Inductive behavior of electrolytes in AC conductance measurements

Similar documents
Frequency Dependence of Conductivity Characteristics of Seawater Ionic Solution under Magnetic Field

CET Q UESTIONS QUESTIONS

PH213 Chapter 24 Solutions

Elizabethtown College Department of Physics and Engineering PHY104

Demystifying Transmission Lines: What are They? Why are They Useful?

Light, Electricity and Liquids. By Vitaliy Zamsha and Vladimir Shevtsov

PHY3128 / PHYM203 (Electronics / Instrumentation) Transmission Lines

Characteristic of Capacitors

Capacitors. Charging a Capacitor. Charge and Capacitance. L05: Capacitors and Inductors

CET Q UESTIONS QUESTIONS

Downloaded from

MAGNETIC FIELDS & UNIFORM PLANE WAVES

CONDUCTOMETRIC TITRATIONS. Reading: 1. Skoog, Holler and Nieman: Chapter 22 A. INTRODUCTION. A.1 Classification of Electroanalytical Methods

Bridge Measurement 2.1 INTRODUCTION Advantages of Bridge Circuit

Conductivity dependence of the polarization impedance spectra of platinum black electrodes in contact with aqueous NaCl electrolyte solutions

Core Technology Group Application Note 3 AN-3

metrologia A. Jeffery, R. E. Elmquist, J. Q. Shields, L. H. Lee, M. E. Cage, S. H. Shields and R. F. Dziuba

Metallized Polypropylene Film Capacitor Related Document: IEC

Fouling of reverse osmosis membranes using electrical impedance spectroscopy: Measurements and simulations

INCREASING INFORMATIVITY OF THE THERMALLY STIMULATED DEPOLARIZATION METHOD

University Physics (PHY 2326)

Electrical Circuits Lab Series RC Circuit Phasor Diagram

A Fixed Surface Potential Probe with the Swing Capacitive Electrometer Compared to the Vibrating Kelvin Probe

ENGR 2405 Chapter 6. Capacitors And Inductors

Non-Faradaic Impedance Characterization of an

Evaluation of Capacitance in Motor Circuit Analysis Findings. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

HIGH ENERGY DENSITY CAPACITOR CHARACTERIZATION

Large, light-induced capacitance enhancement in semiconductor junctions simulated by capacitor-resistor nets

RADIO AMATEUR EXAM GENERAL CLASS

Ab initio study of CNT NO 2 gas sensor

Optimization of MnO2 Electrodeposits using Graphenated Carbon Nanotube Electrodes for Supercapacitors

CHEMISTRY Matter and Change

Effect of parasitic capacitances on impedance measurements in microsensors structures: a numerical study

THE EFFECT OF REVERSAL ON CAPACITOR LIFE

Electrochemical impedance spectroscopy study of the nucleation and growth of apatite on chemically treated pure titanium

Contactless Impedance Sensors and Their Application to Flow Measurements

(name) Electrochemical Energy Systems, Spring 2014, M. Z. Bazant. Final Exam

Do not fill out the information below until instructed to do so! Name: Signature: Section Number:

Metallized Polypropylene Film Capacitor Related Document: IEC

NR/RR. Set No. 2 CODE NO: NR/RR210204

Requirements to perform accurate dielectric material analysis

A Simulation Model of Fluid Flow and Streamlines Induced by Non-Uniform Electric Field

Ballistic transport at GHz frequencies in ungated HEMT structures

EIS of Organic Coatings and Paints

ASSOCIATE DEGREE IN ENGINEERING TECHNOLOGY RESIT EXAMINATIONS SEMESTER 2 JUNE 2011

MCE603: Interfacing and Control of Mechatronic Systems. Chapter 1: Impedance Analysis for Electromechanical Interfacing

Material parameters for electrostriction

Electronic Supplementary Information

4.1.1 (conductance) (conductivity)

Molar Mass to Moles Conversion. A mole is an amount of substance. The term can be used for any substance and 23

Electrical Properties of Moist Limestone Samples 7. In The Frequency Range 1Hz-10 Hz From Abu Rawash Area

Student Achievement. Chemistry 12

An Optimised High Current Impulse Source

Electrophoretic Deposition. - process in which particles, suspended in a liquid medium, migrate in an electric field and deposit on an electrode

Lec.1 Chemistry Of Water

A fast method for the measurement of long spin lattice relaxation times by single scan inversion recovery experiment

Capacitor. Capacitor (Cont d)

The Basic Elements and Phasors

NABTEB Past Questions and Answers - Uploaded online

The Proposed Electric Circuit Diagram Of The Buried Bare Pipe Segment- Soil - Earth System With And Without Applying Cathodic Protection System

Annexure-I. network acts as a buffer in matching the impedance of the plasma reactor to that of the RF

Homework 4 Part One Due 14 October at 6:00 pm

Class 6. Capacitance and Capacitors. Physics 106. Winter Press CTRL-L to view as a slide show. Class 6. Physics 106.

COURSE OUTLINE. Introduction Signals and Noise Filtering Sensors: Piezoelectric Force Sensors. Sensors, Signals and Noise 1

LOW FREQUENCY NOISE OF TANTALUM CAPACITORS*

Stabilization and destabilization effects of the electric field on stochastic precipitate pattern formation

Application of the Electrical Impedance Spectroscopy in the Electrochemical Cell Constant Determination

Electricity

Electromagnetism Question 1 What influences the strength of an electromagnet? What property does a needle inside a compass possess?

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Supplementary material for High responsivity mid-infrared graphene detectors with antenna-enhanced photo-carrier generation and collection

Aqueous Reactions and Solution Stoichiometry (continuation)

Circuit elements in carbon nanotube-polymer composites

CIRCUIT ELEMENT: CAPACITOR

Chapter 24 Capacitance and Dielectrics

Trade of Electrician Standards Based Apprenticeship Capacitance Phase 2 Module No. 2.1 Unit No COURSE NOTES

Piezoelectric Resonators ME 2082

Development of Tetrapolar Conductivity Cell for Liquid Measurement Application

7.Piezoelectric, Accelerometer and Laser Sensors

Energy stored in a capacitor W = \ q V. i q1. Energy density in electric field i. Equivalent capacitance of capacitors in series

EDEXCEL NATIONALS UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES. ASSIGNMENT No.2 - CAPACITOR NETWORK

Generalized four-point characterization method for resistive and capacitive contacts

Physics (

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

2005 AP PHYSICS C: ELECTRICITY AND MAGNETISM FREE-RESPONSE QUESTIONS

ELECTROMANETIC PULSE PROPAGATION IN A COAXIAL CABLE

1000 to pf (E3 series) Dielectric material K2000 K5000 K14000 Rated DC voltage 100 V 100 V 63 V Tolerance on capacitance ±10% 20/+50% 20/+80%

LCR Series Circuits. AC Theory. Introduction to LCR Series Circuits. Module. What you'll learn in Module 9. Module 9 Introduction

Chemical Equilibrium

TECHNICAL NOTE. ε0 : Dielectric constant in vacuum (= F/m) ALUMINUM ELECTROLYTIC CAPACITORS. 1 General Description of Aluminum Electrolytic

Chapter 13. Capacitors

SURFACE MOUNT MONOLITHIC CHIP CAPACITORS COG AND TEMPERATURE COMPENSATING TYPES GRM36/39/40/42-6/42-2/43-2/44-1 Series

Acids and Bases. Click a hyperlink or folder tab to view the corresponding slides. Exit

Electrical Conduction. Electrical conduction is the flow of electric charge produced by the movement of electrons in a conductor. I = Q/t.

Outline. ECE 477 Digital Systems Senior Design Project. Module 7 Capacitor Selection Guidelines. Film Ceramic Electrolytic Miscellaneous

Module 3 Electrical Fundamentals

Experiment FT1: Measurement of Dielectric Constant

JOURNAL OF APPLIED PHYSICS 102,

Explosion Properties of Highly Concentrated Ozone Gas. 1 Iwatani International Corporation, Katsube, Moriyama, Shiga , Japan

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Transcription:

Chemical Physics Letters 402 (2005) 274 278 www.elsevier.com/locate/cplett Inductive behavior of electrolytes in AC conductance measurements Adela Bardos a,b, Richard N. Zare a, *, Karin Markides b a Department of Chemistry, Stanford University, Stanford, CA 94305-5080, USA b Department of Analytical Chemistry, School of Chemistry, Uppsala University, Uppsala, Sweden Received 17 October 2004; in final form 9 December 2004 Abstract The alternating current conductance of various electrolytes contained inside a capillary is measured as a function of frequency from 1 khz to 10 MHz. The response is found to be characteristic of the concentration and composition of the electrolyte. A simple model is able to reproduce well the dispersive shape of the frequency-dependent conductance. Ó 2004 Elsevier B.V. All rights reserved. * Corresponding author. Fax: +1 650 723 9262. E-mail address: zare@stanford.edu (R.N. Zare). Despite the importance of electrolytes in different applications, their response to an alternating current (AC) at variable frequency has not yet been systematically studied. Already in the 1950s, models of electrodeless arrangements were reported [1] based on a condenser-type cell approach. The models did not consider inductance and did not reflect the nature of the electrolyte. More recent theoretical modeling and numerical simulations reveal a rather complex dispersive character of such liquids, particularly at high concentrations [2 4]. A realistic model of the frequency dependence of the ionic conductivity of an electrolyte solution must consider the contributions to the conductivity both from ion atmosphere relaxation and from electrophoretic effects. The frequency-dependent conductivity is intimately related to the frequency-dependent electrolyte friction [2]. Approximations must be made in theoretical models, especially regarding the molecular details of the ion solvent and solvent solvent correlations. For that reason, these theories are limited to solutions having a concentration 0.1 M or less [2]. In this Letter, we report on AC measurements and interpretation of the dispersive character of electrolytes. It is shown that dispersion curves are characteristic of electrolyte composition and concentration. We are able to model the dispersive behavior by incorporating the effect of the frequency-dependent impedance of the electrolyte on the output signal. We have built a simple experimental system for measuring the conductivity inside a fused silica capillary with inner diameter 75 lm using two external 5 mm wide Cu foil electrodes capacitively coupled to the electrolyte. This arrangement avoids direct contact with the electrolyte. Similar systems with non-invasive electrodes capacitively coupled to the electrolyte have already been tested by other workers [5,6] for conductivity measurements. The AC output signal from the measured liquid in such circuits depends sensitively on the actual construction and geometry of the electrodes as well as on the amplifying and measuring electronic circuits. Our objective was to optimize our measurement circuit to achieve a strong effect of the electrolyte on the measured output signal. The circuit was designed to obtain the highest possible frequency stability of both the input and the output AC signals, in order to use the experimental circuit to investigate the frequency dependence of the impedance of several electrolytes. Fig. 1 presents a schematic drawing of the AC circuit. The Cu electrodes were tightly wound around the capillary to insure good coupling to the electrolyte. The spacing between the electrodes was chosen to be 1 cm (which 0009-2614/$ - see front matter Ó 2004 Elsevier B.V. All rights reserved. doi:10.1016/j.cplett.2004.12.047

A. Bardos et al. / Chemical Physics Letters 402 (2005) 274 278 275 Fig. 1. (a) Schematic diagram of the measurement circuit. Z liq represents the impedance of the liquid. The capacitance C of each Cu electrode was estimated to less than 0.5 pf. V 0 = 15 V (peakto-peak), R = 55.2 kx. (b) Cross-section of conductivity detector viewed from above. is considerably larger than in previous work [5,6]) to achieve the largest possible effect of the electrolyte on the output signal at a negligible risk of coupling capacity between the electrodes, while still having a large enough output signal. The capacitance C of each Cu electrode was estimated to less than 0.5 pf by considering each electrode as a coaxial capacitor, where the electrolyte is the inner conductor and the capillary wall (coated by polyamide) together with a possible air gap between the capillary and the Cu foil form the dielectric, taking into account the different relative permittivities of the materials comprising the dielectric. The voltage source used guaranteed stable input voltage at all frequencies over which the output voltage signal was measured across a 55.2 kx metal film resistor, the value of which is stable in the frequency range considered here. Finally, the signal was measured by an oscilloscope with an input impedance of 1 MX. Assuming a pure resistive behavior of the electrolyte, the imaginary part of the impedance in the circuit is given only by capacitors (identical at both sides) formed between the electrodes and the electrolyte. In this case, the frequency curves should reach saturation values dependent on the conductivity of the electrolyte. Our experimental results revealed, however, a much more complex dispersive character of the ionic liquids. Fig. 2 compares typical results of the frequency variation of the output AC voltage for solutions of ammonium acetate, urea, ammonia, NaCl, and pure water. Examination of Fig. 2 shows large variations in circuit output for different electrolytes, both in signal strength and dispersion shape. Clearly, NaCl is a better conductor (a strong electrolyte) as opposed to for example a 7 M urea water solution. The fact that water has an almost flat profile and air has basically no signal shows that the dispersive character reflects the electrolyte impedance and does not result from the circuit itself. The effect of concentration on the electrolyte impedance is obvious in Fig. 3, where the output signals increase with increasing concentrations of urea (Fig. 3a) and NaCl (Fig. 3b). An interesting effect of the electrolyte composition is shown in Fig. 4, featuring the time evolution of a 7 M urea water solution. Concentrated aqueous solutions of urea are sensitive to higher temperatures, which makes such solutions decompose (hydrolyze) to yield free ammonia (the rate of decomposition increases with concentration) even at room temperature. In Fig. 4, a 7 M urea solution maintained at room 2 1 1 Water 0.30% NH3 water solution 5mM ammonium acetate buffer ph 4.3 2M NaCl water solution 7M urea water solution 0 20 40 60 80 100 120 140 Fig. 2. Output voltage signal of the experimental system as a function of generator input frequency for several electrolytes. The dispersion varies greatly.

276 A. Bardos et al. / Chemical Physics Letters 402 (2005) 274 278 (a) (b) 3.00 4M urea 2.50 7M urea 2.00 1.50 1.00 0.50 0 10 20 30 40 50 60 3 2M NaCl 2 5M NaCl 2 1 1 0 2000 4000 6000 8000 10000 Fig. 3. Output voltage signal of the experimental system as a function of generator input frequency for: (a) two different concentrations of urea in water; (b) two different concentrations of NaCl in water. The output signal increases with concentration. 8.00 7.00 6.00 4.00 3.00 2.00 Day 1 Day 2 Day 3 Day 5 Day 7 Day 10 1.00 0 50 100 150 200 250 Fig. 4. Output voltage signal of the experimental system as a function of generator input frequency for a series of urea solutions in consecutive stages of decomposition. As the decomposition progresses with time, the ion composition of the electrolyte and its characteristic dispersion profile changes. temperature was measured over the course of several days. The results show how the change in ion composition of the solution shifts the dispersion peak to the right (toward the dispersion peak of ammonia) and also increases the output signal (caused by a stronger ionic strength of the hydrolyzed solution).

A. Bardos et al. / Chemical Physics Letters 402 (2005) 274 278 277 To explain the experimental results, we have considered the possible contribution of an inductive component L liq to the impedance of the electrolyte. Assuming a complex impedance Z liq (x) of the electrolyte Z liq ðxþ ¼R liq þ jxl liq ; ð1þ where R liq is the resistance of the electrolyte, the output voltage signal v(x) measured in our AC circuit can be expressed as vðxþ ¼RiðxÞ ¼RV 0 =ZðxÞ; ð2aþ ZðxÞ ¼2Z C þ Z liq ðxþþz R with Z liq ðxþ ¼R liq þ jxl liq and ð2bþ ð2cþ jvðxþj ¼ RjiðxÞj h i ¼ RV 0 xc= ð2 x 2 2 1=2; CL liq Þ2 þ xcðr liq þ RÞ ð2dþ where V 0 is the constant input AC voltage signal (V 0 = 15 V peak-to-peak in most experiments) with variable frequency up to 50 MHz. Fig. 5 compares the calculated and experimental curves for urine, an ammonium acetate buffer solution (5 mm, ph 4.3) and a 7 M urea water solution. The resistance R liq of an electrolyte was estimated to be around 75 MX from center of one electrode to the center of the other electrode using current readings in high voltage capillary electrochromatography (CEC) separations with ammonium acetate (5 mm, ph 4.3) as a running buffer. This value was adjusted for individual electrolytes to fit the experimental dispersion curves (31.5 MX for urine, 93 MX for ammonium acetate and 275 MX for urea). In our theoretical dispersion model, increasing the resistance R liq decreases the output voltage but does not affect the overall shape of the dispersion. Increasing the inductance L liq, however, changes the shape of the curve and shifts the peak frequency to lower values. Comparing these characteristics to what is shown in Figs. 2 4, we conclude that increasing the concentration of an electrolyte can be associated mainly with a decrease of R liq and a slight decrease of L liq. A change of electrolyte ion composition leads to both a change in R liq and a change in L liq. For the decomposing urea water solution in Fig. 4, the hydrolysis is reflected by a decrease of R liq as well as by a decrease of L liq. For pure water, the theoretical dispersion model predicts an inductance of less than 1 H; for a dispersion curve like the one of NaCl, the value of L liq must be below 10 H. The higher the inductance, the narrower the dispersion peak; values of L liq above 1 kh yield increasingly spike-shaped dispersion curves not seen in the liquids tested experimentally. We have also examined the possibility of an even more complex impedance of the electrolyte by considering it to have a small parallel capacitance. We concluded, however, that the effect of the parallel capacitance was negligible. Excellent fits of the experimental dispersion profiles with the theoretical response of our AC circuit confirm that the AC impedance of electrolytes can be approximated by a resistive component R liq and an inductive component L liq, as expressed in Eq. (2). The resistance R liq can be considered in first approximation to be independent of frequency. It obviously depends on the ionic strength, that is, the extent of ionization (strong vs. weak electrolytes), as well as on the concentration and the type of ions. The interpretation of the inductance L liq in electrolytes is more complex. As inductance is generally defined in terms of an electromagnetic force generated to oppose 25 20 15 10 Theoretical fit 7M Urea in water 5 m M Am m onium acetate Urine 5 0 0 200 400 600 800 1000 Fig. 5. The fit of the theoretical model of the circuit impedance and the resulting output voltage signal according to Eq. (2) to the experimental dispersion measurements for urine, 5 mm ph 4.3 ammonium acetate buffer solution and 7 M urea water solution.

278 A. Bardos et al. / Chemical Physics Letters 402 (2005) 274 278 a given change in current, we believe that in electrolytes such a force can be generated by frictions resulting from the ion atmosphere relaxation effect and the electrophoretic effect [7]. We believe that the fact that the value of L liq decreases slightly with increasing concentration is associated with the ion atmosphere relaxation effect. Increasing concentration may lead to a form of shielding of the effect from the relaxation friction, arising from an ion atmosphere of a closer range, which in turn means a smaller deformation and hence a lower friction. The inductance of electrolytes is a new approach to the AC characterization of the conductivity. Test experiments with different electrolytes and a sensitive response of the circuit to changes in electrolyte, for example from hydrolysis, together with a perfect agreement of the experimental dispersion profiles with the theoretical fit confirm that the inductance value might serve as an important parameter, for example, in comparison of age and quality of electrolytes. Acknowledgments The authors gratefully acknowledge Oliver Trapp, Ignacio Zuleta, Gabriele Trapp, Joel Kimmel, Evan Pearce, and Oh Kyu Yoon for stimulating discussions and useful assistance. References [1] P. Delahay, C.N. Reilley, New Instrumental Methods in Electrochemistry, Interscience Publishers, New York, 1954. [2] A. Chandra, B. Bagchi, J. Chem. Phys. 112 (4) (2000) 1876. [3] J.E. Anderson, J. Non-Cryst. Solids 172 174 (1994) 1190. [4] A. Samanta, S.K. Ghosh, J. Mol. Liq. 77 (1998) 165. [5] A.J. Zemann, E. Schnell, D. Volgger, G.K. Bonn, Anal. Chem. 70 (1998) 563. [6] J.A. Fracassi da Silva, C.L. do Lago, Anal. Chem. 70 (1998) 4339. [7] P.W. Atkins, Physical Chemistry, fifth edn., Oxford University Press, New York, 1994 (Chapter 24.5).