Demonstration of a TEQ Selective PCB Immunoassay

Similar documents
Polychlorinated biphenyls (PCBs)

Aroclors, Homologs and Congeners An Evaluation of the Options for PCB Analysis and a Comparison of the Interpretive Value

SUPELCO. The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns. Katherine K. Stenerson and Leonard M.

Development and Use of Screening Methods for Rapid Characterization. Barry Lesnik, USEPA and Sara Hartwell, SAIC

Jennifer Bowman Dr. Natalie Kruse Dr. Glen Jackson Dr. Dina Lopez Mengliang Zhang

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

PCBs IN FRESHWATER AND MARINE SEDIMENTS: TRANSPORT, TRANSFORMATION AND TREATMENT. Organized by. D.A. Dzombak and G.V. Lowry

PCB Chemistry 101. Presented by Valerie Tillinghast O Reilly, Talbot & Okun Associates, Inc.

LEVELS IN SOIL AND WATER. Richard Wenning 1, Andrea Von Burg 1, Linda Martello 1, John Pekala 1, Martha Maier 2, William Luksemburg 2.

PosterReprint INTRODUCTION

Data Glossary. Acceptance criteria - specific limits placed on characteristics of an item, process, or service defined in requirements documents.

ONE STEP CLOSER TO A COOK BOOK METHOD FOR DIOXIN ANALYSIS PART 2: ANALYSIS OF FOOD SAMPLES

Annex IX: Risks for PolyChlorinated Biphenyls (PCBs)

Generating the Right PCB Data: Determination of Aroclors Versus PCB Congeners 8075

Chemical Characterization of Polychlorinated Biphenyls, -Dibenzo-p-Dioxins, and -Dibenzofurans in Technical Kanechlor PCB Formulations in Japan

Worldwide Recognition for the Synthesis of All 209 PCB Congeners

PCB Alternative Analysis Comparison of Aroclor to low and high-resolution GCMS. Laura Inouye (Ecology)

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

2015 Delaware Estuary Science & Environmental Summit Jim Occhialini, Cindy McQueen Alpha Analytical

Analyzing PCBs in Source Materials and Environmental Media: Soil, Water and Air. Jim Occhhialini Jim Okun Patricia McIsaac

IDENTIFICATION OF BROMINATED FLAME RETARDANTS IN FABRICS FROM INTERNATIONAL SOURCES

Dioxins & PCBs concerns

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

Anthropogenic chemicals & nanomaterials: Persistent Concerns in Oceans and Human Health.

PCBs and the Great Lakes

METHOD 4040 SOIL SCREENING FOR TOXAPHENE BY IMMUNOASSAY

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

MR. TELLIARD: Our next speaker is Brian. MR. FOWLER: First of all, I would like. to thank Bill and the EPA for the conference, and I think it

Remedial Investigation of Sediments in NJDEP s Site Remediation and Waste Management Program

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis

Determination of BSAFs for freshwater fish and derivation of a sediment standard for PCBs: a case study of the Rhone basin

APPENDIX G. Data Management Rules. Dioxin Data Report Appendix G. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area

Table S1. Summary of target PCB congeners. Numbers are BZ numbers (Ballschmiter and Zell, 1980) listed in order of elution from an HT8-PCB column.

Marine Mammal Tox: Overview (1 st class) February 5, Marine Mammals. # aquatic (marine or freshwater) species

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

p,p -DDE in Bluefin Tuna, Swordfish,

DEVELOPMENT OF A SAMPLE PREPARATION SYSTEM FOR DIOXINS: APPLICATION TO IMMUNOASSAY

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

How Overly Cautious Risk Assessment Methods Overstate Risk from PCBs in Indoor Air

L 364/32 Official Journal of the European Union

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Polychlorinated Biphenyls (PCBs): Environmental Chemistry

Official Journal of the European Union REGULATIONS

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

METHOD 9079 SCREENING TEST METHOD FOR POLYCHLORINATED BIPHENYLS IN TRANSFORMER OIL

Loading capacity and chromatographic behavior of a porous graphitic carbon column for polychlorinated biphenyls

Measurements of Household Dust Concentrations of PCDDs, PCDFs, and PCBs from a Community in Michigan, USA. Lynn Zwica, MS

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

VALIDATION OF AN IMPROVED EUROPEAN STANDARD METHOD FOR THE DETERMINATION OF PCBs IN OIL SAMPLES

Monensin ELISA Kit. Catalog Number KA assays Version: 11. Intended for research use only.

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Ecotoxicology Biology Acute and Chronic Lethal Effects to Individuals: Contaminant Interactions and Mixtures

Perspectives on the Confirmation of 2,3,7,8-TCDF for Isotope-Dilution HRGC/HRMS Methodologies

Introduction. Polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), naphthalenes (PCNs), and biphenyls (PCBs) are

PCBs Lower Chlorinated ELISA Kit

Immunoassay Screening Method for Polychlorinated Biphenyls (PCBs) in Insulating Oil (PCB sensor)

GC Analysis of Polybrominated Flame Retardants Application

Abstract. Key Words: leachability, PCBs, DOM, TOC, k d, ortho-pcbs, FTIR

(Non-legislative acts) REGULATIONS

Putting the Pieces of the Puzzle Together. By Kim Kirkland, Methods Team Leader EPA s Office of Resource Conservation and Recovery

SECTION 3 PRODUCT COMPOSITION The test kit is composed of QuSTICK Strep A Reagent Stick, Reagent A, Reagent B, Positive Control, and Negative Control.

Assess the Potential for Accumulation of Toxic Trace Elements in Biota near Burton Island Ash Disposal Site Indian River Bay, Delaware

Forebay Confirmatory Sediment Sampling Results

Dr. Jonathan Gutow Fall Looking for PCBs in Water or Can PCBs Wash out of Landfills and Contaminate Ground Water?

Separation of Toxic Coplanar PCB Congeners from Other Congeners in Marine Sediments and Marine Fish Tissues Using Florisil and GC ECD

Surveillance of dioxins and polychlorinated biphenyls (PCBs) in food commercialized in Barcelona, Spain

The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners

The Role of Proficiency Tests in the Estimation of Measurement Uncertainty of PCDD/PCDF and PCB Determination by Isotope Dilution Methods

SEDIMENT QUALITY OF THE NY/NJ HARBOR SYSTEM

KESTREL. April 26, Mr. Stephen Evans Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578

ANALYTICAL REPORT. Attn: Richard Boelter

Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application

Learning centre Management Chemicals Issues of Importance for Sustainable Development. CSD-19 May 3, Beijing, April 2010

The toxicity of three PCB congeners having different

Polychlorinated biphenyls

ANALYTICAL REPORT. Attn: Richard Boelter

by PSP Volume 15 No Fresenius Environmental Bulletin

IgG (Rabbit) ELISA Kit

ANALYTICAL REPORT. Attn: Richard Boelter

Fast and Accurate Analysis of PBDEs in a Single Run, Including

ANALYTICAL REPORT. Attn: Richard Boelter

The following revisions are being implemented for the PCDD/F Supplemental QAPP:

ANALYTICAL REPORT. Attn: Richard Boelter

Grouping and Read-Across for Respiratory Sensitisation. Dr Steve Enoch School of Pharmacy and Biomolecular Sciences Liverpool John Moores University

NANOTECHNOLOGY SOLID WASTE IMPLICATIONS. Gurumurthy Ramachandran. University of Minnesota

European Chemicals Agency (ECHA)Topical Scientific Workshop: Regulatory Challenges in Risk Assessment of Nanomaterials

1.0 INTRODUCTION AND BACKGROUND

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

BACKGROUND What are PBDEs? Regulatory Status of PBDEs in Canada

Use the three tables of spectral data on the Data Sheet where appropriate.

PAHs in Parking Lot Sealcoats. Performance Study. Asphalt Based. Coal Tar Sealcoat Sealcoat. Sealcoat. Scrapings. Asphalt Based.


IgG (Bovine) ELISA Kit

ONTARIO TOXICS REDUCTION ACT

Transcription:

Demonstration of a TEQ Selective PCB Immunoassay Robert E. Carlson and Robert O. Harrison* ECOCHEM Research, Inc., MD 23, 1107 Hazeltine Blvd., Chaska MN 55318 * CAPE Technologies, L.L.C., 3 Adams St., South Portland ME 04106 Manuscript submitted for presentation at Dioxin 99 (19th International Symposium on Halogenated Environmental Organic Pollutants and POPs) September 12-17, 1999 Venice, Italy Published in Organohalogen Compounds (1999) 40:47-51 CAPE Technologies Technical Reference TR-003 8/31/00 page 1

Demonstration of a TEQ Selective PCB Immunoassay Robert E. Carlson 1 and Robert O. Harrison 2 1 ECOCHEM Research, Inc., MD23, 1107 Hazeltine Blvd., Chaska, Minnesota, USA 55318 2 CAPE Technologies LLC, 3 Adams St., South Portland, Maine, USA 04106 INTRODUCTION PolyChlorinated Biphenyls (PCBs) are industrial products which were prepared as mixtures of the mono- to decachlorinated isomers (congeners) of biphenyl (1). PCBs are ubiquitous environmental contaminants (2). Of the 209 possible PCB congeners, only 14 have been assigned Toxicity Equivalence Factor (TEF) values on the basis of their dioxin equivalent toxicology (3). These 14, which are currently believed to be the most environmentally significant, are used in the calculation of a sample's Toxicity Equivalence (TEQ; 3). These congeners occur in much smaller amounts than the dominant, less toxic congeners in industrial PCB formulations and environmental samples (1,2). As a result of the growing recognition that congener specific PCB analysis is required for an objective evaluation of risk and environmental impact (3,4), we initially developed an Enzyme ImmunoAssay (EIA) which was specific for the most toxic, coplanar PCB congeners (5): PCB #77, 3,3,4,4 - tetrachlorobiphenyl; PCB #126, 3,3,4,4,5-pentachlorobiphenyl; PCB #169, 3,3,4,4,5,5 - hexachlorobiphenyl (3). This assay was used in the development of procedures for the analysis of these selected congeners in complex PCB mixtures (6). Unfortunately, although this assay gave a result which is nominally correct on a congener concentration basis, it severely overestimates sample TEQ because the relative immunoassay cross-reactivity of PCB #77 versus PCB #126 (0.63 versus 1.00) does not parallel the relative TEF values of 0.0001 versus 0.1 for these two congeners (3,5). This presentation describes the development of a TEQ selective PCB immunoassay. MATERIALS AND METHODS The development of an appropriate antibody and assay competitor combination for this TEQ specific immunoassay was similar to our previous study (5) and will be described in detail elsewhere (6). Manufacture of these components into a coated tube EIA followed our usual method (7). Performance of the assay also followed our usual protocol (8). RESULTS AND DISCUSSION The primary design goals of a TEQ specific PCB immunoassay can be derived from PCB toxic congener occurrence in the environment. Two broad types of samples were considered: samples which have been directly contaminated with PCB containing wastes (e.g. hazardous waste site soils) and samples which have been indirectly contaminated with PCB s through food chain exposure (e.g. evaluation of the biotic environment and human food supplies). Congener specific data for several Aroclor samples (Aroclor 1242, 1254, 1260, data not shown (9)) and a limited set of biota samples (n = 7; copepod, clam, fish, bird, mammal, data not shown (10-13)) was used to determine the per cent TEQ contribution of the 14 PCB toxic congeners. The Aroclor data established that PCB # 118, 126, 156 and 170 are substantial contributors to TEQ with each congeners relative importance dependent on the particular Aroclor formulation (data not shown). The biota data indicated that the toxic congeners could be ranked based on mean percent occurrence (Table I) with PCB #126 accounting for nearly half CAPE Technologies Technical Reference TR-003 8/31/00 page 2

of the observed TEQ. These data established that PCB #126 is the primary analyte for TEQ determination. The Aroclor and biota data could also be used to establish a sensitivity target for the assay. The biota data gave a TEQ concentration range of 10.0-104 pg TEQ per ug of total Aroclor (10-13). The Aroclor samples gave a TEQ concentration range of 3.7-19.8 pg TEQ per ug of total Aroclor (9). These samples also contained 3.0-27.1 pg PCB#126 per ug of Aroclor (Aroclor samples) and 52.8-667 pg PCB#126 per ug of Aroclor (biota samples). Based on these data and a typical sample size of 1-10 grams, the immunoassay must be sensitive to PCB#126 in the 10-100 pg per assay range to provide for both reasonable sample size and PCB#126 / TEQ sensitivity. PCB#126 sensitivity was evaluated in the EIA using multiple standard curves and both within day and between day timeframes. Combination of these results (n = 8) gave a minimum detection limit (mdl, operationally defined as 15% assay inhibition) of 5.2 pg (1.3 pg std dev), an assay midpoint (I50) of 50.6 pg (6.5 pg std dev) and an assay working range of 5-1,000 pg. These results demonstrate that this EIA is sufficiently sensitive for TEQ determination. A TEQ specific assay must also be proportionately sensitive to the other PCB congeners which contribute to TEQ and insensitive to the non-teq congeners. Table I lists assay cross reaction for the 14 PCB congeners which are used in the determination of TEQ. This table demonstrates that there is reasonable correspondence between the TEF values assigned for these congeners and assay crossreactivity, especially PCB #118 and 156 s equivalence to PCB #126 and the 100 fold difference in cross-reactivity between PCB #77 and PCB #126. A more important test of the assay is based on the observation that the range of TEQ is typically 10-100 pg TEQ per ug of total sample Aroclor. Thus the non-teq or common congeners are present in 1,000 to 100,000 fold excess over the TEQ congeners. This observation indicates that the assay must be insensitive to the non-teq congeners. One approach to the evaluation of non-teq congener sensitivity is to measure the cross-reactivity of all 195 non-teq congeners. Clearly, this would require a major effort. Our approach was to develop a Model Aroclor 1254 which contains appropriate ratios of the major component non-teq congeners. This Model Aroclor 1254 was defined by combining congener specific data for 3 different lots of Aroclor 1254 (1,9,14) and calculating the mean occurrence of the approximately 80 congeners which are observed in these samples (data not shown). Further evaluation of this data established that the 24 congeners which are present at greater than 0.5 weight per cent concentration accounted for 68% of the total mass of these Aroclor 1254 samples. These 24 congeners where chosen as the Model Aroclor 1254 (TEQ free) sample set. Table I lists the cross-reactivity of the assay to these congeners. These data establish that the assay is relatively insensitive to these common congeners. More importantly, comparison of the calculated Model Aroclor 1254 assay response to the observed TEQ of a characterized Aroclor 1254 (Table II) indicates that the calculated assay response of 1.37 pg TEQ per ug Aroclor is small compared to the observed Aroclor 1254 TEQ of 19.8 pg TEQ per ug Aroclor. Thus the assay appears to be sufficiently selective to define the 10-100 pg TEQ per ug Aroclor levels which are expected to occur in the presence of the substantial excess of the Aroclor 1254 common congeners. This calculated result was confirmed experimentally. The Model Aroclor 1254 was prepared using the indicated weight per cent values (Table I) of the 24 non-teq congeners. Immunoassay of the Model Aroclor 1254 gave results (calculated 1.37 pg TEQ per ug Aroclor, observed 1.17 pg [0.32 std. dev.] TEQ per ug Aroclor; Table II) which are in excellent agreement with the calculated response. The next step in the process of establishing assay performance was to evaluate Model Aroclor 1254 samples which had been spiked with various concentrations of PCB#126. These data, which were obtained by preparing PCB #126 standard curves in the presence of ug quantities of the Model Aroclor 1254, demonstrated that the assay could detect PCB #126 without substantial loss of sensitivity (PCB #126 I50 without Model Aroclor -> 56.6 pg versus I50 with 1-10 ug Model Aroclor - CAPE Technologies Technical Reference TR-003 8/31/00 page 3

> 58.8-78.8 pg). The final step in the development of this prototype was to evaluate the performance of the assay in the analysis of the characterized Aroclor 1254. The results in Table II [HRGC/HRMS calculated 19.8 pg TEQ per ug Aroclor, immunoassay calculated 14.6 pg TEQ per ug Aroclor, immunoassay observed 15.5 pg TEQ per ug Aroclor] clearly demonstrate excellent agreement between the calculated and observed immunoassay results and the HRGC/HRMS derived TEQ value. In conclusion, we have successfully developed a prototype TEQ specific immunoassay. This demonstration is the first step in the process of assay validation using a broad range of real samples for the correlation of HRGC/HRMS versus immunoassay results. ACKNOWLEDGEMENTS Our thanks to Brock Chittim at Wellington Laboratories for providing characterized Aroclor 1254 samples and data. REFERENCES 1) Schulz D.E., Petrick G., Duinker, J.C., Environmental Science and Technology 1989, 23: 852-859. 2) Duinker J.C., Schulz D.E., Petrick G., Analytical Chemistry 1988, 60, 478-482. 3) a) Ahlborg U.G. et al, Chemosphere 1994, 28: 1049-1067. b) WHO European Centre Environment and Health, Organohalogen Compounds 1997, 34: 237. 4) Jones K.C. Science of the Total Environment 1988, 28: 1049-1067. 5) Chiu Y.W., Carlson R.E., Marcus K.L., Karu A.E. Anal. Chem. 1995, 67: 3829-3839. 6) R.E. Carlson, in preparation. 7) Harrison R.O. and Carlson R.E., Organohalogen Compounds 1997, 31: 139-144. 8) DF1 Immunoassay Protocol at www.cape-tech.com 9) Brock Chittim, Wellington Laboratories, Guelph, Ontario, CANADA; personal communication. 10) Kannan N., Reusch T., Schulz-Bull D., Petrick G., Duinker J., Environmental Science and Technology 1995, 29: 1851-1859. 11) Focardi S., Bargagli R., Corsolini S., Antarctic Science 1995, 7: 31-35. 12) Elskus A., Stegeman J., Gooch J., Black D., Pruell R. Environmental Science and Technology 1994, 28: 401-407. 13) Colombo J., Brochu C., Bilos C., Landoni P., Moore S. Environmental Science and Technology 1997, 31: 3551-3557. 14) Frame G., Cochran J., Bowadt S. Journal of High Resolution Chromatography 1996, 19: 657-668. CAPE Technologies Technical Reference TR-003 8/31/00 page 4

TABLE I. Cross-reaction and Related Data. Biota percent TEQ values not shown are less than 0.1%. Weight percent refers to the composition of the Model Aroclor 1254. PCB Toxic Congeners Cross- Biota PCB No. Substitution TEF Reactivity TEQ % Non-Ortho 77 3,4 / 3,4 0.0001 0.0090 0.3 81 3,4,5 / 4 0.0001 0.0054 126 3,4,5 / 3,4 0.1 * 1.00 * 43 169 3,4,5 / 3,4,5 0.01 2.32 3.6 Mono-Ortho 105 2,3,4 / 3,4 0.0001 0.00017 5.1 114 2,3,4,5 / 4 0.0001 0.000063 118 2,4,5 / 3,4 0.0005 0.000064 18 123 3,4,5 / 2,4 0.0001 0.0011 156 2,3,4,5 / 3,4 0.0001 0.0043 21 157 2,3,4 / 3,4,5 0.0005 0.011 167 2,4,5 / 3,4,5 0.00001 0.0093 189 2,3,4,5 / 3,4,5 0.0001 0.092 Di-Ortho 170 2,3,4,5 / 3,4,5 0.0001 0.000083 7.5 180 2,3,4,5 / 2,4,5 0.00001 0.000023 1.8 Aroclor 1254 Common Congeners Cross- Weight PCB No. Substitution Reactivity Percent Tetrachloro- 44 2,3 / 2,5 <0.000002 3.25 49 2,4 / 2,5 <0.000002 2.00 52 2,5 / 2,5 <0.000002 8.00 66 2,4 / 3,4 0.000058 1.50 70 2,5 / 3,4 0.00013 5.00 Pentachloro- 82 2,3,4 / 2,3 0.000009 1.00 84 2,3,6 / 2,3 <0.000002 2.00 85 2,3,4 / 2,4 0.000005 1.50 87 2,3,4 / 2,5 0.000009 6.00 92 2,3,5 / 2,5 0.000005 1.50 95 2,3,6 / 2,5 0.000005 9.50 97 2,4,5 / 2,3 0.000005 2.50 99 2,4,5 / 2,4 <0.000002 4.75 101 2,4,5 / 2,5 <0.000002 13.00 110 2,3,6 / 3,4 0.000005 12.00 Hexachloro- 128 2,3,4 / 2,3,4 0.000035 2.50 132 2,3,4 / 2,3,6 0.000005 2.00 138 2,3,4 / 2,4,5 <0.000002 8.25 141 2,3,4,5 / 2,5 0.000005 1.00 149 2,3,6 / 2,4,5 0.000018 5.00 153 2,4,5 / 2,4,5 0.000023 5.00 158 2,3,4,6 / 3,4 0.000005 1.25 163 2,3,5,6 / 3,4 0.000021 0.50 168 2,4,6 / 3,4,5 0.000028 1.00 CAPE Technologies Technical Reference TR-003 8/31/00 page 5

Table II. Aroclor Immunoassay Results. Data compares calculated versus observed TEQ and PCB 126 equivalents results. Model Aroclor 1254 Calculated 1.37 pg TEQ per uq Model Aroclor 1254 Immunoassay 13.7 pg PCB 126 Equivalents per ug Model Aroclor 1254 Observed 1.17 pg [n=3, 0.32 std dev] per ug Model Aroclor 1254 Immunoassay 11.7 pg [n=3, 3.2 std dev] PCB 126 Equivalents per ug Model Aroclor 1254 Wellington Aroclor 1254 Calculated TEQ 19.8 pg TEQ per ug Aroclor 1254 HRGC/HRMS 198 pg PCB 126 Equivalents per ug Aroclor 1254 Calculated 14.6 pg TEQ per ug Aroclor 1254 Immunoassay 146 pg PCB 126 Equivalents per ug Aroclor 1254 Observed 15.5 pg [n=3, 0.86 std dev] per ug Aroclor 1254 Immunoassay 155 pg [n=3, 8.6 std dev] PCB 126 Equivalents per ug Aroclor 1254 CAPE Technologies Technical Reference TR-003 8/31/00 page 6