Commercial Documentation Wind Turbine Generator Systems Hz and 60 Hz

Similar documents
Estimated Sound Power Level of the ENERCON E-92 Operational Mode I (Data Sheet)

Appendix 4A Candidate Turbine Manufacturer Data

ANNEXE L COURBES D ÉMISSION ACOUSTIQUE DES ÉOLIENNES CONSIDÉRÉES

Sound Power Level. of the ENERCON E-82 E2. Operational Mode I. (Data Sheet)

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 5: Determination of the noise emission

Document No 10/6298/001/GLA/O/R/001 Issue : B2. Kingspan Renewables Ltd. Kingspan KW6 Wind Turbine Noise Performance Test

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

ISO INTERNATIONAL STANDARD

ISO 3741 INTERNATIONAL STANDARD

ISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method

ISO 6395 INTERNATIONAL STANDARD. Earth-moving machinery Determination of sound power level Dynamic test conditions

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Geographic information Metadata Part 2: Extensions for imagery and gridded data

Dual N-channel field-effect transistor. Two N-channel symmetrical junction field-effect transistors in a SOT363 package.

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

Part 2: Methods for special reverberation test rooms

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Meteorology Wind measurements Part 1: Wind tunnel test methods for rotating anemometer performance

ISO INTERNATIONAL STANDARD. Reference radiation fields Simulated workplace neutron fields Part 1: Characteristics and methods of production

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Sample preparation Dispersing procedures for powders in liquids

ISO INTERNATIONAL STANDARD. Geographic information Spatial referencing by coordinates

ISO INTERNATIONAL STANDARD. Surface chemical analysis X-ray photoelectron spectroscopy Repeatability and constancy of intensity scale

Determination of particle size distribution Single particle light interaction methods. Part 4:

IECRE OPERATIONAL DOCUMENT

ISO 385 INTERNATIONAL STANDARD. Laboratory glassware Burettes. Verrerie de laboratoire Burettes. First edition

ISO INTERNATIONAL STANDARD. Geographic information Spatial referencing by coordinates Part 2: Extension for parametric values

PSMN004-60B. N-channel TrenchMOS SiliconMAX standard level FET. High frequency computer motherboard DC-to-DC convertors

ISO INTERNATIONAL STANDARD. Mechanical vibration and shock Coupling forces at the man-machine interface for hand-transmitted vibration

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

N-channel TrenchMOS standard level FET. High noise immunity due to high gate threshold voltage

The 74LV08 provides a quad 2-input AND function.

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

N-channel TrenchMOS logic level FET

ISO INTERNATIONAL STANDARD

PSMN B. N-channel TrenchMOS SiliconMAX standard level FET. High frequency computer motherboard DC-to-DC convertors

ISO INTERNATIONAL STANDARD. Ships and marine technology Marine wind vane and anemometers

ISO INTERNATIONAL STANDARD

ISO 2575 INTERNATIONAL STANDARD. Road vehicles Symbols for controls, indicators and tell-tales

ISO INTERNATIONAL STANDARD. Water quality Determination of dissolved bromate Method by liquid chromatography of ions

N-channel TrenchMOS standard level FET. Higher operating power due to low thermal resistance Low conduction losses due to low on-state resistance

Metallic materials Knoop hardness test. Part 1: Test method. Matériaux métalliques Essai de dureté Knoop Partie 1: Méthode d'essai

INTERNATIONAL STANDARD

74HC2G16; 74HCT2G16. The 74HC2G16; 74HCT2G16 is a high-speed Si-gate CMOS device. The 74HC2G16; 74HCT2G16 provides two buffers.

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

N-channel enhancement mode Field-Effect Transistor (FET) in a small SOT23 (TO-236AB) Surface-Mounted Device (SMD) plastic package using

ISO INTERNATIONAL STANDARD

ISO 3497 INTERNATIONAL STANDARD. Metallic coatings Measurement of coating thickness X-ray spectrometric methods

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

ISO INTERNATIONAL STANDARD. Plastics Determination of thermal conductivity and thermal diffusivity Part 3: Temperature wave analysis method

BF556A; BF556B; BF556C

Part 5: Total stations

ISO 3071 INTERNATIONAL STANDARD. Textiles Determination of ph of aqueous extract. Textiles Détermination du ph de l'extrait aqueux

N-channel TrenchMOS standard level FET. Higher operating power due to low thermal resistance Low conduction losses due to low on-state resistance

ISO INTERNATIONAL STANDARD. Thermal bridges in building construction Linear thermal transmittance Simplified methods and default values

This document is a preview generated by EVS

PHB108NQ03LT. N-channel TrenchMOS logic level FET

74HC30; 74HCT General description. 2. Features and benefits. 3. Ordering information. 8-input NAND gate

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

Passivated ultra sensitive gate thyristor in a SOT54 plastic package. Earth leakage circuit breakers or Ground Fault Circuit Interrupters (GFCI)

ISO INTERNATIONAL STANDARD. Rolling bearings Linear motion rolling bearings Part 2: Static load ratings

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

ISO INTERNATIONAL STANDARD. Thermal insulation for building equipment and industrial installations Calculation rules

Achieving Reliable Energy Production During Winter Months

N-channel TrenchMOS ultra low level FET. Higher operating power due to low thermal resistance Interfaces directly with low voltage gate drivers

4-bit magnitude comparator

INTERNATIONAL STANDARD

This document is a preview generated by EVS

65 V, 100 ma NPN/PNP general-purpose transistor. Table 1. Product overview Type number Package NPN/NPN PNP/PNP Nexperia JEITA

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of volatile organic compound (VOC) content Part 1: Difference method

Silicon N-channel dual gate MOS-FET IMPORTANT NOTICE. use

PHP110NQ08T. N-channel TrenchMOS standard level FET

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

ISO Representation of results of particle size analysis Adjustment of an experimental curve to a reference model

INTERNATIONAL STANDARD

2-input AND gate with open-drain output. The 74AHC1G09 is a high-speed Si-gate CMOS device.

Low-power dual Schmitt trigger inverter

Big Thunder Wind Park, Draft Environmental Noise Impact Report

PRELIMINARY WIND RESOURCE ASSESSMENT OF WINDYGATES FIRST NATIONS PROJECT. Department of Innovation, Energy and Mines Contact. Rick Halas Document No

ISO Water quality Measurement of polonium 210 activity concentration in water by alpha spectrometry

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plastics Determination of hardness Part 1: Ball indentation method

ISO INTERNATIONAL STANDARD

74LVC1G79-Q100. Single D-type flip-flop; positive-edge trigger. The 74LVC1G79_Q100 provides a single positive-edge triggered D-type flip-flop.

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods. Analyse granulométrique Méthodes par diffraction laser

ISO INTERNATIONAL STANDARD. Geographic information Metadata Part 2: Extensions for imagery and gridded data

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD IULTCS/IUC 8:2

7-stage binary ripple counter

60 V, 0.3 A N-channel Trench MOSFET

Transcription:

GE Energy Commercial Documentation Wind Turbine Generator Systems 2.75-103 - 50 Hz and 60 Hz Product Acoustic Specifications Normal Operation according to IEC 61400-11 imagination at work 2010 GE Company. All rights reserved.

GE Energy Gepower.com Visit us at www.gewindenergy.com All technical data is subject to change in line with ongoing technical development! Copyright and patent rights This document is to be treated confidentially. It may only be made accessible to authorized persons. It may only be made available to third parties with the expressed written consent of General Electric Company. All documents are copyrighted within the meaning of the Copyright Act. The transmission and reproduction of the documents, also in extracts, as well as the exploitation and communication of the contents are not allowed without express written consent. Contraventions are liable to prosecution and compensation for damage. We reserve all rights for the exercise of commercial patent rights. 2010 General Electric Company. All rights reserved. GE and are trademarks and service marks of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies. imagination at work 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc.

GE Energy Product Acoustic Specifications Table of Contents 1 Introduction...5 2 2.75-103 Product Normal Operation Acoustic Performance...6 2.1 2.75-103 Normal Operation Calculated Apparent Sound Power Level...6 2.2 2.75-103 Normal Operation Calculated Tonality...7 3 2.75-103 Product Aadditional Information...8 3.1 2.75-103 Wind Speeds at Reference Height extrapolated to Hub Height....8 3.2 2.75-103 Testing Uncertainty and Product Variation per IEC/TS 61400-14 Standard...8 3.3 IEC 61400-11 and IEC 61400-14/TS Terminology...9 CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc

GE Energy Product Acoustic Specifications 1 Introduction This document defines the noise emission characteristics of the wind turbine series 2.75-103, 50 Hz and 60 Hz versions, equipped with 103 m rotor diameter (GE 50.2 type blade) operating in normal operation (NO). General Electric continuously verifies specifications with measurements, including those performed by independent institutes. The calculated apparent sound power level L WA,k as function of v 10m (reference wind speed 10 m above ground level) is provided for normal operation (NO) over cut-in to cut-out wind speed range. The corresponding wind speeds at hub height v HH are provided assuming different standard hub heights and a logarithmic wind profile. If a wind turbine noise performance test is to be carried out, it needs to be done in accordance with both IEC 61400-11 and GE s Machine noise performance test reference guidelines. Paragraph 2 provides nominal calculated acoustic performance for: 2.75-103 (50 & 60 Hz) calculated apparent sound power level L WA,k as function of v 10m and at 95% rated electrical power per IEC 61400-11. 2.75-103 (50 & 60 Hz) tonality level ΔL a, k per IEC 61400-11 Paragraph 3 provides 2.75-103 acoustic performances additional data: The wind speeds at reference height v 10m extrapolated to v HH (wind speed at hub height) Uncertainty information IEC 61400-11 and IEC/TS 61400-14 additional information CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc 5/10

GE Energy Product Acoustic Specifications 2 2.75-103 Product Normal Operation Acoustic Performance 2.1 2.75-103 Normal Operation Calculated Apparent Sound Power Level The Table 1 provides nominal acoustic specifications for 2.75-103 equipped with 103 m rotor diameter (GE 50.2 type blade) and 100 m hub height as function of wind speed v 10m (reference wind speed 10 m above ground level), operating at normal operation (NO) per IEC 61400-11 standard and GE s Machine noise performance test reference guidelines: Wind speed at v10m [m/s] LWA,k * Apparent sound power level [db] 5 97.1 6 102.2 6.5 104.4 7 105.0 8 105.0 9 105.0 Table 1: Normal operations, 2.75-103 wind turbine, 50.2 m blades (103 m rotor), 100 m hub height, apparent sound power level at wind speed v10m. At wind speeds lower than 5 m/s the sound power levels decreases, and may get so low that the wind turbine noise becomes indistinguishable from the background noise. For a conservative calculation the data at 5 m/s may be used. At wind speeds above 9 m/s turbine has reached rated power and the increasing pitch angle decreases the noise level. For a conservative calculation the data at 9 m/s may be used. The nominal acoustic performances for 2.75-103, 50 Hz and 60 Hz versions, equipped with 103 m rotor diameter (GE 50.2 type blade) operating in normal operation (NO), specified at 95 % rated electrical power: The calculated apparent sound power level is L WA,k 105.0dBA. * LWA,k indicates apparent sound power level per IEC-61400-11 standard measured in db, A-weighted 10 base logarithmic value of apparent sound power relative to reference sound power of 10-12 W. CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 6/10 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc

GE Energy Product Acoustic Specifications 2.2 2.75-103 Normal Operation Calculated Tonality The nominal acoustic performance for 2.75-103, 50 Hz and 60 Hz versions, equipped with 103 m rotor diameter (GE 50.2 type blade) operating in normal operation (NO), specified at reference ground measuring distance R o measurement position #1 per both IEC 61400-11 and GE s Machine noise performance test reference guidelines: Tonal audibility ΔL a, k < 4 db. CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc 7/10

GE Energy Product Acoustic Specifications 3 2.75-103 Product Additional Information 3.1 2.75-103 Wind Speeds at Reference Height extrapolated to Hub Height The wind speeds v 10m at reference height (10 m above ground) can be extrapolated from v 10m to v HH (wind speed at hub height), per IEC 61400-01, assuming surface roughness of z 0, ref = 0.05 m typical average condition and using: Meaning wind speeds from Table 1 can be extrapolated to 100 m hub height using v HH = v 10m * 1.43 and to 85 m hub height using v HH = v 10m * 1.40 per Table 2. Wind speed at 10 m reference height v10m [m/s] Wind speed at 85 m hub height VHH=85 [m/s] Wind speed at 100 m hub height vhh=100 [m/s] 5 7.0 7.2 6 8.4 8.6 6.5 9.1 9.3 7 9.8 10.0 8 11.2 11.5 9 12.6 12.9 Table 2: Relation between wind speed at reference height v10m and wind speeds at different hub heights vhh for z0, ref = 0.05 m 3.2 2.75-103 Testing Uncertainty and Product Variation per IEC/TS 61400-14 Per IEC/TS 61400-14, L WAd is the maximum apparent sound power level resulting from n measurements performed according to IEC 61400-11 standard for 95 % confidence level: L WAd = L WA + K, where L WA is the mean apparent sound power level from n IEC 61400-11 testing reports and K = 1,645 σ T. The testing standard deviation values σ T, σ R and σ P for measured apparent sound power level are described by IEC/TS 61400-14, where σ T is the total standard deviation, σ P is the standard deviation for product variation and σ R is the standard deviation for test reproducibility. Assuming σ R < 0.8 db and σ P < 0.8 db typical values, leads to calculated K < 2 db for 95 % confidence level. CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 8/10 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc

GE Energy Product Acoustic Specifications 3.3 IEC 61400-11 and IEC/TS 61400-14 Terminology L WA,K is wind turbine apparent sound power level (referenced to 10-12 W) measured with A- weighting as function of reference wind speed v 10m. Derived from multiple measurement reports per IEC 61400-11, it is considered as a mean value σ P is the product variation i.e. the 2.75-103 unit-to-unit product variation; typically < 0.8dB σ R is the overall measurement testing reproducibility as defined per IEC 61400-11; typically < 1dB with adequate measurement conditions and sufficient amount of data samples σ T is the total standard deviation combining both σ P and σ R K = 1,645 σ T is defined per IEC/TS 61400-14 for 95 % confidence level R o is the ground measuring distance from the wind turbine tower axis per IEC 61400-11 Δ La, k is the audibility according to IEC 61400-11, described as potentially audible narrow band sound CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc 9/10

GE Energy Product Acoustic Specifications References: IEC 61400-1, Wind turbines part 1: Design requirements, ed. 3, 2005-08 IEC 61400-11, wind turbine generator systems part 11: Acoustic noise measurement techniques, ed. 2.1, 2006-11 IEC/TS 61400-14, Wind turbines part 14: Declaration of apparent sound power level and tonality values, ed. 1, 2005-03 MNPT Machine Noise Performance Test, Technical documentation, GE 2007 CONFIDENTIAL - Proprietary Information. DO NOT COPY without written consent from GE Company. UNCONTROLLED when printed or transmitted electronically. 2010 General Electric Company. All rights reserved 10/10 2.75-103_xxHz_SCD_allComp_NO_IECxxxxxx.ENxxx.00.doc

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 1 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] REpower Systems SE Überseering 10 22297 Hamburg Germany Phone.: +49-40 - 5555090-0 Fax: +49-40 - 5555090-3999 www.repower.de Copyright 2011 REpower Systems SE All rights reserved. Disclaimer Protection Notice DIN ISO 16016: The reproduction, distribution and utilization of this document as well as the communication of its contents to others without explicit authorization in writing of REpower Systems SE is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. Please ensure to use the applicable specifications in their latest versions. Images do not necessarily reflect the exact scope of supply and are subject to technical alterations at any time. Please note that this document can not necessarily correspond with the projectspecific requirements. Possible work procedures shown in this product description comply with German and the REpower s own safety provisions and regulations. The national laws of other countries may provide for further safety specifications. It is essential that all precautionary measures, both project- and country-specific, be strictly complied with. It is the duty of each customer to inform itself, implement and observe these measures. The applicability and validity of the relevant legal and/or contractual provisions, the technical guidelines, DIN standards and other comparable regulations is not excluded by the contents or demonstrations contained in product description. Moreover these provisions and regulations shall continue to apply without any limitation. All information contained in this product description are subject to change at any time without notice or approval by the customer. REpower Systems SE assumes no liability for any errors or omissions in the content of this product description. Legal claims against REpower Systems SE based on damage caused by the use or non-use of the information offered here or the use of erroneous or incomplete information are excluded. All brands or product names mentioned in this document are the property of their respective holders. Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 2 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] Table of Contents Applicable Documents... 4 List of Abbreviations and Units... 4 1 Introduction... 5 2 Conditions for guarantee and measurement of power curve and sound power level 5 2.1 General information... 5 2.2 Conditions for power curve guarantee and measurement... 5 2.3 Conditions for sound power level guarantee and measurement... 6 3 Guaranteed electrical power curve and sound power level... 7 3.1 Sound Power Level according to IEC for different Hub Heights... 8 3.2 Sound Power Level according to FGW Guideline at 95% of rated power... 8 4 Calculated electrical power curve (for information only)... 9 Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 3 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] Applicable Documents The following documents are mentioned within this document without being subject matter of this product description. Title Document no. * Depending on the project specific selection of REpower products the respective documents will appear in each case as separate amendments of the contract in their actual version. List of Abbreviations and Units Abbreviation/Unit cp ct FGW IEC WEC Description Power coefficient Thrust coefficient Fördergesellschaft Windenergie e.v. International Electrotechnical Commission Wind Energy Converter (equal to Wind Turbine Generator System [WTGS]) Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 4 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] 1 Introduction This document shows the guaranteed power curve and sound power level of the REpower 3.2M114 and the corresponding guarantee and measurement conditions. 2 Conditions for guarantee and measurement of power curve and sound power level 2.1 General information Rotor diameter: Air density: Cut in wind speed: Cut out wind speed: Wind speed at hub height: Blades: 114.0 m 1.225 kg/m³ approx. 3.0 m/s 22.0 m/s 10 minutes mean values clean, no ice/snow formation 2.2 Conditions for power curve guarantee and measurement Verification according to IEC 61400-12-1: 2005 1,2 Turbulence intensity: 6 to 12 % Terrain: not complex according to IEC 61400-12-1: 2005 1 Vertical wind shear coefficient (measured between hub height and hub height minus rotor diameter divided by 2): 0.3 Air density at location (10 minutes mean value): 1.13 kg/m³ Temperature range: acc. to related Standard Conditions of use Anemometer type: Thies First Class/ Thies First Class Advanced Voltage level for measurement: 660 V / 950V V (50Hz) 1 For obstacle assessment according to 61400-12-1: 2005 Annex A.2 the following condition applies: To determine significant obstacles the procedure Power Performance Measurement Procedure Version 5, December 2009 chapter 3.9 has to be followed. In addition no obstacles with a height greater than 1/3 of the distance between the ground and the lower blade tip shall exist in the measurement sector within 0-4 rotor diameters of the WEC or met mast. 2 Valid for active power set points Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 5 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] G WEC (incl. auxiliary power) LV/MV Transformer M Measurement device P Grid Arrangement of a measuring unit for the power curve measurement of a REpower 3.2M114 2.3 Conditions for sound power level guarantee and measurement Verification according to IEC 61400-11: 2002 + A1: 2006 3 Roughness length (average peak): 0.05 m 3 Method 1, as outlined in section 7.3 of the IEC standard 61400-11 Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 6 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] 3 Guaranteed electrical power curve and sound power level 4 The sound power level guaranteed by REpower includes a measurement uncertainty of approx. 1 db(a). REpower warrants that there is no tonal audibility > 0 db 5. The guaranteed electrical power curve of the REpower 3.2M114 is applicable at the mediumvoltage side of the transformer and includes the transformer losses. Wind speed v [m/s] 6 Power P [kw] Sound power level L WA [db(a)] 7 Thrust coefficient ct [-] Power coefficient cp [-] 3 18-1.05 0.107 4 144-0.85 0.360 5 319-0.80 0.408 6 590 99.4 0.80 0.437 7 969 102.2 0.80 0.452 8 1460 104.7 0.80 0.456 9 2017 105.2 0.72 0.443 10 2576 105.2 0.64 0.412 11 3009 105.2 0.57 0.362 12 3170 104.9 0.40 0.293 13 3170 104.8 0.30 0.231 14 3170 104.8 0.24 0.185 15 3170 104.8 0.19 0.150 16 3170 104.8 0.16 0.124 17 3170 104.8 0.13 0.103 18 3170 104.8 0.11 0.087 19 3170 104.8 0.10 0.074 20 3170 104.8 0.08 0.063 21 3170 104.8 0.07 0.055 22 3170 104.8 0.06 0.048 4 Valid for unrestricted operation only. During sound reduced operation modes different power and sound levels are effective. 5 Valid for V10 6m/s 6 Wind speed at hub height 7 Sound power level at hub height Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 7 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] 3.1 Sound Power Level according to IEC for different Hub Heights HH* V 8 10 [m/s] 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 91-93m L 9 WA [db(a)] 98.4 102.5 105.0 105.2 105.1 104.8 104.8 104.8 120-123m L 9 WA [db(a)] 99.1 103.1 105.1 105.2 105.0 104.8 104.8 104.8 140-143m L 9 WA [db(a)] 99.4 103.5 105.2 105.2 104.9 104.8 104.8 104.8 * Hub height depending on foundation design All sound power levels above are based on wind speeds of v 10 at 10 m height. The data of the noise level are based on the requirements of the IEC 61400-11 : 2002 + A1 : 2006 The calculation of the wind speed in 10m height is based on a roughness length of 0.05m. 3.2 Sound Power Level according to FGW Guideline at 95% of rated power The sound power level measured according to the Technische Richtlinie für Windenergieanlagen Teil 1: Rev. 18 der FGW at 95% of the rated power is independent of the hub height: L WA, 95% = 105.2 db(a) 8 Wind speed in a height of 10 meters 9 Sound power level at hub height Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 8 of 9

Power Curve & Sound Power Level REpower 3.2M114 [3.2M/114/50Hz] 4 Calculated electrical power curve (for information only) The calculated electrical power curve of the REpower 3.2M114 is a theoretical one which is applicable at the low-voltage side of the transformer and does not include the transformer losses. It has been derived from the guaranteed electrical power curve in chapter 2 using typical operation conditions of the electrical system. The calculated electrical power curve is for informative purposes only and is not content of the guaranteed electrical power curve. The values of the calculated electrical power curve are a non-binding additional information. No rights or duties for REpower Systems SE result from the values given in this chapter. Legal claims against REpower Systems SE for any costs incurred and/or damages suffered (including direct, indirect, consequential damage or damages, as well as loss of income or profits) caused by the use or non-use of the information offered here or the use of erroneous or incomplete information are excluded. Wind speed Power Thrust coefficient Power coefficient v [m/s] 10 P [kw] ct [-] cp [-] 3 27 1.05 0.160 4 151 0.85 0.377 5 327 0.80 0.418 6 598 0.80 0.443 7 978 0.80 0.456 8 1471 0.80 0.460 9 2031 0.72 0.446 10 2594 0.64 0.415 11 3033 0.57 0.364 12 3200 0.40 0.296 13 3200 0.30 0.233 14 3200 0.24 0.187 15 3200 0.19 0.152 16 3200 0.16 0.125 17 3200 0.13 0.104 18 3200 0.11 0.088 19 3200 0.10 0.075 20 3200 0.08 0.064 21 3200 0.07 0.055 22 3200 0.06 0.048 10 Wind speed at hub height Document-No.: SD-3.2-WT.PC.00-B-A-EN Page 9 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 1 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] REpower Systems SE Überseering 10 22297 Hamburg Germany Phone.: +49-40 - 5555090-0 Fax: +49-40 - 5555090-3999 www.repower.de Copyright 2011 REpower Systems SE All rights reserved. Disclaimer Protection Notice DIN ISO 16016: The reproduction, distribution and utilization of this document as well as the communication of its contents to others without explicit authorization in writing of REpower Systems SE is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. Please ensure to use the applicable specifications in their latest versions. Images do not necessarily reflect the exact scope of supply and are subject to technical alterations at any time. Please note that this document can not necessarily correspond with the projectspecific requirements. Possible work procedures shown in this product description comply with German and the REpower s own safety provisions and regulations. The national laws of other countries may provide for further safety specifications. It is essential that all precautionary measures, both project- and country-specific, be strictly complied with. It is the duty of each customer to inform itself, implement and observe these measures. The applicability and validity of the relevant legal and/or contractual provisions, the technical guidelines, DIN standards and other comparable regulations is not excluded by the contents or demonstrations contained in product description. Moreover these provisions and regulations shall continue to apply without any limitation. All information contained in this product description are subject to change at any time without notice or approval by the customer. REpower Systems SE assumes no liability for any errors or omissions in the content of this product description. Legal claims against REpower Systems SE based on damage caused by the use or non-use of the information offered here or the use of erroneous or incomplete information are excluded. All brands or product names mentioned in this document are the property of their respective holders. Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 2 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] Table of Contents Applicable Documents... 4 List of Abbreviations and Units... 4 1 Introduction... 5 2 Conditions for guarantee and measurement of power curve and sound power level 5 2.1 General information... 5 2.2 Conditions for power curve guarantee and measurement... 5 2.3 Conditions for sound power level guarantee and measurement... 6 3 Guaranteed electrical power curve and sound power level... 7 3.1 Sound Power Level according to IEC for different Hub Heights... 8 3.2 Sound Power Level according to FGW Guideline at 95% of rated power... 8 4 Calculated electrical power curve (for information only)... 9 Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 3 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] Applicable Documents The following documents are mentioned within this document without being subject matter of this product description. Title Document no. * Depending on the project specific selection of REpower products the respective documents will appear in each case as separate amendments of the contract in their actual version. List of Abbreviations and Units Abbreviation/Unit cp ct FGW IEC WEC Description Power coefficient Thrust coefficient Fördergesellschaft Windenergie e.v. International Electrotechnical Commission Wind Energy Converter (equal to Wind Turbine Generator System [WTGS]) Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 4 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] 1 Introduction This document shows the guaranteed power curve and sound power level of the REpower 3.4M104 and the corresponding guarantee and measurement conditions. 2 Conditions for guarantee and measurement of power curve and sound power level 2.1 General information Rotor diameter: Air density: Cut in wind speed: Cut out wind speed: Wind speed at hub height: Blades: 104 m 1.225 kg/m³ 3.5 m/s 25.0 m/s 10 minute mean values clean, no ice/snow formation 2.2 Conditions for power curve guarantee and measurement Verification according to IEC 61400-12-1: 2005 1,2 Turbulence intensity: 6 to 12 % Terrain: not complex according to IEC 61400-12-1: 2005 1 Vertical wind shear coefficient (measured between hub height and hub height minus rotor diameter divided by 2): 0.3 Air density at location (10 minutes mean value): 1.13 kg/m³ Temperature range: acc. to related Standard Conditions of use Anemometer type: Thies First Class/ Thies First Class Advanced Voltage level for measurement: 660 V / 950V V (50Hz) 1 For obstacle assessment according to 61400-12-1: 2005 Annex A.2 the following condition applies: To determine significant obstacles the procedure Power Performance Measurement Procedure Version 5, December 2009 chapter 3.9 has to be followed. In addition no obstacles with a height greater than 1/3 of the distance between the ground and the lower blade tip shall exist in the measurement sector within 0-4 rotor diameters of the WEC or met mast. 2 Valid for active power set points Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 5 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] G WEC (incl. auxiliary power) LV/MV Transformer M Measurement device P Grid Arrangement of a measuring unit for the power curve measurement of a REpower 3.4M104 2.3 Conditions for sound power level guarantee and measurement Verification according to IEC 61400-11: 2002 + A1: 2006 3 Roughness length (average peak): 0.05 m 3 Method 1, as outlined in section 7.3 of the IEC standard 61400-11 Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 6 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] 3 Guaranteed electrical power curve and sound power level 4 The sound power level guaranteed by REpower includes a measurement uncertainty of approx. 1 db(a). REpower warrants that there is no tonal audibility > 0 db 5. The guaranteed electrical power curve of the REpower 3.4M104 is applicable at the mediumvoltage side of the transformer and includes the transformer losses Wind speed v [m/s] 6 Power P [kw] Sound Power Level L WA [db(a)] 7 Thrust coefficient ct [-] Power coefficient cp [-] 3.5 28-1.10 0.125 4 87-0.91 0.261 5 246-0.79 0.378 6 471-0.76 0.419 7 783 100.2 0.76 0.439 8 1209 102.9 0.76 0.454 9 1733 104.6 0.76 0.457 10 2293 105.4 0.71 0.441 11 2839 105.6 0.66 0.410 12 3269 105.3 0.57 0.364 13 3340 105.0 0.40 0.292 14 3370 104.8 0.31 0.236 15 3370 104.8 0.25 0.192 16 3370 104.8 0.20 0.158 17 3370 104.8 0.17 0.132 18 3370 104.8 0.14 0.111 19 3370 104.8 0.12 0.094 20 3370 104.8 0.11 0.081 21 3370 104.8 0.09 0.070 22 3370 104.8 0.08 0.061 23 3370 104.8 0.07 0.053 24 3370 104.8 0.06 0.047 25 3370 104.8 0.06 0.041 4 Valid for unrestricted operation only. During sound reduced operation modes different power and sound levels are effective. 5 Valid for V10 6m/s 6 Wind speed at hub height 7 Sound power level at hub height Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 7 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] 3.1 Sound Power Level according to IEC for different Hub Heights HH* V 8 10 [m/s] 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 78-80m L 9 WA [db(a)] 100.1 103.7 105.3 105.6 105.1 104.8 104.8 104.8 96.5-100m L 9 WA [db(a)] 100.7 104.2 105.4 105.5 105.0 104.8 104.8 104.8 125-128 m L 9 WA [db(a)] 101.3 104.5 105.6 105.3 104.9 104.8 104.8 104.8 * Hub height depending on foundation design All sound power levels above are based on wind speeds of v 10 at 10 m height. The data of the noise level are based on the requirements of the IEC 61400-11 : 2002 + A1 : 2006 The calculation of the wind speed in 10m height is based on a roughness length of 0.05m. 3.2 Sound Power Level according to FGW Guideline at 95% of rated power The sound power level measured according to the Technische Richtlinie für Windenergieanlagen Teil 1: Rev. 18 der FGW at 95% of the rated power is independent of the hub height: L WA, 95% = 105.6 db(a) 8 Wind speed in a height of 10 meters 9 Sound power level at hub height Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 8 of 9

Power Curve & Sound Power Level REpower 3.4M104 [3.4M/104/50Hz] 4 Calculated electrical power curve (for information only) The calculated electrical power curve of the REpower 3.4M104 is a theoretical one which is applicable at the low-voltage side of the transformer and does not include the transformer losses. It has been derived from the guaranteed electrical power curve in chapter 2 using typical operation conditions of the electrical system. The calculated electrical power curve is for informative purposes only and is not content of the guaranteed electrical power curve. The values of the calculated electrical power curve are a non-binding additional information. No rights or duties for REpower Systems SE result from the values given in this chapter. Legal claims against REpower Systems SE for any costs incurred and/or damages suffered (including direct, indirect, consequential damage or damages, as well as loss of income or profits) caused by the use or non-use of the information offered here or the use of erroneous or incomplete information are excluded. Wind speed Power Thrust coefficient Power coefficient v [m/s] 10 P [kw] ct [-] cp [-] 3.5 37 1.10 0.167 4 94 0.91 0.282 5 253 0.79 0.390 6 479 0.76 0.426 7 791 0.76 0.443 8 1219 0.76 0.458 9 1745 0.76 0.460 10 2309 0.71 0.444 11 2860 0.66 0.413 12 3295 0.57 0.366 13 3370 0.40 0.295 14 3400 0.31 0.238 15 3400 0.25 0.194 16 3400 0.20 0.160 17 3400 0.17 0.133 18 3400 0.14 0.112 19 3400 0.12 0.095 20 3400 0.11 0.082 21 3400 0.09 0.071 22 3400 0.08 0.061 23 3400 0.07 0.054 24 3400 0.06 0.047 25 3400 0.06 0.042 10 Wind speed at hub height Document-No.: SD-3.1-WT.PC.00-B-A-EN Page 9 of 9

F008_228_A03_EN Revision 04 2010-04-19 Sales Document Noise levels Nordex N100/2500 Document number: F008_228_A03_EN Revision: Created: 04 R. Haevernick/TAP Date: 2010-04-19 Responsible departement: Central Engineering/TAP Classification: PB Public Checked: Wilke/TAP AST: Released: 6162 J. Kirchner/PJE H. Resing-Wörmer/TAP Replacement for: F008_228_A03_EN_R03 Validity: K HBG BGG P/T K08 - gamma T Revision index Revision Modification (Section) AST 04 Changing of the statement regarding the sound power levels 6162 03 Extended by hub heights 80 m and 140 m 5456 02 Revision Expiry Date 2854 01 Complete revision 2854 00 First Edition (as K0801_011694_DE_R00) 2854 This document is a translation from German. In case of doubt, the German text shall prevail. Document published in electronic form. Signed original at Central Engineering/ENS. Nordex Energy GmbH, Bornbarch 2, D-22848 Norderstedt, Germany All rights reserved. Observe protection notice ISO 16016.

Noise levels Nordex N100/2500 This document is a translation from German. In case of doubt, the German text shall prevail. Document published in electronic form. Signed original at Central Engineering/ENS. Nordex Energy GmbH, Bornbarch 2, D-22848 Norderstedt, Germany All rights reserved. Observe protection notice ISO 16016. F008_228_A03_EN Revision 04, 2010-04-19 1 / 4

Noise levels Noise Emission Nordex N100/2500 Noise levels according to IEC 61400-11: 2002 [1] Hub height: 80 m Standardised wind speed (at 10 m height) V S [m/s] Apparent sound power level L WA [db(a)] 3 96.8 4 98.8 5 101.1 6 104.4 7 105.8 8 106.0 9 106.0 10 106.0 11 106.0 12 106.0 The calculation of the standardised wind speed at 10 m height according to IEC 61400-11:2002 [1] is based on a terrain roughness length z 0 = 0.05 m. The actual wind speed at 10 m height can be different to the standardised wind speed depending on the actual terrain roughness length. The noise can be tonal in the vicinity of wind turbines. The specified sound power levels include potential tonal penalties K TN according to Technische Richtlinien für Windenergieanlagen [2], without taking account any tonality K TN 2 db. The specified sound power levels are expected values in terms of statistics. Results of single measurements will be within the confidence interval according to IEC 61400-14 [4]. Measurements are to be carried out by a measuring institute accredited for noise emission measurements at wind turbines according to ISO/IEC 17025 [3] at the reference position as defined in IEC 61400-11 [1]. The data analysis must be carried out according to the preferred method 1 of IEC 61400-11 [1]. The tonal penalties in the vicinity of wind turbines K TN based on these measurements are to be determined according to Technische Richtlinien für Windenergieanlagen [2]. [1] IEC 61400-11 ed. 2: Wind Turbine Generator Systems Part 11: Acoustic Noise Measurement Techniques; 2002-12 [2] Technische Richtlinie für Windenergieanlagen Teil 1: Bestimmung der Schallemissionswerte, Revision 18; FGW 2008-02 [3] ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories; 2005-08 [4] IEC 61400-14, Wind turbines Part 14: Declaration of apparent sound power level and tonality values, first edition, 2005-03 F008_228_A03_EN Revision 04, 2010-04-19 2 / 4

Noise levels Noise Emission Nordex N100/2500 Noise levels according to IEC 61400-11: 2002 [1] Hub height: 100 m Standardised wind speed (at 10 m height) V S [m/s] Apparent sound power level L WA [db(a)] 3 97.0 4 99.0 5 101.5 6 105.0 7 106.0 8 106.0 9 106.0 10 106.0 11 106.0 12 106.0 The calculation of the standardised wind speed at 10 m height according to IEC 61400-11:2002 [1] is based on a terrain roughness length z 0 = 0.05 m. The actual wind speed at 10 m height can be different to the standardised wind speed depending on the actual terrain roughness length. The noise can be tonal in the vicinity of wind turbines. The specified sound power levels include potential tonal penalties K TN according to Technische Richtlinien für Windenergieanlagen [2], without taking account any tonality K TN 2 db. The specified sound power levels are expected values in terms of statistics. Results of single measurements will be within the confidence interval according to IEC 61400-14 [4]. Measurements are to be carried out by a measuring institute accredited for noise emission measurements at wind turbines according to ISO/IEC 17025 [3] at the reference position as defined in IEC 61400-11 [1]. The data analysis must be carried out according to the preferred method 1 of IEC 61400-11 [1]. The tonal penalties in the vicinity of wind turbines K TN based on these measurements are to be determined according to Technische Richtlinien für Windenergieanlagen [2]. [1] IEC 61400-11 ed. 2: Wind Turbine Generator Systems Part 11: Acoustic Noise Measurement Techniques; 2002-12 [2] Technische Richtlinie für Windenergieanlagen Teil 1: Bestimmung der Schallemissionswerte, Revision 18; FGW 2008-02 [3] ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories; 2005-08 [4] IEC 61400-14, Wind turbines Part 14: Declaration of apparent sound power level and tonality values, first edition, 2005-03 F008_228_A03_EN Revision 04, 2010-04-19 3 / 4

Noise levels Noise Emission Nordex N100/2500 Noise levels according to IEC 61400-11: 2002 [1] Hub height: 140 m Standardised wind speed (at 10 m height) V S [m/s] Apparent sound power level L WA [db(a)] 3 97.3 4 99.4 5 102.3 6 105.3 7 106.0 8 106.0 9 106.0 10 106.0 11 106.0 12 106.0 The calculation of the standardised wind speed at 10 m height according to IEC 61400-11:2002 [1] is based on a terrain roughness length z 0 = 0.05 m. The actual wind speed at 10 m height can be different to the standardised wind speed depending on the actual terrain roughness length. The noise can be tonal in the vicinity of wind turbines. The specified sound power levels include potential tonal penalties K TN according to Technische Richtlinien für Windenergieanlagen [2], without taking account any tonality K TN 2 db. The specified sound power levels are expected values in terms of statistics. Results of single measurements will be within the confidence interval according to IEC 61400-14 [4]. Measurements are to be carried out by a measuring institute accredited for noise emission measurements at wind turbines according to ISO/IEC 17025 [3] at the reference position as defined in IEC 61400-11 [1]. The data analysis must be carried out according to the preferred method 1 of IEC 61400-11 [1]. The tonal penalties in the vicinity of wind turbines K TN based on these measurements are to be determined according to Technische Richtlinien für Windenergieanlagen [2]. [1] IEC 61400-11 ed. 2: Wind Turbine Generator Systems Part 11: Acoustic Noise Measurement Techniques; 2002-12 [2] Technische Richtlinie für Windenergieanlagen Teil 1: Bestimmung der Schallemissionswerte, Revision 18; FGW 2008-02 [3] ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories; 2005-08 [4] IEC 61400-14, Wind turbines Part 14: Declaration of apparent sound power level and tonality values, first edition, 2005-03 F008_228_A03_EN Revision 04, 2010-04-19 4 / 4