHMP) GUIDELINE ON RADIOPHARMACEUTICALS

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Guide to Registration Requirements for Active Substance Manufacturers, Importers and Distributors in Ireland

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE

English - Or. English NUCLEAR ENERGY AGENCY STEERING COMMITTEE FOR NUCLEAR ENERGY

Materials Approach using the Toyograph CAS Number Approach

Environmental Authorisations (Scotland) Regulations Authorisation guide for radioactive substances activities

LECTURE 4 PRINCIPLE OF IMAGE FORMATION KAMARUL AMIN BIN ABDULLAH

2016 No. 410 (W. 128) WATER, ENGLAND AND WALES. The Water Supply (Water Quality) (Amendment) Regulations 2016

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

B REGULATION (EU) No 649/2012 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 concerning the export and import of hazardous chemicals

Swiss Medic Training Sampling

NZQA unit standard New US6 to replace and version 1 Page 1 of 5

DSM (FAD ; CRL/160047)

Letter to non European Union customers

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

INTERNATIONAL STANDARD

Regulatory use of (Q)SARs under REACH

Rosemary extract liquid

Active concentration for material not requiring radiological regulation

Update of current activities

Application of national regulations for metallic materials recycling from the decommissioning of an Italian nuclear facility.

VERSION 3.0 MARKS & SPENCER NOVEMBER 2015 ECP MINUMUM STANDARDS REACH. Registration, Evaluation and Authorisation of Chemicals

Cleaning Memo for January 2017 A Critique of the APIC Guideline

Radiological Protection Principles concerning the Natural Radioactivity of Building Materials

Accurate prediction of radiation exposures of workers involved in the transport of NORM

Guideline. Mary O Grady Quality Assessment Manager. IMB New Variations Regulation Information Day /01/2010 Slide 1

Draft agreed by the QWP June Draft endorsed by the CMD(v) June Draft adopted by the CVMP for release for consultation July 2016

Fact sheet on Intermediates under REACH

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

Name: COMBINED SCIENCE Topics 4, 5 & 6 LEARNING OUTCOMES. Maintain a record of your progress Use the booklet to guide revision

Nuclear Science Merit Badge Workbook

RADIATION SAFETY GUIDELINES FOR NON-USERS

The electron accelerator of the ISOF-CNR Institute: its characteristics and use

Guidance for Industry M4: The CTD General Questions and Answers

COMMITTEE FOR MEDICINAL PRODUCTS FOR VETERINARY USE (CVMP)

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

Q/A-LIST FOR THE SUBMISSION OF VARIATIONS ACCORDING TO COMMISSION REGULATION (EC) 1234/2008

Challenges of Nanomaterial Regulation in Europe. November 8th 2016, Grenoble Dr. Julia Donauer

Pharmaceutical Active Ingredients Group Standard 2017 HSR100425

Chemical Legislation and Regulations Updates: Japan

Step-by-Step Guide to the REACH Regulations

REACH Pre-registration & Registration - Questions and Answers

IMPACT OF PARTICLE AGGREGATED MICROBES AND PARTICLE SCATTERING ON UV DISINFECTION

ICH Topic M 4 Common Technical Document for the Registration of Pharmaceuticals for Human Use Questions and Answers. Step 5

DRAIN TRACING DYE RED E123

Health, Safety, Security and Environment

SECTION H CHEMICAL WEAPONS DESTRUCTION FACILITIES REQUIRED UNDER PARTS IV(A) OF THE VERIFICATION ANNEX OF THE CONVENTION

QUESTIONNAIRE: REACH INTRODUCTION

TRADE IN RADIATION SOURCES

Introduction to E&Ls 1

Michigan Small Animal Imaging Resource Center for Molecular Imaging. Department of Radiology. University of Michigan

New Policies on Chemical Environmental Management in China. Gao Yingxin Chemical Registration Center of MEP September 9, 2010

Chemical Control Legislation In Japan

Irradiation by Ionizing Radiation Comparison of Ebeam, Xray with Gamma

level 4 (6 SCQF credit points)

Chapter V: Cavity theories

PHYS 3650L - Modern Physics Laboratory

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

Nanomaterials, REACH and CLP - what is going on at the regulatory front

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

GHS Classification CONCEPT OF GHS

7/8/2013. What is GHS?

Validation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp

Nanomaterials under REACH

QUESTIONNAIRE: REACH INTRODUCTION

Quantifying exposure from radionuclides for environmental receptors

Applied General Science Glossary of terms (TVQ01028, TVQ01029)

GUIDELINES OF PROCUREMENT - CHEMICALS FOR RESEARCH CHEMICAL MANAGEMENT CENTRE

Study of REACH Regulation in EU about Electrolytic Capacitor

Contents Introduction Purpose Background What is a hazardous chemical? What is the GHS?...

Nuclear medicine and Radiation technologies

THERAPEUTIC GOODS SAMPLING Application to Tablet Manufacture and Ingredients. David Edmonds CMC Regulatory

Chemical Changes and Structure. level 6 (3 SCQF credit points)

VALIDATION OF ANALYTICAL METHODS. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

Gabriele Hampel 1, Uwe Klaus 2

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

Testing for particles in injectable products

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

Peptides as Radiopharmaceuticals: CMC Perspectives

Importance of uncertainties in dose assessment to prove compliance with radiation protection standards

ISO INTERNATIONAL STANDARD

O R D E R OF THE HEAD OF THE STATE NUCLEAR POWER SAFETY INSPECTORATE

REACH (EU Strategy for new chemicals) & Success Service. Dr. Andreas Kicherer

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

This document is a preview generated by EVS

Source Protection Zones. National Dataset User Guide

REACH: HOW IT AFFECTS PSA TAPES

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

Revision of GRE/2017/05

Become Aware: Preparation for a Radiological Terrorism Event Ionizing Radiation and Its Biological and Human Health Effects

Standard Practice for Heat Aging of Plastics Without Load 1

REACH 15 questions which concern you. A Guide for Downstream Users

Manual Railway Industry Substance List. Version: March 2011

Polymers (Toxic [6.1]) Group Standard HSR002645

Hazard Communication

Revision checklist. Step Learning outcome Had a look Nearly there Nailed it!

Storing, using and disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements

Transcription:

THE USE OF IONISING RADIATION IN THE MANUFACTURE OF MEDICINAL PRODUCTS Guideline Title The use of Ionising Radiation in the Manufacture of Medicinal Products Legislative basis Directive 75/318/EEC as amended Date of first adoption December 1991 Date of entry into July 1992 force Status Last revised December 1991 Previous titles/other None/III/9109/90 references Additional Notes This note for guidance deals with the use of ionising radiation in the manufacture of medicinal products. It should be read in conjunction with Volume IV of The Rules Governing Medicinal Products in the European Union, particularly the annex on ionising radiation. CONTENTS 1. INTRODUCTION 2. ADMINISTRATIVE DATA 3. MANUFACTURING PROCESS 4. VALIDATION OF THE IRRADIATION PROCEDURE GLOSSARY 23

THE USE OF IONISING RADIATION IN THE MANUFACTURE OF MEDICINAL PRODUCTS 1. INTRODUCTION This note for guidance is intended for applicants wishing to use ionising radiation in the manufacture of medicinal products. Irradiation may be used for microbial decontamination, sterilisation or other treatments. Different materials or products may be irradiated: starting materials, packaging materials, intermediate products, bulk products and finished products. Information should be given in sufficient detail to enable the competent authority to evaluate whether or not the manufacturing subprocess is effective and the product is safe for the patient. Manufacturers using ionising radiation in the manufacture of medicinal products should refer to the Guide to Good Manufacturing Practice (Volume IV of The Rules Governing Medicinal Products in the European Union ) and in particular to the annex on ionising radiation used in the manufacture of medicinal products and, where relevant, to the annex on manufacture of sterile medicinal products. 2. ADMINISTRATIVE DATA a) The name and description of the product (including its packaging material) to be irradiated should be given. Its shape, size and composition (type and quantity of substances) should be described in detail. Furthermore, it should be made clear whether starting materials, packaging materials, intermediate products, bulk products or the finished product are irradiated. Sizes of production batches and of irradiation batches should be defined. In the case of a continuous process, a batch comprises all the units processed in a given period of time. b) The purpose of the irradiation should be stated. Both the minimum dose to achieve this purpose and the maximum permissible dose should be stated. c) In addition to the names and addresses of all manufacturers involved in the manufacture of the product, the name and address of the irradiation plant should be given, making clear which operations are to be conducted at which site. d) A copy of the authorisation referred to in Directive 75/319/EEC as amended and covering the irradiation plant should be attached to the application. 3. MANUFACTURING PROCESS Irradiation of a medicinal product is part of its manufacturing process and the description of that part of processing should be sufficiently detailed. The application should include the following information: 25

3AQ4a 3.1 Description of the irradiation plant a) Type (radionuclide source, electron generator) and builder of the plant; b) working mode (batch- or continuous mode); c) authorised and actual activity of the radionuclide in the radiation source (GBq), or the maximum and minimum electron energy (MeV) of the generator as appropriate; d) concise description of the plant including drawings, showing clearly the course of the product within the plant, the position and geometry of the irradiation source and the conveyor system including the source pass mechanism. 3.2 Description of the irradiation process a) a description of the material to be irradiated should be given, including limits (if any) on bioburden and any process aimed to limit or control the bioburden. Action to be taken when particular bioburden limits are exceeded should be stated; b) the number and positions of the irradiation containers in relation to the position of the source during the whole dwelling time, and the method of moving them through the chamber, should be described; c) the material and dimensions of the irradiation container should be described; d) the maximum total irradiation time and the maximum dwelling time of the product i n the irradiation chamber should be stated; e) results of dose mapping studies using a dummy product are required; f ) the loading pattern of the product must be stated for each irradiation container. If the load consists of mixed products, the composition of the load must be described including their stated position in the irradiation container. The mean density of the load and the acceptable maximum density should be given. A modification of the loading pattern may be acceptable provided a new dose mapping is performed, showing that the stated minimum and maximum doses are not exceeded; g) when the loading pattern of the product within the irradiation container has been defined, dose mapping should be performed with a sufficient number of appropriate dosimeters to show the distribution of the absorbed dose within the loaded irradiation container and to show the places of minimum and maximum doses. This dose mapping should be carried out for a representative number of irradiation containers to determine the variability of the absorbed dose in the load of one container and the differences between several containers. Note: Separate dose mapping exercises should be carried out for each product or distinct category of products and each pathway to be used for processing products. h) a written standard operating procedure should be established including the following minimum items: the loading pattern of product(s) within the irradiation container; the type, number and location of routine dosimeters within one irradiation batch or within a stated period of time in the case of a continuous process; 26

any adjustments to be applied to the routine dosimeter measurements to convert them into the absorbed dose at both minimum and maximum positions; the stated minimum and maximum absorbed dose including experimentally determined errors of dosimeters; whether or not repeated treatment is acceptable; for the product concerned, the circumstances in which such repeated treatment is allowed, and the number of occasions on which it is allowed for a particular batch; in the case of electron beam irradiators electron energy, average beam current, beam width and conveyor speed should be stated with acceptable limits. Note: The stated minimum dose is that required for the intended purpose, the stated maximum dose is limited by unacceptable changes induced by irradiation in the product and/or the packaging, or imposed by official restrictions. A minimum absorbed dose of 25 kgy may be regarded as adequate for the purpose of sterilising pharmaceutical components or products which have a low initial bioburden and no radioresistant spores. Other doses may be used provided that a biological validation has been performed. 4. VALIDATION OF THE IRRADIATION PROCEDURE 4.1 Validation with regard to the irradiation procedure and dose a) with electron irradiation, if the maximum electron energy exceeds 10 MeV, it should be demonstrated that no radionuclides develop in the product; b) information derived from experimental investigations into the acceptable variation i n the loading pattern should be given; c) information should be included on the errors due to the type of dosimeters used and on the influence of their position; d) information on the relationship between the absorbed doses in the extreme positions within the load and the positions of routine dosimeters should be given. 4.2 Validation with regard to the purpose of irradiation (see section 2.b) For reduction of bioburden and/or sterilisation: a) Where appropriate, information on the bioburden of the product before irradiation should be given with data from several batches to show the usual bioburden levels and types of organisms usually present; b) data on the reduction of bioburden during the irradiation with different doses, including the minimum dose, should be given for at least 2 batches; c) an inactivation curve derived from the above data should be submitted. If the test specimen itself has a low bioburden, it should be artificially contaminated with > 107 cfu/single unit preferably with a microorganism originally occurring in the product and with a minimum D-Value of 3 kgy; 27

3AQ4a d) the bioburden limit on the product prior to irradiation should be based on data derived from a) c). In other cases, experimental results should show that the purpose of irradiation has been achieved. 4.3 Validation with regard to the quality of the product a) Information should be given about any qualitative and quantitative changes in the product, including its packaging, as a result of irradiation; Note: Methods used for quantitative determinations should be validated i n accordance with the note for guidance Validation of Analytical Procedures: Methodology. b) Information should be given about the formation of radiolysis products or other degradation or interaction products. Whenever possible, the radiolysis products should be identified; c ) the results of the studies carried out with high doses of radiation to determine the maximum dose should be given; d) as assessment of the significance of any observed changes should be included; e) information should be given about the effect of irradiation on the stability of the product and therefore stability studies should be performed on products which have received the maximum absorbed dose. Note: The relevance of any changes in the product induced by irradiation as regards quality of the product as well as health and safety of the patient should be discussed. The toxicological risks caused by products of irradiation (see section 3.3.b) should be evaluated. Safety of the irradiated product for the patient should be discussed in the expert report. 28

GLOSSARY Absorbed Dose The quantity of radiation energy imparted per unit mass of material. The unit of absorbed dose is the Gray (Gy) where 1 Gray is equivalent to absorption of 1 Joule per kilogram (J.kg- 1). Batch A defined quantity of starting material, packaging material or product processed in one process or series of processes so that it could be expected to be homogeneous. Note: To complete certain stages of manufacture, it may be necessary to divide a batch into a number of subbatches, which are later brought together to form a final homogeneous batch. In the case of continuous manufacture, the batch must correspond to a defined fraction of the production, characterised by its intended homogeneity. For control of the finished product, the following definition has been given in Directive 75/318/EEC as amended: For the control of the finished product, a batch of a proprietary medicinal product comprises all the units of a pharmaceutical form which are made from the same initial mass of material and have undergone a single series of manufacturing operations or a single sterilisation operation or, in the case of a continuous production process, all the units manufactured in a given period of time. Bioburden The total number of all viable aerobic bacteria, yeasts and moulds expressed as colony forming units (cfu) per unit or gram of product. Bulk Product Any product which has completed all processing stages up to, but not including, final packaging. Dose Mapping An exercise conducted within the irradiation equipment to determine the distribution of absorbed dose throughout a load of product or simulated product of specified density ( dummy product ) arranged in the irradiation container in a defined configuration. Dosimeter A device or system having a reproducible measurable response to radiation, which can be used to measure the absorbed dose in a given material. Dummy Product Homogeneous material of known density for filling the irradiation container for the purpose of carrying out dose distribution experiments with ionising radiation. 29

3AQ4a Finished Product A medicinal product which has undergone all stages of production including packaging. Intermediate Product Partly processed material which must undergo further manufacturing steps before it becomes a bulk product. Irradiation Container The outermost container in which the products are irradiated. Packaging Material Any material employed in the packaging of a product, excluding any outer packaging used for transportation or shipment. Packaging materials are referred to as primary or secondary according to whether or not they are intended to be in direct contact with the product. Starting Material Any substance used in the production of a product, but excluding packaging materials. 30