Bruker Daltonics. microtof-q. Cutting Edge Performance with Sub-ppm Confidence. ESI-Qq TOF. think forward

Similar documents
microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Technical Note # TN-35 amazon Ion Trap: New Performance Levels Meeting Demanding Analytical Requirements

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

High-Field Orbitrap Creating new possibilities

Theory and Practical Consequences.

ABI 3200 Q TRAP LC/MS/MS System

Compounding insights Thermo Scientific Compound Discoverer Software

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

Thermo Finnigan LTQ. Specifications

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Agilent All Ions MS/MS

Finnigan LCQ Advantage MAX

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

The Power to See What You ve Never Been Able to See Before. Innovation with Integrity. Qq-FTMS

Powerful Scan Modes of QTRAP System Technology

Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Translational Biomarker Core

Guide to Peptide Quantitation. Agilent clinical research

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

MassHunter TOF/QTOF Users Meeting

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

MetWorks Metabolite Identification Software

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

4000 Q TRAP LC/MS/MS System. Advanced Linear Ion Trap technology at the highest level of sensitivity 4000 QTRAP. LC/MS/MS System

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Multi-residue analysis of pesticides by GC-HRMS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Making Sense of Differences in LCMS Data: Integrated Tools

Identifying Disinfection Byproducts in Treated Water

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Agilent ESI and APCI sources: for polar to non-polar compounds

TANDEM MASS SPECTROSCOPY

LC-MS Based Metabolomics

Application Note. Edgar Naegele. Abstract

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

Types of Analyzers: Quadrupole: mass filter -part1

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

QTOF-based proteomics and metabolomics for the agro-food chain.

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

MassHunter Software Overview

Die Nadel im Heuhaufen

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Extend Your Metabolomics Insight!

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

Analysis of Polar Metabolites using Mass Spectrometry

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Agilent Technologies LCMS Portfolio

UNIFI - Targeted and Untargeted Screening MS Software

[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

TOXICOLOGY & FORENSIC APPLICATIONS

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Workflow concept. Data goes through the workflow. A Node contains an operation An edge represents data flow The results are brought together in tables

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

MRMS axelerate rapidly detected micropollutants and plant response metabolites in poplar leaves

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Computational Methods for Mass Spectrometry Proteomics

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Matching UHPLC Resolution and Speed with Agilent Ultra High Definition Q-TOF Technology

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Reagents. Affinity Tag (Biotin) Acid Cleavage Site. Figure 1. Cleavable ICAT Reagent Structure.

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Transcription:

Bruker Daltonics microtof-q Cutting Edge Performance with Sub-ppm Confidence think forward ESI-Qq TOF

The advantage of ultimate confidence Do you need maximum confidence in your analytical system? Bruker Daltonics new microtof-q ESI-Qq-TOF mass spectrometer features the very lastest technology developments to provide maximum certainty in your research in Small Molecule Identification, Metabolomics or Proteomics. Mass accuracy several ppm accuracy plus Chemical expertise additional confidence plus SigmaFit (mass accuracy + TIP) sub-ppm confidence # possible formulae Simultaneously three dimensions of information promote your analytical tasks to unrivaled heights of confidence: Measure with unequalled accurate mass. Validate with True Isotopic Pattern (TIP) analysis. Benefit from accurate mass and TIP also in fragments analysis in MS/MS mode. Mass accuracy, chemical knowledge and SigmaFit clearly limit the number of possible formulae in molecular formula generation: for confident determination of the elemental makeup of a given peak. This precious sub-ppm confidence is available for formula determination in pharmaceutical impurity analysis, metabolite identification, pesticide screening and toxicology & doping analysis.

Unique Power 3 simultaneously without compromise It has never been this easy to use: Cutting-edge performance is now available in a comprehensive bench top package. sensitivity Experience market leading sensitivity with the next-generation Apollo II ion funnel ESI source, dramatically improving ion transmission. mass accuracy Be impressed by a mass accuracy of better than 3 ppm over an exceptionally wide dynamic range. resolution Be amazed from superb focus resolving power exceeding a resolution of 15,000 FWHM. fragment analysis Featuring a superb quadrupole mass filter and a quadrupole collision cell for accumulation of parent and fragment ions prior to mass analysis, the microtof-q expands the renowned microtof s advanced performance on the analysis of molecule fragments, adding a third level of confidence to the two dimensions of accurate mass and True Isotopic Pattern analysis with SigmaFit. A convenient, highly stable, external one-step calibration for automated data output with a mass accuracy of 3 ppm makes this instrument your easy-to-use companion with superior performance to all other (ESI)-TOF instruments. Achieve simultaneously reliable MS and MS/MS accuracy, independent of whether calibration was performed in MS or MS/MS mode. Thus, for chemical formula determination, a detailed formula suggestion is only three clicks away. Raise your research to higher power with all these skills available concurrently!

Unprecedented Certainty Isotopic Pattern Analysis MS analysis of Pd-Complex (C 61 H 65 N 4 O 15 ) in synthetic chemistry. Isotopic Pattern of measured spectrum and calculated spectrum (SigmaFit) show outstanding homogeneity, providing a superior sigma value for enhanced confidence in structural analysis. Precision in Organic Chemistry Accurate mass and Bruker Daltonics proprietary SigmaFit True Isotopic Pattern analysis algorithm provide unrivalled certainty for the identification of unknowns. Due to an extraordinarily wide dynamic range, the entire mass range is covered with a high mass accuracy resulting in unambiguous molecular formula generation. Mass accuracy is not enough: Using isotopic patterns for enhanced identification After generation of a list of possible formulae within 5 ppm mass accuracy, the measured isotopic pattern is compared with the theoretical isotopic pattern resulting in a stastistical match factor, SigmaFit. microtof-q s capability to deliver correct isotopic patterns discriminates over 200 possible formulae from 5 ppm mass accuracy alone to one single formula with a SigmaFit < 0.01. ISCID-MS/MS analysis of Pd-Complex in synthetic chemistry. A fragment m/z 157.0758 reveals a mass error of < 5 ppm for reading out a formula with a sigma value of < 0.006. Parent ion was m/z 1307, see above. The microtof-q covers the whole mass range with high mass accuracy. SigmaFit: Combining accurate mass with True Isotopic Pattern (TIP) capabilites of the micro- TOF-Q. Only one in over 200 possible formulae has a fit better than 0.01 Formula Generation from MS/MS Fragment SigmaFit Delivers the Correct Formula Measured Theory

Accurate mass, SigmaFit and MS/MS Metabolic Fragment ID and Statistical Analysis 317.0866 C 15 H 14 FN 4 SO + 15 302 C 14 H 11 FN 4 SO + 302.0638 Advancing Metabolomics Research Metabolic profiling promotes biomarker discovery to the metabolome level to address profiles that are powerful sensors reflecting situations at physiological endpoints. Identify small molecule biomarkers with the power of accurate mass, TIP and fragments analysis for evaluation of disease state, following drug treatment or to monitor toxic response. Tailored tools for pattern recognition, metabolite MS and MS/MS identification complete the solution package for metabolome research. Auto MS 2 of a Metabolite m/z 317 and the fragmentation of a methylgroup from the molecule increase confidence of identification by fragments analysis and allows to study the fragmentation pathway, e.g. amine- or methylgroup. Group 2 A clear separation of groups in the PCA analysis: Scores and Loadings Plot of rat urine samples From groups receiving different levels of food. (with friendly permission from Organon). 297 m/z @ 245s Group 1 194 m/z @ 335s Super-sensitive ion funnel source The new state of the art Apollo II ion funnel ESI electrospray source provides 10x more ions significantly improving sensitivity by an order of magnitude. This leads to substantial progress for applications such as detailed structural studies of low-abundance protein modifications, PTMs or natural products! All ions are collected by a radial RF field and smoothly directed towards the funnel exit. In the second funnel, CID energy can be freely selected for optimal performance of the experiment.

Information-Rich In Depth Analysis De novo Sequencing Down to Low Masses immonium ion proline i P-OH, C 4 H 8 NO (86.06004 m/z) i I/L, C 5 H 12 N (86.09643 m/z) The de novo Sequencing Machine The microtof-q is the ideal instrument to achieve outstanding mass accuracy including low masses, a prerequisite for successful de novo sequencing. Mass Distance RMS error: 0.97 mda Immonium Ions of proline (C 5 H 9 NO 2 ) in a MS/MS measurement of m/z 626.2862+: De novo sequencing down to low masses only the unique microtof-q can provide information on immonium ions in one spectrum. MS/MS spectrum of GluFib m/z = 785.8. Exceptional mass accuracy leads to outstanding de novo sequencing results. Powerful Identifications over a wide Dynamic Range High mass accuracy is available on both the peptides and fragments levels. Impressive mass accuracy on all peptides 1 meets unrivalled mass accuracy on fragments 2 a feature delivering the highest reliability for proteomics research. Mass Accuracy 1 2 Reproducible mass accuracy: 50 fmol BSA on a Waters UPLC column are measured with an RMS error of only 2ppm (1). Even fragments are reliably analyzed (2) with only 3 ppm RMS error (20 fmol BSA) from a single external calibration.

Proteomics Applications without Compromise Accurate Mass Measurements of PTMs Sulfation? Phosphorylation? Explore the Difference! Understanding proteomes requires knowledge about posttranslational modificati- ons. Detailed insights into the molecule s structure is achieved with the excellent mass accuracy of the microtof-q even with minor mass differences. Count on the Ability to Quantitate Stable isotopic labeling using itraq or the newly invented technology ICPL allow fast and convenient, yet easy-touse, quantitative proteomics research. Due to the ion funnel ESI source design, excellent sensitivity is achieved, coupled with highest confidence by true isotopic pattern (TIP ) analysis. High sensitivity, high mass accuracy and high resolution over the whole mass range is the instrument s contribution to an integrated solution for Quantitation from Bruker Daltonics: WARP-LC, a system providing automatic workflows from chromatography to quantitation. Distinction of sulfation and phosphorylation with microtof-q s accurate mass measurement capabilities. Regulatiom 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 IPLC-Quantitation 117/114 SILE Ratios Quantitation with WARP-LC Normalized Area 0.6 0.5 0.4 0.3 0.2 0.1 0.0 itraq_114 itraq_116 SILE Labels WARP-LC quantitation analysis: Box-and-whisker plot of an itraq labeled protein. For validation, the statistical distribution is shown. MS ICPL quantitation on the microtof-q in MS and MS/MS mode. MS/MS

Resolution and Sensitivity MS/MS ID from 500 amol BSA Sensitivity Ultimate sensitivity is demonstrated with a 500 amole digested BSA sample. Even for this low sample amount, solid peptide identifications are possible. Mass resolution Both small molecules and intact proteins are analyzed with excellent mass resolution. Isotopic resolution is achieved even for deconvoluted spectra. The simulated pattern fits perfectly to the measured mass spectrum. Analysis of 500 amol BSA digest on column. MS/MS of peptide 788.46 (1+), ion score 29 and the corresponding Mascot search result. Differentiation of isobaric dipeptides. C 7 H 13 N 2 O 5 (AD) MW physical = 205.0819 C 8 H 17 N 2 O 4 (SV) MW physical = 205.1183 delta MW = 0.0364 Da. For separation of the dipeptides at m/z 200, a resolution > 10,000 is achieved. Resolution of Isobaric Peptides Ribonuclease B. A spectrum of the intact protein acquired with the microtof-q. The mass difference to the calculated mass is only 1.3 ppm. A resolution of 20,000 FWHM is achieved. Intact Protein Mass Resolution measured spectrum, m = 1.3 ppm simulated spectrum; R=20,000 C 627 H 988 N 173 O 233 S 12,15052.74 204.75 205.25 205.75 206.25 206.75 m/z 15050 15055 15060 15065 15070 15075 15080 15085 m/z

Ultimate Performance with Superiour Detection Power Fragments Analysis ISCID Q-Separation CID Optional: ISCID + MS/MS Standard: MS/MS Fragments Analysis The microtof-q provides exceptional mass accuracy in MS/MS for metabolite and protein identification. Achieve optional additional fragmentation performance with a source designed for ion fragmentation prior to the quadrupole (In-Source CID). After isolation in the analytical quadrupole, the ISCID fragments can be further fragmented in the collision cell (CID). MS 3 with the microtof-q Reserpine: In-Source CID, Isolation of ISCID ions and fragmentation: MS 3.

Outstanding Solutions and Software Environment Target Screening Confident Quantitative and Qualitative Multi-Target Screening Forensics, Doping control, and Residue Analysis The TargetAnalysis application allows multi-target compound screening in complex matrices, providing high specificity and enhanced SigmaFit molecular formula determination. Multitarget Pesticide Screening: EIC of detected compounds with ± 0.002 Da mass window. Screen Hundreds of Compounds The solution is able to screen hundreds of compounds from a single sample LC/ESI-TOF run and enables screening for large compound libraries with a confidence level and reproducibility unsurpassed by any other system. This workflow saves significant time when running multi-target applications like drugs/metabolites in urine, food safety analysis, forensic toxicology or environmental testing. Create Own Libraries Users are enabled to create their own application-specific accurate mass libraries. The unique AMIC (accurate mass ion chromatogram) technique, with a tolerance down to +/- 0.002 Da, dramatically reduces chemical background interference and greatly improves specificity. Combine Multi Target screening with general unknown ID: Screen for multiple targets (up to several 100) Archive the whole sample-information ID unknowns with MS/MS ID of Unknowns Retrospective in silico screening for new or unexpected compounds is possible because unlike in triple-quad based MRM methods, the full molecular information content in addition to the target library specific information is retained.

Empowering accessories Metabolite ID User Interface Chemical Formula Generation Compass OpenAccess provides a automated walk-up LC/MS system for chemical formula generation, molecular formula confirmation and generic LC/MS measurements. This client-server based software supports LC/MS workflows especially for chemists in laboratories with various level of instrumental analysis experience. Metabolic Profiler Advance biomarker profiling to the metabolome level to address metabolomic profiles that are powerful sensors reflecting situations at physiological endpoints. An application feasable with the microtof-q in nutraceutical, pharmaceutical and clinical research. Metabolite ID Metabolite and small molecule prediction and detection is performed by MetaboliteTools, allowing detailed evaluation of samples and sample batches based on the sophisticated expose detection algorithm and accurate mass capabilities of microtof-q. MetaboliteTools predicts possible metabolites from a given drug structure, and extracts relevant information on existing metabolites for LC-MS data. ProteinScape Quantitation Result Proteomics Screening and in-depth Analysis Translate mass spectra into knowledge. ProteinScape with WARP-LC and BioTools provides unique software backbones to mass spectrometric proteome and protein analysis. Visualization tools for validation, such as the LC-SurveyViewer or quantification box-plots, are accompanied by protein identification tools, de novo sequencing support and PTM discovery. The Unified Software Environment Our unified Compass software environment for all our life science instruments integrates instrument control, data acquisition, processing and interpretation speeding research and enhancing productivity. Regulatory Compliance Compass Security Pack provides all necessary functions for work in compliance with FDA and EU regulations (21CFR part 11/Annex 11): electronic signatures audit trailing user management result history system protection during breaks

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL 05-2007, LS 23/2 Technical specifications Cutting-edge Performance Advanced microtof-q Technology World-leading combination of mass accuracy, resolution and sensitivity without compromise SigmaFit, the unique combination of accurate mass with True Isotopic Pattern (TIP ) Wide dynamic range for ultra-stable accurate mass High-performance Q-q-front end Footprint 640 x 949 x 1320 mm, weight 160 kg Source Options Apollo II ion funnel ESI Electrospray source (1 µl 1 ml/min) APCI atmospheric pressure chemical ionization source (100 µl 1,5 ml/min) APPI atmospheric pressure photo ionization source online / offline NanoElectrospray source CE/MS coupling with grounded ESI needle Analytical Performance Mass range 20 40,000 m/z Mass accuracy in MS and MS/MS 3 ppm RMS Error (internal), 5 ppm RMS Error (external) Mass resolution in MS and MS/MS 15,000 (FWHM) Temperature compensated Acquisition rate (2GHz sampling rate) 20 Hz (profile and peak detected spectra to disk) Compass Software Suite Integrated LC-MS/MS control and data processing Generate formula module using SigmaFit BioTools / RapiDeNovo software for protein data interpretation MetaboliteTools for metabolite identification ProteinScape database system for proteome project management The microtof-q seamlessly integrates in Bruker Daltonics System Solutions: TargetAnalysis for multi-target compound screening Compass OpenAccess : Walk-up LC/MS chemical formula generation Metabolic Profiler : The ideal tool for Metabolic Studies PROTEINEER : 2D Gel-MS/MS-based Proteomics Suite PROTEINEER-LC : LC-MS/MS-based Proteomics Suite microtof-q, SigmaFit, TIP, Apollo II, Compass, Compass OpenAccess, Compass Security Pack, Metabolic Profiler, MetabliteTools, expose, WARP-LC, BioTools, RapiDeNovo, PROTEINEER and PROTEINEER-LC are trademarks of Bruker Daltonics corporation. ICPL is a trademark of TopLab GmbH. itraq is a trademark of Applied Biosystems. ICAT is a trademark of the University of Washington. MASCOT is a registered trademark of Matrix Science Ltd. www.bdal.com Bruker Daltonik GmbH Bremen Germany Phone +49 (421) 2205-0 Fax +49 (421) 2205-103 sales@bdal.de Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) 663-3660 Fax +1 (978) 667-5993 ms-sales@bdal.com