Rapid RH Portable ph Meter. User's Manual

Similar documents
INE-PHS-3E ph Meter Operating Manual

Bante210 Benchtop ph Meter Instruction Manual

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

PH700 Benchtop ph Meter Instruction Manual

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

OPERATING INSTRUCTIONS

STANDARD OPERATING PROCEDURE

GENERAL INSTRUCTIONS GENERAL PREPARATION

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

GENERAL INSTRUCTIONS GENERAL PREPARATION

Guide to ph Analysis.

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Chemistry MultiMeasure Sensor PS-2170

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

ph 5 Meter Manual The LaMotte 5 Series

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

1) A ph/mv meter or an ion meter, either line operated or portable.

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Instruction Manual HI Refractometer for Sodium Chloride Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

symphony Multisensor Probes

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

DOC /2013, Edition 1. User Manual

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

GENERAL INSTRUCTIONS GENERAL PREPARATION

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

symphony Reference Electrodes

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

10 samples per second

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

EXPERIMENT 6. Properties of Buffers INTRODUCTION

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

Instruction Manual HI Refractometer for Invert Sugar Measurements

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

phoenix Electrode Company CARBON DIOXIDE GAS-SENSING ELECTRODE INSTRUCTION MANUAL 1. A ph/mv meter or an ion meter, either line operated or portable.

[Agilent Technologies] [Electrochemistry Products] Quick Reference

ph Probe ReallyEasyData com

The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous solutions.

Manual ph Probe & Oxidation Reduction Potential Probe Models 6528A and 6528B

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Bante900P Portable Multiparameter Water Quality Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Razi Vaccine & Serum Research Institute

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Standard Operating Procedure for GLNPO Specific Conductance: Conductivity Bridge

HI Propylene Glycol Refractometer

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

phoenix Electrode Company Silver/Sulfide Ion Electrodes Instruction Manual 1. A ph/mv meter or an ion meter, either line operated or portable.

Digital Dissolved Oxygen, Conductivity, TDS and ph Meter

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

ph / Temperature Meter for Cheese with Application Specific Probe

Operating Manual. Turb 355 IR/T. Portable turbidimeter. ba75454e03 09/

ORP Probe ORP. Reads. +/-2000mV. Range. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C. Temperature range C.

COLE-PARMER INDUSTRIAL SILVER/SULFIDE ION ELECTRODE INSTRUCTION MANUAL

By D.B. Radtke, J.K. Kurklin, and F.D. Wilde. Temperature... T Equipment and supplies A Maintenance, cleaning, and storage...

Laboratory Certification Workshop

Instruction Manual Portamess 911 ph

One-hand ph/temperature measuring instrument

The Oakton Lead Ion Electrodes are used to quickly, simply, accurately, and economically measure lead or sulfate ions in aqueous solutions.

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

DPD Test N Tube Method *

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

MA882, MA883, MA884, MA885

HI Seawater Refractometer

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Instruction Manual. Waterproof Portable Colorimeter C401 / 301 / 201 / 101 / 102 / 103 / 104 / 105. Part of Thermo Fisher Scientific

ph Probes Lab vs. Process Care, Calibrations and Comparison Presented by: Michael Blackburn Technical Sales Specialist at Hach Company

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

Transcription:

Rapid RH Portable ph Meter User's Manual

This page intentionally left blank. 2

Contents 1. Introduction... 4 2. Included with the Rapid RH Portable ph Meter... 4 3. Understanding ph... 5 4. Calibrating the ph Meter... 5 5. Measuring ph of Concrete... 6 6. Additional Features of the Rapid RH ph Meter... 6 7. Storing the Rapid RH Portable ph Meter... 7 8. Additional Information... 7 9. Troubleshooting the Rapid RH Portable ph Meter... 8 10. Optional Accessories for the Rapid RH Portable ph Meter... 9 11. Technical Specifications... 10 12. Warranty Information... 10 3

1. Introduction Thank you for using the Rapid RH Portable ph Meter. The Rapid RH Portable ph Meter with its integrated smart data chip is easy to operate and compact to carry. Its sleek design encases a variety of features to help you accurately find the ph level of any solution. The Rapid RH Portable ph Meter includes: Easy to use dual-slope three-point automatic calibration with manual temperature compensation Automatic electrode slope percentage display after calibration Synchronous LCD display that shows both the ph and temperature of the solution Dual sets of buffer solution ph data (Chinese & European standards), which can be selected manually Low voltage display and 15 minute idle automatic shutdown Selectable Celsius ( C) or Fahrenheit ( F) display A portable case with room for calibration buffer solutions The Rapid RH Portable ph Meter gives you portable, accurate ph testing. 2. Included with the Rapid RH Portable ph Meter 2 1 6 7 4 5 1. 2. 3. Rapid RH Portable ph Meter 2015P-C ph electrode ph 4.00, 7.00, 10.01 buffer solutions (50 ml each) 1 set 1 pc 1 bottle of each 4. Thermometer 1 pc 5. 6F22# 9V battery 1 pc 6. Carrying Case 1 pc 7. Manual 1 book 3 4

3. Understanding ph ph is a measurement of the acidity or basicity of an aqueous solution. When ph is 7.0, the aqueous solution is said to be neutral; solutions with a ph less than 7.0 are said to be acidic (the lower the number [i.e. 2.4], the more acidic) and solutions with a ph greater than 7.0 are referred to as alkaline (the higher the reading above 7.0, the more alkaline). ph is represented on a scale of 0 14, with 0 being the highest level of acidity, and 14 being the highest level of alkalinity. Understanding the ph of a solution can help gauge the ways in which it will interact with other substances introduced to the solution, or that the solution will come in contact with. 4. Calibrating the ph Meter NOTE: Prior to initial usage, you should do a three-point calibration. (i.e., repeat below steps with all three buffer solutions [4.0, 7.0, and 10.01]. Below steps should be followed prior to each usage.) A. Use the thermometer to measure the temperature of the 7.0 ph buffer solution. B. Press the button to turn on the Rapid RH Portable ph Meter. C. Press the Up arrow or the Down arrow to manually adjust the temperature on the LCD screen to match the temperature of the 7.0 buffer solution, taken in step A, with the thermometer. D. Open the cover of the ph socket and connect the electrode to the ph meter. E. Place the ph electrode into distilled water, wash it, and then allow the probe to air dry or gently blot it dry. The electrode must also be rinsed and dried between each sample reading. F. Place the ph electrode into the ph 7.00 buffer solution, stir gently, and then hold the electrode stationary in the buffer solution. After the ph value is stabilized, press the calibration button until the LCD screen displays. Release the calibration button. The LCD screen will 5

display a flashing 7.00, and then, after a few seconds, will appear on the display. The calibration process is complete when the final ph calibration value appears on the display. 5. Measuring ph of Concrete A. Clean the area of concrete to be tested. B. Place several drops of distilled or deionized water on the concrete surface, forming a puddle approximately 1 inch in diameter. C. Allow water to sit for 60 seconds prior to testing. D. Place ph electrode into puddle for 10 seconds. E. Record ph reading on meter s digital display. F. Compare this reading with the specific flooring and/or adhesive manufacturer s installation guidelines to determine if the ph level is acceptable for their products. 6. Additional Features of the Rapid RH ph Meter A. Changing Temperature Measurement Units: To change the temperature display from C to F, press and hold the button for a few seconds until the desired change occurs. B. Low Battery Warning: A battery symbol appears on the LCD screen when the battery is at an unacceptably low level. To replace the battery, open the battery access door, and replace the existing battery with a standard or NiCad 9V battery. Be sure the battery and battery access door are properly installed before operating the ph meter. C. Power Conservation Feature: If idle, the Rapid RH Portable ph Meter will automatically power down after 5 minutes. 6

7. Storing the Rapid RH Portable ph Meter A. A small amount of protective solution is kept in the small bottle holding the ph electrode s front-end. This solution is to maintain the electrode s glass ball and junction s sensitivity to the measured solution. When taking a ph measurement, unscrew the bottle cap, bring the electrode out, and wash the electrode with pure water (see 4E on page 4). After completing a ph measurement, return the electrode into the bottle of protective solution and tighten the cap to prevent spilling of the protective solution during storing. Note: If the protective solution in the bottle looks muddy or moldy, replace with new protective solution (see 7B below) to store the electrode properly. B. To make the electrode protective solution: Dissolve 25 grams of Potassium Chloride to 100 ml pure water. Note: Do not leave the electrode immersed in pure water, protein solution, or acidic fluoride solution for a long time. Avoid direct contact between the electrode and organic oil. C. The ph meter should be kept dry and clean; especially the temperature meter and electrode outlets. If these elements become dirty or damp during storage, the ph meter may give inaccurate or failed ph measurements. Note: If the ph meter needs cleaning, lint-free absorbent cotton and ethyl alcohol can be used sparingly. 8. Additional Information A. The calibration times should be subject to the actual sampling solution, electrode capability and precision requirement. High precision measurement ( ±0.02 ph) requires more frequent calibration and highly-precise buffer calibration solutions. Normal precision measurement ( ±0.1 ph) normally requires one calibration per week. However, we recommend you recalibrate the Rapid RH Portable ph Meter in the following situations: a. The electrode has not been used for a long time, or needs replacing; 7

b. Every time after measuring the strong acidic solution (ph<2) or strong alkaline solution (ph>12); c. Every time after measuring a fluoride solution or strong organic solution; d. The temperature of the solution varies greatly from the temperature of the calibration solution. B. Because accurate ph levels in the buffer solutions are critical to accurate ph measurement, to ensure correct ph meter calibration replace each buffer solution after several uses. C. The electrode should be cleaned with distilled water and allowed to air dry before and after each use and before storing. Note: Do not use facial tissue to dry the electrode as the electrode electric potential can be destabilized and the electrode will function slowly or improperly. If necessary, a chemical solvent can be used after taking a ph measurement and before cleaning with distilled water. D. Regular cleaning and maintenance is important to maintaining the accuracy and prolonging the lifespan of your Rapid RH Portable ph Meter. For daily maintenance, gently wash the electrode with diluted water and allow to air dry before each use and before storing. For specific cleaning situations of the electrode and glass ball, see section 9B for further cleaning options. The electrode shell is made of Makrolon and should be washed often. DO NOT use carbon tetrachloride, trichloroethylene, tetrahydrofuran, or acetone to clean the electrode shell as these chemicals will dissolve the Makrolon shell. E. Although the ph electrode s standard life is one year, this lifespan may be shortened by inappropriate use or storage. After one year, replacing the ph electrode is strongly recommended to maintain accuracy during ph measurements. 9. Troubleshooting the Rapid RH Portable ph Meter A. The ph meter may occasionally freeze (the on/off button does not work at all). Solutions include: taking the battery out, putting it back, and then restarting the ph meter. 8

B. If the electrode s glass ball has been damaged by a solution or the liquid junction has been blocked by a solution, the ph electrode will become less sensitive, function slowly, or give incorrect ph readings. a. If the glass ball has developed solution deposits: Soak the electrode in a solution of 0.1 ml/l hydrochloric acid dilute for 24 hours (to make: top off the 9 ml of Acid Hydrochloric Dilute with pure water to 1000 ml); wash the electrode with distilled water; then soak the electrode in the protective solution for 24 hours. If the electrode has more serious deposits: Soak the electrode in 4% HF (hydrofluoric acid) for 3 to 4 minutes; wash the electrode with distilled water; then soak the electrode in the protective solution for 24 hours. b. To clean the electrode glass ball and liquid junction: PROBLEM: Inorganic metallic oxide Organic oil Resin macromolecule matter Protein blood ball sedimentation matter Pigments CLEANING AGENT: <1 mol/l diluted acid Diluted detergent (weak alkaline) Diluted alcohol, acetone, or ether Acidic enzyme solution (e.g. Saccharated Yeast Tablets) Diluted sodium hypochlorite disinfectant or peroxide 10. Optional Accessories for the Rapid RH Portable ph Meter A. 201-C# ph electrode (plastic shell + 1 meter of wire). B. Calibration buffer solutions (ph4.00, ph7.00, and ph10.01 types). Size: 50ml/bottle; 250ml/bottle; and 500ml/bottle. 9

11. Technical Specifications A. Measuring range: ph: (0~14.00) ph mv:±1999mv B. Precision: ph:0.01 ph mv:1 mv C. Accuracy: ph: Electronic meter: ±0.01pH D. Input Impedance: 1 10 12 Ω E. Temperature Compensation Range: 32-212 F (0-100 C) F. Memory protection battery: One 6F22# 9V Battery G. Size/Weight: 168 43 26 (mm) / 170(g) H. Work Environment: Temperature 41-95 F (5-35 C); relative humidity (RH) 85%RH non-condensing 12. Warranty Information A. The Rapid RH Portable ph Meter (electrode excluded, see below) carries a six month warranty against accidental damage. B. Only the Rapid RH ph Meter s electrode is not covered by this warranty. However, it is possible to repair/exchange the electrode if it has not been used. C. This warranty does not cover damage due to inappropriate usage, storage, or unauthorized repairs. 10

This page intentionally left blank. 11

326 Pine Grove Road, Rogue River, OR 97537 USA Worldwide Toll-Free: (844) 726-6308 Email: sales@wagnermeters.com 2017 WM Wagner Meters Part # 500-R0007-001 Rev B For more information visit: www.wagnermeters.com 12