SGE is excited to launch a new HPLC product line under the ProteCol brand.

Similar documents
Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

High Performance Liquid Chromatography

LC Technical Information

Introduction to Chromatography

CLIPEUS - A Small Shield for a Big Job

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Protein separation and characterization

Chromatography. Gas Chromatography

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Guide to Choosing and Using Polymer Reversed Phase Columns!

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Chapter content. Reference

Turn Imagination into Results. ProteCol HPLC Columns. Flexible hardware options High quality phases Perfect match for all your separation needs

HPLC Column Classification

LC and LC/MS Column Selection Flow Chart

Bringing uhplc Performance to the Separation of Peptides

Introduction to Chromatographic Separations

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah

Open Column Chromatography, GC, TLC, and HPLC

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Analytical Chemistry


COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Hypersil BDS Columns TG 01-05

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Packings for HPLC. Packings for HPLC

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

HPLC Column Material - Bulk Ware

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Shodex TM ODP2 HP series columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

SELECTING HPLC COLUMNS: GOING UNDER THE HOOD. HPLC Column Selection Guide

Biochemistry. Biochemical Techniques HPLC

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

What is Chromatography?

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Comparison Guide to C18 Reversed Phase HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns

HPLC Background Chem 250 F 2008 Page 1 of 24

penta-hilic UHPLC COLUMNS

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Gas Chromatography. Introduction

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Liquid Chromatography

Introduction to Chromatographic Separations (Chapter 1) Many determinations involve separation followed by analysis chromatography electrophoresis

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Advantages and Applications of Revolutionary Superficially Porous Particle Columns in Liquid Chromatography

Changing the way you think about HPLC


CHAPTER 6 GAS CHROMATOGRAPHY

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

High Pressure/Performance Liquid Chromatography (HPLC)

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents

Chromatographic Analysis

High Performance Liquid Chromatography

Introduction. Chapter 1. Learning Objectives

GC Instruments. GC Instruments - Sample Introduction

Epic Aromatic Selectivity

Introduction to Capillary GC

Gas Chromatography (GC)

ACE Ultra Inert Base Deactivated HPLC Columns

The Suite for Environmental GC Analysis

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C

Method Development Kits

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

InertSustainSwift C8

Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. CHAPTER 26

Chromatography and its applications

Optimisil HPLC & UPLC Column catalogue

Chromatography Outline

Chromatographic Separation

Principles of Gas- Chromatography (GC)

Introduction to Capillary GC

Transcription:

The Role of Pore Size in Reversed Phase HPLC SGE is excited to launch a new HPLC product line under the ProteCol brand. Fundamental to the new ProteCol line of columns is the continued focus on inert column design that was first created with the ProteCol PEEKsil offering (polymer - sheathed fused silica tubing). SGE is excited to offer a new range of ultra pure reversed phase silicas in both the unique GLT (glass lined tubing) column format as well as a new PEEK lined stainless steel format. The benefit is the most comprehensive inert HPLC reversed phase column offering from the 150 micron ID PEEKsil format through to the new 4.6 mm ID PEEK lined stainless steel columns. Why is Inert HPLC Column Design Important? Non-specific interactions between the target analyte and the silica particles in the HPLC column are now well controlled with the availability of ultrapure silicas. Today, most chromatographers expect that the silica sourced by manufacturers is of the highest purity and SGE confirms we have rigorously researched the quality of silicas using the standard reference material (SRM) provided Technology. Testing of silicas using SRM 870 (NIST) identifies non-specific interactions associated with metal contamination as well as non-end capped silanols (see Figure 1). What is often not considered is the role column hardware may play in non-specific interactions the frit and internal column hardware can both influence the behavior of analytes with known metal chelating activity. Most pharmaceutically active compounds and natural products have the potential to interact with metals. Coordination between the metal ion and the analyte is facilitated by a lone electron pair on the analyte molecule. If two electron donor groups (either oxygen or nitrogen) are located in a favorable position, a chelate can be formed and while the enthalpy of the complex formation for two monodentate ligands and a bidentate ligand is similar, the chelate is entropically favoured and leads to a stronger interaction. For this reason molecules like quinizarin, ProteCol -P C18 HQ105 Figure 1: Non-specific interactions of the NIST SRM870 probe molecules on commercially available C18 columns. (Comparison data available at: www.usp.org/uspnf/columns.html) 198 This selection guide can be viewed as an electronic book at sge.com/selectionguide

120000 100000 80000 Examples of potentially metal chelating compounds. 60000 40000 20000 PEEK lined Stainless steel Type I Silica 0 0 8 9 10 11 12 13 14 15 Figure 2: Chromatogram of tetracycline (antibiotic) and its major degradation product. Note the peak broadening on the base of the peak run through the stainless steel column leading to a 25% decrease in sensitivity. Inset: the tetracycline molecule depicting the three potential chelating groups. tetracycline or ciclopirox form tailing peaks in the presence of metal in the column/ system (see Figure 2). To address this potential risk, SGE s ProteCol column development has focused exclusively on the most inert C8 and C18 phases in a variety of pore and particle sizes in the most inert column hardwares glass lined, PEEK lined stainless steel (see Figure 3) and PEEKsil. Why Focus on Reversed Phase and Pore Size? Reversed phase chromatography is by far the most commonly used form of liquid chromatography and most chromatographers prefer to stay in the reversed phase environment rather than move into other less conventional buffer systems. Alkane modified silicas were developed in the 1970s and because of the better resolution and higher reproducibility, quickly became the most popular separation technique in liquid chromatography. Since the elution conditions and elution order are opposite to what was normal chromatography, the term reversed phase was coined and has remained the general term describing a hydrophobic bonded stationary phase. When it comes to considering the optimal reversed phase column for the separation of a target analyte, the majority of liquid chromatographers base their selection on the type of bonded phase (C18, C8, C4, Phenyl etc), whether the column is end capped and the overall carbon loading. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing C Porous PEEK frit D Stationary phase E Glass lining F Stainless steel column body B C A D E F A Column end cap B PEEK frit housing C Porous PEEK frit D Stationary phase E PEEK lining F Stainless steel column body Figure 3. SGE s inert column hardware includes glass and PEEK lined stainless steel. HPLC Columns 199

Don t Forget to Choose the Appropriate Pore Size of Your Reversed Phase Column! What is often ignored by chromatographers is the choice of optimal pore size of the silica for the appropriate application. In liquid chromatography virtually all interactions (and therefore retention) takes place inside the pore system. The exterior surface of common the total surface area. In order to use the available interactive surface, the analyte molecule needs unrestricted access to the particle interior. In most chromatographic applications pore diffusion is the time limiting step (the slowest step which therefore governs the overall kinetics). After overcoming the film mass transfer resistance, the solute has to diffuse into the pore system in order to bind to the surface since most of the surface is inside a porous as proteins, pore diffusion becomes a crucial factor. A number of models have been derived to describe the effect of the pore diameter on the diffusion constant of a solute molecule. These models range from the Fickian diffusion where the diffusion rate is purely concentration driven (large pores small solute molecules the mean free path of the Brownian motion is small compared to the pore diameter); to the Knudsen diffusion, where the mean path of the Brownian motion is equal or larger than the pore diameter (collisions with the wall play a major role in the determination of the diffusion rate). An extreme case is the single file diffusion, where the diameter of the solute solute molecule is larger than the radius of the pore. In this case molecules are unable to pass each other. In addition, an estimation for the steric hindrance at the pore entrance and the frictional resistance within the pore system was provided by Renkin. D p = D f 1 r s 2 1 2.104 r s + 2.09 r s 3 0.956 r s D f = Free molecular diffusion coefficient. D p = Diffusion as the coefficient inside the pore. r s, = Radii of the solute and the pore respectively. A graphical representation of the Renkin model and its implications are shown in Figure 4. 5 1000Å 500Da 1000Å 5kDa 300Å 500Da 200Å 500Da 1000Å 300Å 5kDa 120Å 500Da 100Å 500Da 200Å 5kDa 120Å 5kDa 300Å 100Å 5kDa 200Å 120Å 100Å Figure 4: Relative pore diffusion coefficients of large molecules in different pore size stationary phases 200 Copies of technical posters presented at scientific congresses can be downloaded at sge.com/support/documents

The drawback of large pore sizes in HPLC columns is the reduction in specific surface area. As the pore size increases, the accessible surface area for the solute to bind to decreases and with it the capacity of the column. Figure 5 shows the specific surface area of commercially available packing material versus the pore diameter. The choice of pore size for a given separation is a compromise between resolution on the high pore diameter end and load-ability (capacity) on the low pore diameter end. A rough guide for suitable pore diameter ranges (where the pore diffusion coefficient in free liquid) is shown in Figure 6. Figure 5. Reduction in column capacity due to increased pore size (blue dots represent published data by various column suppliers) 100Å 120Å 200Å 300Å 1000Å Figure 6: Acceptable molecular weight range of spherical & cylindrical shaped analytes in relation to pore size HPLC Columns 201

Figure 7: Schematic representation of the relative sizes of the five most abundant plasma proteins. As Figure 7 suggests, the use of 300 Å pore size stationary phases does have a practical limit for large molecules and you should be mindful of the sample s complexity before considering the separation of large macromolecules on this type of phase. Proteins are large macro molecules and diffuse slowly (small diffusion rate constant). Proteins are also more likely to cause a steric hindrance once they bind to the pore surface. In conclusion, SGE recommends the following guide to selecting the appropriate pore size based on your target analytes molecular weight range. Pore Size Spherical Analyte Cylindrical Analyte Lower Upper Lower Upper 100 30 800 13 350 120 50 1,400 23 610 200 240 6,400 100 2,800 300 800 21,400 350 9,500 1000 29,400 800,000 13,000 350,000 Pore Size (Å). Lower and Upper ranges shown in Daltons (Da) Expert Tips for Small Molecules Simple DO's and DON'Ts to protect your HPLC Columns: laboratory. through the HPLC system prior to shutdown. tubing and fittings before connection to the column. organic/aqueous solvent prior to using buffers. ferrules on one piece fingertights where possible. column. mended range for your column. system. zero flow for extended periods of time. buffers by preparing them days in advance. inside. phases. 202 This selection guide can be viewed as an electronic book at sge.com/selectionguide