Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Similar documents
Recent Activities of the neutron standardization at KRISS

Recent activities in neutron standardization at NMIJ/AIST

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Recent developments in neutron metrology at the Institute for Radiological Protection and Nuclear Safety (IRSN)

Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Characterization of an 241 AmBe neutron irradiation facility by different spectrometric techniques

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

Bonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.

Neutron Metrology Activities at CIAE (2009~2010)

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Energy Response Characteristics of Several Neutron Measuring Devices Determined By Using the Scattered Neutron Calibration Fields of KAERI

Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 11 May 2007

Journal of Radiation Protection and Research

NUCL 3000/5030 Laboratory 2 Fall 2013

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Measurement of induced radioactivity in air and water for medical accelerators

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

MEASUREMENT OF THE NEUTRON EMISSION RATE WITH MANGANESE SULPHATE BATH TECHNIQUE

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

MECHANICAL ENGINEERING. Five-year M.Sc. studies School of Mechanical Engineering National Technical University of Athens

Journal of Radiation Protection and Research

A new neutron monitor for pulsed fields at high-energy accelerators

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Validation of the UFS Bonner Sphere Spectrometer and Monte Carlo Methods at the CERN-EU high energy Reference Field (CERF)

MEASUREMENT AND DETECTION OF RADIATION

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

Characterization of Large Structures & Components

Applied Nuclear Science Educational, Training & Simulation Systems

He-3 Neutron Detectors

INTERNATIONAL KEY COMPARISON OF MEASUREMENTS OF NEUTRON SOURCE EMISSION RATE ( ) CCRI(III)-K9.AmBe

THE ANNUAL EFFECTIVE DOSE FROM NATURAL RADIONUCLIDES SOIL SURFACES OF UZHGOROD AREA

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

STUDY OF NEUTRON IRRADIATION-INDUCED COLOR IN TOPAZ AT THE PULSED REACTOR IBR-2. Abstract

anti-compton BGO detector

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

Recent improvements in on-site detection and identification of radioactive and nuclear material

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination

Neutron Spectrometry in Mixed Fields: Characterisation of the RA-1 Reactor Workplace

MC simulation of a PGNAA system for on-line cement analysis

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

Major Nuclear and Radiation Physics experimental facilities in. Prepared By Dr M Tanseer Ali

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency

SCINTILLATION DETECTORS AND PM TUBES

Neutronics Experiments for ITER at JAERI/FNS

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

New methodology for source location and activity determination in preparation of repairing or decommissioning activities

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Compton suppression spectrometry

Calibration of a Whole Body Counter and In Vivo measurements for Internal Dosimetry Evaluation in Chile, Two years experience.

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

Integral Benchmark Experiments of the Japanese Evaluated Nuclear Data Library (JENDL)-3.3 for the Fusion Reactor Design

An introduction to Neutron Resonance Densitometry (Short Summary)

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

1.E Neutron Energy (MeV)

Radiation Monitoring and Measurements Presented on behalf of Lutz Moritz by

"Neutron Flux Distribution"

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

Performance Test of the Electronic Personal Neutron Dosemeter in Neutron Fields Simulating Workplaces of MOX Fuel Fabrication Facilities

*Corresponding author,

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

5) Measurement of Nuclear Radiation (1)

Acoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy

A coincidence method of thorium measurement

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

Activity determination of 88 Y by means of 4πβ(LS)-γ coincidence counting

Applications of MCBEND

SECTION 8 Part I Typical Questions

ARTICLE IN PRESS. Applied Radiation and Isotopes

Chapter 4 Scintillation Detectors

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

Chapter 11: Neutrons detectors

Fundamentals of Radionuclide Metrology

Reactor radiation skyshine calculations with TRIPOLI-4 code for Baikal-1 experiments

New irradiation zones at the CERN-PS

Investigation Of The Effects Of Variation Of Neutron Source-Detector Distance On The Emitted Neutron Dose Equivalent

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

Seaborg s Plutonium?

12/18/2016. Radioanalysis Laboratory Capabilities and Issues. Eleventh Annual Radiation Measurement Cross Calibration Workshop RMCC XI

Neutronics experiments for validation of activation and neutron transport data for fusion application at the DT neutron generator of TU Dresden

Nuclear Science and Engineering Institute, University of Missouri, USA and Sidney Kimmel Institute for the Nuclear Renaissance

Reliability and Traceability in Radiation Calibration

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

PECULIARITIES OF FORMING THE RADIATION SITUATION AT AN AREA OF NSC KIPT ACCELERATORS LOCATION

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Atoms, Radiation, and Radiation Protection

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Design of an Integrated Inspection System For Detection of Explosive and Illicit Materials

Use of phoswich detector for simultaneous monitoring of high energy photon and its applications in in vivo lung counting

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Neutron Users Club Meeting

Transcription:

Activities of the neutron standardization at the Korea Research Institute of Standards and Science (KRISS) I. Introduction The activities of neutron standardization in KRISS have been continued for last 20 years. The neutron emission rate measurement standard, and the radionuclide neutron source based fluence standards are established. Recently, we started the neutron spectrometry using Bonner Sphere Spectrometer and we plan to measure the neutron spectra at the work place of the nuclear power plant. We joined two international comparison exercises for last several years and we are willing to join future international comparisons as much as we can. II. Establishment and maintenance of neutron standards 1. Absolute measurement of Neutron Emission rate of radionuclide neutron sources Manganese Sulfate Bath was installed at KRISS in 1988 and used as a primary standard for the absolute measurement of Neutron Emission rate of radionuclide neutron sources. The diameter of the bath is 125 cm and the volume of the bath is 1.0226 10 6 cm 3. The aqueous solution of Manganese sulfate is circulated with the flow rate of ~10 cc/minute to the position of the gamma detector (NaI (Tl) crystal of 1.5" 1.5"). The counting efficiency of the system is determined using the standard 56 Mn radioisotope. The 56 Mn radioisotopes are produced by the research reactor and the specific activity is determined by 4πβγ(PPC) coincidence method, which is the KRISS primary standard. 1

The various corrections to determine the emission rate were determined by the direct measurements and the calculations based on the cross sections. But, recently, all the corrections are replaced with the MCNP calculation. Now, we can measure the neutron emission rate of the order of 10 5 /s to 10 8 /s with the uncertainties of the order of 0.7%. The neutron emission rate measurement has the traceability to the activity standards of KRISS. 2. Radionuclide source based fluence standards KRISS has the neutron irradiation room with the size of 6.7 7.6 6.4 m 3 and the neutron sources of bare 252 Cf (~10 6 n/s, ~10 8 n/s), D 2 O moderated 252 Cf, 241 Am-Be (~10 5 n/s, ~10 7 n/s) can be installed at the center of the room. The strongest source ( 252 Cf with the neutron emission rate of ~10 8 n/s) can be controlled remotely. The moving arms for the calibration and test of the neutron detector can be moved about 2 m (the minimum distance from the source is ~20 cm). The neutron spectral fluence is calculated by MCNP5 calculation very carefully, including all the structures inside the room. The wallscattering is about 10 % at the 1 m distance from the source. This year, we plan to measure the neutron spectral fluence using Bonner Sphere spectrometer. This standard has the traceability to the neutron emission rate standards of KRISS. 3. Neutron Spectrometry using multi-sphere system for the neutron dosimetry (Planned) Recently, KRISS constructed the multi-sphere system for the neutron spectrometry (Bonner Sphere spectrometer), manufactured by Centronic Ltd., UK. The spheres are made of high density polyethylene and He-3 proportional counter (SP9 from Centronic Ltd., UK) is used as a thermal neutron detector. 2

The Bonner Sphere set has 10 spheres of 3", 3.5", 4", 4.5", 5", 6", 7", 9", 10", and 12" diameter and originally designed by PTB, Braunschweig. The response matrix is calculated by the small modification of original PTB BS's response matrix, considering the difference of the density and the size of the spheres. The normalization of the response matrix is determined by the measurement of the neutron spectrum of 252 Cf source. We plan to start measuring the neutron spectra of the work place field of nuclear power plant. III. Dissemination of neutron standards Based on the neutron standards established in KRISS, - we calibrate the neutron emission rate of the radionuclide neutron source of the emission rate of the order of 10 5 n/s to 10 8 n/s with the uncertainties of ~0.7 %. In average, we calibrate the neutron source once a year. - we calibrate about 30 neutron survey meters per year in average. IV. International Comparison - the comparison of emission rate, CCRI(III)-K9.AmBe. - the comparison of neutron survey meter calibrations, EUROMET.RI(III)-S1. 3

V. Other activities and plans - We are now planning to measure the mono-energetic neutron fluence using the 1.7MV Tandem accelerator which is located in Korea Institute of Geoscience and Mineral Resources(KIGAM) nearby KRISS. - We are planning to introduce the neutron spectrometry for the fast neutrons using liquid scintillation counter and spherical proportional counter. - Long counter will be studied and calibrated for the neutron fluence measurement. - TEPC was constructed several years ago and it will be revived to measure neutron absorbed dose. - Neutron transport code (MCNP4C and MCNP5), general Monte-Carlo simulation(geant4) could be run to study the neutron detectors, to design the shielding and various structures of the neutron irradiators, to determine the characteristics of the neutron irradiation facility, to determine various correction parameters of the measurement, and eventually to calculate basic parameters for the neutrons. Staff Members Two researchers are fully involved for the neutron standardization. New member will join in this year. Facilities - Radioactive neutron sources two 252 Cf source : the emission rates of 2.05 10 8 n/s and 1.95 10 6 n/s two 241 Am-Be source : the emission rate of 1.229 10 7 n/s and 2.325 10 5 n/s - Low background neutron irradiation room : size of 6.7 7.6 6.4 m 3 - Neutron detectors Long counter with one He-3 proportional counter and one BF 3 proportional counter two REM counter (EG&G Ortec LB123), two H 2 proportional counter Liquid scintillation detector (BC501a) 4

two BF 3 proportional counter Bonner sphere system with 10 spheres and four He-3 detector Manganese Sulfate bath system Publications and Communications International - Development of a Polyethylene Proportional Counter and Cf-252 Neutron Absorbed Dose Measurement, K.-O. Choi et al, International Sym. on Radiation Safety and Detection Technology, 2003, Tsukuba, Japan. - An Experience in the KRISS Cf-252 Source Calibration for Its Neutron Emission Rate Measurement, K.O.Choi et al, American Nuclear Society 2002 Annual Meeting. - "CARE for NPPs in Korea and RMS of NPPs in Illinois, USA", S.T. Hwang, 2000 U.S.-Korea Conference (UKC) on Science, Technology, Entrepreneurship, and Leadership", 2000. - Correction equations of coincidence summing using 75 Se radionuclide in the efficiency of HPGe detector, Y. Lee et al, Jour. of Radioanalytical and Nuclear Chemistry, 242 (1999) 105. - Impurity correction factor of MnSO 4 compound for the determination of neutron emission rate on the manganese bath method, K.-O. Choi et al, Jour. of radioanalytical and Nuclear Chemistry, 239 (1999) 605. - Impurity Correction factor on MnSo4 compound for the determination of neutron emission rate on the manganese bath method, K. O. Choi et al, Aisa-Pacific Symposium on Radiochemistry '97 and 41st Symposium on Radiochemistry, 1997. - Simulation of Prompt Gamma-ray Activation Analysis for the Determination of NaCl Concentration in concerts, W.S.Kim Proceed. the 5th Asian Symposium on research Reactors, 1 (1996)355. - Collisional processes in muon catalyzed fusion as studied by the classical collision theory, G. P. Lee et al, Jour. of Radioanalytical & nuclear chemistry, 178(1994)121 - Neutron Depth Profiling:Overview and Description of NIST Facilities, R. G. Downing et al, Jour. of Research of NIST 98 (1993) 109. - The New Cold Neutron Depth Profiling Instrument At NIST G.P. Lee et al, Jour. of radioanalytical and Nuclear chemistry 160 (1992) 315. - Ion Beam Induced Emissions from Solid Europium Compounds, G.P. Lee et al, J. of radioanalytical and nuclear chemistry articles, 160 (1992) 203. 5

- Spectroscopic studies of Sb3 + color centers in alkali halide single crystals, K.O. Choi, Jour. Chem. Phys. 94 (1991) 6420. - Determination of the Leachability Index of 137 Cs from Cement Solidified Radioactive Waste, E.H. Hwang et al, Jour. of Radioanalytical & Nuclear Chem. 140 (1990) 155. - Determination of the Ratio of the Hydrogen and Manganese Absorption Cross Sections by the Manganese Bath Technique, S.T. Hwang et al, Jour. of Radioanalytical and Nuclear Chem. 139 (1990) 37. - An Experience in the KRISS Cf-252 Source Calibration for Its Neutron Emission Rate Measurement, S.T. Hwang, Transactions of the American Nuclear Society, 60(1989)378. - Absolute neutron emission rate measurement of a 252 Cf source by the manganese sulfate bath method, S.T. Hwang et al, Nucl. Instrum. and Meth. A273 (1988) 381. - Measurement of Neutron Emission Rate of Cf-252 Source by the Comparative, S.T. Hwang, Japanese Radiation 13(1987)138. - Saturation Manganese Activity Measurement by Circulated Manganse Sulphate Bath Technique, S.T. Hwang, 32nd Health physics soc. salt lake city, 1987. Domestic - Neutron spectroscopy to Cf-252 and D2Omoderated Cf-252 sources measured by means of a Bonner sphere spectrometry, K. O. Choi et al, Bulletin of KOREAN PHYS SOC 22(2004)374. - Study of Characteristics of BC501a neutron detectors using Cf-252 neutron source, H. Park et al, Bulletin of the Korean Physical Society, 21(2003)359. - Advanced Technology Trends in Development of Land-Mine Detection Systems, S.T. Hwang, J. of the Korean nuclear society 33(2001)349. - The anisotropy measurement of 241Am-Be source, K-O Choi, Bulletin of the Korean Physical Society 19(2000)306. - NOAA's Response Plan for Nuclear Emergencies, S.T. Hwang, The proceedings of the conference of Korean Association for the radiation protection, 25(2000) 115. - Measurement of 252Cf fission neutron spectrum by means of a 3He semiconductor spectrometer, K. O. Choi et al, Korean Physical Society, 1996. - Calculation of the response function for 3He sandwich-type silicon surface-barrier detector, W. S. Kim, Bulletin of the Korean Physical Society 14(1996). - "Simulation of optimum neutron field for Na(n,r)24Na reaction", W.S. Kim, Bulletin of the Korean Physical Society, 13(1995)2. 6

- Calculation of the an-isotropic factor of 252Cf neutron source, W.S. Kim et al, J. of Korean Nuclear Society, 1994. - A MCNP response test of 5"x5" Bc501 liquid scintillator, W.S. Kim et al, Korean Physical Society, 1994. - Gamma Spectroscopy for the thermal neutron capture nuclear reaction, W.S. Kim, J. of Korean Society of Analytical Science, 20 (1994). - Neutron fluence measurement with Long counter, K. O. Choi, Korean Society of Analytical Science, 1993. - Characteristics of 6Li neutron spectrometer, S.H. Choi et al, J. of Korean Society of Analytical Science, 5 (1992) 57. - 10 B Surface Contamination for CdTe by the Cold Neutron Depth Profiling Technique, S.T. Hwang, J. of Korean Society of Analytical Science, 4 (1991) 241. - Neutron measurement using 3He neutron spectrometer, G.P Lee et al, J. of Korean Society of Analytical Science, 4 (1991) 69. - Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources, K.-O. Choi, The proceedings of the conference of Korean Association for the radiation protection, 14(1989)70. - Radioactive Neutron Source Calibration at the Korea Standards Research Institute, S. T. Hwang, The proceedings of the conference of Korean Association for the radiation protection, 10(1985) 67. 7