Dear MetNH3 stakeholder,

Similar documents
FINAL PUBLISHABLE JRP REPORT

Towards SI traceable humidity measurements with radiosondes

The Fundamentals of Moisture Calibration

CCQM-P28: An international comparison of ground-level ozone reference standards

Calibration strategies for FTIR and other IRIS instruments for accurate δ 13 C and δ 18 O measurements of CO 2 in air

TC Thermometry Graham Machin

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

e-newsletter n 6 August 31 st, 2018 New calibration facility developed at PTB for relative humidity, associated to dtdlas transfer standard

Preparation of nitrous oxide in air standard (320 nmol/mol) for CCQM-K68

High pressure comparison among seven European national laboratories

EMRP JRP SIB-05. NewKILO. Developing a practical means of disseminating the redefined kilogram (June 2012 May 2015) Stuart Davidson, NPL, UK

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Preparation of nitrous oxide (N 2 O) in air standard being traceable to SI by gravimetric method

Measurement standards and the general problem of reference points in

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

Uncertainty Analysis for Heat-flux DSC Measurements

INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT SIB 63 Falk Tegtmeier 1, Michael Wagner 2, Rolf Kumme 3

RESPONSE OF A RADON CHARCOAL CANNISTER TO CLIMATIC AND RADON VARIATIONS IN THE INTE RADON CHAMBER. A. Vargas, X. Ortega, I.

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Metrology for ammonia in ambient air concept and first results of the EMRP project MetNH3

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

DESIGN, CONSTRUCTION AND EVALUATION OF A HUMIDITY GENERATOR

Publishable JRP Summary Report for JRP IND57 MetroNORM Metrology for processing materials with high natural radioactivity

Commissioning of the Beta Secondary Standard (BSS2)

EMRP JRP ENV54 METROLOGY FOR DECOMMISSIONING NUCLEAR FACILITIES (WP2, WP3)

Using systematic diffusive sampling campaigns and geostatistics to map air pollution in Portugal

Overview. TC Thermometry Graham Machin. Introduction to TC-T Annual meeting Selected comparisons TC-T training for future thermal metrologists

Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION

Metrology for Molecular Radiotherapy MetroMRT V. Smyth (coordinator) Lena Johansson, Andrew Fenwick, Kelley Ferreira et al.

Version 4.0 (09/2017) Version 3.0 (02/2015) Version 2.0 (03/2011) Version 1.0 (07/2007) EURAMET e.v. Bundesallee 100 D Braunschweig Germany

NWAL SUPPORT TO IAEA SAFEGUARDS ANALYSIS P.Doherty, A.Zoigner, K.Sirisena and E.Kuhn IAEA Wagramerstrasse 5, A-1400 Vienna, Austria. 1/.

Humidity Calibration Solutions

Development of the High-Temperature Dew-Point Generator Over the Past 15 Years

MASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT

Develop and characterize a flow metering standard down to 1 nl/min

Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers

MASS AND VOLUME COMPARISONS AT MIKES

In-vacuum realisation of the new definition of the kilogram. Stuart Davidson, National Physical Laboratory, UK JRP Coordinator - NewKILO

CCM-Working Group on Gravimetry (CCM-WGG) Alessandro Germak INRIM, Torino, Italy

International Standardization for Measurement and Characterization of Nanomaterials

Improving the accuracy of NO 2 and Ozone monitoring

ENV55 MetNH3 Metrology for ammonia in ambient air 1 st MetNH3-workshop on the progress in ammonia metrology

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

Uncertainty of Radionuclide Calibrator Measurements of 99

Metrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017

Force Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn. Aimo Pusa MIKES Finland

Reference Materials for Trade and Development: Quality and Comparability

The European Trace Survey Stations Network for Monitoring Airborne Radioactivity

Standardisation of Particulate and Aerosol Measurements. Hanspeter Andres

SIB61 CRYSTAL. Report Status: PU

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Sampling based on Bayesian statistics and scaling factors

On the Emissivity of Silver Coated Panels, Effect of Long Term Stability and Effect of Coating Thickness

Communicating uncertainties in sea surface temperature

Force Key Comparison EUROMET.M.F-K2. (50 kn and 100 kn) EURAMET Project No 518. Final Report. 14 July Pilot: NPL, United Kingdom

Uncertainty of Calibration. Results in Force Measurements

Certificate: / 29 April 2014

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Key Comparisons, the MRA and CMCs: An International Measurement Infrastructure. Robert Wielgosz. Bureau International des Poids et Mesures

Humidity Calibration Solutions

Intercomparison of Thermal Expansion Measurements. EUROMET Project 275. Final Report

Part 5: Total stations

Short Term Scientific Mission Report COST Action OPTIMISE: ES1309

Analytical Measurements, 19, Moskovsky Prospekt, St-Petersburg, Russia

Densitometers Calibration Sorted? But what about in Service? Dr Norman F Glen NEL

Euramet project 1187 Comparison of Instrument Current Transformers up to 10 ka. Technical protocol (March 2012)

ReFH2 Technical Note: Applying ReFH2 FEH13 in small clay catchments

The Claviature of Gas Analysis

Metrological requirements for a laboratory rainfall simulator. M. Colli* 1,2, M. Stagnaro 1,2, L. Lanza 1,2, P. La Barbera 1

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

Components of uncertainty in measurements by means of AWS

DEVELOPMENT OF IMPROVED METHODS FOR CHARACTERISING THE CURE OF COMPOSITE MATERIALS

PRACTICAL UNCERTAINTY BUDGETS FOR SPECTRAL MEASUREMENTS OF LEDS

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

Final Report on the EURAMET.PR-K1.a-2009 Comparison of Spectral Irradiance 250 nm nm

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Introduction to Fourier Transform Infrared Spectroscopy

Specifications for a Reference Radiosonde for the GCOS Reference. Upper-Air Network (GRUAN)

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Final report, On-going Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NIM, 2008

Calibration capabilities at PTB for radiation thermometry, quantitative thermography and emissivity

Centre for Metrology and Accreditation, MIKES

Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials

High-pressure qnmr spectroscopy in condensed- and gas-phase towards determination of impurities and compositions of gas mixtures

Uncertainty of Measurement

Appendix B1. Reports of SMU

Certificate: / 30. April 2015

Traceability of on-machine measurements under a wide range of working conditions

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

A guide to expression of uncertainty of measurements QA4EO-QAEO-GEN-DQK-006

Mercury Stack Monitor SM-4

Measuring isotopes accurately for a safer, healthier and sustainable world

CCM short note on the dissemination process after the proposed redefinition of the kilogram

8 th APMP/TCQM GAS CRM Workshop. K. Kato NMIJ, Japan

19:00 21:30 Registration and reception at Hotel ETAP Altinel. Welcome

Instruments and Methods of Observation Programme

Calibration of MERIS on ENVISAT Status at End of 2002

Transcription:

Dear MetNH3 stakeholder, EMRP JRP MetNH3 Metrology for Ammonia in Ambient Air officially ended on May 31 st 2017. The project partners would like to thank you very much for your interest and your collaboration over the past 3 years. More information on MetNH3 can be found, also in the future, on the project webpage http://www.metnh3.eu. Over the course of summer 2017 three Good Practice Guides on the following subjects will be made available: Good Practice Guide for accurate sampling and preparation of dynamic ammonia gas mixtures Good Practice Guide on the measurement system applicable as optical transfer standard for ammonia in ambient air Good Practice Guide for measurement of ambient ammonia concentrations in the field and application to policy evidence The final highlight of the project has been the 2 nd MetNH3 workshop on ammonia measurement methodology taking place on May 09-10 th at METAS in Switzerland which was attended by 40 stakeholders. The book of abstracts is available on the project website. As one of the main objectives for the participating partners is to develop new capabilities and improved procedures the final newsletter aims at introducing their individual possibilities, particularly those transferable to stakeholders and end users. Improved gas mixture standards The main objective of WP1 was the development of improved gas mixture standards for ammonia (NH 3 ) by static gravimetric and dynamic methods. The highly adsorbing/desorbing behaviour of ammonia molecules and the purity of the balance gas challenge the preparation of ammonia primary reference standards. The findings of partners NPL, VSL, METAS and BAM will be transferred in the Good Practice Guide for accurate sampling and preparation of dynamic NH 3 gas mixtures. NPL and VSL have tested different cylinder types by performing a series of decant tests at the 100 and 10 µmol mol -1 levels and performed stability tests on those mixtures over a period of up to 24 months. VSL performed decanting and stability tests on 3 commercial types of gas cylinders: Spectra Seal (BOC), Aculife 4 (Air Liquide) and cylinders provided by Takachiho. All cylinders showed individual 1

behaviour in adsorption on the interior surfaces. However, for all tested types of cylinders the stability over long term stability is good. The stability tests performed at VSL show that (Fig. 1): The ammonia mixtures of 100 µmol mol -1 are stable for 24 months in both Aculife 4 and Spectra Seal cylinders within a 1 % relative uncertainty (k = 2) The ammonia mixtures of 10 µmol mol -1 are stable for a period of 12 months within a 3 % uncertainty; cylinders under test were Aculife 4 (AC4), Spectra Seal (SS) and cylinders provided by Takachiho (T) 10.5 10 9.5 9 8.5 8 144225 (AC4) 143704 (AC4) 353604 (SS) 853261 (SS) 110015 (T) 110012 (T) 7.5 09/2014 04/2015 10/2015 05/2016 11/2016 Figure 1: Results for the stability of 6 VSL mixtures at 10 µmol mol -1 of NH 3 in nitrogen. The uncertainty bars represent an expanded uncertainty (with k = 2 for a coverage probability of approximately 95 %). The stability measurements carried out at NPL show that (Fig. 2): the ammonia standard mixtures are completely stable in the BOC cylinders at 100 µmol mol -1 level and, after an initial small decay, are stable at 10 µmol mol -1, over the time period studied; the SilcoNert2000 treatment applied to stainless steel cylinders is the most suitable for ammonia mixtures at the lowest level of the NH 3 amount fraction investigated i.e. 10 µmol mol -1. No adsorption loss can be observed. NPL is experienced in both dynamic and gravimetric preparation of many reference gas mixtures relevant to the atmospheric measurement community. Among the several Calibration and Measurement Capabilities (CMCs) that NPL has, it is worth to mention the CMC for NH 3 in nitrogen NPL Primary Reference Materials (NPL PRMs) and NPL Calibrated Gas Mixtures (NPL CGMs) in the 10 100 µmol mol -1 range, with an expanded uncertainty (k = 2) of 10 5 % respectively. During 2

the MetNH3 project, 8 NH 3 /N 2 NPL PRMs, in the 10-2000 µmol mol -1 range, and one 140 µmol mol -1 NH 3 /N 2 NPL CGM have been sold. 10.40 Amount fraction / mmolmol -1 10.20 10.00 9.80 9.60 9.40 9.20 02/2015 05/2015 09/2015 12/2015 03/2016 06/2016 10/2016 Time / months RA5039 SG8050 1842 1648R Figure 2: Results for the stability of 4 NPL mixtures at 10 µmol/mol of NH 3 in nitrogen of which RA5039 and SG8050 are SilcoNert2000 coated cylinders and 1842 and 1648R are BOC cylinders treated with Spectraseal. The uncertainty bars represent an expanded uncertainty (with k = 2 for a coverage probability of approximately 95%). Over the course of MetNH3 VSL adapted its preparation procedure to reduce adsorption by minimising the surface exposed to NH 3 during decanting and by applying only coated materials. Moreover, the analysis and verification procedure for NH 3 mixtures were optimised, thus reducing the analytical uncertainty from 3 % relative to 1 % relative on the 30 µmol mol -1 amount fraction. Currently, VSL has CMCs for ammonia in the range from 30-300 µmol mol -1 with an expanded uncertainty of 3 2 % relative (k=2) and provides calibration services and reference materials worldwide. VSL is responsible for organising the next key comparison between national metrology institutes (CCQM-K117) for NH 3 in N 2 gas mixtures in collaboration with NIST (USA). The knowledge gained within MetNH3 should enable VSL and other participating institutes (e.g. NPL and METAS) to expand their NH 3 CMCs to a range of 10 300 µmol mol -1 with an expanded uncertainty of 3 1 % relative (k = 2). New dynamic calibration capabilities METAS has considerable experience in the dynamic-gravimetric generation of reference gas mixtures combining the permeation method (ISO6145-10) with the dynamic dilution using thermal mass flow controllers (ISO6145-7). The level of uncertainty in the dynamic generation is unaffected 3

by loss of NH 3 molecules through adsorption yet, adsorption increases stabilisation times. Thus, tests of the effects of adsorption and desorption were carried out on different surfaces of materials widely used for the preparation of reference gas mixtures (e.g. PFA, PTFE, stainless steel). In addition the influence of humidity on the adsorption of NH 3 in the preparation of reference gas mixtures was assessed. It was concluded that adsorption on stainless steel surfaces in contact with NH 3 can be minimised by up to 90 % when a silica-based coating (SilcoNert2000, SilcoTek Inc.) is applied on gaswetted surfaces. Thus, for the construction of a mobile reference gas generator (ReGaS1) combining permeation and dynamic dilution SilcoNert2000 has been applied to all surfaces in contact with NH 3. ReGaS1 is a development beyond the state of the art as it allows for the on-site permeation and dynamic dilution over two dilution steps and thus for the dynamic generation of NH 3 at ambient amount fractions (0.5 500 nmol mol -1 ) with U NH3 3 % (Fig. 3). ReGaS1 is available for rent for applications in the field and in laboratories (applied in the three MetNH3 intercomparisons). In addition, METAS offers calibration services for extractive optical NH 3 instrumentation as well as for gas mixtures in pressurised cylinders (< 300 µmol mol -1 ), the latter at very low gas consumption from the cylinder to be tested. The next NH 3 calibration campaign at METAS will be carried out in autumn 2017. Figure 3: Different NH 3 in N 2 amount fractions generated with ReGaS1 using one dilution step, recorded with a CRDS. The response to a new concentration setting is imminent and the stabilisation time at a new concentration level very fast and with variability 0.5 %. The uncertainty in the generated NH 3 amount fractions is 1.5 % for NH 3 > 10 nmol mol-1 and 3.0 % for NH 3 > 10 nmol mol -1 (with k = 2 for a coverage probability of 95%). 4

A similar mobile gas standard generator (GASI2) has been developed at BAM also combining the permeation method with dynamic dilution to the relevant amount fraction range (0.5 500 nmol mol -1 ), yet with slightly higher uncertainty U NH3 3.7 %. It can be applied for the calibration of extractive optical methods and sensor measuring devices. Improved optical transfer standards The goal of WP2 was the realisation of optical transfer standards (OTS) for NH 3, i.e. IR spectrometric analysers performing absolute NH 3 amount fraction measurements. Such instrumental standards do not rely on a calibration with NH 3 gas standards but use stable molecular parameters (so-called spectral line parameters) to describe the light absorption properties of ammonia and to deduce the amount fraction in air samples. This opens a complementary route to traceability and instrument calibration and circumvents difficulties in the temporal stability of NH 3 reference gas standards normally used for instrument calibration. An extractive, commercial cavity ring-down (CRDS) instrument by Picarro Inc. with a detection limit < 1 nmol mol -1 was used by PTB as a starting point to realise an OTS. PTB developed an OTS in collaboration with DFM by accomplishing the following steps: 1. Writing a new validated spectral data evaluation routine enabling absolute measurements including uncertainty contributions from all relevant parameters in compliance with the GUM 2. Re-measuring and refining required infrared spectral parameters of ammonia (line strengths) with unprecedented measurement uncertainty (see publication list) 3. Metrological characterisation of the instrument 4. Performing validation measurements of reference gas mixtures 5. Implementing the approach in a field comparison of NH 3 analysers This approach will be described in more detail in the Good Practice Guide on the measurement system applicable as optical transfer standard for ammonia in ambient air. From the field trial, the expanded uncertainty was found to be approximately U(x NH3 ) 2.4 % x NH3 + 0.8 nmol mol -1 (k = 2). Under laboratory conditions with dry gas samples, the performance is better, approximately U(x NH3 ) 2.0 % x NH3 + 0.2 nmol mol -1. The OTS developed in MetNH3 extends PTB s portfolio of absolute spectroscopic methods to trace ammonia in air. State of the art test facility commissioned As part of the planned NH 3 sensor validation programme in WP3, NPL s Controlled Atmosphere Test Facility (CATFAC) was commissioned in the early stages in MetNH 3 and employed for the first systematic exposure testing of ambient ammonia passive samplers. Seven 28-day exposure tests at different concentrations with ALPHA, Gradko, PASSAM and Radiello diffusive samplers (14 days), 5

and DELTA denuders. The exposed samplers were returned to the different manufacturers for analysis. Fig.4 shows the percentage deviation reported by each participant from the known traceable concentrations of NH 3. Some measurements were in good agreement with the known traceable reference concentrations while other devices exhibited over-reading and under-reading thereby clearly demonstrating the need for this validation work to be carried out. Figure 4: Summary of the mean of the reported NH 3 concentrations for diffusive and pumped samplers tested in the CATFAC, expressed as a percentage deviation from the reference values. Sampling rate U/ m 3 h -1 Reference T C Sampling rate U/ m 3 h -1 Reference T ( C) Manufacturer Diffusive sampler Measured, this work Manufacturer provided CEH ALPHA 3.49 x 10-3 20 ± 1 3.45 x 10-3 sampler 3.24 x 10-3 10 Gradko 3.5 cm diffusion 2.00 x 10-4 20 ± 1 1.62 x 10-4 20 tube Gradko DIFRAM-400 3.15 x 10-3 20 ± 1 2.82 x 10-3 20 PASSAM Passam ammonia sampler 1.88 x 10-3 20 ± 1 1.89 x 10-3 20 Fondazione Salvatore Maugeri (FSM) FUB Radiello sampler (blue body) Radiello sampler (white body) 1.14 x 10-2 20 ± 1 1.37 x 10-2 20 1.41 x 10-2 25 1.28 x 10-2 20 ± 1 Not Applicable 6 Not Applicable Table 1: Summary of NPL CATFAC measured and manufacturer diffusive sampling rates of NH3 passive samplers.

The results were employed to determine new provisional values of the diffusive sampling rates for the devices tested. Table 1 summarises the provisional data obtained. This work has provided the tools to improve the chain of traceability for low concentration ambient measurements of ammonia. Two international field measurement intercomparisons hosted CEH has more than 20 years experience in the field application of NH 3 measurements and supported the application of new standards and processes by designing and hosting two intercomparison studies as part of the MetNH3 project: one for intercomparing commercial passive samplers and the second for high resolution active ammonia measurement. Both took place in the summer of 2016 and were open application events. The passive sampler intercomparison was linked to the CATFAC facility experiment (see above). All participants took part in both, with additional participants in the field experiment. The contacts for all the sampler providers including CEH are listed below. Figure 5 Diffusion samplers exposed over 4 week periods, with both the manufacturer uptake rate and the new uptake rate that was derived by the CATFAC study in WP3. 1a1 ALPHA CEH Edinburgh 1, 1a2 ALPHA CEH Edinburgh 2, 1 b ALPHA CEH Lancaster, 2 Gradko DIFRAM, 5 Gradko tubes, 7 Passam. The NH 3 passive sampler field application intercomparison study as part of WP3, was undertaken at an artificial NH 3 release on a peatland site that simulates NH 3 emissions from a medium range 7

poultry farm. Samplers were placed at 12m, 32m and 60m from the emission source, as well as at a background site (ambient concentrations). In total there were 8 participants in the intercomparison with 12 different sets of samplers being tested. Samplers were exposed for a period of 2 or 4 weeks dependent on the recommendations by the supplier, over the period from the 16 th August 2016 to 11 th October 2016. The results are summarised in Fig. 5. All samplers and laboratories had good data capture and excellent quality assurance results. Fig. 5 shows the reported concentrations for two periods for samplers/laboratories which had taken part in the CATFAC study and the impact of the new uptake rates had on the agreement between samplers. Following this study a peer reviewed publication are currently being written and an annual quality assurance activity based on the intercomparison has been integrated into the UK s National Ammonia Monitoring Network in 2017 and 2018. Figure 6: Provisional results of the NH3 intercomparison study held in South East Scotland. The NH 3 on-line ambient ammonia measurement field intercomparison study was held at an intensively managed grassland in south east Scotland from the 21 August 2016 to the 1 st September 2016. In total 15 participants, including SMEs, regional and national institutions and MetNH3 project partners took part in the intercomparison and 10 different measurement technologies were applied. Several techniques were replicated but with different field set-ups, which has allowed an assessment of the effect of set-up on ammonia measurement to be undertaken. Fig. 6 is a provisional summary of the ammonia concentration measurement made over the full intercomparion period by all instruments. It is expected that a peer-review publication will be submitted and the observations from the exercise incorporated into the Good Practice Guide for measurement of ambient ammonia concentrations in the field and application to policy evidence. 8

Ammonia passive sampler providers and institutes which participated in the field passive sampler intercomparison: CEH Edinburgh (UK): ALPHA samplers Contact name/s: Amy Stephens and Sim Tang IVL (Sweden): IVL samplers Contact name/s: Martin Ferm Fondazione Salvatore Maugeri, FSM (Italy): Radiello Contact name/s: Paolo Sacco RIVM (NL): diffusion tubes Contact name/s: Ariën Stolk CEH Lancaster (UK): ALPHA samplers Contact name/s: Jan Poskitt FUB (Switzerland): Radiello and IVL samplers Contact name/s: Eva Seitler and fub@fub-ag.ch Gradko (UK): diffusion tubes and DIFRAM samplers Contact name/s: Linda Gates Passam (Switzerland): Passam samplers Contact name/s: Jean-Marc Stoll Peer-reviewed publications The following peer-reviewed publications have to date been published in the framework of MetNH3: Andrea Pogány et al.: A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air. Meas. Sci. Technol. (2016) 27 115012 Nicholas A. Martin et al.: The application of a cavity ring-down spectrometer to measurements of ambient ammonia using traceable primary standard gas mixtures. Appl. Phys. B (2016) 122: 219. A. Pogány et al.: High-Accuracy Ammonia Line Intensity Measurements at 1.5 µm. Imaging and Applied Optics 2016, paper JT3A.15. 9

Contact and further information You are very welcome to forward our newsletter to your contacts interested in metrology for ammonia in ambient air. Contact any JRP partner for further information. METAS (Federal Institute of Metrology), Switzerland. Bernhard Niederhauser (Coordinator) BAM (Federal Institute for Materials Research and Testing), Germany. Dr. Carlo Tiebe DFM (National Metrology Institute), Denmark. Dr. David Balslev-Harder MIKES Metrology (VTT Technical Research Centre), Finland. Dr. Timo Rajamäki NPL (National Physical Laboratory), United Kingdom. Dr. Nicholas Martin PTB (National Metrology Institute), Germany. Dr. Nils Lüttschwager UBA (Federal Environment Agency), Germany. Dr. Klaus Wirtz VSL (National Metrology Institute), The Netherlands. Janneke van Wijk Researcher Excellence Grants REG1: CEH Centre for Ecology and Hydrology, United Kingdom. Dr. Christine Braban REG2: UH University of Helsinki, Finland. Dr. Olavi Vaittinen The JRP partners have been regularly consulted by an external board of advisors 10