Protein identification is made easy with Micromass optional BioLynx and ProteinLynx software packages.

Similar documents
[ instrument specifications ]

Finnigan LCQ Advantage MAX

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Thermo Finnigan LTQ. Specifications

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

MICROMASS Q-Tof micro MASS SPECTROMETER

ICP-MS. High Resolution ICP-MS.

Translational Biomarker Core

TANDEM MASS SPECTROSCOPY

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Thermo Scientific TSQ Quantum Ultra Ultra AM/Ultra EMR Performance Specifications

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

IN QUALITATIVE ANALYSIS,

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Extrel is widely respected for the quality of mass spectrometer systems that are

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Analysis of Polar Metabolites using Mass Spectrometry

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Agilent G2350A Atomic Emission Detector (AED)

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Chemistry Instrumental Analysis Lecture 37. Chem 4631

LC-MS Based Metabolomics

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Information Dependent Acquisition (IDA) 1

Analyst Software. Automatic Optimization Tutorial

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Quattro Micro - How does it work?

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

the spectrum from a mixture of proteins can be extremely complex.

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Catalysis CAPABILITIES

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Mass Spectrometry in MCAL

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Introduction to the Q Trap LC/MS/MS System

Powerful Scan Modes of QTRAP System Technology

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

MetWorks Metabolite Identification Software

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Agilent G3212 GC-APCI Source

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

UPLC Intact MASS Analysis Application Kit

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

ABI 3200 Q TRAP LC/MS/MS System

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Agilent ESI and APCI sources: for polar to non-polar compounds

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

Webinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen

Talk Line-up. MassTech, Inc Columbia Gateway Drive Columbia, Maryland (443) Goals for MT Explorer 50 Development

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

for XPS surface analysis

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Training Courses. Chromatography training from the Crawford Scientific experts

[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Mass spectrometry has been used a lot in biology since the late 1950 s. However it really came into play in the late 1980 s once methods were

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

of mass spectrometry

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

PosterREPRINT AN INTERACTIVE PHYSICOCHEMICAL PROPERTY PROFILING SOFTWARE FOR EARLY CANDIDATE ANALYSIS IN DRUG DISCOVERY INTRODUCTION

CRL MASS SPECTROMETRY FACILITY USER MANUAL LCT CLASSIC A & B

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Transcription:

SPECIFICATION NOTE 126 Q-Tof 2 Q-Tof 2 is a new type of mass spectrometry tool for peptide sequencing, and protein characterisation and metabolite identification, a powerful alternative to the conventional triple stage quadrupole. Q-Tof 2 is a high-sensitivity detector for on-line liquid chromatography - mass spectrometry (LC-MS and LC-MS-MS). Q-Tof 2 is a compact, easy-to-use system featuring a straightforward user interface, incorporating a wealth of security, automation and biopolymer sequencing tools all running in Microsoft Windows NT. The orthogonal acceleration geometry exploited by Q-Tof 2 allows parallel detection of ions across the full mass range from a continuous ion beam. This is in contrast to conventional instruments that must scan over one mass at a time. The net result... Q-Tof 2 delivers up to a 100 fold gain in sensitivity. At the same time mass resolution in excess of 10 000 (FWHM) enables accurate mass measurements to be obtained in both MS and MS/MS modes. Masslynx 3 enables full integration of Q-Tof 2 with a wide range of solvent delivery and sample handling systems. Masslynx 3 is the benchmark for biochromatography-ms data handling. Each applications module in the MassLynx family has been written in collaboration with leading bioanalysts - ensuring a degree of intelligent integration previously absent in Mass Spectrometry data systems. Protein identification is made easy with Micromass optional BioLynx and ProteinLynx software packages. Metabolite identification is made easy with Micromass optional Metabolynx software package. Z Spray Z Spray, Micromass quantum leap in robust API inlet technology is featured on Q-Tof 2 providing complete flexibility of analysis from small molecules to intact proteins with electrospray (ES), NanoFlow ES and atmospheric pressure chemical ionisation (APcI) options.

Specification Hardware LC Interface Atmospheric pressure ionisation source for sample introduction via Electrospray (ESI) and/or Atmospheric Pressure Chemical Ionisation (APcI) inlet probes allowing flow rates of 5-1000µL/min (ESI) and 200-2000µL/min (APcI). Samples may be introduced by direct infusion in solution, or the system may be interfaced directly to a HPLC system. The ion source incorporates a hexapole ion bridge to maximise transmission of ions from atmospheric pressure into the analyser. Analyser The first analyser consists of a precision engineered molybdenum quadrupole mass filter. A prefilter is fitted to prevent contamination of the main filter rods. An enclosed hexapole collision cell is included for high efficiency MS/MS fragmentation. The second analyser comprises a two stage orthogonal extraction region and linear reflectron for high resolution performance. Detectors Microchannel plate ion counting detector system for detecting positive and negative ions and acquiring both MS and MS/MS data. Dynolite photomultiplier detector with conversion dynode and phosphor for optimising the ion source and first analyser transmission. Vacuum System Fully automated, differentially pumped vacuum system using 3 water cooled, 250 L/hr turbomolecular pumps for source, quadrupole and TOF housings. An isolation valve is situated after the sampling cone allowing rapid source cleaning without breaking vacuum. A single E2M28 rotary backing pump is used. Data System Compaq Professional workstation AP200, 550MHz Pentium III, 128MB RAM, 9.1GB Wide-Ultra SCSI HDD, 32xCD ROM ELSA Gloria Synergy+Graphics. MS Operating System The system is controlled using the Micromass MassLynx NT operating system incorporating manual and automated instrument optimisation; automated instrument calibration; MS acquisition; MS/MS acquisition; selected ion monitoring via reconstructed mass chromatograms; chromatogram and spectrum processing. HPLC pump and autosampler control; photodiode array detector control and data acquisition; 3D data mapping; comprehensive quantitation package. Security MassLynx NT contains an advanced security system and features designed to aid GLP compliance including: password protected multi-level user accounts; logging of all LC-MS acquisition parameters; logging and time stamping of method modifications and data manipulation; secure audit trail. Options Open Access OpenLynx LC provides a non-expert, walk-up system for the analysis of single compounds or simple mixtures for the automated determination of molecular weights and structural information. The system may be customised using factory produced software modules and includes a separate login PC to give maximum system security and ensure data integrity. OpenLynx Diversity Designed for the analysis of single compounds or simple mixtures produced by combinatorial chemistry or multiple parallel synthesis. Samples may be introduced from a variety of autosamplers, but the most usual method of sampling is from 96 well microtitre plates using a Gilson autosampler under Masslynx control. OpenLynx Diversity provides confirmation of the presence of expected molecular weights and produces reduced data sets and for simple data interpretation. MetaboLynx (Automated Metabolite Identification) MetaboLynx automatically processes data to search for expected and unexpected metabolites from an LC-MS acquisition using user-defined thresholds for peak intensity, spectrum purity and exact mass measurement. A control sample comparison may also be used to exclude matrix-related compounds. Moreover, it will set-up an MS/MS acquisition method containing the potential metabolite information ready for the subsequent acquisition of product ion spectra by LC-MS/MS. Optional DAD (Diode Array Detector) or analog inputs enable fully integrated data sets to be acquired and processed. The results are reported in a browser format that allows quick and efficient review of the data. The processing method is user configurable to allow the system to be applied to in vitro or in vivo studies. ProteinLynx (Automated Protein Identification) ProteinLynx automatically processes MS/MS data into a database query for the client-server ProteinProbe search engine. Results are returned in an interactive browser format that allows quick and efficient review of the results. Search parameters may be modified to refine the results or match previously unmatched data. Data may be acquired using on-line chromatography and data dependent MS to MS/MS switching for fully automated protein identification. Protein Lynx incorporates the BioLynx tool kit. BioLynx A suite of software tools for the interpretation of data produced from the analysis of proteins, peptides and oligonucleotides including: amino

acid sequence editor, nucleic acid sequence editor, EMBL CD-ROM library compatibility, protein mass fingerprinting, protein digestion simulators, hydropathic profiles. ProteinProbe interactive client-server database search engine compatible with the SwissPROT protein database and any other FASTA formatted protein, oligonucleotide or EST database. MassSeq (de novo peptide sequencing package) MassSeq uses a rigorous probabilistic algorithm to deduce de novo peptide sequence from the ESI-MS/MS spectrum of peptides, typically derived from protein digests. MaxEnt Using Maximum Entropy processing applied to mass spectrometry data. MaxEnt aids the enhancement of complex spectra. MaxEnt 1 allows the deconvolution of overlapping multiply-charged spectra produced by the analysis of protein mixtures and glycosylated proteins. MaxEnt 2 Reconstruct gives enhanced resolution of m/z data within the mass range of the mass spectrometer to give unambiguous assignment of the charge state of multiply-charged peaks. MaxEnt 3 is used to deconvolute multiple charge state MS/MS data to a single charge state and subsume higher mass isotopes into the lowest mass isotope peak. The resulting data is used for de novo peptide sequencing or database searching. Performance Specifications Mass Range Exceeding 20,000 Daltons. Mass Resolution 10,000 (FWHM) on (M+6H) 6+ from bovine insulin. Full scan MS sensitivity Full scan MS sensitivity (i) Positive ion mode The signal height obtained from a sample consumption of 200 fmol of horse heart myoglobin (16952 Da) will be greater than 166 ion counts (equivalent to 600 ion counts at 1GHz sampling frequency) on the most intense peak in the charge state envelope. A solution of 200 fmol/ml horse heart myoglobin in 50/50 acetonitrile/water + 0.2% formic acid will be infused at a flow rate of 5mL/min. (ii) Negative ion mode The signal to noise obtained from the sample consumption of 1 ng of raffinose will be greater than 200:1. A solution of 5 ng/ml raffinose in 50/50 acetonitrile/water (no additives) will be introduced at 10mL/min. The signal to noise ratio will be measured on the (M-H) - peak at m/z 503. Mass Measurement accuracy (with internal reference) The mass measurement accuracy of the Q-Tof 2 under normal operating conditions, when at least one suitable peak of known mass is present and which can be used as an internal reference, is such that the RMS error between the measured and the accepted masses of peaks which have sufficient intensity and are free from interference from other masses will be less than 5 ppm over the range from 150-900 daltons. Acquisition Rates (i) oa-tof pulse repetition rate Variable up to 30,000 spectra/sec. (ii) Histogrammed spectra acquisition rates over the range m/z 100-1000 a) Up to 4 spectra/sec for continuum (profile) spectra at 3.6GHz TDC rate. Precursor ion selection mass range in MS/MS mode Up to m/z 4000. Precursor ion mass selection in MS/MS mode Variable down to 1 dalton at m/z 1000. Variable down to 2 dalton at m/z 2000. Variable down to 3 dalton at m/z 3000. Full scan sensitivity in MS/MS mode The signal to noise from a consumption of 20 fmol of [Glu 1 ] -Fibrinopeptide B (1569 Da) from a solution of 100 fmol/µl and at flow rate of 5µL/min will be greater than 30:1 on the most intense y sequence ion from the MS/MS spectrum of the doubly charged precursor ion. Options (A) Nanoflow electrospray Full scan sensitivity in MS/MS mode The signal to noise from a consumption of 2 fmol of [Glu 1 ] -Fibrinopeptide B (1569 Da) from a solution of 500 fmol/µl concentration in MeOH/H 2 O + 0.2% formic acid solution, using glass micropipettes with 1 or 2µm tips, will be greater than 30:1 on the most intense y sequence ion from the MS/MS spectrum of the doubly charged precursor ion. The integration period per spectrum will be about 5 sec and data will be summed over a period appropriate for the required consumption of sample. (B) Transform software (Software for the determination of molecular weight from a spectrum containing a series of multiply charged ions on an m/z scale by a transform of the data to a true mass scale.) Mass measurement accuracy (no internal reference) Measured from the mean of five repeat analyses of the globin from normal human haemoglobin. Mass calibration to be performed using the multiply charged globin peaks from a separate analysis. The mean measured mass shall be 15867.2 +0.5 Da and the standard deviation of the mean <0.5 Da. It is recommended that a solution containing

Installation Requirements Power requirements The instrument requires a single phase 50-60 Hz, 230V nominal power supply rated at 13A (UK) or 15A (Europe). In the USA and Canada a single-phase 50 60 Hz supply at 230V phase to neutral fused and rated at 15A is required. Alternatively two phases of a 50 60 Hz 208V phase to phase, 3 phase supply, rated and fused at 15A may be used. An optional transformer is available to accommodate other supply voltages. Power consumption Typical power consumption excluding ancillary equipment (computer, LC etc.) 1.5kW. Water supplies The heat dissipated into the cooling water is about 400 Watts. The typical water flow required to dissipate the heat generated by the turbo pumps is 35 L/hour for an inlet temperature of about 20 0 C or 23 L/hour at an inlet temperature of about 15 0 C assuming an outlet temperature of about 30 0 C. Gases and regulators. Nitrogen: Dry nitrogen, oil free supply regulated at 7 bar (100 psi) minimum outlet pressure to provide nebulising and drying gas to the instrument free position and away from excessive amounts of dust. The maximum ambient laboratory temperature should not exceed 30 0 C (86 0 F), optimum temperature lies in the range 19-22 0 C (66-72 0 F). Short term (1.5 hour) variations should be no more than 2 0 C. The relative humidity should not exceed 70%. Heat dissipated into the laboratory from the instrument is about 1.2 kw. The instrument conforms to IEC 1010-1 Pollution Degree 1 and Installation Category II. Exhausts Separate vents are required to remove the API gas exhaust and rotary pump exhaust from the laboratory. Room size and access requirements The Q-Tof 2 analyser unit is 730 mm (28.5 inch) wide by 1320 mm (52 inch) deep and weighs 500 kg (1100 lb). It is mounted on 4 rolling casters, which allow the instrument to be easily transported over smooth surfaces. A separate table 1200 mm (47 inch) by 730 mm (28.5 inch) is supplied for the computer terminal. Doorways through which the instrument is to be transported should be a minimum of 770 mm (30.5 inch) wide. Collision gases: Typically argon is used as the collision gas for CID experiments other gases may be used if required. Supply must be pressure regulated at 50psi max. Environment It is recommended that the instrument is sited in an air conditioned laboratory, in a draught

MICROMASS UK Limited Floats Road Wythenshawe Manchester M23 9LZ Tel: + 44 (0) 161 945 4170 Fax: + 44 (0) 161 998 8915 http://www.micromass.co.uk UK Sales Desk, Tel: 0161 946 0565 USA Beverly MA, Tel: 978 524-8200 Canada Pte-Claire, Tel: 514 694-1200 EUROPE Weesp, Tel: +31 (0)294-480484 Netherlands Weesp, Tel: 0294-480484 Austria Achau, Tel: 022 3672 668 Belgium Vilvoorde, Tel: 02-2534550 France Villeurbanne, Tel: 04 72 14 89 00 Germany Idstein, Tel: 0130-817249 Sweden T by, Tel: 08-7567130 Switzerland Sissach, Tel: 061-9730800 Certificate No 951387 Micromass is a registered trademark of Micromass Limited (Reg. U.S. Pat. & Tm. Off.). Microsoft Windows NT is a registered trademark of the Microsoft Corporation. No attempt is made to supersede this or any other copyrights. SPECIFICATION NOTE No. SN126/ICA Version 1 The product information in this document was correct at the time of printing, however specifications are subject to alteration without notice due to the Micromass UK Limited philosophy of continual product innovation and development and any information contained herein should not be construed as a contractual commitment by Micromass UK Limited. All orders are accepted subject to our current Conditions of Sale, copies of which are available on request. ' Micromass Limited, September 1999 09/99 2M