Drug Testing Solutions INDIKO DRUG TESTING ANALYZER 1 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Overview Indiko Sample oriented random access system for clinical and specialty testing, like Enzymes, Substrates, Electrolytes & Specific Proteins Drugs of Abuse (DAT), Therapeutic Drug Monitoring (TDM) & Immunosuppressive Drugs (ISD) Ideal for low volume testing needs or as a back-up analyzer Compact, bench-top analyzer 2 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Video Indiko 3 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details - System description Cuvette loader Reagent and sample entry Power switch Cuvette waste Liquid waste Deionized water 4 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details System description (cont.) Incubator - 9 x 10 reaction cells ISE probe Incubator Probe Mixer Cuvette storage - 36 x 10 TENCELL cuvettes Combined sample/reagent disk - max 6 racks 5 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details - Small Footprint 24.4 in/ 62 cm 51 in/ 130 cm with open cover weight 187 lbs/ 85 kg 6 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details Flex. sample & reagent management # of reagent racks # of vials # of sample racks # of samples 1 6 5 45 2 12 4 36 3 18 3 27 4 24 2 18 5 30 1 9 7 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details Supported Tubes and Cups Volume Diameter and Height Rack Position 0.5 ml cup 13 x 25 mm 1-9 2 ml cup 13 x 25 mm 1-9 5 ml tube 13 x 75 mm 1-9 7 ml tube 13 x 100 mm 1-9 10 ml tube 16 x 100 mm 1-9 * 25 mm is the height recommended by Thermo Fisher Scientific. Cup heights are also supported. Note: The test tubes must be non-transparent. If transparent tubes are used, a sticker is needed on the side. 8 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details Accessories & Supplies Item No. Description Size 986000 TENCELLCuvettes 1 box (10,800pcs) 989220 0.5 ml sample cups 1000 pcs 989221 2 ml sample cups 1000 pcs 984050 10 ml reagent bottles 5 pcs 981456 20 ml reagent bottles 16 pcs 984030 Washing solution 4.5% 4 x 20 ml 980929 Washing solution 4.5% 6 x 100 ml 981712 Tubing maintenance solution 20 ml 9 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details Indiko Specifications What is the Indiko Analyzer What comes with the analyzer? Weight Dimensions Fully automated, small size bench-top clinical chemistry analyzer with random access for sample testing Analyzer PC Unit Power cable Mouse 6 sample racks 3 reagent racks One water, one waste (cuvettes) and one waste liquid container One spare water container Need to order separately: Touch screen (each includes keyboard & 2D scanner) Start-up kit Tencell TM Cuvettes 2 ml samples cups 10 ml reagent bottles Washing solution Preventative maintenance kit 187 lbs (85 kg) W 29.5 in (75 cm) D 27.6 in (70 cm) H 24.4 in (62 cm) 10 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details Indiko Specifications Throughput Water consumption Walk-away time Acceptable materials Reagent bottles Reagents/Samples Configuration Sample Types Instrument availability 200 tests/hr (1-Reag. Assays) or ~90 tests/hr (2-Reag. Assays) 1.5 L/hr, no need for external water or drainage connections. Up to 2 hrs Sample Tubes - 5.0, 7.0 or 10.0 primary rubes Sample Cups - 0.5 and 2.0 ml sample cups Cuvettes - TENCELL cuvettes, analyzer specific, have to be ordered from Thermo Fisher Scientific 10 ml or 20 ml round bottles are default bottles. Hitachi 20 ml bottles are acceptable. Currently, our system reagent kits are configured with the 20 ml Hitachi bottles (square) Max 6 racks on-board Mix of 9-position sample racks or 6-position reagent racks Combination of 45 samples or 30 reagents on-board simultaneously Serum, plasma, urine and CSF Instruments will be stocked in Fremont Initially, all instruments will be supplied with 2D barcode scanner 11 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Analyzer Details Indiko Specifications Reporting Options Database Open Channel Availability Water System LIS Software LIS PDF Excel File Printer (printer similar to MGC 240) Currently no database for parameter upload available new instruments will be delivered with open database (200 open channels). Parameters are available by jump drive or email Database upload function planned for future (full package needed). Until the database upload is available and the system is locked (including all reagents are in the Indiko kit configuration) the system will be fully open DI water is required for using with the system Water system will not be sold with the system at this time. If in-house water system is not available, recommend to a customer purchasing 1Gal of purified water from a grocery store ACT is the primary vendor, elabs is the secondary vendor. Pricing approx. $6000 Customer validation in planning as soon as s/w version 4.0 is available 12 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Indiko Technical Specifications Analyzer INDIKO Viva-Jr Viva-E Weight 187 lbs (85 kg) 177 lbs (80 kg) 187 lbs (85 kg) Dimensions W 29.5 in (75 cm) D 27.6 in (70 cm) H 24.4 in (62 cm) W 36 in (89 cm) D 23 in (58 cm) H 24 in (60 cm) - excluding monitor W 45 in (115 cm) D 22 in (56 cm) H 19 in (45 cm) - excluding monitor Reagent Cooling Water Consumption yes yes yes 1.5 L/hr 1.0 L/hr 0.5 L/hr Throughput 90 tests/hour 66 EMIT tests/hour 65 130 EMIT tests/hour Reagent Volume 2 240 µl (1 4 reagents / tests) 0 298 µl & 110 339 µl depending on reagent 0 180 µl & 0 400 µl depending on reagent Sample Volume 2 120 µl 2 30 µl 1 30 µl Sample Tubes Cups 5, 7 or 10 ml tubes & 0.5 or 2.0 ml cups 5 ml tubes & sample cups 5 or 10 ml tubes & sample cups Sample Capacity Reagent Capacity Up to 45 position 25 positions 51 positions Up to 30 positions 18 positions 28 positions 13 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Easy Application Upload & LIS connection Data readable by scanner from barcode - 2D Scanner needed or electronically from a txt - file Application parameters Calibrator and Control values LIS connection using a ASTM protocol Connection to toxicom will be available end of Q1 2012 USA LIS companies customer identified to perform an evaluation 14 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Indiko System Reagents Kit Boxes System reagents will have the Indiko System box blue with white swirl Calibrators and controls reagents will remain in regular white boxes 15 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Benefits of Indiko - General Flexible and easy to use Various tests can be analyzed from each sample Different sample types can be analyzed at the same time Intuitive user interface allows ease of use Automation and operational efficiency True walk-away capability Sophisticated dilution management Fluent and quick daily start up and maintenance procedures Cost-effective, contamination free analysis Low-volume cuvette design enables low reagent usage and low cost per test Disposable cuvettes allow user-safe and contamination free analysis Real-time QC program assures reliable performance 16 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws
Benefits of Indiko - Flexible reporting & full traceability Results are automatically flagged in case of Abnormal values Repeats Out-of-limit control values Reports available Through LIS As printouts Electronically as PDF files Spreadsheet reporting for further calculations Secure and traceable data handling Different user groups can have different access rights Full traceability with long term storage of results including associated calibrations and reagent lot data 17 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws