DERMATOLOGICAL TEST REPORT SEMI-OCCLUSIVE PATCH TEST EXPANDED GROUP OF VOLUNTEERS

Similar documents
THE REPORT FROM DERMATOLOGICAL RESEARCH OF COSMETICAL PRODUCT WITH HALF OPEN PATCH TEST

THE REPORT FROM DERMATOLOGICAL RESEARCH OF COSMETICAL PRODUCT WITH HALF OPEN PATCH TEST

Food Additives and Fragrance Materials (Flammable) Group Standard HSR002576

Cleaning Products (Subsidiary Hazard) Group Standard HSR002530

Industrial and Institutional Cleaning Products (Toxic [6.1], Combustible) Group Standard HSR002594

ISCC Audit Procedure Classified chemicals

Reagent Kits Group Standard HSR002647

Embalming Products (Flammable, Toxic [6.1], Corrosive) Group Standard HSR002564

Gas Under Pressure Mixtures (Toxic [6.1]) Group Standard HSR002536

ENHANCEMENTS Lash Boost is only to be used as directed by one person. It is not to be shared with other people.

H&M Restricted Substance List Chemical Products Valid for all brands in H&M group. Restricted Substance List (RSL)

Fuel Additives (Flammable, Toxic [6.7]) Group Standard HSR002584

ESTA governance Quality Assurance System for Seed Treatment and Treated Seed

Pharmaceutical Active Ingredients Group Standard 2017 HSR100425

Leather and Textile Products (Subsidiary Hazard) Group Standard HSR002600

Polymers (Toxic [6.7]) Group Standard HSR002646

Water Treatment Chemicals (Toxic [6.1]) Group Standard HSR002685

Polymers (Toxic [6.1]) Group Standard HSR002645

Corrosion Inhibitors (Corrosive) Group Standard HSR002547

MATERIAL SAFETY DATA SHEET

Lubricants (Combustible, Toxic [6.7]) Group Standard HSR002608

HAZARD COMMUNICATION PROGRAM

Solvents (Flammable) Group Standard HSR002650

Fertilisers (Subsidiary Hazard) Group Standard HSR002571

HAZARD COMMUNICATION PROGRAM

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Control Standard for Handling Chemical Substances in Products, Parts and Materials

EUROPEAN COMMISSION. Brussels, XXX D046374/04 [ ](2016) XXX draft ANNEX 1 ANNEX

Class 4, Toxic [6.1] Substances Group Standard HSR002523

Globally Harmonized Systems A Brave New OSHA HazComm

Annex: Environmentally Hazardous Substance Management Standard

Fire Fighting Chemicals Group Standard HSR002573

METHOD 9079 SCREENING TEST METHOD FOR POLYCHLORINATED BIPHENYLS IN TRANSFORMER OIL

Lubricants (Low Hazard) Group Standard HSR002605

Laboratory Chemical Safety. Pathology Training

In 2012, the U.S. adopted the Globally Harmonized System for the Classification and Labelling of Chemicals, or GHS for short.

GHS Classification CONCEPT OF GHS

Guidelines for the Labelling of Chemical Products

DRAIN TRACING DYE RED E123

Tri-n-propyltin Chloride Mixture

Rosemary extract liquid

Hazard Communication for Dangerous and Harmful Materials

Additives, Process Chemicals and Raw Materials (Corrosive) Group Standard HSR002491

Biocidal Products Committee (BPC)

Hazardous Communication. Hazard Communication. Hazardous Communication. Hazardous Communication. Hazardous Communication. Hazardous Communication

GPS summary for Sodium Hypochlorite CAS: Brzeg Dolny

Reaction mass of dimethyl adipate and dimethyl glutarate and dimethyl succinate

Recognizing Chemical and Physical Changes

EUROPEAN COMMISSION HEALTH & CONSUMER PROTECTION DIRECTORATE-GENERAL. Directorate C - Public Health and Risk Assessment C7 - Risk assessment SCCP

Product Stewardship Summary

Materials Approach using the Toyograph CAS Number Approach

Globally Harmonized System of Classification and Labeling of Chemicals (GHS) LC-1033p Rev. 06/16

Regulation 6 months experience. Sonia Ribeiro 1-2 June 2010, London, UK

Hazard Communication. What You Need to Know. Southeastern OSHA Training Institute Education Center

HAZARD COMMUNICATION PROGRAM 2015 UPDATE GHS AWARENESS TRAINING CSULB COE

Basic Hazard Communication

Safety in the Chemistry Laboratory

Purpose. Sub-Committee of Experts on the Transport of Dangerous Goods. Forty-ninth session

Existing Systems of Product Labelling

Cree J Series 5630 LEDs

Chemicals in products - legislation

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

STORAGE, HANDLING & SAFE USE OF CHEMICALS AND HAZARDOUS MATERIALS

HACCP Concept. Overview of HACCP Principles. HACCP Principles. Preliminary Tasks Development of the HACCP Plan

Properties criteria - BETA

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

Letter to non European Union customers

Step-by-Step Guide to the REACH Regulations

7/8/2013. What is GHS?

ACULYN 46N Rheology Modifier/Stabilizer

Overview of HACCP Principles. OFFICE OF THE TEXAS STATE CHEMIST Texas Feed and Fertilizer Control Service Agriculture Analytical Service

Guide to Registration Requirements for Active Substance Manufacturers, Importers and Distributors in Ireland

Process Development & Scale-Up of the AIR Technology

Biocidal Products Committee (BPC)

Metolachlor ESA Sodium Salt Standard

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Biocidal Products Committee (BPC)

Biocidal Products Committee (BPC)

Material Safety Data Sheet acc. to ISO/DIS 11014

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE

POLYMER DISPERSIONS AND NANO-TECHNOLOGY

Food Safety Management System

2009/48/EC Chemical safety assessment

RADIATION SAFETY GUIDELINES FOR NON-USERS

Green Procurement Standards

7 Product-related Environmental Activities

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

INDUSTRY GUIDANCE. REACH for catalysts. 1. Introduction. 2. Fresh catalysts. 3. Active catalysts

Hazard Communication & Chemical Safety. Based on OSHA Standard

The information contained in this SOP is general in nature. Any YouTube videos included are as a compliment to the information presented.

The defence sector s criteria document chemical substances, chemical products and articles

Technical Data Sheet Tersil COR

Surface Coatings and Colourants (Flammable, Corrosive) Group Standard HSR002663

Call for expression of interest An invitation to present products suitable for use as a marker in gas oils and kerosene

HAZARD COMMUNICATION PROGRAM PREPARED BY ENVIRONMENTAL HEALTH AND SAFETY OFFICE

Biocidal Products Committee (BPC)

Technical Procedure for General Laboratory Equipment

VERSION 3.0 MARKS & SPENCER NOVEMBER 2015 ECP MINUMUM STANDARDS REACH. Registration, Evaluation and Authorisation of Chemicals

Today we re going to talk about understanding chemical labels. Each one of us works with chemicals, whether at work or at home. You need to know how

Product family data sheet

Transcription:

Client: KOŽELJ d.o.o. Dob Vegova ulica 12 1233 Dob Received on: 27.06.2017 Analysis completed on: 28.07.2017 Sample (according to declaration of the Client): RIBODERMIN MAZILO Ribodermin mazilo, 35 g Batch number: 186 Expiration date: 07.2019 Report date: 31.07.2017 DERMATOLOGICAL TEST REPORT SEMI-OCCLUSIVE PATCH TEST EXPANDED GROUP OF VOLUNTEERS Page 1 / 12

SCOPE OF TESTS COMPLIANT WITH: REPORT No. 253843/17/JSHS Regulation of the European Parliament and of the Council (EC) No. 1223/2009 of 30 November 2009 on cosmetic products. Cosmetics Europe The Personal Care Association (previously COLIPA) Guidelines Product Test Guidelines for the Assessment of Human Skin Compatibility 1997. Cosmetics Europe The Personal Care Association (previously COLIPA) Guidelines for the Evaluation of the Efficacy of Cosmetic Products 2008. Research Procedure applicable at the J.S. Hamilton Poland S.A. PB-242 - semi-occlusive patch test. Technical Instruction applicable at the J.S. Hamilton Poland S.A. IT-01/PK - Scope and organization of the tests in the Cosmetic Laboratory. Technical Instruction applicable at the J.S. Hamilton Poland S.A. IT-02/PK Dilution form of tested product used in semi-open patch test. Technical Instruction applicable at the J.S. Hamilton Poland S.A. IT-16/PK - Proceeding in positive skin reactions and side effects presence. Page 2 / 12

CONTENT OF THE REPORT: 1. The basis of the study. 2. Requirements for products called "hypoallergenic". 3. Object of study. 4. Qualitative composition of the product. 5. Declared intended use of the product. 6. Testing methodology. 7. Objective of the test. 8. Description of volunteers. 9. Date of performance of the study. 10. Evaluation parameters. 11. Results. 12. Calculated values. 13. Graphical representation of the results. 14. Interpretation. 15. Conclusion. 16. Signatures. Page 3 / 12

1. THE BASIS OF THE STUDY REPORT No. 253843/17/JSHS Test sample delivered by the Client. The qualitative composition of the product delivered by the Client. The result of microbiology purity performed in J.S. Hamilton (Report no. 253843/17/JSHS). The Client is responsible for compliance with the declared qualitative composition and microbiological purity of the product sample sent for testing. 2. REQUIREMENTS FOR PRODUCTS CALLED "HYPOALLERGENIC" Does not contain fragrance composition or the composition does not contain allergens in the INCI composition (verification IFRA certificate, list of allergens, MSDS). Does not contain Color Index in the INCI composition. ph similar to the natural ph of the skin. Does not contain irritating raw materials in the INCI composition. 3. OBJECT OF STUDY: No. Parameter Description 1. Appearance Ointment 2. Color Yellow 3. Fragrance Characteristic for used raw ingredients 4. Packaging Repackaging containing the name and the number of sample 4. QUALITATIVE COMPOSITION OF THE PRODUCT*: PETROLATUM, FISH LIVER OIL, LANOLIN, CERA ALBA, CETEARYL ALCOHOL, VANILLIN, RETINOL, CHOLECALCIFEROL 5. DECLARED INTENDED USE OF THE PRODUCT: The product is intended for use as an ointment. Page 4 / 12

6. OBJECTIVE OF THE TEST: REPORT No. 253843/17/JSHS The aim of the study was to assess the irritating properties (skin tolerance) of the product on a healthy adult skin, with applied patch test. 7. DESCRIPTION OF VOLUNTEERS: 50 volunteers at the age of 22 to 65 were selected for the test. The selection of the group included the criteria of inclusion and exclusion. In this group: 25 of the volunteers didn't report documented oversensitivity or a history of adverse reactions to individual ingredients of the tested product. The others 25 volunteers had dry, atopic, particular sensitive skin and reported documented oversensitivity or a history of adverse reactions to individual ingredients of the tested cosmetic or detergent product. All volunteers fulfilled the requirements of inclusion for tests and signed an informed consent form. Additionally they were advised of the purpose, methodology of the test and possible adverse effects. The skin at the application spot (arms or interscapular area) was healthy, without lesions. The participants were advised to use caution in handling the applied contact tests. 8. TESTING METHODOLOGY: Patch (skin) tests according to Jadassohn-Bloch as modified by Rudzki are performed under the supervision of a dermatologist. The semi-occlusive test is the basic kind of test confirming contact skin irritation. The assessment of sensitising and irritating properties of the product is performed on a group of 50% healthy volunteers with positive history of allergy/atopy. The preparation in the useful concentration is applied into a filter paper discs of 12 mm diameter, manufactured by SmartPractice and then fixed to the arm or interscapular area using sticking plaster. In a parallel time to objectify the results of studies two control samples: control sample name: "blind" and control sample with water are carried out. The purpose of this test is to exclude possible reading errors connected with the dermal irritation. The results of the studies are presented in section 10. The dermatologist removes the patch after 48h since the application and checks the skin response 30 minutes after removal. After 24h from last verification the dermatologist checks again for a skin response. If it is necessary, the skin response is observed also after 72 hours. Reading the response of the skin, the dermatologist assesses the irritating and sensitising effects of the tested product. The test results may be influenced by such factors as: the lifestyle, stress, diet and environmental conditions etc. Page 5 / 12

9. DATE OF PERFORMANCE OF THE STUDY: 17.07.2017 21.07.2017 24.07.2017 28.07.2017 Page 6 / 12

10. EVALUATION PARAMETERS: Table 1 REPORT No. 253843/17/JSHS EVALUATION PARAMETERS OF SKIN REACTION Erythema Classification point No erythema 0 Light erythema 0,5 Erythema and/or papules Erythema and/or papules and/or vesicles Erythema and/or papules and/or vesicles and/or blisters Erythema Bullous and/or ulcerative reaction and/or papules and/or vesicles and/or blisters Edema 1 2 3 4 Classification point No edema 0 Very light edema (hardy visible) 1 Light edema 2 Moderate edema (about 1mm raised skin) 3 Strong edema (extended swelling even beyond the application area) 4 Page 7 / 12

11. RESULTS: Table 2 Results for 25 volunteers with a negative history of allergy. No. Characteristics of the volunteers History of allergy Application spot Test result 48 hours after application Test result 72 hours after application Test result 96 hours after application Age Sex Erythema Edema Erythema Edema Erythema Edema 1 65 F negative Arm 0 0 0 0 0 0 2 36 F negative Arm 0 0 0 0 0 0 3 31 F negative Arm 0 0 0 0 0 0 4 29 F negative Arm 0 0 0 0 0 0 5 26 F negative Arm 0 0 0 0 0 0 6 27 F negative Arm 0 0 0 0 0 0 7 25 F negative Arm 0 0 0 0 0 0 8 23 F negative Arm 0 0 0 0 0 0 9 28 F negative Arm 0 0 0 0 0 0 10 33 F negative Arm 0 0 0 0 0 0 11 45 F negative Arm 0 0 0 0 0 0 12 49 F negative Arm 0 0 0 0 0 0 13 30 F negative Arm 0 0 0 0 0 0 14 59 F negative Arm 0 0 0 0 0 0 15 27 F negative Arm 0 0 0 0 0 0 16 25 F negative Arm 0 0 0 0 0 0 17 25 F negative Arm 0 0 0 0 0 0 18 24 F negative Arm 0 0 0 0 0 0 19 30 F negative Arm 0 0 0 0 0 0 20 48 F negative Arm 0 0 0 0 0 0 21 25 M negative Arm 0 0 0 0 0 0 22 59 F negative Arm 0 0 0 0 0 0 23 23 F negative Arm 0 0 0 0 0 0 24 31 M negative Arm 0 0 0 0 0 0 25 40 F negative Arm 0 0 0 0 0 0 Page 8 / 12

Table 3 Results for 25 volunteers with a positive history of allergy. No. Characteristics of the volunteers History of allergy Application spot Test result 48 hours after application Test result 72 hours after application Test result 96 hours after application Age Sex Erythema Edema Erythema Edema Erythema Edema 1 37 F positive Arm 0 0 0 0 0 0 2 24 M positive Arm 0 0 0 0 0 0 3 26 F positive Arm 0 0 0 0 0 0 4 22 F positive Arm 0 0 0 0 0 0 5 59 F positive Arm 0 0 0 0 0 0 6 26 F positive Arm 0 0 0 0 0 0 7 60 F positive Arm 0 0 0 0 0 0 8 24 F positive Arm 0 0 0 0 0 0 9 26 F positive Arm 0 0 0 0 0 0 10 25 F positive Arm 0 0 0 0 0 0 11 47 F positive Arm 0 0 0 0 0 0 12 25 F positive Arm 0 0 0 0 0 0 13 30 F positive Arm 0 0 0 0 0 0 14 39 F positive Arm 0 0 0 0 0 0 15 45 F positive Arm 0 0 0 0 0 0 16 26 F positive Arm 0 0 0 0 0 0 17 27 M positive Arm 0 0 0 0 0 0 18 26 F positive Arm 0 0 0 0 0 0 19 27 F positive Arm 0 0 0 0 0 0 20 27 F positive Arm 0 0 0 0 0 0 21 32 F positive Arm 0 0 0 0 0 0 22 29 F positive Arm 0 0 0 0 0 0 23 42 F positive Arm 0 0 0 0 0 0 24 27 F positive Arm 0 0 0 0 0 0 25 30 F positive Arm 0 0 0 0 0 0 Page 9 / 12

12. CALCULATED VALUES: REPORT No. 253843/17/JSHS The following calculated values present the sum of erythema and edema defined as Average Irritation Index (xav). Table 4 Result 48 hours after product application Result 72 hours after product application Result 96 hours after product application Erythema 0,00 0,00 0,00 Edema 0,00 0,00 0,00 Xav 0,00 13. GRAPHICAL REPRESENTATION OF THE RESULTS: 1,000 0,900 0,800 0,700 0,600 0,500 0,400 0,300 0,200 0,100 0,000 erythema after 48h edema after 48h erythema after 72h edema after 72h erythema after 96h edema after 96h Xav Page 10 / 12

14. INTERPRETATION: The average irritation index (xav) of the 50 tests was calculated. The product was then classified according to the following table no 5: Table 5 Average irritation index (xav) xav < 0,5 Class Not irritating 0,5 xav < 2,0 Slightly irritating 2,0 xav < 5,0 Moderately irritating 5,0 xav Highly irritating 15. CONCLUSION: The patch test study was performed under dermatological control on a group of 50 volunteers, including 25 volunteers with positive history of allergy/atopy (sensitive skin). The study allows to conclude, that product RIBODERMIN MAZILO used by persons, for whom allergy to any of its ingredients hasn t been documented, is good tolerated by the skin. In the tested group of volunteers there were no irritations or allergic reactions. The product meets the requirements for products called hypoallergenic and requirements of compatibility test with atopic and sensitive skin (Skin Compatibility Test) and can be classified as NOT IRRITATING. Page 11 / 12

16. SIGNATURES: Authorized by: Dermatologist Dorota Karpowicz 9055994 Authorized by: Cosmetic Laboratory Manager Marta Rosińska Prepared by: Project Manager Assistant Helena Barańska *The Client is responsible for conformity with the declared quality composition as well as microbiological cleanliness of the delivered samples. Attention: Released opinion of dermatological safety does not apply people who are allergic to any ingredient of the tested product. Page 12 / 12