Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Similar documents
HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

INFRARED THERMOMETER TM0819

InfraRed Thermometer with Laser Pointer

INFRARED THERMOMETER Model : TM-959

Introduction Cautions

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Dual laser + type K thermometer INFRARED THERMOMETER

Noncontact Thermometer

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Infrared Thermometer Model CA879

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

Instruction Manual SEFRAM Thermal Camera

IR/Thermistor Pen. Instruction Manual

GS-IR 8816 Series Infrared Thermometer

INSTRUCTION MANUAL DTH Fax: (503)

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

INSTRUCTION MANUAL Fax: (503)

566/568. Infrared Thermometers. Getting Started

Infrared Thermometer Model: and

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Infrared Hand-Held Thermometers

63/66/68. Infrared Thermometers. Users Manual

Non contact temperature measurement

Rapid RH Portable ph Meter. User's Manual

ph / Temperature Meter for Cheese with Application Specific Probe

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

New! 2010 Model. Model No

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

IT Series Infrared thermometer Using manual

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

High Accuracy High Speed in Your Process

Emissivity: Understanding the difference between apparent and actual infrared temperatures

One-hand ph/temperature measuring instrument

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

IR-712 IR-720 IR-730

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Part Number Range Accuracy Printing WP * Probe Special User LDC with Page Logging included Feature Cal Backlight

Designed to go where you work

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

Every object with a temperature above 0 Kelvin= -273,15 C emits

Operating instructions Infrared temperature sensor TW20xx TW21xx

Acceleration/Velocity/Displacement VIBRATION METER

Infrared Hand-Held Thermometers

Instruction Manual HI Refractometer for Invert Sugar Measurements

The Fluke 66 and 68 Infrared Thermometers

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

473 Dew Point Hygrometer

INSTRUCTION MANUAL INF Fax: (503)

Manual Weather Stations & Instruments

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Mini Environmental Quality Meter

Reflow Soldering Processes Development Using Infrared Thermography

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Today s Weather 24 Hour Forecaster

Model DIT-516/517: OPERATING MANUAL

Manual Dew point scanner PCE-DPT 1

Heat stress index. Dewpoint. pressure. altitude

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

CLOCKS MARATHON WATCH COMPANY LTD.

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

473 Dew Point Hygrometer

Sensor Technology Summary

VIBRATION METER. Instruction Manual.

Emissivity and Remote Sensing

By: Krueger and Wideman

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

RADIATION-METER TM-91/TM-92

Operating Instructions for Digital Manometer. Model: MAN-SD

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Introduction to Infrared Thermometry

THERMOFOCUS, a technological innovation

Thermometer Line. today s laboratory and field

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

473-SHX Dew Point Mirror

Sunlight and Temperature

THERMOCOUPLE CHARACTERISTICS TRAINER

Xenics Presentation. A 25 minute crash course in Thermography

Transcription:

Model ST-616CT Infrared Thermo-Hygrometer Instruction Manual reedinstruments com

Table of Contents Safety... 2 Features... 3 Specifications...4-5 Instrument Description...6-7 Operating Instructions...8-10 Battery Replacement... 11 Safety Use extreme caution when the laser beam is turned on. Do not point the laser beam to your eye, another person s eye or the eye of an animal. Do not point the laser beam toward a reflective surface that can strike your eye. Do not point the laser beam towards an explosive gas. For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com. reedinstruments com 2

Features An easy-to-use infrared thermometer and humidity meter in. one compact unit User selectable F or C Large, easy to read, backlit LCD with dual display Max and Hold function, Auto shut off Fixed 0.95 emissivity covers 90% of surface applications Includes battery and carrying case Wide range of applications Food preparation, safety and fire inspectors, plastic molding, asphalt, marine, screen printing, measure ink, dryer temperature, diesel and fleet maintenance. Field of View The meter s field of view is 8:1, meaning that if the meter is 8 inches from the target, the diameter of the object being tested must measure at least 1. Other distances are shown below in the field of view diagram. Refer to the chart printed on the meter for more information. Distance (D) to Spot Size (S) Laser reedinstruments com 3

Specifications General Specifications Temperature Range: -58 to 932 F (-50 to 500 C) Resolution: 0.1 up to 200 ; 1 over 200 Accuracy: ±2% of reading Humidity Range: 0 to 100% RH Resolution: 0.1% RH Accuracy: ±3.5% RH Optical Resolution: 8:1 Distance to Spot Size Ratio Emissivity: Fixed at 0.95 Response Time: < 1 second Display: Dual backlit LCD IR Spectral Response: 6 to 14um Sample Rate: 2.5 times/second Operating Temp.: 32 to 122 F (0 to 50 C) Operating % RH: Max. 80% RH Over Range Indication: LCD will show OL Power Off: Automatic shut offf after 10 minute, approx. Battery Life: 1 x 9V alkaline battery Dimensions: 5.9 x 3 x 1.6 (150 x 75 x 40mm) Weight: 7.1 oz (200g) Optional Accessories: Tripod (Model BS-6) reedinstruments com 4

Infrared Thermometer Specifications Range Resolution Accuracy -50.0 to 200.0 C -58.0 to 200.0 F -50.0 to -20.0 C 0.1 C + 5 C -20.0 to 200.0 C ± 2% of reading or + 2 C 200 to 500 C 1 C ± 2% of reading or + 2 C -58.0 to -4.0 F 0.1 F + 9 F -4.0 to 200.0 F ± 2% of reading or + 4 F 200 F to 932 F 1 F ± 2% of reading or + 4 F Notes Accuracy is given at 18 to 28 C (64 F to 82 F), less than 80 % RH.. Accuracy specified is for emissivity of 0.95 Emissivity settings: 0.95 fixed Distance Factor: D:S is approx. 8:1 (D=distance, S=spot) Relative Humidity / Air Temperature Specifications Range Resolution Accuracy 5.0%RH to 95.0%RH 0.1%RH + 3.5%RH -20.0 to 60.0 C 0.1 C +2 C -4.0 to 140.0 F 0.1 F + 3 F Notes 1. Accuracy is given at 18 to 28 C (64 to 82 F), less than 80% RH. 2. Reaction time humidity is about 80 sec., windstill 3. The measuring range is from 0% to 100%, however above 95% and below 5% the deviation is not specified. reedinstruments com 5

Instrument Description 1 - Laser pointer beam 2 - IR sensor 3 - %RH and Probe temperature measurement reading 4 - Infrared thermometer measurement reading 5 - Power (ON/OFF) button 6 - C/ F (IR TEMP.) button 7 - IR measurement data hold button 8-0.1º/1º(IR TEMP.) button 9 - IR temperature Laser pointer button 10 - IR measurement MAX hold button 11 - Backlight button 12 - %RH/ C/ F (Probe temperature) button 13 - %RH/ C/ F (Probe temperature) measurement data hold button 14 - %RH/ C/ F (Probe temperature) measurement MAX hold button 15 - Humidity and Probe temperature sensor reedinstruments com 6

LCD Display 1-188.8 %RH C F %RH and probe temperature measurement reading 2 - MAX (1) %RH and probe temperature MAX Hold 3 - HOLD (1) %RH and Probe temperature MAX Hold 4-1888 C F IR measurement reading 5 - C Temperature C (Celsius) 6 - F Temperature F (Fahrenheit) 7 - MAX (2) IR MAX Hold 8 - HOLD (2) IR Data Hold 9 - IR Laser Point 10 - E=0.95 IR Fixed emissivity (0.95) 11 - LOW battery indicator reedinstruments com 7

Operating Instructions ON/OFF button Read the measured IR Temperature ( C/ F) and Relative Humidity simultaneously on the LCD of the meter. The meter automatically turns itself off approximately 10 minutes after not being used. %RH / C/ F (probe temperature) button Select the Relative Humidity units (%RH) or the probe temperature (air temperature) units ( C or F) using the C/ F buttons. Selecting infrared thermometer range (0.1º/ 1º) Use the 0.1º/1º button to select the temperature range. Selecting the display resolution The thermometer allows two resolution choices: High resolution: 0.1 C or 0.1 F Low resolution: 1 C or 1 F Overload display (OL) The digital display will indicate OL when the input exceeds the measurement range selected. If measuring above 199.9º, change the resolution to 1º. Data Hold button Press the Data Hold button to freeze the reading on the display. HOLD will appear on the display. Press the button again to release the display. MAX Hold button To hold the highest reading on the LCD, press the MAX hold button. The meter reading will not change as readings change, rather it will only display the highest reading encountered since the MAX hold button was pressed. Press the MAX hold button again to return to normal operation. Backlight button Press the Backlight button to turn the display backlight function on and off. Laser Pointer Press the laser pointer button to turn the laser pointer function on and off. Only available for infrared thermometer measurements and not the relative humidity measurements. reedinstruments com 8

Infrared thermometer measurement considerations Holding the meter, point the IR sensor toward the object being measured. The meter automatically compensates for temperature deviations from ambient temperatures. Keep in mind that it will take up to 30 minutes to adjust to wide ambient temperatures. Several minutes is required after the low and before the high temperature measurements are taken. This is due to the cooling process which must take place for the IR sensor. Relative humidity measurement and air temperature considerations Always operate the instrument in such a position that you can read read the liquid crystal display (LCD) or that the digital display is directed upwards. Infrared thermometer notes: How it Works Infrared thermometers measure the surface temperature off an object. The intrument s optic reflected sense and transmitted energy is collected and focused onto a detector. The instrument s electronics translate the information into a temperature reading which is displayed on the display. The laser is used for aiming purposes only. Field off View Make sure that the target is larger than the instrument s spot size.. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size. Distance & Spot Size As the distance (D) from the object increases, the spot size (S) off the area measured becomes larger. See diagram on Page 3. Locating a Hot Spot To find a hot spot aim the thermometer outside the area of interest, then scan across with an up and down motion until you locate the hot spot. Reminders 1. Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc). See emissivity chart on Page 10. 2. The instrument cannot measure through transparent surfaces such as glass. It will measure the surface temperature of the glass instead. 3. Steam, dust, smoke, etc., can prevent accurate measurements by obstructing the unit s optics. reedinstruments com 9

Emissivity Most (90% of typical applications) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the instrument). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or painted surface. Emissivity Values Substance Thermal. Emissivity Substance Thermal. Emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Leather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium oxides 0.81 Plaster 0.80 to 0.90 Copper oxides 0.78 Mortar 0.89 to 0.91 Lron oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 reedinstruments com 10

Battery Replacement 1. As battery power is no longer sufficient, the display will show indicating that it s time to replace the current battery with a new. battery (9V). 2. Open the battery cover, remove the old battery from the instrument and replace with the new 9-Volt battery. Place the battery cover back onto the instruments. For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com. Notes reedinstruments com 11

Notes reedinstruments com 12