A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes

Similar documents
ICP-MS. High Resolution ICP-MS.

Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS)

PERSPECTIVE STABLE ISOTOPE RATIO MS

IRMS. perspective. Isotope Ratio Mass Spectrometry.

of mass spectrometry

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

ICPMS Doherty Lecture 1

PERSPECTIVE STABLE ISOTOPE RATIO MS

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Low level Os isotopic measurements using multiple ion counting

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it?

Mass spectrometric determination of the surface compositions of ethanol water mixtures

The Analyzer. We will deal mainly with magnetic sector instruments here although we will talk briefly about other separation methods later.

Interface (backside) & Extraction Lens

Nu Plasma II - Collector Configuration

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Determination of Ni isotopes in nickel material from the Rossi reactor

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Thermo Scientific Neptune XT MC-ICP-MS

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

dating of geological samples by laser ablation ICPMS

High-Precision Lead Isotope Ratio Coupled Plasma Multiple Collector. Measurement by Inductively Mass Spectrometry

Evaluating the precision of Pb isotope measurement by mass spectrometry

Asymmetrical features of mass spectral peaks produced by quadrupole mass filters

Hiden HPR60 Molecular Beam Mass Spectrometer System

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

vacuum analysis plasma diagnostics surface science gas analysis

CEE 772: Instrumental Methods in Environmental Analysis

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Defining quality standards for the analysis of solid samples

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

Confirmation of paper submission

Spectrometric Methods of Analysis. OCN 633 Fall 2013

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Fergus Keenan Shona McSheehy Julian Wills

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

ICP-Mass Spectrometer

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

Calibration of Particle Instruments in Space Physics

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Extrel Application Note

Exploring new fields of Applications using Multi Collector Magnetic Sector MS

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Autenticity control, provenance testing and fraud detection using mass spectrometry

Harris: Quantitative Chemical Analysis, Eight Edition

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Precise lead isotope ratios in Australian galena samples by high resolution inductively coupled plasma mass spectrometry

Accurate and precise determination of lead isotope composition in selected geochemical reference materials

Translational Biomarker Core

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

Sample Analysis Design PART II

Effect of Sampling Depth on the Analyte Response in Laser Ablation Inductively Coupled Plasma Mass Spectrometry

Automation of the radiochemical procedures for the sequential separation of radionuclides

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Introduction to GC/MS

1. The range of frequencies that a measurement is sensitive to is called the frequency

Antonio Simonetti University of Notre Dame

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

MS Goals and Applications. MS Goals and Applications

Plasma Interface Element2

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

LAACHER SEE REVISITED: HIGH SPATIAL RESOLUTION ZIRCON DATING IMPLIES RAPID FORMATION OF A ZONED MAGMA CHAMBER -

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Jong-Sik Ryu, Min Seok Choi, Youn-Joong Jeong and Chang-sik Cheong *

OES - Optical Emission Spectrometer 2000

Geol. 655 Isotope Geochemistry

FRONTIER RESEARCH ON EARTH EVOLUTION, VOL. 2. Research Program for Data and Sample Analyses, Institute For Research on Earth Evolution (IFREE) 2

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

The 30-Minute Guide to ICP-MS

Secondary Ion Mass Spectroscopy (SIMS)

Secondary ion mass spectrometry (SIMS)

UNIVERSITY OF CALGARY. Measurement of the absolute isotopic composition and atomic weight

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

AGE DETERMINATION OF HIGHLY ENRICHED URANIUM

The NKS-NORCMASS guide to beginners in ICP-MS

of numerous north-south trending Miocene and volcanic centres and lava flows. For

NUCLE A R FORENSIC S INTERN ATION A L TECHNIC A L WORK ING GROUP ITWG GUIDELINE THERMAL IONISATION MASS SPECTROMETRY (TIMS)

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Transcription:

International Journal of Mass Spectrometry 181 (1998) 51 58 A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes N.S. Belshaw a, *, P.A. Freedman b, R.K. O Nions a, M. Frank a,y.guo a a Department of Earth Sciences, Oxford University, Parks Rd, Oxford, OX1 3PR, UK b Nu Instruments Ltd, Wrexham Industrial Estate, Wrexham, Wales, UK Received 5 March 1998; accepted 18 August 1998 Abstract A new generation multiple collector plasma source mass spectrometer (PSMS) produced by Nu Instruments Ltd is evaluated. The instrument has a double-focusing Nier Johnson analyser with laminated magnet and a novel variable dispersion ion optical arrangement, enabling all masses to be located in the centre of the Faraday collectors of a fixed static array. The performance of the instrument has been assessed through the analysis of NBS-981 Pb using a Tl doping technique with Faraday collector efficiencies and amplifier gains determined independently. A second method of analysis involves comparison of interspersed standard and sample Pb measurements with effective gains for each collector determined from the standards. In both cases the repetition of Pb isotope measurement is competetive with the thermal ionization mass spectrometry (TIMS) double-spike method. (Int J Mass Spectrom 181 (1998) 51 58) 1998 Elsevier Science B.V. Keywords: Plasma; Mass spectrometer; Multiple collector; Isotopes; Lead 1. Introduction The importance of the plasma source mass spectrometer (PSMS) as an analytical tool is now well established. It offers clear advantages as a rapid means of determining elemental and isotopic abundances in both liquids and solids. The inherent simplicity of the plasma source combined with its ability to ionise all elements has opened up new areas of mass spectrometric application and its success in measuring isotope ratios of elements with poor thermal ionization efficiencies have made it either preferable or a serious alternative to thermal ionisation * Corresponding author. mass spectrometry (TIMS). The performance of TIMS instruments in terms of analytical sensitivity, precision, and accuracy of isotope ratio measurement have been documented extensively over the last few decades but these aspects of the plasma source instruments are yet to be fully evaluated. Previous studies (e.g. [1,2]) have compared PSMS and TIMS and emphasized the restriction of TIMS to elements with relatively low ionisation energy. In contrast, the plasma source is able to ionise elements with high ionization energies and samples may be presented to the mass spectrometer with minimal chemical preparation. Initial attempts to measure isotope ratios using plasma source instruments were made with quadrupole mass analysers and their accuracy was limited by the inherently poor peak shape 1387-3806/98/$19.00 1998 Elsevier Science B.V. All rights reserved PII S1387-3806(98)14150-7

52 N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 and restricted analytical precisions to 0.1 0.5%. This situation underwent a dramatic improvement with the coupling of the plasma source to a multiple collector magnetic sector mass spectrometer [1,2]. The first instrument of this type was produced by Fisons Instruments and there are now some notable successes in the application of this instrument to problems in the geological sciences (e.g. [3 7]). The purpose of this article is to describe the configuration of a new generation instrument that is also commercially produced by Nu Instruments, UK. The instrument is configured as a full double-focusing instrument in order to handle the ion energy spread that also includes a fast laminated magnet and a fixed multiple collector array coupled to a variable dispersion zoom lens system. 2. Instrument configuration 2.1. Source The source of the instrument is similar to that used elsewhere (e.g. [1,2]) and comprises a Fassel-type ICP torch with automated radio frequency power matching. This configuration has been evaluated so far for aqueous samples using either a peristaltic pump and Meinhard nebuliser, or a microconcentric nebuliser. The interface region of the instrument consists of a water cooled Ni sampler cone located in front of a Ni skimmer cone operating at approximately 4 kv. These cones are followed by the extraction and transfer optics (Fig. 1). The extraction optics (Lens 1) arrange for the passage of a circular cross-section ion beam to a transfer assembly (Lens 2) in which the ion beam is converted from circular to slit geometry in order to meet the entrance requirements of the mass analyser. These extraction and transfer stages are housed in separately pumped chambers that are interconnected by small apertures that allow ions to pass from the plasma at atmospheric pressure into the analyser, but at the same time severely restrict the conductance of Ar gas. In this arrangement the ion-pumped mass analyser operates at 3 10 9 mbar. Fig. 1. Schematic layout of the variable dispersion PSMS. The mass spectrometer is a double-focusing Nier Johnson arrangement with a fast-scanning, low heat dissipation laminated magnet. The detector array consists of 12 fixed Faraday collectors and three fixed ion counting channels. The mass dispersion of the ion beam is varied using a zoom lens system situated between the magnet and collector array. (Lens 1 circular geometry extraction lens; Lens 2 transfer optics Y lens; Lens 3 Z lens; ESA 35 cm radius electrostatic sector; Monitor ion energy window signal monitor; Magnet 25 cm radius laminated magnet; Zoom lens variable dispersion ion optics; Detector Array 12 saphire/ceramic fixed collectors.) 2.2 Spectrometer The mass analyser (Fig. 1) is a Nier Johnson double-focusing geometry with a 35 cm radius electrostatic sector followed by a 25 cm radius laminated magnet. Vertical or Z focusing in the analyser is achieved using both a long focal length lens before the electrostatic analyser (ESA) and the fringe field at the magnet exit pole. The detector array consists of 12 sapphire/ceramic Faraday collectors, with a fixed 2.5 mm spacing between them on the mass focal plane. The magnification of the final image is adjusted by a pair of quadrupole lenses that act as a zoom lens and focus ion beams optimally into the collectors (Fig. 1). At high mass, where the physical separation of adjacent masses is small, the ion beams are collected in adjacent collectors. At lower masses every second or higher order collector is used rather than imposing a large demagnification of the ion beam. Observation of

N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 53 peak shape show that this approach introduces minimal aberrations. The multiple collector has three channels of ion counting using discrete dynode electron multipliers and a retardation filter for measurements at higher abundance sensitivity. The magnet is laminated and achieves high scan rates with low heat dissipation the magnet has no special cooling and remains cool even at high mass. This ion optical configuration offers advantages over mechanically adjustable multiple collectors, or a fixed static array of collectors without variable dispersion. Because magnetic/electrostatic switching is fast it is possible to measure the isotope composition of two or more elements on the same sample in the same analytical procedure with minimal loss of time. Such a procedure with mechanically adjustable collectors is too slow to be useful. 2.3. Electronics and control The control and monitoring of the instrument is via an external PC that operates under WinNT or Unix. The computer is interfaced through an intelligent controller that handles real-time tasks including tuning of the rf plasma, monitoring of the source and the analyser pressures, and reading the collector signals. The analyses reported here were obtained using the Unix-based (Linux) software. 3. Analytical procedure 3.1. Background Isotope ratios measured using plasma source instruments exhibit a large mass bias relative to accepted values that are the result of processes operating at the plasma spectrometer interface. These result in the preferential transmission of heavier ions by 1% per atomic mass unit in the Pb isotope mass range. This mass bias shows little time dependence under normal operating conditions, in contrast to the mass fractionation occurring in thermal ionisation where the isotope ratios show a small and time-dependent bias, usually towards the lighter isotopes. The correction procedures employed for mass fractionation effects in TIMS are also applicable to the discrimination effects in plasma source mass spectrometers. Thus, for the TIMS analysis of an element such as Sr or Nd the correction factor applied for discrimination may be derived from the measurement of the nonradiogenic isotope ratios such as 86/88 Sr, 146/144 Nd. A similar correction procedure is used here. For Pb on the other hand, where only 204 Pb is without a radiogenic contribution, the optimal TIMS procedure is to use a double spike (e.g. [8 10]) or to limit fractionation through careful control of filament temperature. With the PSMS a different approach may be adopted by exploiting the chemical independence of the mass bias imposed on all species extracted from the plasma. The technique of Tl doping is used to obtain an estimate of the mass discrimination from the 205/203 Tl ratio that is then applied to the isotopes of Pb. Measurements of standard materials have demonstrated that different elements with isotopes in a similar mass range may be used to derive valid correction factors, certainly at the precisions so far achieved [1 3]. An alternative measurement procedure is possible with a plasma source instrument similar to that used, for example, in carbon or oxygen stable isotope analysis. In this case samples are referenced to measurements of standards before and after the unknown, an approach that depends on either minimal or time-independent discrimination. 3.2. Experimental In this article the capabilities of the new variable dispersion instrument have been assessed using NBS- 981 and a sample of ferromanganese crust for which TIMS measurements of Pb isotopes are available. The repetition of Pb isotope ratio measurement has been assessed using two approaches: (1) Measurements of Tl-doped NBS-981 solutions were taken over a period of several weeks to determine the long-term stability and the repetition of isotope ratio measurement. Tl was added to standard Pb in a 1:1 concentration ratio to ensure similar signal levels for the major isotopes of Pb and Tl and minimise error propogation during mass bias correction. The gains of the Faraday col-

54 N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 lectors were derived from a calibration using Ag isotopes. This calibration technique uses the quadrupole lenses to vary the mass dispersion to calibrate two adjacent Faraday collectors using 107 Ag and 109 Ag. This involves holding one isotope of Ag in a reference collector while simultaneously altering the magnet and zoom lenses to switch the other isotope between two other collectors to be calibrated. In this manner the relative gain factor between two collectors may be rapidly determined to precisions 20 ppm and the relative gains of all collectors in the array may be similarly determined. Ag is particularly useful for this calibration because it possesses two isotopes of similar abundance and the analyser setting required for the calibration routine is within the useful magnification range of the zoom lens; (2) measurements of Pb isotope ratios in NBS-981 solutions were taken from a series of runs carried out over a period of several weeks in order to assess the precision and accuracy of the system using the standard sample standard reference technique. In this approach measurements of the standard are used to correct for all instrument effects during the measurement of the unknown, including collector gains and mass bias. Samples of unknown and NBS-981 Pb standard dissolved in 2% HNO 3 were introduced into the mass spectrometer using a Cetac MCN-6000 microconcentric nebuliser. Standards and samples were run in various sequences in order to assess the precision, accuracy and repeatability of measurement when operating the instrument using Tl doping and standard sample bracketing. A typical analysis with 208 Pb 5 10 11 A had a duration of 20 min with the ion beam varying by less than 10% over the analysis period. Particular care was taken to check and minimise memory in the Cetac nebuliser. Using careful acid and alcohol cleaning this could be reduced to negligible proportions. A careful examination of the background in the Pb mass region failed to reveal any resolvable contribution from Hg isotopes. 3.3. Instrument setup The spectrometer was operated in static collection mode with the respective isotopes of Pb (204, 206, 207, 208) and Tl (203, 205) positioned in Faraday collectors by adjusting the magnetic field and zoom lens voltages. Ion beams were centred in all the collectors to better than 5% of half-height peak width whereas beam drift during a 15 min analysis was observed to be 2% of half-height peak width. The relative peak flats of the collectors have been measured using the plasma source by repeated scanning of the beams across the collector slits while measuring ratios, and are seen to be better than 50 ppm over 30% of the half-height peak width. The relative gains of the Faraday collectors are stable to 20 ppm over a period exceeding 5 weeks, using the calibration technique with 107 Ag and 109 Ag described above. 3.4. Data acquisition The system was operated under computer control with samples, standards, and washes being selected automatically using a Cetac Auto sampler (ASX-100). Sample runs were preceded by an acid wash using 2% HNO 3 for 10 20 min in order to minimise any Pb memory from the sample introduction system. Data was acquired in blocks of 20 ratios with 10 s integration times. Background measurements of 20 s duration precede each block and were usually averaged over the complete analysis. An average run comprised four data blocks representing 800 s of signal integration. 4. Results 4.1. Comparison with ion counting statistics For NBS-981 and a 208 Pb ion beam of 4 10 11 A, the typical standard errors over 200 s of measurement are shown for Pb and Tl isotope ratios in Table 1. The standard errors for the 208/206 Pb, 207/206 Pb, and 206/204 Pb ratios are typically 12, 15, and 60 ppm, respectively, which is approximately a factor of two worse than the theoretical ion statistical errors of 5, 7, and 30 ppm (Table 1).

N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 55 Table 1 Comparison of measurement precisions with theoretical ion statistical errors for Pb isotope analyses on the plasma multiple collector mass spectrometer Ratio m a (ppm) Approx. signal ISE b (ppm) 208/206 12 208 4 10 11 A 5 207/206 15 207 2 10 11 A 7 206/204 60 204 1 10 12 A 30 205/203 12 205 4 10 11 A 5 a One standard error on measurements from a typical analysis lasting 200 s. b Ion statistical error calculated for signal levels observed in a typical analysis. 4.2. Tl-doped analyses The measured 205 Tl/ 203 Tl ratio in the Nu Plasma instrument is usually 2.43, which differs from the accepted value of 2.387.001 by approximately 1.8%, corresponding to a mass bias of 0.9% per atomic mass unit. This appears to be typical for plasma source instruments. The bias factor may be derived from a fractionation law either linear, power, or exponential. The discrimination in this instrument appears to be described well by using an exponential relationship of the form Rt/Rm m 1 /m 2 f where Rm, Rt are the measured and true ratios, m 1, m 2 are the masses of interest, and f is the correction factor per atomic mass unit. The correction also depends upon the value chosen for Rt, in this case the true 205 Tl/ 203 Tl ratio, and it should be noted that the uncertainty in the accepted value is significantly greater than the precision of measurements reported here. The 208/206 Pb, 207/206 Pb, 206/204 Pb ratios obtained using the Tl-doping technique as described above are shown in Fig. 2. The results for 80 analyses are displayed as a histogram in each case. The overall statistics for the data sets at 2 are 100, 70, and 400 ppm for 208/206 Pb, 207/206 Pb, and 206/204 Pb ratios, respectively. This repetition is competetive with careful TIMS measurements. The values measured for 208/206 Pb, 207/206 Pb, and 206/204 Pb are 2.1665, 0.91463, Fig. 2. Results of a series of Pb isotope ratio measurements of NBS-981 using a Tl-doping technique with correction for mass discrimination based upon the difference between the measured and accepted 203/205 Tl ratio. The data were acquired over a period of 4 weeks. The mean 208/206 Pb, 207/206 Pb, and 206/204 Pb ratios are given against the histograms together with two standard deviations. and 16.932 using a value of 2.3875 for the 205/203 Tl correction, which is in good agreement with measurements made by Hirata [11] using a Fisons Instruments Plasma-54. His published values for 208/206 Pb, 207/206 Pb, and 206/204 Pb of 2.1664, 0.91462, and 16.931 use a power law combined with a modified external 205/203 Tl correction. In both cases the measured values are slightly different from those of Todt et al. [8] with 208/206 Pb, 207/206 Pb, and 206/204 Pb values of 2.1670, 0.91458, and 16.936, respectively. At this stage it is not known whether these small differences

56 N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 the mass bias correction alters the calculated Pb ratios and is therefore somewhat arbitrary. These effects are currently the subject of further investigation. 4.3. Sample-standard procedure Fig. 3. An assessment of the repetition of Pb isotope ratio measurements in NBS-981 using the standard sample standard technique. The standard was used to determine correction factors including discrimination and Faraday gains relative to the Todt et al. [8] reference values for NBS-981. These were applied by interpolation to the samples. The repetition of these measurements are shown with 2 errors as ppm deviation from the Todt et al. [8] values. The repetition is competetive with the best double-spike Pb isotope ratio measurements by TIMS. represent real differences in the measured materials, result from contamination, or are an artifact of uncharacterised instrumental contributions and fractionation effects. Adjustment of the 205/203 Tl value used to determine Fig. 3 displays measurements of NBS-981 taken over a period of several weeks during extended runs of 4 h each. The data are displayed as deviations from the Todt et al. [8] values and alternate measurements are used to correct for mass bias and amplifier gain variation. This corresponds to running an unknown sample with normalisation to measurements of the reference standard (NBS-981). This procedure is slower but appears to offer higher precision of Pb isotope analysis achievable with the current configuration. Each point in the plot represents 15 min of data bracketed by the measurement of the standard and displayed as the ppm deviation from expected value with error bars indicating the internal precision of the individual analyses (2 m ). Because the measurements were taken during extended instrument runs over a period of several weeks the horizontal axis may be viewed as time. The errors observed in repeated measurements of NBS-981 bracketed by standard samples are displayed as deviations from the reference value. 208/206 Pb, 207/206 Pb, and 206/204 Pb show deviations of 40, 40, and 250 ppm, respectively, using this approach. These values are higher by a factor of 2 3 than the internal precisions recorded in each case that are 16, 16, and 85 ppm, respectively. Although poorer than the internal statistics, these confidence estimates are superior to those derived so far using Tl doping. The reasons for this are in part the absence of the propagated errors associated with Tl normalisation, but there may be other sources of error in the Tl-doping method yet to be understood. The results are certainly competetive with 202 Pb 205 Pb double-spike [8 10] methods using TIMS and should become the method of choice. 4.4. TIMS/PSMS comparison In order to compare the relative precisions and accuracy of Pb isotope ratio measurement by multiple

N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 57 Fig. 4. Comparison of conventional TIMS and PSMS Pb isotope ratios in a depth profile of a ferromanganese crust. The PSMS Pb isotope ratios were calculated using the Tl-doping method. (All errors are 2 external.) collector plasma PSMS and TIMS on geological materials a series of samples taken from a ferromanganese crust have been analysed. For both the TIMS and PSMS measurements samples were dissolved in 6M HCl and Pb extracted and purified using HBr anion exchange chromatography following previously reported techniques [12]. The samples were analysed for Pb isotopes by the conventional TIMS methods and by PSMS using the Tl-doping technique described above. Sample sizes were typically 1 mg and solution aliquots in 2% HNO 3 used for PSMS were doped 1:1 with Tl. The sample solutions were 1 ml with 0.5 ppm Pb. The PSMS results are typically 10 times more precise than TIMS values, as shown for 208/206 Pb ratios in Table 2. The Pb isotope profiles for 206/204 Pb, 207/206 Pb, and 208/206 Pb are compared in Fig. 4. In all cases the PSMS results are substantially more precise than the conventional TIMS analyses. Table 2 A comparison of 208/206 Pb measurements from ferromanganese crust measured by TIMS and PSMS. Sample numbers represent position in a depth profile Sample TIMS ( 2 ) a PSMS ( 2 m ) a 1 2.0717 (18) 2.0717 (2) 2 2.0728 (") 2.0720 (") 3 2.0751 (") 2.0750 (") 4 2.0766 (") 2.0750 (") 5 2.0710 (") 2.0729 (") 6 2.0757 (") 2.0712 (") 7 2.0703 (") 2.0700 (") 8 2.0651 (") 2.0640 (") a Displayed errors are 2 external derived from repeated measurements of SRM NBS-981. Acknowledgements This research has been supported by a grant from the Natural Environment Research Council. References [1] A.J. Walder, P.A. Freedman, J. Anal. At. Spectrom. 7 (1992) 571. [2] A.J. Walder, I. Platzner, P.A. Freedman, J. Anal. At. Spectrom. 8 (1993) 19. [3] J.N. Christensen, A.N. Halliday, D.-C. Lee, C.M. Hall, Earth Planet. Sci. Lett. 136 (1995) 79.

58 N.S. Belshaw et al./international Journal of Mass Spectrometry 181 (1998) 51 58 [4] B. Luais, P. Telouk, F. Albarede, Geochim. Cosmoschim. Acta 61 (1997) 4847. [5] P.D.P. Taylor, P. De Bievre, A.J. Walder, A. Entwistle, J. Anal. At. Spectrom. 10 (1995) 395. [6] J.N. Christensen, A.N. Halliday, L.V. Godfrey, J.R. Hein, D.K. Rea, Science 277 (1997) 913. [7] A.N. Halliday, D.-C. Lee, J.N. Christensen, M. Rehkämper, W. Yi, X. Luo, C.M. Hall, C.J. Ballentine, T. Pettke, C. Stirling, Geochim. Cosmochim. Acta 62 (1998) 919. [8] W. Todt, R.A. Cliff, A. Hanser, A.W. Hofmann, Geophys. Monograph 95 (1996) 429. [9] J.D. Woodhead, F. Volker, M.T. McCulloch, Analyst, 120 (1995) 35. [10] J.D. Woodhead, J.M. Hergt, Chem. Geol. 138 (1997) 311. [11] T. Hirata, Analyst, 121 (1996) 1407. [12] H.F. Ling, K.W. Burton, R.K. O Nions, B.S. Kamber, F. von Blanckenburg, A.J. Gibb, J.R. Hein, Earth Planet. Sci. Lett. 146 (1997) 1.