Why the fuss about measurements and precision?

Similar documents
In this lab you are asked to make a series of volume and temperature measurements and record the number of significant figures in each measurement.

Measurements, Sig Figs and Graphing

Chemistry Lab: Introduction to Measurement

Accuracy and Precision of Laboratory Glassware: Determining the Density of Water

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value

CHM 130 Measurements, Significant Figures, Derived Quantities, and Unit Conversions

Numbers in Science Exploring Measurements, Significant Digits, and Dimensional Analysis

7.5 MULTIPLYING DECIMALS

Experiment 1 - Mass, Volume and Graphing

Topic 11: Measurement and Data Processing and Analysis. Topic Uncertainties and Errors in Measurement and Results

CHM Accuracy, Precision, and Significant Figures (r14) C. Taylor 1/10

Density of Brass: Accuracy and Precision

Significant Digits What digits are important when recording a measurement?

Chemistry 11. Unit 2: Introduction to Chemistry. Measurement tools Graphing Scientific notation Unit conversions Density Significant figures

What s in a Scientist s Toolbox?

Figure 1. A portion of a metric ruler (the centimeter scale has been enlarged for ease in reading).

The periodic table currently lists 116 different atoms. New atoms are being discovered.

Making Measurements. Units of Length

MEASUREMENT IN THE LABORATORY

EXPERIMENT 1 Chemistry 110 LABORATORY SAFETY

Lesson 5: Significant Digits. AKA Significant Figures

precision accuracy both neither

CHM101 Lab Measurements and Conversions Grading Rubric

Measurements in the Laboratory

03.1 Experimental Error

experiment3 Introduction to Data Analysis

Measurements and Data Analysis

Measurement and Density

Chemistry 143 Dr. Caddell Laboratory Experiment 1

1.5 Reporting Values from Measurements. Accuracy and Precision. 20 Chapter 1 An Introduction to Chemistry

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 03: EXPERIMENTAL ERROR

Numbers and Uncertainty

Appendix A: Significant Figures and Error Analysis

Measurements UNITS FOR MEASUREMENTS

The measurements you make in the science laboratory, whether for time,

Introduction and Review

Significant Figures. Significant Figures 18/02/2015. A significant figure is a measured or meaningful digit.

HW #1: 1.42, 1.52, 1.54, 1.64, 1.66, 1.70, 1.76, 1.78, 1.80, 1.82, 1.84, 1.86, 1.92, 1.94, 1.98, 1.106, 1.110, 1.116

Uncertainty in numbers

Honors Chemistry 2016 Summer Assignment

INTRODUCTORY CHEMISTRY Concepts and Critical Thinking Seventh Edition by Charles H. Corwin

MEASUREMENT: PART II

Metric Measurement Lab. Hypothesis This laboratory activity does not require the production of a hypothesis.

Introduction and Review

Measurements and Calculations. Chapter 2

Chem 321 Lecture 4 - Experimental Errors and Statistics 9/5/13

Chapter 3 Scientific Measurement

I. INTRODUCTION AND LABORATORY SAFETY

Meas ure ment: Uncertainty and Error in Lab Measurements

Density of Aqueous Sodium Chloride Solutions

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

Using Scientific Measurements

Significant Figures: A Brief Tutorial

Making Measurements. On a piece of scrap paper, write down an appropriate reading for the length of the blue rectangle shown below: (then continue )

Source: Chapter 5: Errors in Chemical Analyses

1 Measurement Uncertainties

Density of Aqueous Sodium Chloride Solutions

MEASUREMENTS AND ERRORS

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 03: EXPERIMENTAL ERROR

PART I: MEASURING MASS

Pre-lab: Read section 9.9 (pages ) on acid-base titrations in the textbook. Complete the attached pre-lab by Tuesday, June 2.

Chemistry 11. Measuring and Recording Scientific Data. Measurement tools Graphing Scientific notation Unit conversions Density Significant figures

see page 8 of these notes )

Pre-lab: Read sections 10.6 in the textbook. Complete the attached pre-lab by Thursday, May 22.

Introduction to Measurement

Appendix C: Accuracy, Precision, and Uncertainty

Section 3 Using Scientific Measurements. Look at the specifications for electronic balances. How do the instruments vary in precision?

Significant Digits and Measurement

Chapter 3 Scientific Measurement

Uncertainty, Error, and Precision in Quantitative Measurements an Introduction 4.4 cm Experimental error

11.1 Uncertainty and error in measurement (1 Hour) 11.2 Uncertainties in calculated results (0.5 Hour) 11.3 Graphical techniques (0.

CHM 130LL: The Metric System

To become acquainted with simple laboratory measurements and calculations using common laboratory equipment.

Experiment 1. Determination of the Density of Water and an Unknown Solid Sample

A Volumetric Analysis Lab Report Answers

Chemistry Calibration of a Pipet and Acid Titration

Scientific Method. Why Study Chemistry? Why Study Chemistry? Chemistry has many applications to our everyday world. 1. Materials. Areas of Chemistry

Work Session 2: Introduction to Measurements, Conversions, and Significant Figures

Chesapeake Campus Chemistry 111 Laboratory

Measurement: The Basics

1 Measurement Uncertainties

INTRODUCTION TO MEASUREMENTS

Station 1: The Celsius Thermometer

Do Now: Use the ruler below to answer the following questions

Uncertainty in Measurements

6. Common Laboratory Techniques

Take the measurement of a person's height as an example. Assuming that her height has been determined to be 5' 8", how accurate is our result?

Work Session # 1: Measurements and Significant Figures

CHAPTER 2: SCIENTIFIC MEASUREMENTS

ISP 207L Supplementary Information

Experimental Uncertainty (Error) and Data Analysis

Accuracy of Measurement: how close your measured value is to the actual measurement

Appendix B: Accuracy, Precision and Uncertainty

CHAPTER TWO: MEASUREMENTS AND PROBLEM SOLVING

Introduction to Measurement Physics 114 Eyres

IB Physics (HL) Student Guide for Measurement Error and Uncertainty Analysis. Ballston Spa High School

Significant Figures And The Density Of Water - Version 1.5

Mixing ratios of gases can also be expressed in ppvb, parts per billion (10 9 ) by volume.

PHYS Uncertainty Analysis

Practice Lab. Balances and calibration of volumetric tools

Transcription:

Introduction In this tutorial you will learn the definitions, rules and techniques needed to record measurements in the laboratory to the proper precision (significant figures). You should also develop a clear idea of how random errors determine the precision of a measurement and be able to work with these errors on an absolute and relative basis. The objectives of this tutorial include To learn about types of errors associated with a measurement. To learn how to determine or estimate the precision (uncertainty) of a measurement. To work with relative and absolute errors confidently. Why the fuss about measurements and precision? When a quantity is measured in the laboratory, that measurement comes with some uncertainty. This uncertainty reflects the precision of the measurement. Depending upon the instrument the uncertainty may be large relative to the measurement, like trying to measure the width of a hair using a mm scale! More often the uncertainty is small relative to the measurement, like one finds when measuring mass on an analytical balance. Regardless of the instrument the experimenter must be able to recognize the limitations of the measuring device and report all measurements to the correct precision. Measurements are a central part of the science of chemistry and physics. Any chemistry or physics textbook contains a large number of scientific facts and several scientific theories. The facts were obtained and the theories are supported by carefully made measurements. In order for experimental results to be meaningful, the experimenter must: 1. Record the results of his or her measurements carefully. 2. Repeat the measurement to increase its reliability. Since individual results from a series of repeated measurements will seldom be the same, a best value is obtained by taking the average, or mean, x. 3. Establish the probable limits of precision that can be placed on the measurement. When a measurement is made, one of the goals is to achieve an accurate and as precise a measurement as possible based on the instrument in use. The terms precision and accuracy are often used in discussing measured values. Precision is an indication of how much uncertainty can be expected in a given measurement or the average of several measurements. Accuracy refers to how closely a measurement agrees with the correct, or true, value. The analogy of darts stuck in a dartboard illustrates the difference between these two concepts. In lab we can always discuss the precision of a measurement, but we cannot discuss accuracy unless the true value is known. In lab, the true value is often unknown! Daley 1 9-Oct-09

Background Errors associated with making measurements can be divided into two types: systematic and random. A systematic error causes a measurement to always be too low or too high. Systematic errors arise from a faulty instrument, a defect in the procedure or a consistent mistake in using the instrument. One example is an improperly calibrated balance. All systematic errors affect the accuracy of a measurement but not the precision. This tutorial will not discuss systematic errors and their prevention in any detail, but will focus on random errors, those errors that limit the precision of an instrument and determine the significant figures for a measurement. Random errors result in individual measurements that are just as likely to be too high as too low. Random errors depend on the precision of the instrument and the skill of the person making the measurement. Random errors cannot be avoided, since there is always some degree of uncertainty in every measurement. Smaller random errors result in a higher degree of precision. As a final note, although high precision is often an indication of good accuracy, this need not always be true. It is possible to have low accuracy due to a systematic error, but still have high precision. Precision (uncertainty) of a measurement Each instrument (e.g., ruler, beaker, thermometer, balance, etc.) you use in the laboratory has a precision that determines the uncertainty (or error) in any measurement taken with that instrument. The precision of an instrument is usually expressed in terms of a ± value. In general, in a scientific measurement, the last digit recorded is taken to be inexact (it is estimated) and is called the error digit. Recording a measurement with the correct number of significant figures is necessary in order to reflect the inherent precision of the instrument. Unless stated otherwise, the precision in a recorded measurement is taken to be ± one unit in the error digit. For example, a reported value of 95.4 ml indicates to the reader a precision of ± 0.1 ml (95.4 ± 0.1 ml). If the precision in the measurement is not ± one unit in the error digit, then the experimenter has a responsibility to report the actual precision. If the precision is ± 0.5 ml the recorder should report 95.4 ± 0.5 ml. A ± error, by definition, should only have one significant figure. If we are uncertain about a volume in the first decimal place, we can know nothing about the uncertainty in the second, third, or any other decimal place! Types of instruments digital or analog. The instruments you will use in lab can be divided into two types: those that have a digital scale and those that have an analog scale. Lets first discuss measurements and absolute precision from an instrument that has a digital scale, they are usually the easiest to use and interpret. Precision of digital instrumentation look it up! When reading a digital scale it is best to refer to the manufacturers specifications as to the precision of the instrument. For example, consider a typical top-loading digital balance in a chemistry laboratory. According to the manufacturer the precision of a mass measurement depends upon the mass measured: 1. If the mass is less than 100 g then the balance reads to 3 decimal places (mg) and has a stated precision of ± 0.001 g. Daley 2 9-Oct-09

2. If the mass is greater than 100g the balance reads to 2 decimal places (cg) and has a stated precision of ± 0. 01 g. In this case the readout of the digital scale and the precision are the same, no erroneous digits are shown on the digital scale. The experimenter is confident the last digit displayed is the error digit. This may not always the case, making recording of digital measurements more complicated. For example, in chemistry we use digital thermometers attached to a LabPro data acquisition system. According to the manufacturer the precision of the thermometer is ± 0.02 C, two decimal places. However, the digital readout shows four decimal places! The user must be careful to record the temperature to only two decimal places and disregard the two erroneous digits. Precision of analog instrumentation look it up or estimate from the scale. Instruments with analog scales fall into two types: 1) those that have a graduated scale and can make measurements over a range of values (e.g., ruler, thermometer, graduated cylinder, analog clock, etc) and 2) those that make a single measurement like a fixed volume of a liquid (i.e., volumetric glassware). Lets consider the single measurement instruments like volumetric glassware first and then instruments with graduated scales. Volumetric glassware single measurement devices Consider the 10-mL volumetric pipet shown to the left. This will deliver 10 ml of liquid when filled to the calibration mark, but what is the precision? All volumetric glassware should have a stated precision on the device, if not you must refer to the manufacture s specifications. For the 10-mL pipet shown here the stated precision is ± 0.02 ml. Hence, when this 10-mL pipet is used correctly, the experimenter can expect the volume delivered to be between 9.98 and 10.02 ml on a consistent bases. Graduated glassware and analog scales Analog scales with graduations are treated differently than single measurement devices. With graduated scales it is expected that the experimenter will estimate between the smallest scale division to make the measurement and determine the precision of the measurement. The distance between graduations on a ruler, thermometer, buret or other glassware may be subdivided into ones, tenths, hundreds or other divisions depending on the precision of the instrument. A 50 ml graduated cylinder, for example (see illustration), has a smallest scale division of one ml. Since the experimenter can estimate between the divisions, the volume can be measured and recorded to 1/10 ml, one decimal place. A buret, on the other hand, has a smallest scale division of 1/10 ml. In this case the volume can be estimated to the 1/100 ml, two decimal places. Therefore, an extra digit of precision is gained when the buret is used over the 50-mL graduated cylinder. For analog instruments, the precision is usually dependent upon the scale of the device. The illustration shows the top part of a 50 ml graduated cylinder. The volume is 50-mL Graduated Cylinder Scale 50 ml 40 ml Daley 3 9-Oct-09

read as 48.6 ± 0.2 ml. The last digit (6) and the precision (± 0.2) are estimated by the experimenter. The estimated precision indicates that the volume actually lies somewhere in the range of 48.4 to 48.8 ml. A final note on scales and precision Some analog instruments with scales may state the precision on the instrument. For example, a graduated pipet may state a precision of ± 0.03 ml even though the smallest scale division is 0.1 ml. The stated precision will override any estimate the experimenter might make of the precision based upon the smallest scale division. Relative precision In the previous discussion we have given the precision as an absolute value of ±x. Sometimes precision is given as a relative value to the measured quantity. For example, a 100-mL volumetric 0.2mL flask has an absolute precision of ±0.2 ml. The relative precision is x100% = 0.2%. 100.0ml Another example is a 50-ml graduated cylinder. When used to measure 25.0 ml the relative 0.2mL precision is: x100% = 0.8%. 25.0ml For an analytical balance the relative precision is extremely small for a 1-gram sample: 0.0001g x100% = 0.01%. 1g Most laboratory beakers have a precision of ±5%. Thus, a 200-mL volume would have an absolute precision of ±10 ml. Daley 4 9-Oct-09

Self-Test Answer the following questions. Check your answers by reviewing the next page. True or False 1. Digital scales always display a measurement with the correct precision (significant figures). 2. The precision of an instrument should be available from the manufacturers specifications. 3. For an analog scale, the precision can usually be determined by estimating between the smallest scale division. 4. A precision of ± 0.03 ml implies the instrument is accurate to ±0.03 ml. 5. Precision can be expressed in absolute terms or as a relative term. 6. A systematic error will affect the precision of a measurement. Problems 1. Use the illustration of a graduate glassware device to a. Read the level of the meniscus to the correct precision. b. Estimate the absolute precision of the measurement. c. Calculate the relative precision of the measurement. 2. A balance has a precision of ±0.05 g. A student obtains a mass of 3.42 g for a penny. Give the range of allowed values for the mass of the penny based on the precision. 3. A student reports a measured volume of 42.48 ml. As the reader of this volume, what absolute precision might you assign to this measurement? 4. A balance has a precision of ± 0.001 g. A sample that has a mass of about 25 g is placed on this balance. How many significant figures should be reported for this measurement? Daley 5 9-Oct-09

Answers to Self-Test True or False 1. Digital scales always display a measurement with the correct precision (significant figures). FALSE. Some scales (LabPro for example) will display erroneous digits. In this case the experimenter must round the reading to the correct precision before recording. Digital balances never give erroneous digits! 2. The precision of an instrument should be available from the manufacturers specifications. TRUE. Most manufactures supply a specification sheet with the stated precision 3. For an analog scale, the precision can usually be determined by estimating between the smallest scale division. TRUE. Unless the precision of the instrument is known, the experimenter will determine the precision by how well the smallest scale division can be visually separated and the error digit estimated. 4. A precision of ± 0.03 ml implies the instrument is accurate to ±0.03 ml. FALSE. The precision is inherent to the instrument and only determines the uncertainty of a single measurement. Accuracy is determined by calibrating the instrument against a known standard. Although a measurement may be precise systematic errors will affect accuracy. 5. Precision can be expressed in absolute terms or as a relative term. TRUE. 6. A systematic error will affect the precision of a measurement. FALSE. Systematic errors affect accuracy, random errors affect precision. Problems 1. Use the illustration of a graduate glassware device to a. Read the level of the meniscus to the correct precision. 16.5 ml. The smallest scale division is 2 ml. The meniscus appears to be just above the 16 ml line but not quite to 17 ml. b. Estimate the absolute precision of the measurement. ±0.05 ml. That would divide the smallest scale division of 2 ml into 4 discernable divisions. c. Calculate the relative precision of the measurement. 0.5mL x100% = 3% 16.5mL 2. A balance has a precision of ±0.05 g. A student obtains a mass of 3.42 g for a penny. Give the range of possible values for the mass of the penny based on the precision. The mass of the penny should be between 3.37 and 3.47 g. 3. A student reports a measured volume of 42.48 ml. As the reader of this volume, what absolute precision might you assign to this measurement? I would estimate al least ±1 unit in the error digit. That would be ±0.01 ml. 4. A balance has a precision of ± 0.001 g. A sample that has a mass of about 25 g is placed on this balance. How many significant figures should be reported for this measurement? The mass will be read to the third decimal place, 25.xxx g. There should be 5 significant figures. Daley 6 9-Oct-09