AppNote 9/2012. Solid Phase Micro-Extraction (SPME) Coupled with Selectable 1 D/ 2 D GC-MS for the Determination of Food Product Flavors KEYWORDS

Similar documents
AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

AppNote 4/1998. New Developments in Multi-Dimensional Capillary Gas Chromatography KEYWORDS ABSTRACT

AromaOffi ce: Application of a Novel Linear Retention Indices Database to a Complex Hop Essential Oil

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

Off-gassing of Rubber Particles Used for Athletic Fields using Automated Dynamic Headspace Sampling

AppNote 4/2005. A Selectable Single or Multidimensional. Fraction Collection and Dual Detection for Trace Analysis of Complex Samples KEYWORDS

AppNote 3/2007 KEYWORDS INTRODUCTION. Beverage, Detector, Headspace, Quality Control

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 5/2002. Characterization of a Mass Spectrometer based Electronic Nose for Routine Quality Control Measurements of Flavors KEYWORDS ABSTRACT

AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

AppNote 8/2002 KEYWORDS ABSTRACT. Electronic Nose, Fast GC, Headspace Analysis, Chemometrics,

AppNote 8/2009. Fragrance Profi ling of Consumer Products using a Fully Automated Dynamic Headspace System KEYWORDS ABSTRACT

AppNote 2/2007. Automated Solid Phase Microextraction using the GERSTEL MPS Prepstation and MAESTRO Software KEYWORDS ABSTRACT

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

AppNote 2/2004. Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

AppNote 6/2012. Flavor and Fragrance Analysis of Consumer Products - Dynamic Headspace Compared to Some Traditional Analysis Approaches KEYWORDS

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, D Mülheim an der Ruhr, Germany

AppNote 1/2011 KEYWORDS ABSTRACT

AppNote 8/2011 KEYWORDS ABSTRACT INTRODUCTION

AppNote 8/2000. Volatile Organic Compounds from Adhesives and their Contribution to Indoor Air Problems KEY WORDS ABSTRACT

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT

AppNote 7/2002. Classifi cation of Food and Flavor Samples using a Chemical Sensor KEYWORDS ABSTRACT

Thermal Desorption Unit TDU

AppNote 7/2014. Automating Liquid-Liquid Extractions using a Bench-top Workstation KEYWORDS ABSTRACT. Sample Preparation, Lab Automation, LC/MS/MS

AppNote 8/2012. Rapid Automated Extraction and Confi rmation of Buprenorphine and Norbuprenorphine in Urine by DPX-LC/MS/MS KEYWORDS ABSTRACT

AppNote 3/2012. Rapid Automated Screening of Extractable Compounds in Materials for Food Packaging, Medical or Technical Purposes KEYWORDS ABSTRACT

AppNote 1/2013. Determination of Barbiturates and 11-Nor-9-carboxy- 9 -THC in Urine using Automated Disposable Pipette Extraction (DPX) and LC/MS/MS

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

AppNote 2/1998. Direct Injection of Distilled Spirits with PTV Matrix Removal: The Perfect Splitless Injection? KEYWORDS INTRODUCTION

AppNote 2/2013. A High Throughput Automated Sample Preparation and Analysis Workfl ow for Comprehensive Toxicology Urine Screenings using LC/MS/MS

AppNote 5/2001. The Analysis of the Bitter and Other Flavour Compounds in Beer and Wort by Stir Bar Sorptive Extraction (SBSE) Followed by HPLC

AppNote 3/1998 KEYWORDS ABSTRACT. Beverage, Food & Flavor, PTV, Large Volume Injection, Headspace, Thermal Desorption.

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

AppNote 7/2005. Detection of Packaging Emissions using a Flexible Headspace Sampler Combined with a Multi Sensor System and a Separation Unit KEYWORDS

AppNote 12/2008 KEYWORDS ABSTRACT

KEYWORDS ABSTRACT AppNote 6/2002

AppNote 11/2012. Fully Automated Analysis of Doping Substances in Equine Urine by Disposable Pipette Extraction (DPX) coupled to GC/QqQ-MS KEYWORDS

AppNote 5/1994. The Use of a Multi Purpose Sampler for Headspace GC-MS Analysis of Volatile Organic Compounds in Human Urine

AppNote 3/2011. Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice KEYWORDS ABSTRACT

AppNote 12/2012. Comparison of EG-Silicone-SBSE and Derivatization-PDMS-SBSE for the Analysis of Phenolic Compounds and Off-fl avors in Water KEYWORDS

GERSTEL MultiPurpose Sampler MPS. Versatile autosampler and sample preparation robot

Selective Sample Enrichment of Gaseous Samples using a Cooled Injection System: Trace Determination of Sulphur Components in Natural Gas

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

AppNote 6/2010. part b. High Throughput Method for the Determination of PAHs in Seafood by QuEChERS-SBSE-GC-MS SCOPE PRINCIPLE

AppNote 8/2001 KEYWORDS ABSTRACT. PAH, SPME, SBSE, GERSTEL Twister, Thermal desorption, GC-MS, PCB

Determination of Formaldehyde and VOCs in Wood-based Products using an Automated Micro-Scale Chamber

GERSTEL Thermal Desorption System TDS 3 The GERSTEL TDS 3 is a flexible multi-functional thermal desorption system for highly sensitive and accurate d

AppNote 7/1994. Friedhelm Rogies, Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

AppNote 2/2015 KEYWORDS ABSTRACT

AppNote 7/2013. Comprehensive Automation of the SPE- GC/MS Analysis of Opioids, Cocaine and Metabolites from Serum and Other Matrices KEYWORDS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

PAL SPME Arrow The Better SPME

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

PAL SPME Arrow The Better SPME

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Application. Gas Chromatography February Introduction

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

GC/MS Application Note

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 2/1999. Automated Sample Fractionation and Analysis Using a Modular LC-GC System

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Determination of Volatile Substances Proof of Food Adulteration

GCXGC-qMS with Total Flow Modulation for Volatile secondary metabolites analysis from organically-grown apples by HS-SPME

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Enhanced odour profiling of strawberries using TD GC TOF MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Determination of Limonene Oxidation Products Using SPME and GC MS

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

Jack Cochran, Lindsey Shear-Laude, Alex Hodgson VUV Analytics Emerald Conference. #emeraldconference

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Headspace Technology for GC and GC/MS: Features, benefits & applications

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Analysis of BTEX in Natural Water with SPME

Introduction to GC/MS

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

USP<467> residual solvents

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Transcription:

AppNote 9/2012 Solid Phase Micro-Extraction (SPME) Coupled with Selectable 1 D/ 2 D GC-MS for the Determination of Food Product Flavors John R. Stuff, Jackie A. Whitecavage Gerstel, Inc., 701 Digital Dr. Suite J, Linthicum, MD 21090, USA KEYWORDS Selectable 1 D/ 2 D GC-MS, SPME, food, flavor, fragrance ABSTRACT Identification of important trace components in complex samples like fragrances, natural products, polymers or food products can be challenging. Achieving the mass on column and resolution necessary to locate peaks and identify trace components using a single column chromatographic separation can be difficult, if not impossible. A selectable 1 D/ 2 D GC-MS configuration based on Agilent Technologies capillary flow technology (CFT) and low thermal mass (LTM) GC column modules with dissimilar column phases was used to perform two-dimensional GC analysis of different foodstuffs. Heartcutting was used to transfer analytes from the first to the second column. Mass spectrometry and olfactory detection were performed in parallel. Solid Phase Micro-Extraction was used as a solventless means to introduce sufficient mass of sample onto the precolumn of the multi-dimensional system. SPME offers the added benefit of enabling tuning of the selectivity of the extraction through the choice of coating on the fiber. Separation and identification of selected flavor compounds from food products were used to demonstrate the effectiveness of the system. The main advantages of this configuration were the simple selection of one or two dimensional operation in combination with the ability to use mass spectrometry and olfactory detection in both dimensions for the analysis of odor active compounds.

INTRODUCTION Two dimensional gas chromatography using heartcutting is an effective tool for resolving compounds in a complex matrix. Typical systems use a non-selective detector, such as an FID, in the first dimension and a selective detector, such as an MSD, in the second. The system described in this work uses capillary flow technology (CFT) hardware from Agilent Technologies to enable parallel mass spectrometry and olfactory detection for both the first and second dimension separation. The system requires no hardware changes for operation in either one- or two dimensional mode. The effectiveness of the system is demonstrated in this study using potato chips and spices as examples. Sample introduction. The samples were placed in a VT-32, 32-position tray on the MPS autosampler. The samples were equilibrated at 65 C for 3 minutes at an agitation speed of 250 rpm, and the headspace above the sample extracted for 20 minutes using an SPME fiber. The SPME fiber was subsequently introduced into the CIS 4 and desorbed at 250 C for three minutes at a 5:1 split ratio. RESULTS AND DISCUSSION A diagram of the selectable 1 D/ 2 D GC-MS system configuration is shown in Figure 1. Details of the setup have been described elsewhere. [1,2] PCM EXPERIMENTAL Instrumentation. Analyses were performed on a 6890 equipped with a 5975C inert XL MSD with triple axis detector and LTM Columns (Agilent Technologies), PTV inlet (CIS 4, GERSTEL), MPS 2 Sampler with SPME Option (GERSTEL), and an Olfactory Detection Port ODP 2 (GERSTEL). MS Switching Device GERSTEL ODP2 Analysis conditions. MPS: SPME (DVB-Carboxen-PDMS) CIS 4: SPME liner split, 10:1 250 C (isothermal) Pneumatics: constant pressure Oven: 250 C, held for duration 1st Column: 30 m Rtx-5Sil MS (Restek), LTM format d i = 0.25 mm d f = 0.25 μm 40 C (1 min); 10 C/min; 160 C; 140 C/min; 300 C (3 min) 2nd Column: 30 m DB-Wax (Agilent), LTM format d i = 0.25 mm d f = 0.5 μm 40 C (17 min); 10 C/min; 210 C; 170 C/min; 40 C MSD: full scan, 40-350 amu MSD/ODP: 1/1 split DB-5 DB-Wax Figure 1. Diagram of Selectable 1 D/ 2 D GC-MS setup. The first example shows the determination of volatile compounds in the headspace inside a potato chip bag based on a single dimension separation. A bag of chips was placed on the dashboard of a car for four hours. The car was parked in the sun to accelerate the degradation of the product. When the bag was opened, a distinct rancid odor was detected. Figure 2 shows a comparison of the chromatograms obtained from fresh and rancid chips. The compounds responsible for the rancid odor, mostly aldehydes, are easily seen. Figure 3 shows a comparison of two different brands of chips. Brand Y shows a higher level of acetone and hexanal, indicating that these chips are less fresh. Sample preparation. Potato chips and spice samples were purchased at a local grocery store. The potato chip samples were crushed. A 3.0 gram sample was placed in a 20 ml screw capped vial. The spice samples, approximately 0.25 grams, were placed directly in a 20 ml screw cap vial. AN/2012/9-2

Brand Y: Fresh Chips Pentanal Hexanal Nonadienal Brand Y: Rancid Chips Acetone 2-Heptenal Nonanoic Acid Figure 2. Total ion chromatograms obtained from fresh and rancid chips. Brand X Chips Limonene 2-Methylbutanal Hexanal Siloxane Siloxane Siloxane Brand Y Chips 4-Hydroxy-4-methylpentanoate Acetone Figure 3. Total ion chromatograms obtained from two potato chip brands. Figure 4 shows a comparison of plain and flavored chips from the same manufacturer. The compounds associated with the individual flavors are easily seen. The sour cream and green onion flavor chromatogram shows some methoxy-propoxypropanols which may stem from the packaging material. The salt and vinegar flavor chips exhibit a large acetic acid peak, and the barbecue chips show a very complex chromatogram with a wide range of terpenes. Olfactory detection combined with automated voice recognition and text conversion was performed on this sample. The result was a rather confusing list of descriptors from overlapping peaks in the chromatogram. The section of the chromatogram from 6.5-10.5 minutes, was then heart-cut and transferred to AN/2012/9-3

the second column for further separation. The first dimension column was backflushed starting at 10.6 minutes. The resulting chromatogram is shown in Figure 5. 3-Methylbutanal 2-Methylbutanal Hexanal 4-Hydroxy-4-methylpentanone Limonene Pinene Brand X: Plain Chips Methoxy-propoxypropanols Brand X: Sour Cream & Green Onion Acetic Acid Brand X: Salt & Vinegar Terpenes Brand X: Barbecue Humulene Figure 4. Stacked view of total ion chromatograms for plain and flavored chips. Figure 5. Combined 1 D and 2 D chromatogram obtained from barbecue flavored chips. As can be seen, additional compounds are separated in the second dimension enabling their identification along with a description of their olfactory qualities. Olfactory detection of the compounds separated in the 2nd dimension was used to identify important pyrazines, which are formed during the cooking process and which contribute to the fried potato flavor [3]. Figure 6 shows an enlarged view of the region from 15.5-19.5 minutes. Table 1 list the identities, descriptors and literature aroma profile for the compounds labeled in Figure 6. AN/2012/9-4

1 Table 1. Peak identities for Figure 6. Compound Descriptor Aroma profi le 1 Dimethylpyrazine isomer Burnt Nutty, roasted 2 Dimethylpyrazine isomer Burnt Nutty, roasted 3 Ethyl methylpyrazine Barbecue Potato, hazelnut, coffee 4 Trimethylpyrazine Burnt Potato Roasted, baked potato 5 Dimethyl ethylpyrazine Potato None found Benzaldehyde 2 3 4 5 Figure 6. Enlarged view of a section of the chromatogram obtained from barbecue flavored chips. The second example shows the SPME headspace analysis of a poultry seasoning. The seasoning declaration of ingredients listed thyme, sage, marjoram, rosemary, black pepper, and nutmeg. Figure 7 shows the 1 D chromatogram from the headspace SPME extraction of the poultry seasoning. Overlapping peaks on the front of the cubebene peak were cut over to the 2nd dimension for further separation and identification. Figure 8, shows the resulting 2 D chromatogram. Caryophyllene Camphor Thymol Eucalyptol Borneol Thujone -Pinene Cubabene Figure 7. Total ion chromatogram obtained from poultry seasoning. AN/2012/9-5

Figure 8. Combined 1 D and 2 D chromatogram obtained from poultry seasoning. Figure 9 shows an enlarged view of the area from 20-22 minutes. Two peaks with floral notes, isoledene and ylangene, are well resolved from the cubebene (woody note). The figure also shows the overlay of three separate runs demonstrating the good reproducibility of the system. Only a small portion of the cubebene peak from the first dimension was cut and transferred to the 2 D column, so one would not expect good precision for this peak in the second dimension. Cubabene (Woody) Ylangene (Floral) Isoledene (Floral) Figure 9. Enlarged stacked view of three chromatograms obtained from poultry seasoning. AN/2012/9-6

Stereochemistry can also be an important factor in the odor profile of a compound. The last example shows the use of a chiral column in the second dimension to separate isomers. A standard of 3,3,5-trimethyl-2-cyclohexen- 1-ol was introduced into the GC using SPME. Figure 10 shows the 1 D and 2 D chromatograms for this sample. In the first dimension, a single peak is seen with a flavor descriptor of spicy. When the peak is cut over to the 2nd dimension, four peaks are seen. The first major peak is the isomer responsible for the flavor (spicy, tobacco). None of the other isomers resulted in a perceptible olfactory impression at the ODP. Spicy 3,3,5-Trimethyl-2-cyclohexen-1-ol Isomers Spicy, Tobacco 1st Dimension 2nd Dimension C3 Cyclohexene isomers Isophorone Figure 10. Comparison of 1 D and 2 D chiral separation for 3,3,5-trimethyl-2-cyclohexen-1-ol. CONCLUSIONS The selectable 1 D/ 2 D GC-MS system with a valveless flow switching device is a powerful system for the analysis of trace components in complex samples. The main features of this configuration are the simple selection of one- or two dimensional operation. The setup of the system is facilitated through the use of GERSTEL 1 D/ 2 D Sync software, which calculates critical method parameters for the selected column set. REFERENCES [1] N. Ochiai and K. Sasimoto, J.Chrom.A, 1217, 2903-2910 (2010) [2] N. Ochiai and K. Sasimoto, J.Chrom.A, 1218, 3180-3185 (2011) [3] R.G. Buttery, R.M. Siefert, D.G. Guadagni, and L.C. Ling, J. Agric. Food Chem., 19(5), 969-971 (1971) AN/2012/9-7

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 Digital Drive, Suite J Linthicum, MD 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 +41 (41) 9 21 97 25 swiss@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower One Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br CERTIFIED QM-SYSTEM ISO 9001 IS O C E RTIFIC AT E 9 0 0 1:2 0 0 8 N O. D 0086 Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability