Progress of the NA62 RICH detector

Similar documents
Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

COMMISSIONING AND FIRST RESULTS OF THE NA62 RICH

The NA62 RICH detector

THE CERN NA62 experiment [1] aims to measure the

NA62: Ultra-Rare Kaon Decays

New Limits on Heavy Neutrino from NA62

Search for K + π + νν decay at NA62 experiment. Viacheslav Duk, University of Birmingham for the NA62 collaboration

PoS(KAON)049. Testing the µ e universality with K ± l ± ν decays

The HERA-B ring imaging Cherenkov system } design and performance

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

RICH detectors for LHCb

Particle Identification of the LHCb detector

Simulation and validation of the ATLAS Tile Calorimeter response

PoS(KAON)059. Giuseppe Ruggiero. Scuola Normale Superiore and INFN, Pisa, Italy

Status of the LHCb RICH and hadron particle identification

An Overview of RICH Detectors From PID to Velocity Spectrometers

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Muon reconstruction performance in ATLAS at Run-2

Status of the LHCb RICH detector and the HPD

PoS(KAON13)012. R K Measurement with NA62 at CERN SPS. Giuseppe Ruggiero. CERN

7. Particle identification

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

Information about the T9 beam line and experimental facilities

Results from the OPERA experiment in the CNGS beam

Calorimetry in particle physics experiments

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

The NA62 Calorimeter Level 0 Trigger Operation and Performances

The LHCb Experiment II Detector XXXIV SLAC Summer Institute, July, 2006

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

A gas-filled calorimeter for high intensity beam environments

Likelihood Methods for Beam Particle Identification at the COMPASS Experiment

The CNGS neutrino beam

b Physics Prospects For The LHCb Experiment Thomas Ruf for the LHCb Collaboration Introduction Detector Status Physics Program

R. Fantechi CERN and INFN Sezione di Pisa on behalf of the NA62 Collaboration

ALICE A Large Ion Collider Experiment

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

Κ+ p+νν : first NA62 results

New Limits on Heavy Neutrino from NA62

arxiv: v1 [physics.ins-det] 7 Dec 2018

EP228 Particle Physics

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Experimental results on the atmospheric muon charge ratio

Scientific / Technical Note

Examples for experiments that can be done at the T9 beam line

PoS(ICHEP2016)552. The Mu3e Experiment at PSI. Alessandro Bravar University of Geneva

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

The SHiP experiment. Colloquia: IFAE A. Paoloni( ) on behalf of the SHiP Collaboration. 1. Introduction

Jacopo Pinzino CERN HQL /05/2018

Performance of muon and tau identification at ATLAS

The TORCH project. a proposed detector for precision time-of-flight over large areas. Roger Forty (CERN)

Detecting ν τ s: the CHORUS and OPERA experience. Pasquale Migliozzi

arxiv: v1 [physics.ins-det] 1 Sep 2009

Recent results at the -meson region from the CMD-3 detector at the VEPP-2000 collider

PoS(HEP2005)177. Status of the OPERA experiment. Francesco Di Capua. Universita Federico II and INFN.

The NA62 Experiment. Seminar at LPNHE, Paris, France. Mathieu PERRIN-TERRIN. February 4, CERN, Geneva, Switzerland.

LHCb: From the detector to the first physics results

An autonomous underwater telescope for measuring the scattering of light in the deep sea

COMET muon conversion experiment in J-PARC

PoS(PhotoDet 2012)010

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. First Physics at CMS

Physics potential of ATLAS upgrades at HL-LHC

Non-collision Background Monitoring Using the Semi-Conductor Tracker of ATLAS at LHC

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

Recent Results from Fermilab Charm Experiment E791. David A. Sanders. Representing the Fermilab Experiment E791 Collaboration

Track measurement in the high multiplicity environment at the CBM Experiment

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

New Hadroproduction results from the HARP/PS214 experiment at CERN PS

Cherenkov light imaging in particle and nuclear physics experiments

Detailed performance of the Outer Tracker at LHCb

2017 NA62 Status Report to the CERN SPSC

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

PoS(EPS-HEP2015)522. The status of MICE Step IV

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond

PANDA Muon System Prototype

PoS(NOW2016)003. T2K oscillation results. Lorenzo Magaletti. INFN Sezione di Bari

PAMELA: a Satellite Experiment for Antiparticles Measurement in Cosmic Rays

The HARP Experiment. G. Vidal-Sitjes (INFN-Ferrara) on behalf of the HARP Collaboration

October 4, :33 ws-rv9x6 Book Title main page 1. Chapter 1. Measurement of Minimum Bias Observables with ATLAS

Validation of Geant4 Physics Models Using Collision Data from the LHC

Cherenkov Detector Simulation

Lecture 16 Light transmission and optical detectors

(a) (b) Fig. 1 - The LEP/LHC tunnel map and (b) the CERN accelerator system.

LHCb Calorimetry Impact

PoS(EPS-HEP2015)572. Search for the dark photon in the π 0 decay. R. Fantechi INFN - Sezione di Pisa and CERN

The achievements of the CERN proton antiproton collider

Identifying Particle Trajectories in CMS using the Long Barrel Geometry

Measurement of the η mass by the NA48 Experiment

V0 cross-section measurement at LHCb. RIVET analysis module for Z boson decay to di-electron

PoS(EPS-HEP 2009)048. QCD tests at NA48/2 experiment. Gianluca Lamanna Scuola Normale Superiore & INFN Pisa - Italy

Track reconstruction for the Mu3e experiment Alexandr Kozlinskiy (Mainz, KPH) for the Mu3e collaboration DPG Würzburg (.03.22, T85.

Physics at Hadron Colliders

Particle production vs. energy: how do simulation results match experimental measurements?

arxiv: v1 [physics.ins-det] 15 Oct 2018

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

SciBar and future K2K physics. F.Sánchez Universitat Aútonoma de Barcelona Institut de Física d'altes Energies

Recent T2K results on CP violation in the lepton sector

LHCb status. Marta Calvi. for the LHCb Collaboration. 103 rd LHCC meeting University Milano-Bicocca and INFN

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Particle Detectors A brief introduction with emphasis on high energy physics applications

Transcription:

Home Search Collections Journals About Contact us My IOPscience Progress of the NA62 RICH detector This content has been downloaded from IOPscience. Please scroll down to see the full text. (http://iopscience.iop.org/1748-0221/9/01/c01054) View the table of contents for this issue, or go to the journal homepage for more Download details: IP Address: 208.76.253.8 This content was downloaded on 16/09/2016 at 01:45 Please note that terms and conditions apply. You may also be interested in: Kaon Identification at NA62 Francis Newson Precision tests of the Standard Model with Kaon decays at CERN Karim Massri The kaon identification system in the NA62 experiment at CERN SPS Bozydar Wrona Prospects for K+ -- \pi+\nu \nu observation at CERN in NA62 F Hahn, the NA62 Collaboration, G Aglieri Rinella et al. The NA62 experiment at CERN Gianluca Lamanna Status of the NA62 liquid krypton electromagnetic calorimeter Level 0 trigger processor V Bonaiuto, L Federici, A Fucci et al. The FPGA based Trigger and Data Acquisition system for the CERN NA62 experiment B Angelucci, R Fantechi, G Lamanna et al.

PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB RECEIVED: November 25, 2013 ACCEPTED: January 1, 2014 PUBLISHED: January 29, 2014 13 th TOPICAL SEMINAR ON INNOVATIVE PARTICLE AND RADIATION DETECTORS 7 10 OCTOBER 2013 SIENA, ITALY Progress of the NA62 RICH detector Massimo Lenti 1 INFN Sezione di Firenze, Via G.Sansone 1, 50019 Sesto Fiorentino (FI), Italy E-mail: lenti@fi.infn.it ABSTRACT: NA62 is the last generation Kaon experiment at CERN. Its main goal is to collect about 100 K + π + ν ν events with 10% background. This implies to collect more than 10 13 K + decays with a backgound rejection factor better than 10 12. The challenging aspect of the experiment is the suppression of Kaon decays with branching ratioes up to 10 orders of magnitude higher than the signal and similar experimental signature, such as K + µ + ν. To this purpose good PID (Particle IDentification) and kinematic rejection are required. Precise timing is also needed to correctly associate the π + with the parent K + in an high rate environment. A RICH (Ring Imaging Cherenkov) detector is proposed as PID element, to identify µ contaminating the π sample in the 15 35 GeV/c momentum range with inefficiency lower than 1% and to measure the arrival time with precision smaller than 100 ps. It will also be a key element for the NA62 trigger. A vacuumproof cylindrical vessel with 4 m diameter, 17 m long, will be filled with Neon gas at atmospheric pressure. The Cherenkov light will be reflected by a mosaic of 20 hexagonal mirrors with 17 m focal length and collected by 2000 photomultipliers. The progress in the construction of the detector is described: the installation will start in January 2014, with completion foreseen in time for the first physics run of the NA62 experiment in the fall of 2014. KEYWORDS: Particle identification methods; Cherenkov detectors; Timing detectors; Large detector systems for particle and astroparticle physics 1 On behalf of the NA62 RICH collaboration: G. Anzivino, A. Bizzeti, F. Bucci, V. Carassiti, A. Cassese, P. Cenci, R. Ciaranfi, V. Duk, J.R. Fry, E. Iacopini, M. Lenti, M. Pepe, M. Piccini. c CERN 2014, published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article s title, journal citation and DOI. doi:10.1088/1748-0221/9/01/c01054

Contents 1 The NA62 experiment 1 2 The NA62 RICH detector 3 3 The mirror system 3 4 The photomultipliers 4 5 Test beam with a RICH prototype 6 6 Conclusions 6 1 The NA62 experiment Kaon physics has been very important in the history of Particle Physics as a tool to discover new phenomena like parity and CP violation but also as a probe of new physics (charm and top masses). At present Kaon decays with a Pion and a Neutrino-Antineutrino pair are considered the golden channels to have access to new physics above the TeV scale. Their branching ratio can be calculated in the framework of the Standard Model with a precision of 10% thanks to isospin symmetry and in particular for the charged Kaon decay it is predicted to be [1]: BR ( K + π + ν ν ) = (7.81 ± 0.75 ± 0.29) 10 11 (1.1) where the first error is due to uncertainties on the input parameters and the second one to long distance corrections. The high sensitivity for new physics has the price of a very small branching ratio. The measurement by the Brookeven E787/E949 experiments is based on few signal candidates [2]: BR ( K + π + ν ν ) = ( 1.73 +1.15 ) 1.05 10 10 The difficulty for this measurement relies not only in its very low probability but also in its experimental signature: a charged track and nothing else. The NA62 experiment at CERN was proposed [3] to collect about 100 signal events with a 10% background. The NA62 experiment will be located in the CERN North Area in the ECN3 cavern, previously used by the NA48 experiment, some parts of which will be recycled. The primary beam, 400 GeV/c momentum Protons from the SPS accelerator, will impinge on a beryllium target producing a secondary charged beam that will be collimated and focused in a 100 m long beam line. This secondary beam will have 75 GeV/c momentum with a 6% fraction of positive Kaons. The Kaon momentum will be measured by a beam spectrometer made by three stations of silicon pixel detectors (GTK); Kaons will be identified thanks to a Cherenkov detector (KTAG). The Kaon decay region will be in vacuum and will comprise a Pion spectrometer made by four stations of (1.2) 1

Figure 1. The NA62 experiment. straw chambers with a dipole magnet providing a p t kick of 270 MeV/c, followed by a RICH detector, an electromagnetic calorimeter and a Muon Veto system; several annular calorimeters will be present along the decay region to veto Photons from other Kaon decays. The total length of the experiment, from the target to the beam dump will be about 270 m. The particle rate seen by the detectors on the beam line will be 750 MHz, while the decay region detectors will afford a 10 MHz rate. A picture of the NA62 experiment can be seen in figure 1. The most probable (63.4%) charged Kaon decay is with one Muon and a Neutrino (referred to as K µ2 ) and can mimick the signal if the Muon is misidentified as a Pion. What is needed is a total suppression factor of 10 12 of the K µ2 background to match the required accuracy of the measurement. Knowing the momentum modulus and direction of the charged Kaon before its decay and of the Pion (Muon) after the decay, the missing mass can be reconstructed: m 2 miss = (P K P π ) 2 (1.3) where P K and P π are the four-momenta of the Kaon and Pion, respectively, measured with the GTK and the Pion spectrometer; according to the (very detailed) simulation of the experiment, a K µ2 suppression factor of 10 5 can be reached cutting on the missing mass. The usual way to distinguish between Pions and Muons is by means of the very different stopping power in matter, using a Muon Veto system: a suppression factor of 10 5 can be reached while below that level electromagnetic radiation showering and nuclear interactions make it impossible to separate Pions from Muons. A further 10 2 suppression is achieved by means of a RICH detector. At the offline level events are selected with a Pion momentum between 15 and 35 GeV/c where the simulation indicates the best compromise between signal acceptance and background rejection. To reconstruct the missing mass it is necessary to match a track in the beam spectrometer, which sustains a 750 MHz track rate, with a track in the Pion spectrometer (10 MHz), a wrong matching introducing important tails in the missing mass distribution. To minimize the wrong 2

Flanges with 2 x 1000 PMts Length > 17 m; Ø = up to 4m Mirror mosaic Filled with Neon Gas at 1 atm. Figure 2. The NA62 RICH detector. matching, a very good time resolution, of the order of 100 ps, is required both for the Kaon track (given by the GTK) and the Pion track (provided by the RICH). 2 The NA62 RICH detector Pions and Muons must be separated in a momentum range between 15 and 35 GeV/c: this drives the choice of the Cherenkov radiator, which must have a radiation threshold a bit smaller than the lower momentum bound to maximize the separation capability. Neon gas at atmospheric pressure almost perfectly matches this requirement: the Cherenkov threshold for Pions is 12.5 GeV/c, which also guarantees full efficiency above 15 GeV/c. Neon has also a very small chromatic dispersion and very good transparency to UV light. On the other hand the very small index of refraction (n 1 = 62 10 6 ) calls for a very long radiator to get enough Cherenkov Photons to be detected. The NA62 RICH detector will be made by a container (vessel) 17 m long. A drawing of the detector can be seen on figure 2. The RICH vessel will be made in structural steel, divided into 4 cylindrical sections of different lengths and decreasing diameters (between 4 m at the beginning and 3.4 m at the downstream end). A conical cap at the upstream end will connect the RICH detector to the vacuum decay region and will have two protruding cylinders to lodge 2000 photomultipliers. An aluminum beam pipe, 157 mm in diameter, will cross all the RICH container to allow undecayed beam particles to pass undisturbed; thin aluminum entrance and exit windows will minimize the interactions of Kaon decay products with the detector. The total RICH inner volume to be filled by Neon gas is 200 m 3. The gas will be kept slightly above atmospheric pressure with a density stability better than 1% and a contaminants level well below 1%. Before introducing pure Neon, the RICH container will be first fully evacuated; when the detector will be full of Neon, it will be sealed. 3 The mirror system The Cherenkov light emitted by a charged particle crossing the Neon gas will be focused into a ring by means of a spherical mirrors system. At the downstream end of the detector, 18 hexagonal 3

Figure 3. The NA62 RICH mirror system. mirrors (700 mm wide, 25 mm thick, made of glass) and two special semi-hexagonal mirrors (close to the center, where the beam pipe will pass) will be located (see figure 3). All these mirrors have a focal length of 17 ± 0.1 (corresponding to the upstream end of the detector, where the photomultipliers will be located) and a reflectivity in excess of 90% over a wavelength range 195-650 nm. The high optical quality is guaranteed by a D 0 parameter smaller than 4 mm (the D 0 of a spherical mirror is defined as the diameter of the smallest circle where 95% of the reflected light is collected, produced by a point source placed in the center of curvature). All the mirrors will be supported by a panel which must be as light as possible to minimize particle interactions. An aluminum honeycomb panel, divided into two halves and 50 mm thick, will do the job. Each hexagonal mirror will have a 10 mm wide hole in the rear surface (the part not optically prepared): an aluminum dowel will be inserted in this hole to support the mirror. The dowel will be connected to the support panel by means of a hollow aluminum cone. The mirror alignment will be achieved by means of two aluminum ribbons, 200 µm thick, 10 mm wide, pulling horizontally the mirror at ±45 o with respect to the vertical direction; a third vertical ribbon will be used to avoid the mirror rotation. The pulling ribbons will be moved with micrometric precision by means of piezo-electric motors, with a maximum force of 20 Newtons and a maximum range of 35 mm. A picture of the alignment system for a single mirror can be seen on figure 4. 4 The photomultipliers The RICH detector will be equipped with 1952 single anode photomultipliers (PMTs), divided into two parts (corresponding to the two halves in which the mirror system is split, in such a way to avoid the shadow induced by the presence of the beam pipe) and positioned in the focal plane of the mirror system (see figure 2). A compromise between good quantum efficiency, small size, good time resolution and cost led to the choice of the Hamamatsu R7400U-03 photomultiplier [4]. Its cylindrical shape has a diameter of 16 mm with a 8 mm diameter active area. This device is made 4

Figure 4. The alignment system for a single mirror. The piezo-electric motors, on top of the picture, are outside particles acceptance. The pulling ribbons have three branches: one attached to the rear surface of the mirror, one at the piezo-electric motor and the last one is used to transform the movement from vertical to horizontal. A third, vertical, ribbon is visible on the left of the picture; it is attached to one side of the rear face of the mirror to avoid its rotation. Figure 5. Left: geometrical dimensions of the Hamamatsu R7400U-03 photomultiplier [4]. Right: photocathode radiant sensitivity as a function of incident light wavelength for some Hamamatsu photomultipliers. by 8 dynodes, with a gain of 1.5 10 6 at 900 volts. It has a UV-glass entrance window and a bialkali photocathode and it is sensitive to light with wavelength between 185 and 650 nm, with a peak around 420 nm, where about 20% quantum efficiency is achieved. At 900 volts the output for a single photoelectron is 240 fc, with a fast signal peaking at 200 µa or 10 V (over 50 Ω); this signal has a typical rise time of 0.78 ns and a fall time of 1.6 ns, with a time jitter (FWHM) of 280 ps. A drawing with the photomultiplier dimensions and the response spectrum can be seen on figure 5. The PMTs will be packed in a honeycomb structure with minimum distance of 18 mm. The light will be collected to the photomultiplier active area with a Winston cone 18 mm large at the 5

beginning and 7.5 mm large in front of the photomultiplier, 23 mm high, drilled in an aluminum disk separating the Neon gas contained inside the detector from the outside air where the PMTs will be positioned; a quartz window at the end of each Winston cone will guarantee gas tightness and light transparency. The reflectivity of the Winston cone will be improved by insertion of aluminized mylar foils on its inner surface. The analog output of each photomultiplier will be digitized with a fast discriminator (the NINO ASIC [5]) operated in time over threshold mode. The LVDS (Low-Voltage Differential Signaling) output will be sent to a HPTDC (High Performance Time to Digital Converter [6]) embedded on a DAQ (Data AQuisition) board called TEL62. The RICH information will be used in the first level of the trigger of the NA62 experiment. 5 Test beam with a RICH prototype The RICH project was validated with a strong R&D program based on a detector prototype with the same length (17 m) and radiator (Neon at atmospheric pressure), but much smaller in transverse dimensions (the vessel had an inner diameter of 600 mm), and equipped with only one spherical mirror (of circular shape, 500 mm in diameter) with a focal length of 17 m. The RICH prototype was installed in the CERN North Area ECN3 cavern. In 2007 a first version of the prototype, equipped with 96 PMTs, was exposed to a 200 GeV/c momentum negative Pions beam. The average number of fired photomultipliers (hits) was 17 (due to the smaller acceptance given by the available number of PMTs) and the time resolution per event was measured to be 70 ps [7]. In 2009 an improved version of the prototype, equipped with 414 PMTs, was exposed to a positive Pions beam with tunable momentum between 15 and 50 GeV/c. Positrons were also present in the beam and they gave rise to an average number of 20 hits; Pions had an average number of hits between 7.5 at 15 GeV/c and 17.5 at 35 GeV/c momentum. The Cherenkov angle resolution was 70 µrad for 35 GeV/c momentum Pions with a time resolution of 60 ps. Some distributions can be seen on figure 6. Pion-Muon separation versus momentum was measured in the following way: for each nominal momentum point two data samples were collected, one with Pions at the same momentum and another with Pions with the same velocity of nominal momentum Muons. A total Muon suppression between 15 and 35 GeV/c momentum (weighted with the Muon spectrum of the final experiment) was measured to be 0.7%, with the suppression at 35 GeV/c below 2% [8] as can be seen on figure 7. 6 Conclusions The NA62 RICH design is very demanding and it has been validated with a strong R&D program. The RICH installation schedule foresees the vessel delivery by january 2014, the mirrors mounting in late spring and the photomultipliers installation in summer 2014. At the end of the summer 2014 the beam pipe will be inserted and the detector will be evacuated and then filled with pure Neon. In october 2014 the commissioning of the apparatus is expected, in time for the first physics run of the full NA62 experiment. 6

pions pions pions Figure 6. NA62 RICH prototype results from the 2009 test beam. Top left: distribution of fired photomultipliers (hits) for positrons and Pions at 15 GeV/c and 35 GeV/c momentum. Top right: number of hits as a function of Pion momentum. Bottom left: Cherenkov angle resolution versus Pion momentum. Bottom right: event time resolution versus Pion momentum. Figure 7. NA62 RICH prototype results from the 2009 test beam: Muon suppression and Pion loss probability versus momentum. The integrated Muon suppression, weighted with the final experiment Muon spectrum is indicated on top of the figure; taking into account some systematic errors, a conservative Muon suppression of 0.7% is quoted in the text. 7

References [1] J. Brod, M. Gorban and E. Stamou, Two-loop electroweak corrections for the K πν ν decays, Phys. Rev. D 83 (2011) 034030. [2] A. V. Artamonov et al., New measurement of the K + π + ν ν branching ratio, Phys. Rev. Lett. 101 (2008) 191802. [3] NA62 collaboration, Technical Design, NA62-10-07 (2010). [4] Hamamatsu Photonics K.K., http://www.hamamatsu.com. [5] F. Anghinolfi, P. Jarron, A.N. Martemiyanov, E. Usenko, H. Wenninger, M.C.S. Williams and A. Zichichi, NINO: An ultra-fast and low-power front-end amplifier/discriminator ASIC designed for the multigap resistive plate chamber, Nucl. Instum. Meth. A 533 (2004) 183. [6] J. Christiansen, HPTDC High Performance Time to Digital Converter, CERN, Geneva, 2004, Version 2.2 for HPTDC version 1.3. [7] G. Anzivino et al., Construction and test of a RICH prototype for the NA62 experiment, Nucl. Instum. Meth. A 593 (2008) 314. [8] B. Angelucci et al., Pion-Muon separation with a RICH prototype for the NA62 experiment, Nucl. Instum. Meth. A 621 (2010) 205. 8