Thermal and Electrical behaviour of 100 kev N + and Ar + ion implanted Poly( methyl methacrylate) (PMMA) polymer

Similar documents
Study of Electrical and Structural Modifications Induced by 100 kev Argon Ions in Poly(ethylene terephthalate)

Fabrication of micro-optical components in polymer using proton beam micro-machining and modification

Structural Modifications of Gamma Irradiated Polymers: An FT-IR Study

Pelagia Research Library

Optical property modi cation of PMMA by ion-beam implantation

IRRADIATION EFFECTS ON POLY (VINYL CHLORIDE)

SYNTHESIS AND CHARACTERIZATION OF CARBON NANOTUBES USING EGG ALBUMIN BY CHEMICAL METHOD

Study of Neutron Induced Modification on Optical Band Gap of CR-39 Polymeric Detector

References. Adhikari B. and S. Majumdar (2004) Polymers in sensor applications, Prog. Polym. Sci., 29 (7),

In Situ Observation of Damage Evolution in Polycarbonate under Ion Irradiation with Positrons

ABLATION ON POLYMETHYLMETHACRYLATE BY ARGON FLOURIDE EXCIMER LASER ABSTRACT

Conclusion and Future Work

PHYSICAL AND CHEMICAL PROPERTIES OF ATMOSPHERIC PRESSURE PLASMA POLYMER FILMS

Supporting Information. for. Angew. Chem. Int. Ed. Z Wiley-VCH 2003

Gamma Irradiation Effects on Track Properties of PADC-American Acrylics Track Detector

Diffusion of propylene adsorbed in Na-Y and Na-ZSM5 zeolites: Neutron scattering and FTIR studies

Scheme 1: Reaction scheme for the synthesis of p(an-co-mma) copolymer

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

MODIFICATION OF PVC BY ADDITION OF (C + MnO 2 ) AND STUDY OF THEIR ELECTRICAL PROPERTIES

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Chapter 2 Chemistry of High-Energy Charged Particles: Radiations and Polymers

SRIM Simulation of Parameters Affecting Sputtering Yield and Chemical Structure Using Kr, Cu and Pb Ions Bombardment

I. 16. Coloration of Polyethylene Terephthalate (PET) Film by 3MeV Proton Beams

Comparison of the Wehner Spots With Angle Distribution Sputtered Atoms Materials

Secondary Ion Mass Spectrometry (SIMS)

Supporting Information

Ion Conducting Behaviour of Nano Dispersed Polymer Gel Electrolytes Containing NH 4 PF 6

Colombo, Sri Lanka) 3 (Department of Chemistry / University of Sri Jayewardenepura, Sri Lanka) (1)

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Energy fluxes in plasmas for fabrication of nanostructured materials

Photoresist Profile. Undercut: negative slope, common for negative resist; oxygen diffusion prohibits cross-linking; good for lift-off.

Highly charged ion beams applied to fabrication of Nano-scale 3D structures. Sadao MOMOTA Kochi University of Technology

Optical & Spectroscopic Insight into Rheology. SR Kim

Optical and THz investigations of mid-ir materials exposed

Determination of Optical Constants of Polystyrene Films from IR Reflection-Absorption Spectra

ARGON RF PLASMA TREATMENT OF PET FILMS FOR SILICON FILMS ADHESION IMPROVEMENT

High Performance, Low Operating Voltage n-type Organic Field Effect Transistor Based on Inorganic-Organic Bilayer Dielectric System

Radiation Effects on Poly(propylene) (PP)/Ethylene Vinyl Acetate Copolymer (EVA) Blends

Mechanistical studies on the electron-induced degradation of polymethylmethacrylate and Kapton

Resistive switching behavior of reduced graphene oxide memory cells for low power nonvolatile device application

Department of Chemistry, Indian Institute of Technology, Kharagpur , India

RESEARCH ON BENZENE VAPOR DETECTION USING POROUS SILICON

Characterization. Chapter 3: Photo-oxidative degradation in Nylon 66 : Chemical. 3.1 Introduction

POLARIZATION STABILITY OF AMORPHOUS PIEZOELECTRIC POLYIMIDES

Analysis of Poly(dimethylsiloxane) on Solid Surfaces Using Silver Deposition/TOF-SIMS

Qualitative analysis of aramide polymers by FT-IR spectroscopy

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Variation of Refractive Index of PMMA with temperature and different doping % of Tio 2

Synthesis of condensed polynuclear aromatic resin from furfural extract oil of reduced-pressure route II

Change in physico-mechanical and thermal properties of polyamide / silica nanocomposite film

FTIR INVESTIGATION OF THE AGEING PROCESS OF CARBON NANOWALLS

Marine bio-inspired underwater contact adhesion

SURFACE PROCESSING WITH HIGH-ENERGY GAS CLUSTER ION BEAMS

Gamma Radiation Effects on Benzoxazine Monomer: Curing and Thermal Properties

Asymmetrical features of mass spectral peaks produced by quadrupole mass filters

Damage to Molecular Solids Irradiated by X-ray Laser Beam

Influence of temperature and voltage on electrochemical reduction of graphene oxide

Ion Beam Induced Luminescence (IBIL) for scintillator analysis

CHEMICAL POLYMERIZATION OF SUBSTITUTED DERIVATIVES OF ANILINE IN OXALIC ACID MEDIUM

Improved surface properties of PTFE polymer films using broad ion source

Supplementary Information. Core-Shell Silver/Polymeric Nanoparticles-Based Combinatorial Therapy against Breast Cancer In-vitro

Radiation Protection Dosimetry (2006), Vol. 118, No. 3, pp Advance Access publication 6 October 2005

The Kinetics of B-a and P-a Type Copolybenzoxazine via the Ring Opening Process

Effect of decrease in chalcogen content on some physical parameters of Ge 14 Bi x Se 76-x Te 10 Glasses due to variation in Bi content

Beads-On-String-Shaped Poly(azomethine) Applicable for Solution Processing of Bilayer. Devices using a Same Solvent

Radiation and Thermal Effects on the Dielectric Relaxation Properties of PEEK

Research Article. A r t i c l e I n f o. Received 11/5/2016. Accepted 5/10/2016

Metal nanoparticle-doped coloured films on glass and polycarbonate substrates

Curing Properties of Cycloaliphatic Epoxy Derivatives

SURFACE MODIFICATION OF POLYPROPYLENE BY PHOTOGRAFTING OF VINYL ACETATE MONOMERS

Chemistry and Materials Research ISSN (Print) ISSN (Online) Vol.3 No.7, 2013

Improvement of the chemical, thermal, mechanical and morphological properties of polyethylene terephthalate graphene particle composites

Synthesis and Characterization of Grafted Polystyrene with Acrylic Acid Using Gamma-Irradiation

Surface Hydrophilic Treatment of Polyester Films via UV irradiation

Formation of complex films with water-soluble CTAB molecules

Sensitization mechanisms of chemically amplified EUV resists and resist design for 22 nm node. Takahiro Kozawa and Seiichi Tagawa

PERFLUORINATED POLYMER GRAFTING: INFLUENCE OF PRE- IRRADIATION CONDITIONS

Surface Functionalization of a Fluoropolymer by Ion Beam-induced Graft Polymerization of 4-Vinyl Pyridine

Exposure Buildup Factors for Heavy Metal Oxide Glass: A Radiation Shield

The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements

Infrared Spectroscopy. Provides information about the vibraions of functional groups in a molecule

INVESTIGATIONS OF THE EFFECTS OF UV IRRADIATION ON THE ETCHING BEHAVIOR OF CR-39 SOLID STATE NUCLEAR TRACK TSE CHUN CHUN

Molecular depth profiling with reactive ions, or why chemistry matters in sputtering.

Gestão e Produção Sustentável. Durability Electromagnetic radiation. ENG K49 Materiais de origem vegetal aplicados na construção

Dendritic Star Polymer of Polyacrylamide Based on β-cyclodextrin Trimer: A. Flocculant and Drug Vehicle

Keywords: mechanical property, polymer optical fibre, radiation, transmission.

Optical Characterization of Sucrose (C 12 H 21 O 11 ) at Different Temperatures

Preparation and Characterization of Hydrogels

Supplementary Figure 1 Detailed illustration on the fabrication process of templatestripped

Poly(phenyl acrylate) and Poly(p-methylphenyl acrylate) as photostabilizers II. Protection of PET against photo-oxidation

MAGNETORESISTIVITY OF COBALT-PTFE GRANULAR COMPOSITE FILM PRODUCED BY PULSED LASER DEPOSITION TECHNIQUE

Infrared Spectroscopic Study of the Interactions of Nylon-6 with Water

Physiochemical properties of crystalline etch products for CR-39 track detector after α-particles irradiation

High-Precision Evaluation of Ultra-Shallow Impurity Profiles by Secondary Ion Mass Spectrometry

Supporting Information

Diamond-like carbon film deposition on PZT ferroelectrics and YBCO superconducting films using KrF excimer laser deposition

and Technology, Luoyu Road 1037, Wuhan, , P. R. China. *Corresponding author. ciac - Shanghai P. R.

STRUCTURAL AND OPTICAL CHARACTERIZATION OF PMMA SURFACE TREATED IN LOW POWER NITROGEN AND OXYGEN RF PLASMAS

7 Wettability of 60 kev Ar-ion irradiated rippled-si surfaces

Plasmonic Hot Hole Generation by Interband Transition in Gold-Polyaniline

Transcription:

Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2012, 3 (5):2766-2773 ISSN: 0976-8610 CODEN (USA): AASRFC Thermal and Electrical behaviour of 100 kev N + and Ar + ion implanted Poly( methyl methacrylate) (PMMA) polymer Renu Gupta a*, V. Kumar a, P. K. Goyal a, Shyam Kumar a and Sneh Lata Goyal b a Department of Physics, Kurukshetra University, Kurukshetra 136119, India b Department of Applied Physics, Guru Jambheshwar University of Science and Technology, Hisar 125001, India ABSTRACT Poly (methyl methacrylate) (PMMA) samples were implanted with 100 kev N + and Ar + ions at fluence upto 2x10 16 ions/cm 2. Ion implantation induced modifications have been observed in the thermal as well as electrical behaviour of PMMA. Thermogravimetric analysis reveals an increase in the thermal stability and hence an increasing trend in the values of thermal degradation energy as a consequence of ion implantation for both the ions has been obtained. Electrical conductivity behaviour shows an increase in the values of conductivity in the implanted samples of PMMA. Structural rearrangements as revealed through FTIR spectroscopy were found to be in strong association with the observed changes in thermal and electrical behaviour of PMMA. Keywords: PMMA, ion implantation, activation energy, electrical conductivity, FTIR INTRODUCTION In today s era of science and technology, there is a basic need of more and more performing materials. Polymers, in this respect, prove to be excellent engineering materials because of their excellent inherent properties alongwith their tunability by various modes [1-7]. PMMA has emerged as one of the promising material, widely studied and extensively utilized in various applications [8-11]. Owing to its light weight, optical transparency, mechanical strength etc it provides an adequate substance to be utilized in aerospace applications [12-16]. In this arena, PMMA must not only provide excellent mechanical properties but it should also retain its chemical inertness, electrical behaviour after exposure to high levels of radiations. Good thermal stability is also appreciable for polymers to be utilized in various applications. In the present study, we have emphasized on the modifications produced in the thermal and electrical conductivity behaviour of PMMA as an effect of ion implantation. An attempt has been made to investigate the mechanisms of alterations produced in the polymeric sample due to ion implantation. MATERIALS AND METHODS 2.1 Sample preparation The samples (1cm x 1cm) of PMMA (Goodfellow, UK) were cut from a flat sheet of thickness 500 µm and subjected to implantation of 100 kev N + and Ar + ions using Low Energy Ion Beam Facility (LEIBF) available at Inter University Accelerator Centre (IUAC), New Delhi, India. The irradiation of these samples was performed at 2766

room temperature under high vacuum (~10-6 torr) upto a maximum dose of 2x10 16 ions/cm 2. The beam current density was kept low in order to avoid thermal degradation during ion implantation. The average projected range of the implanted ions has been found to be 342 nm and 148 nm for N + and Ar + ion, respectively in PMMA, as calculated using SRIM code (version 2008.04). 2.2 Measurements and characterization Thermal behaviour has been studied by thermogravimetric analysis using Q600 TA Instrument. Thermograms for the pristine as well as implanted samples were recorded at a linear heating rate of 10 C/min, in the temperature range ~30-600 C. The DC current voltage measurements of pristine and ion implanted samples of PMMA were carried out in the voltage range 0 to 100 V at room temperature using Keithley 6517 digital programmable electrometer interfaced with computer. In order to ensure good electrical contacts, the samples were silver coated with a certain gap between the two electrodes. To reveal the structural changes due to ion implantation, the pristine and ion implanted PMMA samples were subjected to FTIR spectroscopic analysis using Shimadzu IR-Affinity-I, FTIR Spectrometer equipped with specular reflectance accessory (Shimadzu, SRM-8000A) and ATR accessory (Pike, ATR-MAX-II with Ge crystal). RESULTS AND DISCUSSION 3.1 Thermal behavioural studies 3.1.1 Thermogravimetric analysis Thermogravimetric Analysis (TGA) is a potential means to determine the influence of polymer morphology on thermal stability through the process of thermal degradation. Various kinetic parameters related to the degradation process such as activation energy, frequency factor, free energy of decomposition, entropy of activation, rate coefficient etc. can be obtained using this technique [17-19]. In order to investigate the effect of ion implantation on these kinetic parameters, TGA and DTG thermograms (Figure 1(A) and 1(B)) of the pristine PMMA and TGA thermograms of 100 kev N + and Ar + ion implanted samples (Figure 2(A) and 2(B)) of PMMA at different ion fluences have been recorded. Figure 1: (A) TGA; (B) DTG thermograms of pristine PMMA. 2767

Figure 2: TGA thermograms for (A) N + and (B) Ar + ion implanted PMMA It can be clearly seen from figure 1(A) and 1(B) that thermal degradation of pristine PMMA takes place in four steps [20-21] which may be associated to different processes of degradation. The first step falls in the temperature range 0-150 C remains almost stable upto a temperature of 110 C at which initial degradation starts. This is associated with the radical transfer to the unsaturated chain end. The second step in the temperature range 150-230 C and the third step upto a temperature of 320 C may be due to homolytic scission of chains due to H-H bonds and free radical transfer in the unsaturated chain ends, respectively. The second and the third steps are more or less coupled to each other as the hemolytic scissions of the chain may produce free radicals which initiate the third step degradation process. The fourth and the main step of the degradation process extends upto 410 C and is associated with random scissions. Beyond this temperature a residual mass is left out. Figures 2(A) and 2(B) clearly show a gradual increase in the thermal stability of ion implanted samples with increasing ion fluences. It can also be seen that the changes produced are more prominent in the case of N + ion implantation as compared to that for Ar + ion implantation which can further be confirmed by kinetic analysis. 3.1.2. Kinetic analysis a) Determination of activation energy The TGA thermograms have been used to evaluate various kinetic parameters of the degradation reaction by adopting most commonly used method of Horowitz Metzger [17, 19-27]. The activation energies of pristine and ion implanted samples of PMMA corresponding to the main step of degradation process have been evaluated using the expression [26] = (1) where w 0 is the initial weight, w is the remaining weight at temperature T, w f is the final weight, E a is the activation energy, R is gas constant and θ = T-T s with T s as the reference temperature corresponding to w/w 0 = 1/e. The activation energy E a can be calculated from the slope of the linear fitted line between ln(ln(w 0 -W f / W-W f )) and θ as illustrated in Figure 3(A) and 3(B) for N + and Ar + ion implanted samples respectively, alongwith the pristine sample and these values are tabulated in Table 1. b) Determination of frequency factor The corresponding values of frequency factor for the pristine and the ion implanted samples of PMMA have been determined by substituting the values of activation energies in the expression [26] 1= (2) 2768

where A is the frequency factor and β is the constant rate of heating. Figure 3: Plots of ln(ln(w o-w f/w-w f)) vs temperature for (A) N + and (B) Ar + ion implanted PMMA. The values of frequency factor, so determined for pristine as well as ion implanted samples of PMMA have been enlisted in Table 1. An increasing trend has been observed in the values of activation energy as well as the frequency factor with the increasing ion fluence. Such an increase in the values of activation energy may be attributed to the initialization of cross-linking, possible enhancement in the packing density due to carbonization, compactness, reorganization of molecular arrangements etc. in the polymeric sample which signifies the increase in thermal stability of the polymer. Corresponding to the increase in values of activation energy, the values of frequency factor also increases. Such an increment in the values of frequency factor signifies the enhanced rate of reaction. This may be due to the formation of some interstates as a result of cross-linking or carbonization which increases the reaction rate as an effect of ion implantation [19-23]. The observed values of various kinetic parameters (Table 1) clearly indicate that the extent of changes produced in the case of N + implanted PMMA is more pronounced than that produced due to Ar + implantation in PMMA. This can be justified by considering the range of these ions in PMMA polymer. As already mentioned, the range of these ions have been found to be 342 nm and 148 nm for N + and Ar + ion in PMMA respectively, at the same energy (100 kev) of the incident ion. Since N + ion has impinged PMMA deeply as compared to Ar + ion in the host polymer, hence, the modifications produced due to ion implantation are more prominent in the case of N + ion as compared to Ar + ion [11-15, 22]. 3.2 Electrical studies 3.2.1 DC Conductivity The current-voltage plots were recorded for pristine as well as N + and Ar + ion implanted samples of PMMA in the voltage range 0-100V and are presented in figures 4(A) and 4(B), respectively. It can be clearly seen from these figures that the current raises gradually with the increasing ion fluence for both ions. From this data, the surface conductivity of pristine and implanted PMMA samples has been calculated using the relation [28-29] given below and presented in Table 1.! = "#$h &' ( ( ) 2) (3) * where, σs = surface conductivity, d = separation between electrodes, r 0 = radius of the circular electrode, R = resistance measured through the I-V measurements on the implanted surface. Figure 5 presents the variations in conductivity with respect to the ion fluence for both N + and Ar + ion implanted samples of PMMA and the corresponding values have been enlisted in table 1. 2769

Figure 4: Plots of current vs voltage for (A) N + and (B) Ar + ion implanted PMMA. Figure 5: Plots of conductivity vs ion fluence for N + and Ar + ion implanted PMMA. It is clear from figure 5 that initially the conductivity values for N + and Ar + ion implanted PMMA are almost of same order upto a dose of 1x10 16 ions/cm 2 and afterwards, conductivity values for N + ion implantation rises drastically compared to that for Ar + ion implantation at ion fluence to 2x10 16 ions/cm 2. This can be suggested to be due to the large penetration depth of N + ion as compared to that of Ar + ion at same energy of incident ion. Further, the observed changes in the conductivity of ion implanted PMMA may be due to the incorporated structural changes as an effect of ion implantation. The possible carbonization, compactness, cross-linkage in the ion implanted PMMA may be responsible for the enhanced conductivity of ion implanted PMMA [28-29]. These structural changes are confirmed through FTIR spectroscopy. 2770

3.3 FTIR Spectroscopy FTIR spectroscopy is a powerful tool for identifying the bonding structure of polymers. Figure 6 presents the FTIR spectrum of virgin PMMA. It exhibits various peaks at different wavenumbers which may be assigned to different bonding parameters using the available literature [30-32]. Figure 1: FTIR spectra of virgin PMMA. The major absorption peak at 1732 cm -1 corresponds to the C=Orbital stretching vibrations owing to free carbonyl group present in PMMA. The peaks in the region 1060-1270 cm -1 represents C-O-C stretching vibrations. In particular, the peaks at 1066, 1150 cm -1 exhibit symmetric C-O-C stretching, while those at 1190, 1242, 1270 cm -1 corresponds to antisymmetric C-O-C stretching mode. The smaller peaks in the wavenumber range 910-989 cm -1 shows O-CH 3 rocking, while the peak at 842 cm -1 is due to CH 2 rocking vibrations. The peak at 752 cm -1 may be attributed to C-O bending. All these peaks confirms the monomer structure of PMMA [30-32]. The modifications in the polymeric sample can be clearly observed from the FTIR spectra of N + and Ar + ion implanted PMMA (figure 7). There is a gradual reduction in the intensities of all the peaks with increasing ion fluence. Some of the peaks in the region (700-1000) cm -1 have started dissappearing. All these changes indicate the removal of hydrogen like specices, formation of compact carbonaceous structures etc in the implanted samples of PMMA. All these structural changes support the observed modifications in thermal and electrical behaviour of the polymeric sample as an effect of ion implantation. / Figure 7: FTIR spectra for N + and Ar + ion implanted PMMA. 2771

Table 1: List of parameters of thermal stability and electrical conductivity of virgin and ion implanted PMMA. S. No. Ion fluence (ions/cm 2 ) Activation Frequency factor (s Energy (kj/mol) N + Ar + -1 DC Conductivity ) N + Ar + (siemen/cm) N + Ar + 1. Virgin 224.1 224.1 5.7E17 5.7E17 1.1E-14 1.1E-14 2. Ix10 16 259.4 249.7 1.1E20 4.7E19 2.3E-11 7.6E-11 3. 2x10 16 261.7 253.8 4.3E20 5.1E19 2.7E-10 5.9E-11 CONCLUSION The observed variations in thermal stability and electrical conductivity of ion implanted PMMA may lead to tailor the polymeric sample to suit specific requirments. An increased electrical conductivity of the sample coupled with an enhanced thermal stability as an effect of ion implantation may find extensive applications in various elecronic and opto-electronic devices. Acknowledgement The authors are thankful to Dr. D. Kanjilal, IUAC, New Delhi, for valuable discussions. Thanks are due to Dr. P. Kumar, IUAC for helping during irradiation. One of the authors (P.K. Goyal) is thankful to CSIR, New Delhi for financial assistance in form of SRF. REFERENCES [1] F. W. Billmeyer Jr. Textbook of Polymer Science; Wiley Interscience: New York (2005). [2] M. F. Zaki J. Phys. D: Appl. Phys. 41 (2008), 1754-1758. [3] E. H. Lee Nucl Instrum Methods B 151 (1999), 29-41. [4] W. Hong, H. J. Woo, H. W. Choi, Y. S..Kim, G.D. Kim Appl. Surf. Sci. 169-170 (2001), 428-432 [5] T. Sharma, S. Aggarwal, A. Sharma, S. Kumar J. Appl. Phys. 102 (2007), 063527-1-4. [6] R. M. Radwan, A. M. Abdul-Kader, A. El-Hag Ali Nucl. Instrum. Methods Phys. Res. B 266 (2008), 3588-3594. [7] D. Fink (Ed.), Fundamentals of Ion-Irradiated Polymers, Springer-Verlag, Berlin, Heidelberg, (2004). [8] S. R. Tatro, G. R. Baker, K. Bisht, J. P. Harmon Polymer 44 (2003), 167 176 [9] G.B. Hadjichristov, V. Ivanov, E. Faulques Appl. Surf. Sci. 254 (2008), 4820 4827 [10] C. T. Lin, S.W. Kuo, C. F. Huang, F.C. Chang Polymer 51 (2010), 883-889. [11] D. Dorranian, Z. Abedini, A. Hojabri, M. Ghoranneviss J. Non-oxide Glasses 1, 3 (2009), 217-229. [12] S. W. Kuo, H. C. Kao, F.C. Chang Polymer 44 (2003), 6873-6882. [13] A. V. Leontyev, V. I. Kovalev, A. V. Khomich, F. F. Komarov, V. V. Grigoryev, A. S. Kamishan Micro- and Nanoelect (2003), Proceedings of SPIE Vol 5401. [14] J. R. Kulish, H. Franke, A. Singh, R. A, Lessard, E. J. Knystautas J. Appl. Phys. 63 (1988), 2517. [15] W. He, K. E. Gonsalves, N. Batina, D. B. Poker, E. Alexander, M. Hudson Biomed Microdev 5:2 (2003), 101-108. [16] Y. Koval J. Vac. Sci. Tech. B 22, 2 (2004), 843-851. [17] P. C. Kalsi, K. D. S. Mudher, A. K. Pandey, R.H. Iyer Thermochimica Acta 1995, 254, 331-336. [18] H. H. G. Jellinek Aspects of Degradation and Stabilization of Polymers; Elsevier Scientific Publishing Company : New York, 1978. [19] M. F. Zaki, Brazilian J. Phys. 38, 4, 2008, pp558-562. [20] M. Ferriol, A. Gentilhommea, M. Cocheza, N. Ogetb, J.L. Mieloszynskib Polymer Degradation and Stability 79, 2003, 271 281. [21] L. E. Manring, D. Y. Sogah, G. M. Cohen. Macromolecules 1989,22:4652 4. [22] J. H. Flynn, L.A. Wall J. Research of NBS-A Phy. and Chem. 1966, 70A(6), 487-523. [23] K. G. Mallikarjun E-Journal of Chem. 2004, 1(2), 105-109. [24] M. R. Rizzatti, M.A. Araujo, R. P. Livi Nucl. Instrm. And Meth in Phys Res B 174, 2001, pp 475-481. [25] B. K. Singh, P. Kumari, A. Prakash, D. Adhikari Nature and Science 2009, 7(7), 73-78. [26] H. H. Horowitz, G. Metzger Anal. Chem. 1963, 35(10), 1464-1468. [27] R. Gupta, V. Kumar, P. K. Goyal, S. Kumar, P.C. Kalsi, S. L. Goyal, Advances in Applied Science Research, 2011, 2 (1): 248-254 [28] P.K. Goyal, V. Kumar, Renu Gupta, S. Mahendia, Anita, S. Kumar Vaccum XXX, 2011, 1-5. 2772

[29] P.K. Goyal, V. Kumar, Renu Gupta, S. Mahendia, T. Sharma, S. Kumar, Advances in Applied Science Research, 2011, 2 (3): 227-231 [30] E. V. Anslyn, D. A. Dougherty Modern Physical Organic Chemistry; Edwards Brothers, Inc. USA, 2006. [31] D. L. Pavia, G. M. Lampman, G. S. Kriz Introduction to Spectroscopy 2 nd ed. New York, Harcourt Brace College Publishers, 1994. [32] D. Campbell, R. A. Pethric, J. R. White Polymer Characterization:Physical Techniques (2 nd Ed.), Stanley Thornes, UK, 2000 2773