Improvement of Low Strain Pile Integrity Test

Similar documents
2040. Damage modeling and simulation of vibrating pipe with part-through circumferential crack

Static Pile Head Impedance using 3D Nonlinear FEM Analysis

Chapter 3. Load and Stress Analysis

Interpretation of Pile Integrity Test (PIT) Results

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

SURFACE WAVE MODELLING USING SEISMIC GROUND RESPONSE ANALYSIS

DETERMINING THE STRESS PATTERN IN THE HH RAILROAD TIES DUE TO DYNAMIC LOADS 1

NON-DESTRUCTIVE EVALUATION METHODS FOR COMPOSITE PILES

Numerical study on scanning radiation acoustic field in formations generated from a borehole

Understanding Dynamic Pile Testing and Driveability

ON THE PREDICTION OF EXPERIMENTAL RESULTS FROM TWO PILE TESTS UNDER FORCED VIBRATIONS

GEO-SLOPE International Ltd, Calgary, Alberta, Canada Wick Drain

Lesson 25. Static Pile Load Testing, O-cell, and Statnamic. Reference Manual Chapter 18

NON-LINEAR ANALYSIS OF SOIL-PILE-STRUCTURE INTERACTION UNDER SEISMIC LOADS

Experiment and Finite Analysis on Resonant Bending Fatigue of Marine Risers

VERTICAL VIBRATION ANALYSIS OF MANHOLE UNDER TRAFFIC LOADING

93. Study on the vibration characteristics of structural of hydrocyclone based on fluid structure interaction


Macroscopic Elastic Constitutive Relationship of Cast-in-Place Hollow-Core Slabs

KINK BAND FORMATION OF FIBER REINFORCED POLYMER (FRP)

Numerical simulation on ground vibration caused by the demolition of a 200 m high chimney

Strength Study of Spiral Flexure Spring of Stirling Cryocooler

Research of a novel fiber Bragg grating underwater acoustic sensor

EFFECT OF BOUNDARIES ISOLATION ON DYNAMIC RESPONSE OF PILE GROUPS

Influence of the Soil Structure Interaction on the Fundamental Period of Large Dynamic Machine Foundation

LECTURE NO. 4-5 INTRODUCTION ULTRASONIC * PULSE VELOCITY METHODS

BENCHMARK LINEAR FINITE ELEMENT ANALYSIS OF LATERALLY LOADED SINGLE PILE USING OPENSEES & COMPARISON WITH ANALYTICAL SOLUTION

CWR track vibration characteristics varying with the change of supporting condition

Dynamic Analysis of Pile Foundations: Effects of Material Nonlinearity of Soil

FATIGUE BEHAVIOUR OF OFFSHORE STEEL JACKET PLATFORMS

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

Element size effect on the analysis of heavy-duty machine cross-rail Jianhua Wang1,Jianke Chen1,a,Tieneng Guo1 Bin Song 2, Dongliang Guo3

ERTH2020 Introduction to Geophysics The Seismic Method. 1. Basic Concepts in Seismology. 1.1 Seismic Wave Types

Seismic Analyses of Concrete Gravity Dam with 3D Full Dam Model

Borehole deformation under a stressed state and in situ stress measurement

EXAMPLE OF PILED FOUNDATIONS

Rock fragmentation mechanisms and an experimental study of drilling tools during high-frequency harmonic vibration

Research on the Concrete Dam Damage and Failure Rule under the Action of Fluid-Solid Coupling

Compensation-based non-destructive automatic quality control using acoustic methods

Sound Propagation in Porous Media

VIBRATION CONTROL OF RECTANGULAR CROSS-PLY FRP PLATES USING PZT MATERIALS

Finite Element Modeling of Ultrasonic Transducers for Polymer Characterization

the tests under simple shear condition (TSS), where the radial and circumferential strain increments were kept to be zero ( r = =0). In order to obtai

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

The Simulation of Dropped Objects on the Offshore Structure Liping SUN 1,a, Gang MA 1,b, Chunyong NIE 2,c, Zihan WANG 1,d

7.2.1 Seismic waves. Waves in a mass- spring system

Mechanical Engineering Ph.D. Preliminary Qualifying Examination Solid Mechanics February 25, 2002

Lecture #2: Split Hopkinson Bar Systems

Foreign Object Damage to Fan Rotor Blades of Aeroengine Part II: Numerical Simulation of Bird Impact

SEISMIC RESPONSE OF INDUSTRIAL STRUCTURES CONSIDERING SOIL-PILE-STRUCTURE INTERACTION

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

Multi-station Seismograph Network

FATIGUE LIFE PREDICTIONS FOR ASPHALT CONCRETE SUBJECTED TO MULTIPLE AXLE LOADINGS

Sound Propagation through Media. Nachiketa Tiwari Indian Institute of Technology Kanpur

SECTION A. 8 kn/m. C 3 m 3m

BACKGROUND AND INTRODUCTION

The Influence of Contact Friction on the Breakage Behavior of Brittle Granular Materials using DEM

Feasibility of dynamic test methods in classification of damaged bridges

Research of concrete cracking propagation based on information entropy evolution

PRACTICAL THREE-DIMENSIONAL EFFECTIVE STRESS ANALYSIS CONSIDERING CYCLIC MOBILITY BEHAVIOR

NON-LINEAR VISCOELASTIC MODEL OF STRUCTURAL POUNDING

Study and design of a composite acoustic sensor to characterize an heterogeneous media presenting a complex matrix

New hydro-mechanical tunnel excavation method using an abrasive waterjet system

Study on Settlement Prediction Model of High-Speed Railway Bridge Pile Foundation

IZMIT BAY BRIDGE SOUTH APPROACH VIADUCT: SEISMIC DESIGN NEXT TO THE NORTH ANATOLIAN FAULT

Experimental Research on Ground Deformation of Double Close-spaced Tunnel Construction

Physical and Biological Properties of Agricultural Products Acoustic, Electrical and Optical Properties and Biochemical Property

NUMERICAL AND EXPERIMENTAL STUDY OF FAILURE IN STEEL BEAMS UNDER IMPACT CONDITIONS

NON-LINEAR ATTENUATION IN SOILS AND ROCKS

Influence and analysis of escape posture for different launch tube spiral angles

Laboratory 4 Bending Test of Materials

Application of Thermal Stress Device for Measuring Thermal Stresses

Engineering Science OUTCOME 1 - TUTORIAL 4 COLUMNS

Cantilever Beam Crack Detection using FEA and FFT Analyser

ICSV14 Cairns Australia 9-12 July, 2007

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

Effect of Displacement Loading Rate on Mechanical Properties of Sandstone

Differential Acoustic Resonance Spectroscopy Analysis of Fluids in Porous Media

Experimental Study of Seismic Soil-Structure Interaction by using Large Geotechnical Centrifuge System

THEME A. Analysis of the elastic behaviour of La Aceña arch-gravity dam

To initiate a dynamic analysis in FormWorks, the Analysis Mode in the JOB CONTROL tab of DEFINE JOB window has to be set to one of the two Dynamic

Thermal-optical property of fore optical system in space hyper spectral imager

Detection and Survey of Interface Defects Within a Pavement Structure with Ultrasonic Pulse Echo

Determination of Poisson s Ratio of Rock Material by Changing Axial Stress and Unloading Lateral Stress Test

On the study of elastic wave scattering and Rayleigh wave velocity measurement of concrete with steel bar

The study of ultrasonic pulse velocity on plain and reinforced damaged concrete

Possibilities of Using COMSOL Software in Physics

Effect Of The In-Situ Stress Field On Casing Failure *

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

DEPARTMENT OF MECHANICAL ENIGINEERING, UNIVERSITY OF ENGINEERING & TECHNOLOGY LAHORE (KSK CAMPUS).

Severe accident risk assessment for Nuclear. Power Plants

Module 3 : Equilibrium of rods and plates Lecture 15 : Torsion of rods. The Lecture Contains: Torsion of Rods. Torsional Energy

Structural Health Monitoring Using Peak Of Frequency Response

INFLUENCE OF A WELDED PIPE WHIP RESTRAINT ON THE CRITICAL CRACK SIZE IN A 90 BEND

Supplementary Information. Multifunctional graphene woven fabrics

Chapter 5 Torsion STRUCTURAL MECHANICS: CE203. Notes are based on Mechanics of Materials: by R. C. Hibbeler, 7th Edition, Pearson

Hydraulics Prof. Dr. Arup Kumar Sarma Department of Civil Engineering Indian Institute of Technology, Guwahati

Physical Science and Engineering. Course Information. Course Number: ME 100

CHAPTER -6- BENDING Part -1-

Transcription:

Improvement of Low Strain Pile Integrity Test Wenzhang Luo 1, Fan Chen 2, and Junling Hu 1 1 Deparment of Mechanical Engineering, University of Bridgeport, Bridgeport, CT 06604 2 National Center for Quality Supervision and Test of Building Engineering, Beijing 100013, China Abstract The low strain pile integrity test (LSPIT) is currently the most widely used method of pile integrity testing. This paper studied stress wave propagation in piles in engineering tests with finite element method (FEM). From the numerical calculation results and test signals, a location of two thirds of radius away from the source (center point) for solid piles or a distance of 90 arc away from the source for pipe piles on the top face is found to be the best location to place a sensor. The high frequency disturbing signal diminishes greatly at the recommended location when the load impulse is applied. The time difference between initial velocity signals was then studied at different locations to correct the vertical wave velocity and defect depth in some situation. Introduction The low strain pile integrity test (LSPIT) is a Non-Destructive integrity test method for foundation piles, especially concrete piles and concrete filled pipe piles. Millions of piles were built in the construction field every year in China. As it is convenient to use LSPIT in construction filed and the cost involved is also low, LSPIT is widely adopted by most construction companies. The LSPIT is based on the wave propagation theory of the compression wave generated by a small impact. The compression wave travels down the pile at a constant wave speed and was reflected by changes in cross sectional area or material in concrete. The pile can be considered as a one-dimensional elastic bar if it can satisfy two conditions. The first condition requires the wavelength of the incoming wave to be at least 10 times of the pile diameter to ensure planar wave will occur in the pile. The second condition requires the wavelength to be much smaller than the pile length to reduce the effect of rigid body motion of the pile. Usually the test is performed by applying an accelerometer at the pile top surface where a light impact is applied by a small hand held hammer. Then a compressive stress wave travels down the pile at a constant wave speed c, which is a function of the elastic modulus E and mass density m. Given a known stress wave speed or pile length, records of velocity (integrated from the accelerometer signals) can be interpreted to reveal pile non-uniformities (changes in impedance). The impedance is a function of the cross sectional area, the modulus of elasticity, the wave speed in the pile material and of the soil damping. Interpretation is 1

usually done in the time domain (pulse echo) but data can also be evaluated by analyzing in the frequency domain. Many factors influence the quality of the result produced by this test method such as the competence of the personnel performing it, and the suitability of the equipment and facilities used etc. In this paper, the locations of accelerometer on the pile head were studied based on the numerical calculation analysis and test signals. It was found that locations of the accelerometer can affect the test results. The influences of the location on the results will be discussed and appropriate locations of accelerometer will be recommended for better test results. Numerical Model Finite element method (FEM) was used to analyze the model. Fig.1 is the FEM mesh of a pipe pile head. Newmark method is used to solve the dynamic equations. The following assumptions were made in the model: 1. The influence of the surrounding soil on the pile is neglected. The pile is considered as a homogeneous body with no constraints. 2. Gravity is neglected in the dynamic equations. 3. Damping is neglected in the pile. 4. The computational domain is considered elastic in the process. Fig.1 FEM mesh of pipe pile head Hammer impact point Accelerometer point Numerical damping is considered in case of the pipe pile to reduce the high frequency disturbance caused by the FEM mesh, which also reduced the useful high frequency wave and the reflection echo from the pile end. Numerical Calculation Results Two common pile styles are selected as the samples: a solid pile with diameter of 1.0 m 2

(Φ1.0m) and a pipe pile with outer diameter of 900 mm and inner diameter of 110 mm (Φ800 110mm). Similar results can be obtained for other types of piles, but the results will not be shown here. The load impact point is at the center of the top surface for the Φ1.0m solid pile. The load impact point for the Φ800 110mm pipe pile is shown in Fig. 1. The accelerometer can be placed anywhere on the top surface, but the test results will be different for each location, as shown in Figs. 2-3. Fig. 2 Computed velocity at different locations along the radial direction of a Φ1.0m solid pile(l=10.0m) Fig. 3 Computed velocity at different locations of a Φ800 110mm pipe pile (L=13.0m) Suitable Locations to Place an Accelerometer The high frequency waves that is not caused by the defects in the actual signals affect the evaluation of the test results and, thus, is called disturbing high frequency content.. Generally when the piles was impacted, the longitudinal and transverse vibrations modes mixed together to produce the disturbing high frequency content. The disturbing high frequency content should be diminished for better signals. In Figs. 2 to 4, the disturbing high frequency content is weaker than at other points on the top 2 surface when it is at the point of R away from the source (center point) for solid piles or a 3 point which forms a 90 angle with the source point for pipe piles. These two locations are recommended to place an accelerometer. 3

The frequency domain of the results in Fig. 3 is shown in Fig. 4 for two locations: at 90 point and 135 point. The frequency domain of the results at the 45 point and at 180 point are similar to that at the 135 point. It can be inferred they are influenced by different vibration mode. The signal at the 90 point is not influenced by the 1 st transverse vibration mode as that at other points. Hence, the disturbing high frequency content is easier to diminish at 90 point when a suitable impact shape is applied. The actual test signals showed the same pattern in Fig. 5 (a) 90 point (b) 135 point Fig. 4 Frequency domain of Fig. 3. Fig5 Test velocity curve and its frequency domain at different points of Φ800 110mm pipe pile (L=13.0m) The results for the solid pile are the similar to those in the pipe piles. [1] The results here are especially helpful for the pile with big radius, which might fail to detect defects when the final test signal has the disturbing high frequency content. Stress Wave Propagation at the Top Surface and its Influences After the impact on the top surface of the pile, the longitudinal, transverse and surface waves propagated in the pile body and reflected back on the boundary. All the stress waves mixed together and influenced the final velocity signal. From Fig. 2 and Fig. 3, it is apparent that the peak value of the impact impulse varies with the location and time to collect the signal. However, the peak value and its time to reach the peak value of the reflection impulse from the pile end do not vary with the location of the accelerometer. A formula is obtained to calculate the time to receive the impact impulse peak at different locations from the 4

numerical results and actual test signals. For solid pile, the time of the impact pulse to reach the peak velocity at the location of accelerometer can be calculated by [1] t = t r / (1) 0 + where t 0 is the time of the impact pulse to reach the peak velocity at the impact point (center), r location of the accelerometer, c R is the surface wave velocity. For pipe pile, the time of the impact pulse to reach the peak velocity at the location of accelerometer can be calculated by c R c R θπr t = t 0 + (2) 180 R = ( R ) / 1 + R2 2 where R 1 and R 2 are the inner and outer radius of the pipe pile and θ is the angle formed between the impact point and the point to place the accelerometer at the pipe center. Equation (3) is used to calculate the longitudinal wave velocity: c = 2 L / Δt (3) where L is pile length, c is the longitudinal wave velocity, and Δt is the time interval to get the impact impulse peak velocity and reflection signal peak velocity. Because the impact impulse peak velocity occurs at different time as shown above, Eqs. (1) and (2) can be used to adjust the calculation results in Eq. (3). Because the accelerometer is impossible to be placed at the impact point, c calculated by Eq. (3) is greater than the actual velocity. It is especially important to test piles with short length and big radius. After the adjustment it is equal to the result obtained from the frequency domain. where f 0 is the frequency of the 1 st longitudinal vibration mode. c = 2Lf 0 (4) The accurate value of c can also be obtained by replacing Δt in Eq. (3) with the time difference of the 1 st and the 2 nd reflection signal from the pile end. However, even the 1 st reflection signal from the pile end cannot be detected in actual engineering field test, as the low energy of the light impact is not enough to travel a long distance,. Equations (1) and (2) are also useful to decide the depth of the defect along the pile. When the time difference is not considered in time domain, the depth of the defect is usually deeper than the calculated result. The difference depends on the radius of the pile and the distance between the points of impact and the accelerometer. When the defect exists, the reflection signal from the pile end is delayed compare to that from a good pile, see Fig. 6. This phenomenon can be explained by the longer distance which the stress wave passes through 5

the defect part. defect complete Fig 6 Comparison of computed velocity at 90º point of complete pile and defect pile(l= 6.0m) Conclusion This paper has studied the low strain integrity test of two types of piles. The influence of locations of the accelerometer on the signal and the signal interpretation are discussed. It was 2 found that the best location to place an accelerometer in the test is at the point of R away 3 from the source (center point) for solid piles or a point which forms a 90 angle with the source point for pipe piles. At these locations, the disturbing high frequency content is weakened. Equations were also developed to correct the longitudinal wave velocity calculation and the depth of defects. Further study should continue to improve the low strain pile integrity test, especially for long pile. As the energy of the light impact is very small that the produced stress wave cannot travel a long distance, the reflection signal can not be detected by a accelerometer when the pile is very long. The influence of surround soil on the test should also be considered for better results. References 1. Fan Chen, Renjun Wang, Dimension effect on low strain integrity testing of piles,.chinese Journal of Geotechnical Engineering, 1998, 20(5):92-96. 2. Wenzhang Luo, Velocity reaction of pipe piles under a load impulse M.S. thesis, 2002. 3. Fan Chen, Wenzhang Luo, Dimension effect on low strain integrity testing of prestressed pipe piles, Chinese Journal of Geotechnical Engineering, Vol. 26, No. 3, 2004. Biography of authors Mr. Wenzhang Luo is a graduate student of Department of Mechanical Engineering at 6

University of Bridgeport. He has a BS in Hydraulic Engineering from Tsinghua University and a MS in Civil Engineering from China Academy of Building Research. He has 8 years work experience in Civil Engineering field. Mr. Fan Chen is a professor of National Center for Quality Supervision and Test of Building Engineering, Beijing, China. He is the vice chairman of National Center for Quality Supervision and of Test of Building Engineering and the editor of Technical code for testing of building foundation piles. Dr. Hu is an assistant professor of Mechanical Engineering at University of Bridgeport. She received her Ph.D from the University of Missouri-Rolla in 2005. Dr. Hu s research area include computational fluid dynamics, heat transfer, welding, laser material processing, and thermal management of electronic devices and systems, micro-/nano- scale energy transport and finite element analysis of industrial applications. 7