Aalborg Universitet. Mathematical Models for Room Air Distribution Nielsen, Peter Vilhelm. Published in: System Simulation in Buildings

Similar documents
Aalborg Universitet. Specification of a Two-Dimensional Test Case Nielsen, Peter Vilhelm. Publication date: 1990

The IEA Annex 20 Two-Dimensional Benchmark Test for CFD Predictions

Aalborg Universitet. Comparison between Different Air Distribution Systems Nielsen, Peter Vilhelm. Publication date: 2006

Aalborg Universitet. Selection of Air Terminal Device. Nielsen, Peter V. Publication date: 1988

Characterization of the Airflow from a Bottom Hung Window under Natural Ventilation

Aalborg Universitet. Windows Heiselberg, Per Kvols; Svidt, Kjeld; Nielsen, Peter Vilhelm. Publication date: 2000

Aalborg Universitet. Simulation of Simple Test Case 2D1 Two-Dimensional Isothermal Forced Convection Skovgaard, M.; Nielsen, Peter Vilhelm

Sound absorption properties of a perforated plate and membrane ceiling element Nilsson, Anders C.; Rasmussen, Birgit

Modifications of the V2 Model for Computing the Flow in a 3D Wall Jet Davidson, L.; Nielsen, Peter Vilhelm; Sveningsson, A.

Aalborg Universitet. Published in: Proceedings of Roomvent Publication date: 2007

Aalborg Universitet. Flow Pattern in Ventilated Rooms with Large Depth and Width. Yue, Zou; Nielsen, Peter V. Publication date: 2000

Aalborg Universitet. CFD in Ventilation Design Nielsen, Peter Vilhelm. Publication date: 2009

Aalborg Universitet. Lecture 14 - Introduction to experimental work Kramer, Morten Mejlhede. Publication date: 2015

The dipole moment of a wall-charged void in a bulk dielectric

Aalborg Universitet. Publication date: Document Version Publisher's PDF, also known as Version of record

High and Low Reynolds number Measurements in a Room with an Impinging Isothermal Jet Skovgaard, M.; Hyldgaard, C. E. ; Nielsen, Peter Vilhelm

Parametric Study on the Dynamic Heat Storage Capacity of Building Elements Artmann, Nikolai; Manz, H.; Heiselberg, Per Kvols

A Discussion of Low Reynolds Number Flow for the Two-Dimensional Benchmark Test Case

Lidar calibration What s the problem?

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Iqbal, Ahsan; Afshari, Alireza; Heiselberg, Per Kvols; Høj, Anders

Published in: Proceedings of IECON 2016: 42nd Annual Conference of the IEEE Industrial Electronics Society

Unknown input observer based scheme for detecting faults in a wind turbine converter Odgaard, Peter Fogh; Stoustrup, Jakob

Design possibilities for impact noise insulation in lightweight floors A parameter study

An Equivalent Source Method for Modelling the Lithospheric Magnetic Field Using Satellite and Airborne Magnetic Data

Influence of the shape of surgical lights on the disturbance of the airflow Zoon, W.A.C.; van der Heijden, M.G.M.; Hensen, J.L.M.; Loomans, M.G.L.C.

Aalborg Universitet. All P3-equipackable graphs Randerath, Bert; Vestergaard, Preben Dahl. Publication date: 2008

COMPARISON OF THERMAL HAND MODELS AND MEASUREMENT SYSTEMS

Citation for published version (APA): Burcharth, H. F. (1988). Stress Analysis. Aalborg: Department of Civil Engineering, Aalborg University.

Published in: Proceedings of the 21st Symposium on Mathematical Theory of Networks and Systems

Prediction of airfoil performance at high Reynolds numbers.

Reducing Uncertainty of Near-shore wind resource Estimates (RUNE) using wind lidars and mesoscale models

Aalborg Universitet. Seawall Overtopping Tests sea erosion study : Sohar Cornice Frigaard, Peter. Publication date: 1990

GIS Readiness Survey 2014 Schrøder, Anne Lise; Hvingel, Line Træholt; Hansen, Henning Sten; Skovdal, Jesper Høi

Analytical Studies of the Influence of Regional Groundwater Flow by on the Performance of Borehole Heat Exchangers

Indoor Climate of Large Glazed Spaces Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per Kvols; Svidt, Kjeld

Numerical modeling of the conduction and radiation heating in precision glass moulding

Tectonic Thinking Beim, Anne; Bech-Danielsen, Claus; Bundgaard, Charlotte; Madsen, Ulrik Stylsvig

ROOM AVERAGE VELOCITY EQUATION A TOOL TO IMPROVE DESIGN OF THERMAL COMFORT CONDITIONS

Estimation of Peak Wave Stresses in Slender Complex Concrete Armor Units

Development of a Dainish infrastructure for spatial information (DAISI) Brande-Lavridsen, Hanne; Jensen, Bent Hulegaard

A note on non-periodic tilings of the plane

Aalborg Universitet. Land-use modelling by cellular automata Hansen, Henning Sten. Published in: NORDGI : Nordic Geographic Information

Reflection of sound from finite-size plane and curved surfaces

The M/G/1 FIFO queue with several customer classes

Multi (building)physics modeling

A Note on Powers in Finite Fields

A numerical study of vortex-induced vibrations (viv) in an elastic cantilever

Crack Tip Flipping: A New Phenomenon yet to be Resolved in Ductile Plate Tearing

Characterization of microporous silica-based membranes by calorimetric analysis Boffa, Vittorio; Yue, Yuanzheng

Graphs with given diameter maximizing the spectral radius van Dam, Edwin

Spatial decay rate of speech in open plan offices: the use of D2,S and Lp,A,S,4m as building requirements Wenmaekers, R.H.C.; Hak, C.C.J.M.

Aalborg Universitet. The number of independent sets in unicyclic graphs Pedersen, Anders Sune; Vestergaard, Preben Dahl. Publication date: 2005

Validation of Boundary Layer Winds from WRF Mesoscale Forecasts over Denmark

Measurements of the angular distribution of diffuse irradiance

Upper and Lower Bounds of Frequency Interval Gramians for a Class of Perturbed Linear Systems Shaker, Hamid Reza

Diffusion of sulfuric acid in protective organic coatings

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. Published in: IEEE International Conference on Acoustics, Speech, and Signal Processing. Creative Commons License Unspecified

Steady State Comparisons HAWC2 v12.2 vs HAWCStab2 v2.12

Kommerciel arbejde med WAsP

Sorption isotherms for textile fabrics and foam used in the indoor environment

Higher-order spectral modelling of the diffraction force around a vertical circular cylinder

Radioactivity in the Risø District July-December 2013

Radioactivity in the Risø District January-June 2014

Optimizing Reliability using BECAS - an Open-Source Cross Section Analysis Tool

On a set of diophantine equations

Geometry explains the large difference in the elastic properties of fcc and hcp crystals of hard spheres Sushko, N.; van der Schoot, P.P.A.M.

Simulating wind energy resources with mesoscale models: Intercomparison of stateof-the-art

Aalborg Universitet. Bounds on information combining for parity-check equations Land, Ingmar Rüdiger; Hoeher, A.; Huber, Johannes

Accelerating interior point methods with GPUs for smart grid systems

Published in: Proceedings of the Twentieth (2010) International Offshore and Polar Engineering Conference

PIV measurements of flow structures in a spray dryer

INSTITUTTET FOR BYGNINGSTEKNIK DEPT. OF BUILDING TECHNOLOGY AND STRUCTURAL ENGINEERING AALBORG UNIVERSITET AAU AALBORG DANMARK

Published in: Proceeding of 9th SENVAR / 2nd ISESEE, Shah Alam, Malaysia, December 2008

Velocity and Temperature Distribution in Flow from an Inlet Device in Rooms with Displacement Ventilation Jacobsen, T.V. ; Nielsen, Peter Vilhelm

Modelling Salmonella transfer during grinding of meat

Published in: Proceedings of the 17th International Modal Analysis Conference (IMAC), Kissimmee, Florida, USA, February 8-11, 1999

Benchmarking of optimization methods for topology optimization problems

Polydiagnostic study on a surfatron plasma at atmospheric pressure

A comparison study of the two-bladed partial pitch turbine during normal operation and an extreme gust conditions

Published in: 11th International Radiance Workshop, 12 September 2012, Copenhagen, Denmark

Influence of turbulence model on thermal plume in indoor air flow simulation Zelensky, P.; Bartak, M.; Hensen, J.L.M.; Vavricka, R.

Vortex statistics for turbulence in a container with rigid boundaries Clercx, H.J.H.; Nielsen, A.H.

Space charge fields in DC cables

Buoyancy Driven Natural Ventilation through Horizontal Openings Heiselberg, Per Kvols

Realtime 3D stress measurement in curing epoxy packaging

Matrix representation of a Neural Network

The Wien Bridge Oscillator Family

The structure of a nucleolytic ribozyme that employs a catalytic metal ion Liu, Yijin; Wilson, Timothy; Lilley, David

Resistivity imaging for mapping of quick clays

Reflection and absorption coefficients for use in room acoustic simulations

On the Einstein-Stern model of rotational heat capacities

De Prisco, Renato; Comunian, Michele; Grespan, Franscesco; Piscent, Andrea; Karlsson, Anders

Application of mesoscale models with wind farm parametrisations in EERA-DTOC

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Dynamic Effects of Diabatization in Distillation Columns

Global Wind Atlas validation and uncertainty

Impact of the interfaces for wind and wave modeling - interpretation using COAWST, SAR and point measurements

Transcription:

Aalborg Universitet Mathematical Models for Room Air Distribution Nielsen, Peter Vilhelm Published in: System Simulation in Buildings Publication date: 1982 Document Version Accepted author manuscript, peer reviewed version Link to publication from Aalborg University Citation for published version (APA): Nielsen, P. V. (1982). Mathematical Models for Room Air Distribution. n System Simulation in Buildings: Proceedings of the nternational Coonference held in Liége (Belgium) on 6-8 December 1982 (1 ed., Vol. 1, pp. 455-470). Belgium: Commission of the European Communities, COMAC - BME. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.? Users may download and print one copy of any publication from the public portal for the purpose of private study or research.? You may not further distribute the material or use it for any profit-making activity or commercial gain? You may freely distribute the URL identifying the publication in the public portal? Take down policy f you believe that this document breaches copyright please contact us at vbn@aub.aau.dk providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from vbn.aau.dk on: december 01, 2017

NEW ~WAVS TO.,. SA\E ENERGV COMMSSON OF THE EUROPEAN COMMUNTES ~V~T~\11 i:l i:1!;;.lv SMULATON N BULDNGS Proceedings of the nternational Conference held in Liege (Belgium) on 6-8 December 1982 1983 X/ 425/83-EN

Mathematical models for room air distribution Peter V. Nielsen First nternational Conference on "System Simulation in Buildings". Liege, December 1982.

MATHEMATCAL MODELS FOR ROOM AR DSTRBUTON Author Address Peter V. Nielsen Danfoss A/S DK-6430 Nordborg Denmark Summary A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the occupied zone. The paper discusses the important parameters in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. t is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room.

. '. 2 1. ntroduction This paper will deal with some mathematical models describing the air distribution in an air conditioned room with recirculating flow. The examples are only given for two-dimensional flow in t he interest of clarity. The models are restricted to different areas of a ventilated room which is indicated on fig. 1, and several of them are based on the wall jet which is established in the upper part of the room. Area 1 refers to a model which is important because of its proximity to the supply opening. t describes the development of a two-dimensional wall jet from supply openings with different geometries. The wall jet models are restricted to area 2 in fig. 1. One model describes the velocity decay in the wall jet and thus the terminal velocity in a wall jet with a length equivalent to the room l ength. Another model describes the penetration length of a cold wall jet. That is the distance from the supply opening to the area where the jet leaves the ceiling region and flows into the occupied zone. Models in area 3 refer to the determination of the penetration length of the wall jet, and the maximum velocity in the occupied zone. They are mainly based on continuity and momentum _flow considerations and prescribed velocity profiles. Some of them are based on experiments in different room geometries as shown in chapter 3. The flow in the whole room may be predicted by numerical solution of the flow equations, area 4 in fig. 1. This is a complicated procedure but it gives the necessary parameters for a full description of the thermal comfort conditions in the room. 2. Models in the wall jet region The supply opening in fig. 1 is placed close to the ceiling and it has the vertical dimension h. The air flow from t he supply opening will develop into a wall jet which follows the ceiling and entrai ns air f rom the occupied zone to induce a recirculating air movement. This involves a flow many times larger than the supply flow, and the velocity in the wall jet decreases accordingly as it reaches the occupied zone. The velocity decay in the wall jet is given by the formula u X u-= 0 h Kp \ X + X 0 ( 1 ) where U 0 is the bulk supply velocity, Ux the maximum velocity at distance x from the supply opening and x 0 is the distance from the supply opening to a virtual origin of the wall jet, see fig. 2. Equation (1) describes the wall jet in region 2 on fig. 1. The wall jet is established close to the openings in region 1, and it is possible to express all locations and types of diffusers which give two-dimensional flow by the constants x 0 and Kp in equation (1 ). Reference / 1/ gives a discussion of the flow in region 1, and it is shown that the momentum flow in the wall jet is decreased if the supply slot is placed at a distance Yd from the ceiling. This is expressed by a decrease in Kp and an increase in x 0 further downstream from the opening, see fig. 2. A diffuser with vanes adjusted to a high spread or a diffuser giving the flow a high initial turbulence will have the same effect on Kp and x 0 / 1/.

t is also shown that a diffuser consisting of a number of openings placed close to the ceiling may give a virtual origin in front of the diffuser. l The influence of different geometrical parameters on the flow in region 1 is very important because it also influences the velocity Ux in the wall jet and the velocity in the occupied zone, as shown in chapter 3. t is only possible to study the geometrical parameters around the supply openings by full scale experiments on the actual diffusers to be used in the room. A model for the dimensioning of supply openings in the case of isothermal flow is based on equation (1) and area 2. A length, lth, called the throw, is defined as the distance from the opening where the maximum velocity Ux is equal to 0.2 m/s, and equation (1 ) gives: = 25 K 2 u 2 h - X p 0 0 (2) The vertical height of the supply opening and the supply velocity are selected according to equation (2) in such a way that lth is equal to the room length or a fraction of the room length, and it is a general experience that reasonable velocities are obtained in the occupied zone in the case of isothermal flow. The heat load in the room will have an influence on the wall jet. The thickness of a cold wall jet increases with the heat load and the jet may further separate from the ceiling at the distance Xs from the supply opening and flow down into the occupied zone. This will give rise to some limits on the thermal load in the room. The increasing thickness of the wall jet below the ceiling restricts the load in a room with a low ceiling to values which ensure that the velocity in the primary jet part of the occupied zone is below, for example, 0.2 m/s. Thermal comfort conditions may also be evaluated from a minimum penetration depth Xs Hestad /2/ has shown that xs/ h can be expressed by the following equation = K K 2 sp p (3) where ~T 0 is the temperature difference between return and supply and Ksp is a constant expressing the location of the load and room geometry. Fig. 3 shows the variation of Ksp as a function of xs for different distributions of the heat source / 2/. A very high Ksp is obtained when 50% of the load is placed at the wall below the supply opening and the other 50% is concentrated in the middle of the room. The concentrated heat source at the floor will counteract a separation of the jet at this distance and this may explain the maximum in the Ksp value. Hestad recommends a value of 2.5. Ksp is independent of Xs in the case of an evenly distributed heat source along the whole floor. Model experiments by Schwenke / 3/ show that Ksp and x~ are dependent on the room length

and that the flow may have two steady solutions in very short rooms. 3. Models describing the reverse flow area A wall jet will have a limited penetration into a deep room, see fig. 4. Entrainment in the jet means that air must be led back along the bottom of the room and this air will, at a given distance, disperse or deflect the jet. The penetration length lre is defined as the distance from the wall with the supply opening to the point at the floor where the stream lines diverge - the reattachment point (the penetration length lre is defined at isothermal flow ). The velocity is very low at distances from the supply openings which are greater than the penetration length, while the velocities are high at distances less than the penetration length, because large volumes of air are set into motion by the entrainment in the wall jet below the ceiling. The penetration length is therefore an important parameter in the discussion of room air distribution, and a supply system should always be designed in such a way that the ventilated section L is shorter than a calculated penetration length lre at isothermal flow. This would, for example, be ensured in the room in fig. 4 by locating a set of ceiling-mounted supply openings close to the reattachment point. Fig. 5 shows the penetration length measured by model experiments. The penetration length is rather independent of the relative height of the supply opening and the value lre/ H = 4 is obtained by a supply opening with a high K value. Kp values for practical diffusers are often smaller, and the resu~ts in fig. 5 indicate that a lower penetration length will be obtained in those cases. A model based on continuity and momentum flow considerations established by Skaret / 4/ shows that a penetration length lrm' defined as the distance from the supply o~ening to the centre of recirculation, see fig. 4, is proportional to Kp. The maximum velocity in the reverse flow Urm is located close to the floor at a distance of - 2/ 3 L from the supply opening. The occupied zone does not include the j et below the ceiling and the j et at the end wall opposite the supply opening in the normal situation. The velocity Urm will therefore be the maximum velocity in the occupied zone. Experiments and measurements show that Urm is a simple function of a reference velocity UL which is the velocity in an undisturbed wall jet of the length L from the actual supply opening. The reasons for this are that UL contains information on the geometrical details around the diffuser (models in area 1) such as adjustable vanes and distance from ceiling. Fig. 6 shows that Urmi UL is rather constant for practical dimensions of the supply opening CUrmi UL- 0.7 for h/ H < 0.01 ). There is only a slight influence from the relative length of the room, L/ H, and this i s ignored in the figure. Fig. 6 is based on calculations of the twodimensional recirculating flow in reference / 5/ and it is in good agreement with measurements reported in reference / 2/ and / 4/. The results in fig. 6 combined with equation ( 1 ) for a wall jet give the following model for the maximum velocity in the occupied zone of a room with ceiling-mounted diffusers and isothermal flow. u rm -u- = 0 0.7 K p h \ L + X 0 (4)

4. Dimensioning of an air distribution system This chapter sh0ws a dimensioning procedure for the air supply system based on equation (3) and (4 ). The main parameter is the thermal load per m2 of the room Q. This load may be expressed as: (5) where P 0 and cp are density and specific heat respectively. U 0 and ~T 0 can be expressed by Urm and Xs These are more relevant parameters for the evaluation of thermal comfort. Equation ( 3 ) for xs and equation ( 4 ) for Urm are introduced in equation ( 5 ) and the following equation is obtained (x 0 << L) : ( 6 ) This equation is used for a room with an evenly distributed heat source along the whole floor, Ksp' = 1.56, and it is assumed that the penetration length Xs shall be equal to or longer than the half room length, due to comfort considerations, and the following equation is obtained: Q = 1.9. 10 4 max (7 ) u 3 rm -Lwhere Urm and L are in m/ s and m respectively. Equations (6) and (7) show that the thermal load which may be handled is proportional to Ur~ t may thus be concluded that Urm should be as high as acceptable in the case of cooling, and this necess1tates a reduction in supply velocity in the heating season if low air temperatures are used in this period. t is further shown that the maximum thermal load Q varies inversely with the length L of the ventilated section. A high thermal load may thus be handled in cases where the ceiling diffusers are placed at close pitch. Equation (6 ) shows that Xs should be selected as short as possible, but comfort considerations restrict this to about 0.5 L- 0.75 L. The Kp value for the diffuser is not represented in the expression for maximum thermal load. A small Kp means that a high amount of air may be supplied at low velocities in the room, see equation (1), but it means also that the penetration length will be relatively short, see equation (3 ), and the effects will neutralize each other. The results discussed in this chapter are also dependent on room geometry and distribution of thermal load, and only full scale experiments

,. such as the one shown in fig. 10 can give a fully quantitative description of the flow and the thermal comfort in the room, and the 1 maximum thermal load which may be handled. 5. Control strategies based on room air distribution models t is possible to develop some control strategies for the air conditioning system based on the models given in chapters 2 and 3 in cases where heat is removed from the room. Fig. 7 shows the allowed area for U 0 and T 0 Determination of the maximum velocity in the occupied zone according to equation (4) gives the right boundary for the supply velocity shown in the figure. t is assumed that the penetration length Xs shall have a given minimum value and equation ( 3) shows that this corresponds to U 0 2/ AT 0 > const., and this condition gives the left boundary on fig. 7. Fig. 8 sketches a traditional dual duct system. Warm and cold air are supplied to the terminal units where the air is mixed according to the thermostatic control of the supply temperature. t is obvious that the system may have an additional energy consumption due to the mixing of cold and warm air in each terminal unit. The supply velocity is constant and independent of the m~x~ng ratio. Fig. 7 shows that the constant air volume (C.A.V.) gives a control strategy which will keep U 0 and T 0 for each room inside the allowed conditions. t is possible to decrease the energy consumption in the system if the temperature T 0 in the cold duct is controlled fr om the room with the highest load in such a way that this temperature corresponds to the necessary supply temperature ( for example, the upper room in fig. 8). The temperature in the ducts may also be controlled in zones according to the load distribution in the building. Fig. 9 sketches a single duct system. The temperatures are controlled in the rooms by supplying a variable air volumen (V.A.V. ) to each room. Fig. 7 shows that it is more difficult to fulfill the necessary conditions for U 0 and T 0 The penetration length may be too short at low supply velocities, and this is especially the case when the load is high. This problem is often solved by using a diffuser which gives the jet a high penetration in all conditions, such as a diffuser with a variable supply area or a diffuser with additional directing jets. The single duct system is an energy efficient system if reheating of cold air is restricted to a minimum. t is possible to control the temperature T 0 in the supply duct in such a way that all rooms are within the conditions allowed in fig. 7 if the load on each diffuser (ventilated section) varies in a similar manner during the day. 6. Prediction of recirculating flow in a room. The velocity and temperature distribution in a room can be obtained by solving time-average differential equations for the flow by a computerbased numerical method, see reference /1/, /5/ and /6/. This ~ethod gives a complete background for the evaluation of thermal comfort as shown in the example in this chapter. t is a complicated method on a level with model and full scale experiments. Results from the calculation method are given in fig. 10. The measurements shown are related to a geometry with h/ H = 0.0033, L/ H = 1.87 and made as a full scale experiment by Hestad /7/. Comparisons with calculations show that Urm is slightly over-predicted by approximately 10%, but the general velocity pattern i s reproduced. The temperature

distribution is also represented satisfactorily in view of the strong influence of buoyancy in this flow. 7. Conclusions A number of different models on the air distribution in rooms are introduced. The first model describes the importance of the dimensioning and location of the diffusers, and it is based on experiments. Another model gives the velocity decay in the wall jet region of the room and it is further extended to give the throw model, which is used in the traditional dimensioning procedure for supply openings. A model for the maximum velocity in the occupied zone at isothermal flow is given. This model is based on calculations and measurements. The penetration length for a cold jet may be restricted when a large amount of heat is removed from the room by the ventilation system. The amount of heat which may be removed at constant penetration length is proportional to the cube of the maximum velocity in the occupied zone, and it is also shown that a la~ge number of diffusers in a ventilated space increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single duct systems are given, based on the room air distribution models. The paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room, and this method gives the ~ecessary parameters for a full description of the thermal conditions in the room. References 1. Nielsen, P.V., Bestimmung der maximalen Luftgeschwindigkeit in der Aufenthaltszone eines klimatisierten Raumes, Heizung Luftung/ Klimatechnik Haustechnik, No. 9, 1980. 2. Hestad, T., Dimensioning of Supply Openings, Cold Downdraught (in Norwegian), Norsk VVS, No. 6, 1976. 3. Schwenke, H., Das Verhalten ebener horizontaler Zuluftstrahlen im begrenzten Raum, Diss. T.U. Dresden, 1973. 4. Skaret, E., Air Movement in Ventilated Rooms (in Norwegian), nst. for VVS, NTH, Tapir, Trondheim, 1976. 5. Nielsen, P.V., A. Restive and J.H. Whitelaw, The Velocity Characteristics of Ventilated.Rooms, ASME J. Fluids Eng., Vol. 100, 1978, p. 291. 6. Nielsen, P.V., A. Restive and J.H. Whitelaw, Buoyancy-affected flows in ventilated rooms, Numerical Heat Transfer, 2, 1979. 7. Hestad, T., Private communications, Farex Fabrikker A/S, Norway, 1974.

Uo To ~ --- H h j L_ L L ~ -T 0 +6T 0 Fig. 1 Geometry of the room and location of t he areas for the different room air distribution models. h Xo Fig. 2 Geometry of a linear slot diffuser placed at a distance from the ceiling.

Ksp --, 4 r - \ _)"- 3 2 (-}_) 1 0 2 4 6 x 5 [m] Fig. 3 Ksp' describing the i nfluence from the location of the heat source as a function of penetration length / 2/. - Fig. 4 Penetration length in a deep room at i sothermal two-di mensional flow.

l re/h 5 4 - _n_......,.. >J-o-- - ) 3 2 1 0 Kp = 4.1, x 0 /h = 10 c Kp = 3.5, x 0 h = 2 0.0 0.01 0.02 0.03 0.04 0.05 0.06 h / H. Fig. 5 Measurements of penetrat ion length in a deep room at isothermal two-dimensional flow i n the case of different suppl y openings.

Urm UL 1.0 0.8 0.6 _ Uo 0.4 -l 0.2 =1 - ~ 0.0 ih L Urm -- ~ J -,...::::---.. ' ~... -- "'. UL L 0.002 0.004 0.006 0.01 0.02 0.04 0.06 0.1 y d H = 0.0 L H ~ 4 y d H = 0.075 L H < 3 hih Fig. 6 UrmiU L in a r oom with linear s l ot diffuser and isother mal two-dimens i onal fl ow.

To Uo Fig. 7 Allowed area for supply temperature T 0 and supply velocity U 0 in a room.

,-------,,-----, To,1 (""To).----...,...----+~-----. Uo ~ r--- 1 ~-,- - ----~ 1 1 0,2 1 j 1 ~ Fig. 8 Dual duct system. T 0 is the temperature in the cold duct and is a constant supply velocity to the rooms. U 0

,---l r---- 1 r- - 1,..-L---'--,,----------,,------,,...._, T o Uo3 L J. Fig. 9 Single duct system. T 0 is the supply temperature and Uo,1, U 0,2 and U 0,3 are the different supply velocities to the rooms.

Velocity distribution ( crn/s) -... ' \ ( 15 "' :1Q.--- " ' \ 15 \\ J \ - \ \ \ \ \ 15 \ \ J.,.,-/ ( \... _ Predictions ---- Experiments 19 ' '\./ 19 -- -18,5 ' ' ' \ \....._,--- --) _..-- Temperature distribution (0() Fig. 10 Full scale experiments and predictions of the flow in a room. Heat source on a part of the floor area.