SOKKIA C0,LTD. 1-1, TOMIGAYA 1-CHOME, SHIBUYA IKYO, 151 JAPAN PHONE 'U TFLEX SURSOK J2851

Similar documents
Cleveland State University

SET5W WATERPROOF TOTAL STATION

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

SURVEYING INSTRUMENTS DT7C DT20C. Electronic Digital Theodolite OPERATOR'S MANUAL

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

DWT-10 Instruction Manual

Automatic Level NP-732

GT-510/510L series Instruction Manual

DT220 DT520 DT520S DT520A DT520AS DT620 DT620S

Fig. 1. instrument is in the case

1. PARTS OF THE INSTRUMENT

Digital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee

~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

22X Builder s Transit Level Model No Instruction Manual

22X Builder s Level Model No Instruction Manual

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

LEAPERS, INC. RED/GREEN DOTS

CIV : THEODOLITE ADJUSTMENT

SET4B; Electronic Total Station

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

NcSTAR SHOOTER II SERIES SCOPE

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

5-25x56 PMII PSR Illuminated with Double Turn

H050 E 97.1.DF.2. Automatic Levels AS-2 / AS-2C

Carlson CR Robotic/Reflectorless Total Station

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

EE 1/3.5х14 U EE 1/3.5х14 U

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Directions for use

2-7x32. Instruction manual

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

5-25x56 PMII PSR With Double Turn

Operating Manual 1.1-4x24 Zenith x24 Zenith

RT-6 Riflescopes. User Guide

Total station LEICA TPS

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

PLI Support Guide: Robotic Total Station Field Calibration

Instruction Manual. Made in Japan

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

Bright Advance Corporation

S5 SERIES Rifl escope Rifl

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

RP-100 TELESCOPE Instruction Manual

C A S S I N I TRACKER

Welcome to purchase and use our products and thank you for your confidence in our company s products!

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patented ACSS.308/.223 HUD DMR Reticle. Advanced Combined Sighting System

x Builders Level Service Manual

RP-200 TELESCOPE Instruction Manual

Second Focal Plane MOA

10 - Celestron Telescope II: Operation

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

One-Year Limited Warranty

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

OASIS WIRELESS WEATHER STATION

SURVEYING INSTRUMENTS LDT520 LDT520S. Laser Digital Theodolite. Class 3R Laser Product OPERATOR'S MANUAL

Polar Alignment of LX200R and Ultra Wedge For The Southern Hemisphere by Chris James

3--Rv.ei. value ANGLE MEASUREMENT...' CONTENTS

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

GP3130R GP3130R3 Gyro Station

Leveling. 3.1 Definitions

PULSE TOTAL STATION GPT-3000(L)N SERIES

Instruction Manual. Model #: (Reflector) Lit #: / 06-07

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

PRIMARY ARMS 4-14X44 FRONT FOCAL PLANE SCOPE WITH PATENT PENDING ACSS HUD DMR 5.56 RETICLE PA4-14X44FFP-ACSS-HUD-DMR-5.56

Red and Green Dot Sight FF26002 USER MANUAL

WARNING: Ensure weapon is not loaded prior to mounting riflescope.

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

SpecterOS4x Optical Sight Operation Manual

DETERMINATION OF AREA OF POLYGON BY CHAIN AND CROSS STAFF SURVEY 1. AIM:

Circular Motion and Centripetal Force

Dual Red or Green Electronic Dot Sight Instruction Manual

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

JC-1000 Instruction Manual

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

C4 PLUS RIFLESCOPES User Guide

WEATHER STATION FIELD GUIDE

AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

'-. MICROMEr II. The MICROMET8 II is shipped assembled except for the Filar Eyepiece, Micrometer Stage, and Standard Vise.

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

LT8-300LTU Owner s Guide

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

AGES CF600PM. 50 mm Telescope w/ AZ Pan Tilt Mount Instruction Manual. WARNING! SUN HAZARD: Never look directly at the sun with this device.

High Resolution High Sensitivity SDR Super Wide Dynamic Camera

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

Cleveland State University

Transcription:

SURVEYING INS Electronic heodolite SOKKIA C0,LTD. 1-1, TOMIGAYA 1-CHOME, SHIBUYA IKYO, 151 JAPAN PHONE 03-3405-5211 'U. 03-3465-5203 TFLEX SURSOK J2851 OPERATOR'S MANUAL

MEMO CONTENTS 1. PRECAUTIONS 2. PARTS OF THE INSTRUMENT..... 1 3. FEATURES... 3 4. BATTERY MOUNTING AND CHECK/Compensation of 4 verticalangle... 5. KEY FUNCTIONS... 6 6. DISPLAY SYMBOLS..... 8 7. SETTING UP THE INSTRUMENT... 9 7.1 Centring and levelling... 9 7.2 Focussing and target sighting... 11... 8. INDEXING VERTICAL AND HORIZONTAL CIRCLES 13 9. DT4 ONLY: ANGLE AND OPTICAL DISTANCE MEASUREMENT... 14 9.1 Key operations for angle measurement... 14 Zero set: Measure angle between 2 points... 14 Angle hold: Set horizontal angle t~ a value... 15 Horizontal angle selection: Angle repetition mode... 16 vo vertical angle mode... 17 Display and reticle illumination... 18 9.2 Error codes... 19 9.3 Optical distance measurement: Stadia survey... 20 10. DT4 WITH EDM: ANGLE AND DISTANCE MEASUREMENT... 21 10.1 EDM combinations and mounting... 21 10.2 Simultaneous angle and distance measuring procedure 24 10.3 Error codes... 28 11. CHECKS AND ADJUSTMENTS... 29 12. INSTRUMENT PARAMETERS AND CHANGING PARAMETER OPTIONS... 37 APPENDICES: A. Indexing vertical circle by face left, face right sightings... 42 B. Battery selection/external power supplies... 43 C. Standard accessories... 45 D. Optional accessories... 46 SPECIFICATIONS/STANDARD EQUIPMENT... 48 MAINTENANCE... 51 1. PRECAUTIONS a) When the DT4 is not used for a long time, check it at least once every three months. b) Handle the DT4 with care. Avoid heavy shocks or vibration. c) If any problems are found with the rotatable portion, screws or optical parts (e.g. lens), contact our agent. d) After removing the DT4 from the carrying case, close the case to exclude dust. e) Never place the DT4 directly on the ground. f) Never carry the DT4 on the tripod to another site. g) Protect the DT4 with an umbrella against strong sunlight and rain. h) When the operator leaves the DT4, the vinyl cover should be placed over the instrument. i) Always switch the power off before removing the internal battery. j) Always remove the battery from the DT4 before returning it to the case. k) Do not wipe the display 0, keyboard Q or the carrying case with any organic solvent. I) When the DT4 is placed in the carrying case, follow the layout plan. m) Make sure that the DT4 and the protective lining of the carrying case are dry before closing the case. (The case is hermetically sealed; if moisture is trapped inside, damage to the instrument could occur.) Tribrach clamp locking screw IMPORTANT When the DT4 leaves our factory, the tribrach clamp @ is locked with a screw. Loosen it and leave it loose.

2. PARTS OF THE INSTRUMENT O Handle @ Instrument height mark O Internal switch cover (For servicing only) O Display O Keyboard O Lower clamp cover O Lower clamp O Tribrach clamp O Base plate (D Circular level adjusting screw @ Circular level (B Levelling foot screw @ Tribrach @ Horizontal circle positioning ring @ Optical plummet eyepiece @ Tubular compass slot QD Battery, BDCPl @ Sensor index adjustment cover @ Power switch @ Horizontal clamp @ Horizontal fine motion screw @ Data output connector OD External power source connector @ 0 index mark dif Oo mark @ Plate level @ Plate level adjusting screw @ Vertical clamp @ Vertical fine motion screw @ Telescope eyepiece MAINTENANCE a) Wipe off any moisture if the instrument gets wet during operation. b) Always clean the instrument before returning it to its case. The lens requires special care. Dust it off with the lens brush first, to remove minute particles. Then, after providing a little condensation by breathing on the lens, wipe it with a soft, clean cloth or lens tissue. c) Store the instrument in a dry room where the temperature remains fairly constant. d) Check the tripod for loose fitting and loose screws. @J Optical plummet focussing ring @ Telescope reticle adjustment cover g) EDM connector @ Objective lens Telescope focussing ring @ Peep sight @ Handle securing screw The specifications and general appearance of the instrument may be altered at any time and may differ from those appearing in catalogues and the operator's manual.

Standard Equipment 3. FEATURES @ The DT4 can be used not only as a highly-accurate, electronic digital theodolite, but as an electronic total station when combined with the REDmini2 or RED2A/L. @ Both the horizontal and the vertical circles are provided with 0 index points. The horizontal index value is stored in the short-term memory, so that even after power is lost (i.e. battery change or automatic power cut-off), the previous index position can be recovered when the instrument is switched on and the circle is indexed again. @ The tilt angle of the vertical axis is measured by an internal sensor. The vertical angle can be automatically compensated for this tilt angle and the compensated angle displayed. Main unit... 1 Vinyl cover..... 1 Carrying case SE30... 1 Sunshade..... 1 Shoulder strap..... 1 Lens cap... 1 Plumb bob... 1 Battery BDC21 Adjusting pins... 2 (including R6P X 4)... 1 Screwdriver... 1 Operator's manual... 1 Tubular compass... 1 DT4 Field guide... 1 Brush... 1 @ The DT4 has an internal memory which stores the instrument parameter settings. The parameter functions can be changed by key operation and the new settings are memorized even after power off. @ Any standard "AA" size batteries, rechargeable Ni-Cd or alkaline type (i.e. LR6 or R6P) batteries can be used. e A RS-232C data-output connector is provided for use with a data collector or external computer. The DT4 can transmit horizontal and vertical angle data when used without EDM, and transmit slope distance, horizontal and vertical angle data when an EDM is being used to measure the distances.

4. BATTERY BDC21: MOUNTING AND CHECK Battery release cover Release button L '$ - - : 1 " *t m. I 4 P F: T 1 g The n C C -, U. -6 C 1) Ensure that the power switch @ is OFF. 2) Mounting the battery: a) Match the battery guide with the hole in the instrument battery recess. b) Press the top of the battery until a click is heard. C) Close the battery release button cover. 3) Removing the battery: a) Open the battery release cover. b) Press the release button downwards. c) Remove the battery. 4) lnstrument and battery check: Turn the D14 power switch @ ON. The audio tone sounds and all the display symbols are shown on the display while the instrument performs self-diagnostic checks. When the instrument has successfully completed the checks, the remaining battery power is displayed as a numeric code for three seconds: Code 0..... 1.5 hrs (e.g. Alkaline 1... 1.5-10 hrs R6P batteries 2... 10-15 hrs at 25 C) display of 3 7 indicates that the instrument is ready for vertical and horizontal circle indexing. Measuring mode Horizontal angle Vertical angle Measuring time Sensitivity of levels Plate level Circular level Optical plummet Image Magnification Minimum focus Data output Self diagnostic function Power-saving cut-off Display of feet units Operating temperature Power supply Power source Working duration DT4 only Instrument height Size without handle with handle Weight Right/Left/Hold/Repetition 0" at zenith/ 0" horizontal on face left/ 0" horizontal +90 / vertical angle) Less than 0.5 seconds Erect 3X 0.1 m Asynchronous serial RS232C compatible Provided 30 minutes after last key operation Available -20 C to 50 C (-4 F to 122 F) Detachable battery BDC21 (4.8-6 V) 15 hours at 25 C (5 hrs at -20 C) (Alkaline batteries "AA" size X 4) 236 mm (193 mm from tribrach dish) 143(W) X 165(D) X 286(H) mm 143(W) X 165(D) X 338(H) mm DT4 5.2 kg (with battery DT4S 5.3 kg and handle)

SPECIFICATIONS/STANDARD EQUIPMENT Telescope Length Aperture Magnification Resolving power Image Field of view Minimum focus Stadia ratio Additive constant Horizontal circle Type Minimum display Vertical circle TY Pe Minimum display Accuracy Horizontal Vertical Automatic compensator TY Pe Minimum display Range of compensation Display Angle range Distance range 165 mm 45 mm 30X 3" Erect 1 "30' (26 m/ 1000 m) 0.9 m 1 : 100 0 Incremental with zero index 5" (0.001 gon/0.02 Mil) Incremental with zero index 5" (0.001 god0.02 Mil) Standard deviation of mean of measurements taken in positions I and I1 (DIN 18723) 5" (0.002 gon10.02 Mil) 5" (0.002 gon/o.o2 Mil) Selectable on/off Liquid 5" (0.001 gon/0.02 Mil) +3' LCD double &digit display on each face t 1 999"50'55"/ t 3999.999 gonl t 19999.98 Mil (t999.909%) 9999.999 m 1 32808.33 R If ;7 dlf d is displayed, this indicates that the battery voltage is too low for measurement. Turn the power switch off and replace the dry cell batteries in the battery case as follows: 5) Changing the dry cell batteries: Remove the battery from the DT4. Push down and slide open the battery case cover. Install the four new "AA" size batteries in the directions indicated inside the Note on automatic vertical angle compensation When the -'L mark is shown on the display, the vertical angle is automatically compensated for small tilt errors. The internal tilt sensor has a range of +-3' and a resolution of 5". Instrument parameters : See pages 37-41. -5 c* -?-L - 4 Parameter 3 can be used to swltch off and on the automatic vertlcal angle compensatlon; for example, the automatic cornpensatton should be " off I the display IS unsteady due to vlbratlon or strong wind. g* --,y-**m4/ -*-- *-Fee &- 5-5- --p&* -& - 7 g

5. KEY FUNCTIONS The upper functions are accessed by pressing key. i.e.: To obtain the % function press + 6. and the required SEL e Select the required instrument parameter option. (See page 37) m e Select slope distance, horizontal distance or height difference for distance measurements. TRK TRK e Select/release tracking mode of REDmini2. ( I?*T~ + ) m e Transfer to angle and distance measurement mode. Startlstop distance measurements. 010 c Selectlrelease vertical angle display.(,=t; + W ) m e Return to angle measurement mode. OSET OSET e Set horizontal angle to zero. ( ET + m ) m e Select horizontal angle to right, left or by repetition. H1 e Holdlrelease horizontal angle. (!@ + ) m e Illuminate display and reticle of telescope. ENT e Enter the parameter setting into the memory (See page 37). e Selectlrelease shift mode (upper function). Note: A single audio tone is output when a key is pressed. A double audio tone warns of a key misoperation. 6) Electronic field books SDR series The SDR series can collect and store all angle and distance values output from the DT4 data output connector a. The stored data can be verified and printed in the field, then transmitted by cable or modem to an IBM-compatible office data processing system for final computation, SDR printing and plotting. Printer Computer I Plotter SDR features: @ Simple operation with clear menu and program display prompts. @ Wide choice of recording parameters. @ Recorded data can not be cleared from the memory until it has been transmitted or printed. @ Additional programs and data can be input to the SDR from an external computer. SDR series Specifications: Power source: "AA size batteries Memory type: Keyboard: Display: Baud rate: Operating temperature: Weight: (X41 CMOS 33 keys LCD 300, 600, 1200, 2400, 4800, 9600 bps 7) Interface lfla for the HP41CV Using this interface, the DT4 can transmit angle and distance data to a HP41CV computer.

Appendix D. Optional accessories 1) Diagonal eyepiece DE17 ( @ The diagonal eyepiece is convenient for Solar Fllter MAO4A) near-vertical observations and in places where space around the instrument is limited. Remove the telescope eyepiece by unscrewing the mounting ring, and screw in the diagonal eyepiece. The DT4 has two measurement modes and one parameter setting mode. When it is switched on (and the vertical and horizontal circles are indexed by rotating the telescope and upper part respectively), it is automatically in the angle measurement mode. measurement 2) Eyepiece prism EP3 The syepiece prism is convenient for steep observations up to 60" from the horizontal, and has an attached solar filter. I I I oarameter I L@I < 1 ketting mode 1 3) Solar filter EF2 For observations to the sun, and where glare is present. C+ Angle measurement mode DT4 accepts: (Parameter 4) Circular compass CP8 Mount the CP8 on the standards after removing the carrying handle. Before use, screw loosen the clamping screw on the underside of the compass. After use, re-clamp the screw. 5) Target sets TGI and TG2 The TGI and TG2 targets can be mounted TG~ T G ~ on the standard tribrach. An illumination device (standard accessory) can be attached to the back of the target plate for surveying in low light conditions. The target heights are 233 mm. e Angle and distance measurement mode DT4 accepts: o Instrument parameter setting mode * DT4 accepts: (REDrnini2 only) :~!~lsili1hl& * In parameter setting mode, the key and E key function as SEL and ENT respectively. *

6. DISPLAY SYMBOLS Appendix C. Standard accessories Shift ( V Vertical angle (0' at zenith), V Vertical angle (0" horizontal on face left) V Vertical angle (0" horizontal t90 ) Angle or distance value or error code H m, Compensated angle / Ox- Vertical angle gon ' EDM power on Feet Horizontal angle right H *= Horizontal angle left H m, Horizontal angle repetition Horizontal angle hold H m A Slope distance - A Horizontal distance AI Height difference 1) Tubular compass CP7 (accuracy t l ") To mount the CP7, slide it into the tubular compass slot @. To use, loosen the clamping screw to free the compass needle. Turn the instrument in the face left position until the compass needle bisects the index lines. The telescope is now aligned with magnetic north. After use, tighten the clamp to fix the compass needle and remove it from the instrument. 2) Plumb bob 4) Handle Tribrach 4 clamp If the weather is calm, or for initial tripod centring, the plumb bob can be used for centring. To use, unwind the plumb bob cord and attach it to the hook inside the centring screw. Use the cord grip piece to adjust the cord length. The DT4 instrument can be removed from the tribrach by rotating the tribrach clamp anticlockwise and carefully lifting the instrument up. (The DT4S has a shifting tribrach for quick centring, and the instrument can not be removed.) The carrying handle O can be removed from the instrument by unscrewing the handle securing screw @ and sliding the handle to the side. When replacing the handle, ensure that the securing screw is fully tightened.

External power supplies Internal 7 battery BDC21 C /'-. AC Adaoter Charger CDC14 IOOV AC CDCl4A 120V AC CDC14D 220V AC (15 hours charger) 7. SETTING UP THE INSTRUMENT 7.1 Centring and levelling 1) Ensure that: a) The tripod head is approximately level, and over the surveying point. b) The tripod shoes are firmly fixed in the 2) Place the DT4 on the tripod head. Support it with one hand and insert and tighten the centring screw with the other. Cable (6V) EDC3 6V DC BDCI2 r 1 hour cigarette lighter charger CDCl3 (12V DC) 3) Focus on the surveying point: a) Turn the optical plummet eyepiece @ to focus on the reticle. b) Turn the optical plummet focussing ring @ to focus on the surveying point. L (220-240V AC) (120V AC) (CDCIZ, IOOV AC) 1 hour quick charger CDCI 5 (100-240V AC) screb Optical plummet 4) Adjust the levelling foot screws @ to Levelling centre the surveying point in the optical @ plummet reticle. Observe the off-centre direction of the circular eve1 @ bubble. External battery adapter EDC14 Car ciaar liahter cable - - EDC4 cable EDC5 Use the DT4 only with the above battery combinations. Note: When using the DT4 with an external power source, leave the BDC21 in place to balance the weight on the axes. Adjust Optical plummet 5) Shorten the tripod leg nearest the bubble tripod 5 leg direction or extend the leg farthest from @ this direction. Generally, two tripod legs must be adjusted Circular level to centre the bubble.

6) Using the horizontal clamp @, turn the upper Appendix B. Battery selection/external power supplies part of the instrument until the plate level @ is parallel to a line between levelling screws Battery selection A and B. Any good-quality "AA" size batteries may be used in the DT4, Centre the plate level bubble using levelling although alkaline batteries normally last longer than the other types. screws A and B. However, battery characteristics change with the working temperature. A B Note: The bubble moves towards a clockwise- From the graphs it can be seen that for sub-zero temperatures rotated foot screw. re-chargeable Ni-Cd batteries will last the longest. Bubble movement Choose the battery type best suited to the working temperatures. A B 7) Turn the upper part 90" The plate level is now perpendicular to a line between levelling screws A and B. Centre the plate level bubble using levelling screw C. C f-7 8) Turn the upper part a further 90" and check.. the bubble position. 4.0 V-! Ni-Cd Manganese (R6P) A B If the bubble is off-centre, either perform the plate level adjustment described on page 29 or carefully adjust levelling screws A and B in equal and opposite directions to remove half of the bubble displacement. Again turn the upper part a further 90" and use levelling screw C to remove half of the displacement in this direction. The bubble should now remain in the same position for any position of the upper part. (If it does not, repeat the levelling procedure.)

p indexed. APPENDICES Appendix A. Indexing vertical circle by face left, face right readings. Like all theodolites, the DT4 will have a vertical index error. The vertical index can be determined, and the index error removed, by the following procedure: FT-7 c,. [G, 3 C -- 1) Carefully level the DT4 and switch the instrument on. 2) Change the instrument parameter 2 to option F1: (See page 38) i.e. Vertical circle indexing by face left. face right readings. The prompt v : is displayed. Face 3) In the face left position, accurately sight a left clear target at a horizontal distance of about 30 m. 0 SET Press D. The prompt v Z is displayed. 4) On face right, accurately sight the same Face target. r~ght OSET Press VtFT m again. When the vertical circle has been indexed, the vertical angle is displayed. The horizontal angle should now be Note: The vertical and horizontal circles must be re-indexed each time the DT4 is switched on. Ensure that the instrument is switched off when moving it to a new location. The following steps are different for the DT4 and DT4S: DT4: 9) Look through the optical plummet eyepiece. @ Loosen the centring screw slightly. Carefully slide the instrument over the tripod head until the surveying point is exactly centred in the reticle. Re-tighten the centring screw. 7.2 Focussing and target sighting 10) Repeat procedures 6)-9) until the instrument is correctly levelled and centred over the surveying point. DT4S: 9) Turn the tribrach shifting clamp anticlockwise. Adjust the instrument position on the tribrach to centre the surveying point. Tighten the shifting clamp to fix the instrument in the centre position. Note: The DT4S shifting tribrach can be adjusted up to t8mm without moving the base plate. 1) Look through the telescope at a bright, featureless background and turn the eyepiece clockwise, then anti-clockwise until just before the reticle image goes out of focus. Using this procedure, frequent reticle re-focussing is not necessary, since your eye is focussed at infinity.

2) Loosen the vertical and horizontal clamps and use the peep sight @ to bring the target into the field of view. Re-tighten both clamps. 3) Turn the focussing ring @ to focus on the target. Use the vertical and horizontal fine motion screws @, @ to sight the target precisely. The last adjustment of each fine motion screw should be in a clockwise direction. Check that there is no parallax between the target image and the reticle. F 1 c;:;z L L- - 1 1 m e FO: Illumination on/off using the f4 F key. f W i F1: lllumtnatton cut-off 30 seconds " after presstng the m key. (Press 113 to return to angle measurement mode) Parallax: This is the relative displacement of the target image with respect to the reticle when the observer's head is moved slightly before the eyepiece. Parallax will introduce reading errors and must be removed before observations are taken. Parallax can be removed by re-focussing with the focussing ring. G! 9 L. - P F3: bright /7\ m \L/ Note: 4) Position of the target in relation to the reticle a) When observing simultaneous horizontal and vertical angles c) When observing vertical angle Observe to the same point of the reticle when the telescope face is changed. l (Press 113 to return to angle measurement mode), -.. -. power on. m: v 3 l 1 1,L FO: Vertical angle displayed at power.-- ----- F1: On. 010 vertical angle displayed at press @ (Press to return to angle measurement mode) Parameter 1 again - 41 -

8. INDEXING THE VERTICAL AND HORIZONTAL CIRCLES FO: New RED mini2 (set tracking mode from DT4) F1: RED 2A12L press l@ (Press m to return to angle measurement mode) <- p(' Parameter 8: Distance units Y (Press &a to return to angle measurement mode) & g,.i5 L- i I - -- I L - 'ewer cut-off 30 m~nutes after last lion. Switch onloff with the DT4 switch. Turn the DT4 power switch @ ON. /.. - I,... waiting for vertical circle indexing SE... waiting for horizontal circle indexing (If v: is displayed, see page 42) 1) Vertical circle indexing Loosen the vertical clamp @, and transit the telescope completely. (Indexing occurs when the objective lens.-p P crosses the horizontal plane in face left.) The audio tone sounds and the vertical angle (V) is displayed. 2) Horizontal circle indexing Loosen the horizontal clamp @, and rotate the upper part completely. 3 (Indexing occurs when the 0 index mark @ passes the 0" mark @ on the horizontal positioning ring.) The audio tone sounds and the horizontal H :, c $3 0 h,-," et -I U -I -, U U angle (H) is displayed. Angle measurement can now begin. Note: Each time the instrument is switched on, the vertical and horizontal indices must be redetermined. However, if the instrument was only switched off for a short time (less than 5 hrs), a display of H 5E 7. means that the previous horizontal 0" position is recovered when the horizontal circle is indexed again. press 6% (Press 8@ll to return to angle measurement mode) See next page change the horizontal circle indexi ng the upper part or automatic index

9. DT4 ONLY: ANGLE AND OPTICAL DISTANCE MEASUREMENT Parameter 1: Vertical angle mode: FO: Zenith 0" F1: Horizontal O"F.L. F2: Horizontal Oaf 90" 5im C------------------------------J I i I- FO: F0 Indexing lndex~ng by rotating rotat~ng the upper part B ldexing and zero set at power on FO: 360 Degrees 9.1 Key operations for angle measurement 9.1.1 a) Set horizontal angle to zero. OSET Press @f (m) to set the horizontal angle F1: 400 gon F2: 6400 Mil 9.1.1 b) Measure the angle between two points using operation a). *\ Sight the first target A. OSET Press [G) m to set the horizontal angle display to zero as in a). Use the horizontal clamp and fine motion screw to sight target B. The displayed horizontal angle is the angle between points A and B. -14- (Press P11 to return to angle measurement mode) FO: 5" (0.001 gon/ 0.02 Mil) F1 : 10" (0.002 gon/ 0.05 Mil) press $3 (Press to return to angle measurement mode) See next page -39-

P -P Changing instrument parameter options 9.1.2 a) Hold the horizontal angle. bh Press to hold the displayed hor~zontal angle. The hold symbol is displayed. l t F0 Zenith O", face left hor~zontal QO", Nad~r 180, face r~ght hor1zontal270" F1: Face left horizontal O", Zenith 90". Face right horizontal 180, Nadir 270" F2: Face left horizontal Oo, Zenith go", To release the horizontal angle hold, again H4 press, m. 9.1.2 b) Set the horizontal circle to a required value using operation a). e.g. Set 60 00'20" to reference target R. press 6 (Press D to return to angle measurement mode) = *_ U c$ L# L( C C, Use the horizontal clamp and fine motion screw to turn the theodolite until an angle of 60 00'20" is shown on the display. (Press FO: lndexing by transitting the telescope (See page 13) F1: lndexing by face left, face right readings (See page 42) to return to angle measurement mode) - - c n n n 1, n C# C, C, C, c C, H1 Press iswrl m to hold the horizontal display, as above. Use the horizontal clamp and fine motion screw to turn the theodolite to sight on the reference target R. Press '=FT W4 m to release the display hold. Reference target R has now been set to 60 00'20". FO: Vertical circle compensator on F1 : Vertical circle compensator off Press L~ (Press to return to angle measurement mode) See next page -38-

P 1 ----p- 9.1.3 a) Select the horizontal display. m - 1 Use the key to select the required H" C,-:,-,,-;,- 1 horizontal angle display: 'JCIUUC U C.m ~OJU, L t-tatn H C h( - -, " 3 -, ' 3 U 4 (display symbol m r : horizontal angle right) (display symbol 4. : horizontal angle left) (display symbol m v r :horizontal angle by repetition) 12. INSTRUMENT PARAMETERS AND CHANGING PARAMETER OPTIONS The instrument parameter settings can be changed by key operation. To change the settings, select the parameter setting mode by the following key operation: Angle measurement l +a+ ",Ode setting confirm I 9.1.3 b) Angle repetition mode *YB...-- rirt m a) For higher accuracy reading, the angle can be measured a number of times (up to an angle total of t1999"59'55"), and the average calculated. Press until horizontal angle by repetition is selected as in 9.1.3 a) above. is displayed. b) Sight target A. c) Press @ & to set the horizontal angle torero as in 9.1.1 a) on page 14. " '.../ B d) Use the horizontal clamp and fine motion screw to sight on target B. h I/,,, 1 The angle between A and B is displayed. 1 i*b;yol(y ;U" L --' U4 e) Press to hold the horizontal angle i.;! as in 9.1.2 a) on page 15. 5 6 7 8 9 10 11 12 Angle units Angle resolution EDM combination Distance units Auto power off Illumination auto off Illumination brightness V. angle display priority * Degrees/ gon/ Mil * 5"(1 mgon/0.02 Mil)/ 1 O"(2 mgon/0.05 Mil) * REDmini2/ RED2A/ L ' Metres/ Feet On/ off " Off/ on 4 levels of brightness ' Vertical/ vertical angle * Parameter settings when the instrument left the factory. IMPORTANT: Each time the instrument parameters are changed, the new settings become the new default parameter settings.

11.5 Optical plummet a) Carefully level the DT4 and exactly centre a surveying point in the reticle of the optical plummet. A,, B f) Use the LOWER clamp0 and horizontal fine motion screwme to sight back on target A. Press m to release the horizontal angle display hold. b) Turn the upper part 180" and check the position of the surveying point in the reticle. If the surveying point is still centred, no adjustment is necessary. A -...,...,,/' B g) Use the horizontal clamp and fine motion screw to sight target B again. h The display shows the sum of the two measurements of the angle between A and 1 7 If the surveying point is not still centred in the optical plummet, adjust as follows: Use levell~ng screws @Remove half of the displacement using the levelling foot screws. @Unscrew the optical plummet reticle cover. (Double angle value) h) Repeat e)-g) to measure the angle the required number of times, then divide the total angle value by the number of times it was measured to find the average angle value. 1 /2 C Useretlcle @ Adjust the four optical plummet reticle adjustrng screws adjusting screws with the adjusting pin to centre the reticle exactly on the surveying point. For procedure, see "vertical and hori- To exit from the angle repetition routine, press tjm. 9.1.4.h vertical angle r 2 U 3 0-1: 010 Press rwrj to change to the.h vertical angle display. The 010 symbol is displayed. @ on the previous page. 8, W WARNING: Over-tightening the adjusting screws may damage the reticle. Unequal tightening of the adjusting screws may mean that the reticle will go out of adjustment. @Check the adjustment by rotating the upper part. The surveying point should remain centred in the reticle. If necessary, repeat the adjustment. oo 0% ~ I O O % Maximum displayed value = f 999.909% a angle 010 vertical angle = 100 X tan 6 where 0 = 0 +90" Press a again to return to the vertical display.

9.1.5 Illumination m Press m to illuminate the display and reticle of the DT4. fn Press B again to switch the illumination W off. Note: The selected horizontal angle mode (right or left), 0" position on the horizontal circle and vertical angle mode are stored in the short-term memory after the power is switched OFF. After about 5 hours, all the options return to their default values. This function can be useful when the battery has to be changed during survey work, or in the case of an auto power cut-off, as the horizontal angle index and angle options can be restored at power on. Parameter 10: Switch onloff the 30-second illumination cut-off facilit Parameter 12: @ While still sighting the target on face right, rij0j'j,c + -I rr -,, I et use the horizontal and vertical fine motion screws to adjust the displayed horizontal and vertical angles to the above values. @ Look through the telescope. The reticle is now slightly shifted from the target. @ Unscrew and remove the telescope reticle adjustment cover. lvertlcal rettcle h e @To move the vertical reticle line towards the target centre, use the adjusting pin to adjust the left and right adjusting screws as follows: 1 To move the reticle to the right (left), first Example TO move the reticle very slightly loosen the left (right) adjusting to the right (left) screw, then tighten the right (left) adjusting screw by this same amount. the reticle position and repeat the ure until the reticle comes close to the target centre. W/ @ To move the horizontal reticle line towards (2 Tighten.) (l the target centre, adjust the top and bot- tom adjusting screws as follows: l Horizontal reticle line I To move the reticle down (up), first very Example: To move the reticle slightly loosen the top (bottom) adjusting down (up) screw, then tighten - the bottom (top) ad- +'.:W @slightly justing screw by this same amount. Checic loosen. g (2 Tighten.). - IT- -, the reticle position and repeat the procedure until the reticle comes close to the target centre. @ Replace the reticle adjustment cover. @Tighten by the same l3 (1 Loosen). amount WARNING: Over-tightening the adjusting screws may darnage the reticle. Unequal tightening of the adjusting screws may mean that the reticle will go out of adjustment.

11.4.2 Vertical and horizontal reticle line positions a) Set up a clear target 100 metres from the DT4. Carefully level the DT4, switch on and index the vertical and horizontal circles. 9.2 Error codes If there is any fault in the theodolite function, the error codes shown in the following table will be displayed. pros-7;j b) Sight the target on face left. ~03unn Read the horizontal and vertical angles.,u A I C# I, I : v., l? : ; S ', c C) NOW sight the tarjet on face right and read r S U -I L' c -8 H :983~:3 the horizontal and vertical angles. e.g. H = 198"34'10"-18"34'00" = 18V00'10 d) Subtract the horizontal face left angle from the horizontal face right angle. The difference should be within 180" +20". e) Add the vertical face left angle and the = 36~00'15 vertical face right angle. The sum should be within 360" 3~20". If either of the values are greater than 20", repeat the above procedures. e.g. V = 9V30'10 t 26V30'05 If the difference is consistently greater than 20", the theodolite reticle should be adjusted using the following procedures: Example: when Horizontal F.L.1F.R. = 18"34'W1198"34'30" iie, error = t30 Note: Ensure that all clamps: vertical, horizontal and lower are fully tightened. * If the DT4 is rotated faster than four revolutions per second, the error indication C or C :D : is displayed. See page 28 for the error codes for distance measurement When the error indication E appears with any number other than the ones above, please contact our agent. Mean _ 18"3600" + 198"3430 +. -- @ Calculate the mean face right horizontal H 2 and vertical angles, i.e. = 198"34'15 (F.L. + F.R.) Mean 26930'20-90"30'10 horizontal = + 90" 2 - + 180" (F.R. - F.L.) vertical = + 180" 2

9.3 Optical distance measurement: Stadia survey Stadia lines The telescope reticle is provided with stadia lines (two vertical and two horizontal) which can be used to measure the target distance and elevation as follows: Stadia line separation = 1/100 of the focal m, w1-w' distance. When the telescope is horizontal: ub' Read the distance (1) on the staff between the two stadia lines, and the centre value, h2. Horizontal target distance L= 100 x l Target height difference Ah = h, - h2 When the telescope is slanted: Read the distance (I) on the staff between the two stadia lines, the vertical angle, and the centre value, h,. Horizontal target distance L = l00 X f X sin*$z or 100 X & xcos2$v Target height difference Ah = 50x f xsin2$z+hl - h2 A-, or 50x & xsin2$v+h, - h2 b) Turn the telescope vertical fine motion screw until the target is on the lower part of the reticle B. Check that the target is still positioned centrally within the vertical lines. If the target is off-centre, the following adjustment should be performed: Adjusting screws @ Unscrew and remove the telescope reticle adjustment cover @. @Very slightly loosen one vertical and one horizontal adjusting screw by a certain amount. @ Place a small piece of plastic or wood against one side of the top adjusting screw mount as a buffer. @ Look through the eyepiece and gently tap @ the piece of plastic or wood to rotate the reticle slightly...= 1 +-et=-- @ Re-tighten the two adjusting screws (loosened in @) by the same amount. WARNING: Over-tightening the adjusting screws may damage the reticle. Unequal tightening of the adjusting screws may mean that the reticle will go out of adjustment. ($3 Check the reticle perpendicularity again using procedures a) and b) above and repeat the adjustment if necessary. Replace the reticle adjustment cover. 0 After this adjustment, the vertical and horizontai reticle line positions should be checked as follows:

C f) Loosen the horizontal clamp and turn the upper part through 180". /! V g$g$g~'-~:i If the displayed vertical angle is not 90" / H" fi>fii?g" I f 5", repeat procedures b)-f) once more. 10. DT4 WITH EDM: ANGLE AND DISTANCE MEASUREMENT 10.1 EDM combinations and mounting 10.1.1 Combinations 1) The DT4 can be operated as a total station when combined with the REDmini2 or RED 2A/L EDM as follows: If the display can not be brought to 90" k5" by this method, the sensor index should be adjusted as follows: REDmini2 -=3f @Leaving the instrument in position f), remove the sensor index adjustment cover. @ Using a suitable flat-head screwdriver, adjust the internal dial until the upper display is 90 00'00". @Check the adjustment by repeating procedures b)-f). Re-adjust if necessary until the display shows a value within 90" k5" for any position of the upper part. Replace the adjustment cover. SB131 Mounting m plate 1 S827 a a Spacers S599 1 1.4 Reticle Note: The adjustments in this section are very delicate. If you experience any difficulties, please contact your SOKKIA agent. Before this procedure, check the vertical index as in 11.3. 11.4.1 Perpendicularity of the reticle to the horizontal axis a) Carefully level the DT4. Select and sight a clear target on the upper part A of the reticle line. BDCl 1A or BDC12 * When using the telescope mounted REDmini2, use the external battery BDCllA or BDC12. (The DT4 BDC2l battery should be left in place to balance the weight on the axes.) I Use the DT4 only in the combinations shown here. (When combined with other instruments, or in combinations other than those shown here, the DT4 may not display the correctly reduced horizontal distance and height difference, due to EDM mounting eccentricity.)

10.1.2 Telescope mounted system: (DT4 and REDmini2) 1) The mounting procedure for the REDmini2 telescope-mounted system can be found in the REDmini2 operator's manual. (Also see combinations diagram on the previous page.) Only use: REDmini2 counterweight SB131 Telescope mount SB27 EDM/DT4 connecting cable DOC15 (0.2 m) Note: The telescope mount SB27 should be attached to the telescope in the face left position. 2) Instructions for the horizontal alignment adjustment between the DT4 and REDmini2 can be found in the REDmini2 operator's manual. 11.3 Index error of the tilt angle sensor C a) Carefully level the DT4, switch on and index the horizontal and vertical circles. Ensure that parameter 3 is set to option F0 (see page 38). i.e. Automatic vertical compensation is available. The,If symbol is displayed. b) Loosen the horizontal clamp and turn the upper part until the telescope is perpendicular to a line between levelling screws A and B. 3) Only use target/prism set APSI 4. Instructions for target and prism height adjustments can be found in the AP series manual. Note: DT4 Instrument height = 236 mm DT4 telescope/edm separation = 88 mm L 0 SET c) Press pfft m to set the horizontal angle to zero. Use the vertical clamp and fine motion screw to adjust the telescope to the horizontal position. i.e. vertical angle (0" at zenith) reads exactly 90 00'00". d) Loosen the horizontal clamp and turn the upper part through 180" t5'. &5", correct half of the deviation with H" :g33333 -- levell~ng screw C. I e Error.) Correct halt = -70" = +in',

If the bubble is not still centred, adjust as follows: @ Use leveil~ng screws @Correct half of the bubble displacement 1 - using levelling screw C. i* 1/2 @ Use adjusting pln @C~rrecthe remaining half displacement with the adjusting pin. Note: Bubble moves away from a clock- "+ Centre - wise rotation of the adjusting screw. 11.2 Circular level @Repeat the procedures from a) untir the bubble remains centred for anv oosition of the upper part. a) Perform the plate level adjustment as in 11.7, or carefully level the plate level. b) Check the position of the circular level bubble. If the bubble is off-centre, adjust as follows: @ Note the off-centre direction of the bubble. adjusting @ Loosen the adjusting screw farthest from this direction to centre the bubble. @ Adjust all three adjusting screws until the tension of each screw tightening is the same, and the bubble is centred. WARNING: Over-tightening the adjusting screws may damage the circular level. Unequal tightening of the screws may mean that the bubble will go out of adjustment. 10.1.3 Standards yoke mounted system (DT4 and REDmini2 or RED2AlL) 1) The mounting procedure for the REDmini2 or RED2AlL standards-mounted system can be found in the relevant EDM operator's manual. (Also see combinations diagram on page 21 of this manual.) Only use: Spacers SB99 EDMlDT4 connecting cable DOC16 (0.4 m) 2) Instructions for the horizontal alignment adjustment between the DT4 and REDmini2 or RED2AlL can be found in the relevant EDM operator's manual. 3) Only use target/prism set APS13, APS35 or APS36. Instructions for target and prism height adjustments can be found in the AP series manual. Note: DT4 instrument height = 236 mm DT4 telescope1edm separation = 194 mm

10.2 Simultaneous angle and distance measuring procedure 11. CHECKS AND ADJUSTMENTS (Preparation for distance measurement) mount~ng 1) Remove the carrying handle. Level and centre the DT4 over the surveystandards ing point, and ensure that it is switched off. mountlng 2) EDM prism constant and atmospheric Q corrections: REDmini2: REDmini2 instruments (s/n Battety 8001 -) with SF9A keyboard and DOC19 DC~ 1 adaptor can change their prism constant and ppm values. However, earlier REDmini2 instruments have a fixed - 30 mm prism constant correction and 0 ppm values. Refer to your REDmini2 Operator's manual for more details. RED2A/L: Check the RED2A/2L prism constant switch position. Set the ppm dial. (Refer to the RED2A/L manual for more details) 3) EDM power supplies: REDmini2: Telescope mounted: Connect the external battery BDCIIA or BDC12 to the DT4 external power source connector @ with the cable EDC3. Or l A Standards mounted: Mount the BDCI 8 battery in the holder. RED2A/L: Mount the BDCI 1 battery in the RED2A/L. 4) Mount the REDmini2 or RED2A/L on the DT4. 5) Connect the EDM to the DT4 with the appropriate cable DOC15 or DOC16. 6) Switch on the DT4. It is important that the DT4 is periodically checked and adjusted. In addition, the instrument should be checked after transportation, long storage or when damage to the instrument is suspected to have occurred. 11.1 Plate level The glass tube of the plate level is sensitive to temperature change or shock. Adjust as follows: a) Turn the upper part of the instrument until the plate level is parallel to a line between levelling foot screws A and B. Centre the plate level bubble using level- A B ling screws A and B. A B ((F]@) Bubble movement Note: The bubble moves towards a clockwise-rotated foot screw. b) Turn the upper part 90". i.e. The plate level is perpendicular to a line between levelling screws A and B. Centre the plate level bubble using level- A B ling screw C. A C B c) Turn the upper part though 180" and check the bubble position. If the bubble is still centred, no adjustment is necessary.

10.4 Error codes If there is any fault in the EDM function, the error codes shown in the following table will be displayed. measure distances in metres. measurement. The EDM did not The EDM is not Check that instrument Turn the EDM on. Check that instrument parameter 7 has been set to the correct EDM. (Indexing vertical and horizontal circles and target/prism sighting) ftv!?3 7) Index the vertical circle by tilting the telescope through the horlzontal position In face left. lndex the horlzontal circle by rotating the upper part. 8) Switch the EDM power ON. The (D symbol appears on the DT4 display. Set the EDM measuring units to metres. 9) Align the centre of the telescope reticle with the centre of the target. In the standards yoke mounted system, sight the centre of the prism with the EDM telescope. (In the telescope-mounted system, the REDmini2 should already sight the centre of the prism.) Confirm that the reflected signal intensity is adequate by looking for the asterisk mark of the REDmini2 or by checking the signal intensity meter of the RED2A/2L. If error codes h, de d, E :G;;', E :;;':, f :: S or 8 :,' are displayed, see page 19. When the error indication f appears with any number other than the ones above, please contact our agent.

L- (Simultaneous angle and distance measurement) Note: Do not press the EDM measure button during this procedure. m 4 IF"- 1 symbol 10) Press $?qj on the DT4 to enter the angle and distance measurement mode. If tracking measurement mode is required: REDmini2: Press lg-7 g. The TRK appears on the DT4 display. (Press SHY & to return to measurement mode.) RED2AJL: Use the measurement mode switch on the EDM. m The key can now be used to recall the remaining distance options. V I$ g ;? 35:/ Each displayed value is the result calcu- 6 {?SS lated from the most recent distance i measurement. ke!l! 11) Use the key on the DT4 to select the required distance mode: (Vertical angle) Display symbol : Slope distance To return to the angle measurement mode, press PI( and switch the EDM off. (The 0 (and TRK ) symbols disappear from the DT4 display.) Display symbol Display symbol (Horizontal angle) : Horizontal distance (Vertical angle) : Height difference i m 12) Press on the DT4 to start the distance measurement. The DT4 display flashes to show that distance measurement has been started. The EDM measures the slope distance and transmits it to the DT4. The DT4 reads the angles and displays the selected distance (slope, horizontal or height) together with the appropriate angle. _L- m 13) Press on the DT4 to stop the distance measurement.