Mathematical Modelling of Blood Flow through Catheterized Artery under the Influence of Body Acceleration with Slip Velocity

Similar documents
Effect of body acceleration on pulsatile blood flow through a catheterized artery

Biomagnetic Steady Flow through an Axisymmetric Stenosed Artery

Effect of Periodic Body Acceleration in Blood Flow through Stenosed Arteries A Theoretical Model

Effect of Magnetic Field on Blood Flow (Elastico- Viscous) Under Periodic Body Acceleration in Porous Medium

Flow of a Casson Fluid Through an Inclined Tube of Non-uniform Cross Section with Multiple Stenoses

A Computational study of Bingham plastic flow of Blood through an artery by multiple stenoses and post dilatation

Available online at Pelagia Research Library. Advances in Applied Science Research, 2012, 3 (6):

Unsteady Flow of a Newtonian Fluid in a Contracting and Expanding Pipe

Pulsatile Flow of Couple Stress Fluid Through a Porous Medium with Periodic Body Acceleration and Magnetic Field

STUDY OF BLOOD FLOW THROUGH MODELLED VASCULAR STENOSIS

Research Article FDM Analysis for Blood Flow through Stenosed Tapered Arteries

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations

Analytical Solutions of Unsteady Blood Flow of Jeffery Fluid Through Stenosed Arteries with Permeable Walls

Research Article Nonlinear Fluid Models for Biofluid Flow in Constricted Blood Vessels under Body Accelerations: A Comparative Study

MHD Pulsatile Slip Flow of Blood through Porous Medium in an Inclined Stenosed Tapered Artery in Presence of Body Acceleration

Study of blood flow through a catheterized artery

Mathematical Modeling of Peristaltic Flow of Chyme in Small Intestine

Suspension model for blood flow through a tapering catheterized inclined artery with asymmetric stenosis

Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

Effect of Magnetic Field on Flow Behaviour of Blood through A Modelled Atherosclerotic Artery

Arterial Macrocirculatory Hemodynamics

Numerical Study of the Behaviour of Wall Shear Stress in Pulsatile Stenotic Flows

Modelling and simulation of micropolar fluid flow with variable viscosity through unhealthy artery

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Blood flow through arteries in a pathological state: A theoretical study

Simulation of Variable Viscosity and Jeffrey Fluid Model for Blood Flow Through a Tapered Artery with a Stenosis

Hydromagnetic Blood Flow through a Uniform Channel with Permeable Walls Covered by Porous Media of Finite Thickness

World Journal of Engineering Research and Technology WJERT

MHD OSCILLATORY SLIP FLOW AND HEAT TRANSFER IN A CHANNEL FILLED WITH POROUS MEDIA

Magnetic Effect on Slip Flow of Blood through Porous Medium with Time Dependent Permeability, Pulsatile Pressure and Body Acceleration

Modeling of non-newtonian Blood Flow through a Stenosed Artery Incorporating Fluid-Structure Interaction

Numerical Study of Blood Flow through Symmetry and Non- Symmetric Stenosis Artery under Various Flow Rates

Oscillatory flow of a jeffrey fluid in an elastic tube of variable cross-section

Peristaltic Pumping of a Casson Fluid in an Elastic Tube

Numerical Simulation of Sinusoidal Fluctuated Pulsatile Laminar Flow Through Stenotic Artery

Effects of Magnetic Field and Slip on a Two-Fluid Model for Couple Stress Fluid Flow through a Porous Medium

INTERNATIONAL JOURNAL OF ADVANCE RESEARCH, IJOAR.ORG ISSN

Influence of velocity slip conditions on MHD peristaltic flow of a Prandtl fluid in a non-uniform channel

Two-Layered Pulsatile Blood Flow in a Stenosed Artery with Body Acceleration and Slip at Wall

Department of Mathematics, Amrita Vishwa Vidyapeetham (University), Karnataka , India

Numerical study of blood fluid rheology in the abdominal aorta

Peristaltic Transport of a Magneto Non-Newtonian Fluid through A porous medium in a horizontal finite channel

Radiation Effect on MHD Casson Fluid Flow over a Power-Law Stretching Sheet with Chemical Reaction

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

International Journal of Mathematical Archive-7(5), 2016, Available online through ISSN

PROBLEM SET 6. SOLUTIONS April 1, 2004

Numerical modelling of shear-thinning non-newtonian flows in compliant vessels

MHD PERISTALTIC FLOW OF A COUPLE STRESS FLUIDS PERMEATED WITH SUSPENDED PARTICLES THROUGH A POROUS MEDIUM UNDER LONG WAVELENGTH APPROXIMATION

Modeling of arterial stenosis and its applications to blood diseases

Heat and Mass Transfer Effects of Peristaltic Transport of a Nano Fluid in Peripheral layer

Pressure Drop across Artificially Induced Stenoses in the Femoral Arteries of Dogs

A CFD model of hemodynamics in hemodialysis vascular access

Research Article Innovation: International Journal of Applied Research; ISSN: (Volume-2, Issue-2) ISSN: (Volume-1, Issue-1)

Effects of magnetic field and an endoscope on peristaltic motion

Peristaltic Transport of a Hyperbolic Tangent Fluid Model in an Asymmetric Channel

Peristaltic flow of a Williamson fluid in an inclined planar channel under the effect of a magnetic field

Biotransport: Principles

Numerical Study on Sinusoidal Fluctuated Pulsatile Laminar Flow Through Various Constrictions

INSTABILITY, TRANSITION AND RECEPTIVITY OF PULSATILE FLOW IN A STENOTIC TUBE

Performance Modeling and Mechanical Behaviour of Blood Vessel in the Presence of Magnetic Effects

MODELING THE FLOW OF AQUEOUS HUMOR IN POSTERIOR CHAMBER. Ram Avtar, Swati Srivastava 1

BME 419/519 Hernandez 2002

MHD peristaltic transport of a micropolar fluid in an asymmetric channel with porous medium

EFFECT OF MAGNETIC FIELD ON THE PERISTALTIC PUMPING OF A JEFFREY FLUID IN A CHANNEL WITH VARIABLE VISCOSITY

PREDICTION OF PULSATILE 3D FLOW IN ELASTIC TUBES USING STAR CCM+ CODE

Effect of the plug flow on the flow characteristics of bile through diseased cystic duct: Casson Model Analysis

Study of modified Casson s fluid model in modeled normal and stenotic capillary-tissue diffusion phenomena

Peristaltic transport of a newtonian fluid with wall properties in an asymmetric channel

PERISTALTIC FLOW OF A FRACTIONAL SECOND GRADE FLUID THROUGH A CYLINDRICAL TUBE

Numerical and Experimental Investigation of Hemodynamics of Blood Flow through Realistic Stenosis

31545 Medical Imaging systems

SYMMETRY BREAKING PHENOMENA OF PURELY VISCOUS SHEAR-THINNING FLUID FLOW IN A LOCALLY CONSTRICTED CHANNEL

PULSE WAVE PROPAGATION IN LARGE BLOOD VESSELS BASED ON FLUID-SOLID INTERACTIONS METHODS

Effects of Heat Transfer on the Peristaltic Flow of Jeffrey Fluid through a Porous Medium in a Vertical Annulus

Multiscale Hydrodynamic Phenomena

Two dimensional model of pulsatile flow of a dusty fluid through a tube with axisymmetric constriction

On the oscillatory tube flow of healthy human blood

Effect of variable viscosity on the peristaltic flow of a Jeffrey fluid in a uniform tube

Mathematical modelling of physiological flows

Numerical Analysis of MHD Flow of Fluid with One Porous Bounding Wall

Contents. Microfluidics - Jens Ducrée Physics: Laminar and Turbulent Flow 1

150A Review Session 2/13/2014 Fluid Statics. Pressure acts in all directions, normal to the surrounding surfaces

Boundary Layer Flow and Heat Transfer due to an Exponentially Shrinking Sheet with Variable Magnetic Field

Shell Balances in Fluid Mechanics

Effect on the Flow of Bile Due to Radially Varying Viscosity in the Cystic Duct

Analysis and Simulation of Blood Flow in MATLAB

ME 309 Fluid Mechanics Fall 2010 Exam 2 1A. 1B.

TWO-DIMENSIONAL SIMULATIONS OF THE EFFECT OF THE RESERVOIR REGION ON THE PRESSURE OSCILLATIONS OBSERVED IN THE STICK-SLIP INSTABILITY REGIME

Lecture 2: Hydrodynamics at milli micrometer scale

A BIVARIATE VISCOSITY FUNCTION ON THE PERISTALTIC MOTION IN AN ASYMMETRIC CHANNEL

Application Of Optimal Homotopy Asymptotic Method For Non- Newtonian Fluid Flow In A Vertical Annulus

Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

Magnetic effects on pulsatile flow of micropolar fluid through a bifurcated artery

Lab 7: Low Reynolds numbers and Tube Flows

Analytical Solutions on the Flow of blood with the Effects of Hematocrit, Slip and TPMA in a porous tube

Mathematical Model of Blood Flow in Carotid Bifurcation

TECHNISCHE UNIVERSITEIT EINDHOVEN Department of Biomedical Engineering, section Cardiovascular Biomechanics

UNIT II Real fluids. FMM / KRG / MECH / NPRCET Page 78. Laminar and turbulent flow

The Mathematical Analysis for Peristaltic Flow of Hyperbolic Tangent Fluid in a Curved Channel

Transcription:

Available at http://pvamu.edu/aam Appl. Appl. Math. ISSN: 93-9466 Vol. 8, Issue (December 3), pp. 48 494 Applications and Applied Mathematics: An International Journal (AAM) Mathematical Modelling of Blood Flow through Catheterized Artery under the Influence of Body Acceleration with Slip Velocity S. U. Siddiqui and Sapna Geeta Department of Mathematics Harcourt Butler Technological Institute Kanpur-8 Uttar Pradesh, India geeta5_hbti@rediffmail.com Received: March 3, 3; Accepted: August 8, 3 Abstract The flow of blood through stenosed catheterized artery with the effect of external body acceleration has been considered. The pulsatile flow behaviour of blood in an artery subjected to the pulsatile pressure gradient and slip velocity has been studied considering blood as a Newtonian fluid. The non-linear differential equations governing the fluid flow are solved using the perturbation method. The analytic expressions are derived for the velocity profile, flow rate, wall shear stress and effective viscosity. The computer codes are developed for the analysis of physiological parameters. The effects of various parameters on blood flow are discussed through graphs. It is observed that insertion of catheter increases the wall shear stress enormously depending upon the size of the catheter. Body acceleration enhances the axial velocity and flow rate. However it is found that with the application of slip velocity, the wall shear stress is significantly decreases. Keywords: Pulsatile flow; Body acceleration; Slip velocity; Newtonian fluid; Stenosis AMS-MSC No.: 76Z5, 74G. Introduction In recent years, the interest in hemodynamical studies has grown appreciably due to the fact that many cardiovascular diseases are closely related to the flow conditions in the blood vessels Liepsich (). The development of various fatal disorders such as Atherosclerosis, Diabetes, Thrombosis and other cardiovascular disorders, which continue to be leading cause of deaths, is increasing public concern about their treatments. Stenosis is one of them. 48

48 S. U. Siddiqui and Sapna Geeta Externally imposed body acceleration also has major influence on the flow through stenosed artery. Activities such as driving, cycling and jogging cause the human body to be exposed to accelerations. Body acceleration changes the blood velocity significantly. So the velocity of blood under the pumping action of heart is increased to the high amplitude of body acceleration. When the human body experiences a sudden velocity change, the blood flow is disturbed. The human body has a remarkable adaptability to changes and a prolonged exposure of the body to such vibrations leads to many health problems like headache, abdominal pain, venous pooling of blood in the extremities and increased pulse rate on account of disturbances in blood flow. If the response of the human system to such acceleration is understood properly, the controlled accelerations can be used for therapeutic treatments, development of new diagnostic tools and for better designing of protective pads. A model for abnormal growth in the lumen of the artery is called stenosis, which is developed due to the accumulation of cholesterol on the vessel wall is represented by Rodbard (966), Shukla (98), Sankar (9). May (963), Bugliarellow and Sevilla (97), Young (979), Chaturani (986), Sapna (9), Ponnalagasamy () have studied the flow characteristic of blood in an artery with stenosis by introducing various non-newtonian fluid models to represent the blood. Although blood is a suspension of cells it behaves like a non-newtonian fluid at low shear rates in smaller arteries. Yeleswarupu (996) has presented a generalized Newtonian model used mainly for blood, at a high rate of shear when blood behaves like a Newtonian fluid. Many researchers assumed stenosis to be symmetric and human blood to be Newtonian, to simplify the problem an assumption that remains largely valid for a large vessel as well [Ookawara (), Biswas ()]. Under normal physiological conditions transport of blood in the human circulatory system depends entirely on the pumping action of the heart producing a pressure gradient throughout the arterial system. Ishikawa () has analysed periodic blood flow through stenosed and locally expanded tubes. They found that the vortex downstream of stenosis or expansion becomes strongest at a certain frequency of pulsation. Kumar (), Haghighi () have studied the pulsatile flow of blood under the influence of externally imposed periodic body acceleration through a time dependent stenosed artery. The flow characteristic of blood through a multi stenosed artery when it is subjected to whole body acceleration has been studied by Chakravarty (999), where they considered a flexible cylindrical tube containing a homogeneous Newtonian fluid with variable viscosity depicting blood. Nagarani (8), Verma () have considered the pulsatile flow of Casson fluid through a stenosed artery with the effect of body acceleration. It is observed that the yield stress of the fluid and body acceleration highly influenced the velocity of the fluid, shear stress, flow rate in a stenosed artery. An arterial catheter is a thin, hollow, tube which is placed into the artery to measure blood pressure more accurately than is possible with a blood pressure cuff. The catheter can also be used to get repeated blood samples when it is necessary to frequently measure the levels of oxygen and/or carbon dioxide in the bloodstream. Many researchers discussed the flow of blood in an artery, in presence of a catheter by modelling the catheter and artery as rigid co-axial cylinders and blood as either Newtonian or non-newtonian fluid. During catheterization, small

AAM: Intern. J., Vol. 8, Issue (December 3) 483 tubes (catheters) are inserted into the circulatory system under x-ray guidance in order to obtain information about blood flow and pressures within the heart and to determine if there are obstructions within the blood vessels feeding the heart muscle (coronary arteries). Sarkar and Jayaraman (998) studied the pulsatile flow in a catheterized stenosed artery and estimated the correction in mean pressure drop along the stenosis due to catheterization. The effect of catheterization on various flow characteristics in a curved artery with or without stenosis was studied by Jayaraman (995) and Dash (999). Sankar (9) has studied a two-fluid model for the pulsatile flow of blood in a catheterized artery, by considering the core layer as a Casson fluid and the peripheral layer as a Newtonian fluid. To understand the existence of slip at the tube wall Nubar (967), Brunn (975) have reviewed the several treatments of slip at the walls of the capillary tubes. In view of theoretical and experimental observations implying the existence of slip at the wall, it is improper to ignore the slip in blood flow. It is also noted that in the literature, there is no direct formula to calculate the slip velocity. It is therefore worthwhile to find a formula to calculate the slip velocity at the wall. Pulsatile flow of blood through a catheterized artery in presence of different geometry of stenosis with a velocity slip at a stenotic wall has been investigated by Biswas and Chakraborty (), Verma (). It is found that the wall shear stress and effective viscosity decreases while axial velocity increases with velocity slip at wall. The aim of present analysis to study the characteristic of blood flow through a artery with axially symmetric stenosis considering blood as a Newtonian fluid. Effect of slip velocity, body acceleration and presence of catheter on the flow variables such as velocity profile wall shear stress flow rate has been studied for pulsatile blood flow in constricted artery.. Mathematical Formulation Consider a pulsatile flow of blood in the presence of an external body acceleration along with the effect of slip velocity at the stenotic wall. We consider the axially symmetric, laminar, one dimensional and fully developed flow of blood through a catheterized artery with mild stenosis. It is assumed that the wall of the tube is rigid and the body fluid blood is represented by a Newtonian fluid. The geometry of the stenosis is shown in the (Figure ) and is given by Figure. Geometry of stenosed artery

484 S. U. Siddiqui and Sapna Geeta R z R R, for z z s / cos z/ z, for z z, (), where Rz is the radius of the artery in the stenotic region, R is the constant radius of the artery in the non-stenotic region, z is the half length of the stenosis and s is the maximum height of the stenosis such that s / R. It is found that the radial velocity being very small can be neglected for low Reynolds number in case of mild stenosis. The Navier-Stokes equations governing the fluid flow is given by Schlichting and Gersten (4). u p r r F t p, r /, t z r () (3) where u represent the axial velocity along z-direction, p is the pressure, is the density, t the time, the shear stress and F t the body acceleration. Mathematically, F t is described in equation (8). Newtonian fluid (blood) can be given by the equation, u r (4) where is the shear viscosity of blood. Boundary conditions The boundary conditions are (i) u u at r R z, (5) s (ii) u at r R, (6) where u s is the slip velocity at the stenotic wall, R is the radius of the catheter. Since the pressure gradient is a function of z andt, we take

AAM: Intern. J., Vol. 8, Issue (December 3) 485 p p zt, A A coscos t, t, z (7) where A is the steady state pressure gradient, A is the amplitude of the fluctuating component, p f p, where f p is the pulse rate frequency. The periodic body acceleration t bt F t in the axial direction is given by F a cos cos, (8) where a is the amplitude of body acceleration, b fb; fb is it s frequency in Hz. The frequency of the body acceleration f b is assumed to be small so that wave effect can be neglected. By introducing the following non-dimensional variables AR u u/, z z/ R, R(z) R(z)/ R, r r/ R, t t p, b / p, 4 AR AR s s / R, us us /, /, Rp /, e A/ A, 4 B a / A, R R / R, (9) where A is steady component of pressure gradient, R is the radius of the normal artery, p is the frequency of oscillation of the pulsatile flow and then AR 4, represents the central line velocity in a poiseuille flow. The non-dimensional momentum equation () can be written as ( u ) 4 ecos t 4Bcos t / r r, t r () where R ( ), is called Womersley frequency parameter. p Equation (4) can be written as o u, r ()

486 S. U. Siddiqui and Sapna Geeta On substituting the value of in Equation () we have ecos t Bcos t r r u ( u ) 4 4 / t The boundary conditions (5) and (6) reduces to () i u u at r R z, s r r. () ( ii) u at r R. (3) The geometry of an arterial stenosis in dimensionless form is given by R z ( s cos z, for z z ), z, for z z. (4) The non-dimensional volumetric flow rate is defined by where R z Q z, t 4 r u z, r, t dr, (5), 4 Q z t Qz, t ; Qz, tis the volumetric flow rate. A R 8 Effective viscosity e defined as p 4 e ( Rz) Qz, t, z (6) can be expressed in the dimension less form as 4 e R ecos t Q z, t. (7) 3. Method of solution: Let the velocity u can be expressed in the following form

AAM: Intern. J., Vol. 8, Issue (December 3) 487,,,,,, u zrt u zrt u zrt (8) Substituting Equation (8) in Equation () & (3) respectively and equating constant term and term we get r u 4[( r e cos) t B cos t r r ], (9) u u r, t r r r () s () i u u and u at r R z, () ( ii) u and u at r R. () To determine u and u, we integrate equation (9) and () twice with respect to r, using the boundary conditions () & () u ln rr f t R r u f R R, (3) t s ln R R where f t ecost Bcost. R R Rr r R r rr r R 4 4 u D RR 4R 63R 6 ln R r ln RR R R ln RRR R R 4lnRR 4 4 4 6 3 6 ln 4lnRR, (4) where D f t. 4 Neglecting terms of o and other power of α, the expression for the axial velocity u(r, z, t) is obtained from equations (8), (3) and (4) as,, s ln rr u z r t f t R r u f t R R D C C C C, (5) 3 4 ln RR

488 S. U. Siddiqui and Sapna Geeta 4 4 where C Rr r R 4 6 3 6, R R C r ln ln r R r R, 4lnRR ln R R C R R 4 R 6 3 R 6, 4 4 RR 3 ln R R C ln R R R R R. 4 4lnRR The wall shear stress w can be obtained by substituting the velocity expression from equation (3) and (4). w u r u r, (6) rrz Rf t us f t R R RlnR R R R 3 RR R 4 RlnRRR 4ln w RR D 4 4 RR 4R 63R 6 ln R R ln ln R R R RR R R R 4lnRR. (7) From equations (5) and (5) the volumetric flow rate Q(z,t) can be obtained as Q(z, t) f t R R R R u f t R R 4 4 s ln RR R R (ln R RR R R ) D B BB3B 4, ln RR (8) 4 6 4 6 6 where B RR R RR R R ( 4) ( 4) (3 8) (5 4) (3 8), 4 4 4 B ln R R R 4 5R 6 R R 3R 6,

AAM: Intern. J., Vol. 8, Issue (December 3) 489 R R 4 4 B3 ( RR R 43R 4 (ln R RR R R )), ln RR ln RR 4 R R B ln R R 4 R 4. The expression for the effective viscosity can be obtained from equation (7) and (8). 4. Results and Discussions e In the present model our objective is to study the combined effect of body acceleration and the slip velocity in a catheterized stenosed artery assuming blood is a Newtonian fluid. The expressions for velocity, flow rate, wall shear stress and effective viscosity are obtained by solving the governing equation of flow using perturbation method with a very small Womersley frequency parameter. Computer codes are developed for numerical evaluation of the analytical results obtained in equations (5)-(9). The various parameter values are selected from Young (979), Biswas (9) and Srivastava (). It is very important to study the pattern of velocity profile since the detailed description of the flow field is given by the velocity profile. The variation of axial velocity u with radial distance r for different values of body acceleration B and for fixed values of e,, z,.,.5, u s.5 at the peak of the stenosis (z = ) is presented in figure. From the graph it is predicted that the velocity is more in the presence of body acceleration and increases rapidly with the increase of body acceleration. As the body acceleration increases the plug flow region shrivel therefore more flow takes place.

49 S. U. Siddiqui and Sapna Geeta Figure 3 shows the effects of various parameters on the axial velocity u for the different values of stenosis heights,. slip velocity usand for fixed values of R.,.5, z, t. It is observed that the magnitude of the axial velocity is more in the non-stenosed artery than that in stenosed artery. It is clearly indicated that the velocity profile is almost plugged profile for s. Slip velocity shows a significant change in velocity profile. Axial velocity increases in normal as well as stenosed vessel with the increase in slip velocity. Figure 4 depicts the variation of volumetric flow rate with pressure gradient e for different values of body acceleration parameter B and stenosis height s and for fixed values of R.,., t, u s.. It is found that as the height of the stenosis increases flow rate decreases i.e. flow rate is more in normal artery than in stenosed artery. The lowest value of flow rate Q is obtained at e =.Graph shows that the highest and lowest trends in the flow rate Q are obtained with B, u., and B, us., s.respectively. Further it is observed that the body acceleration as well as the slip velocity enhances the flow rate. Figure 5 reveals the variation of the blood flow characteristic w with catheter radius for different values of slip velocity u s in a stenosed artery. It can be easily seen that the increase of catheter radius, increases the wall shear stress. On the other hand, as the slip velocity increases the wall shear stress reduces in an artery. s s

AAM: Intern. J., Vol. 8, Issue (December 3) 49 Figure 6 shows the variation of wall shear stress with catheter radius for different values of the body acceleration parameter B and for fixed values ofs.,., us.5. It is found that the wall shear stress increases with the increase of body acceleration in an artery with inserted catheter.

49 S. U. Siddiqui and Sapna Geeta 5. Conclusion In the present mathematical model, pulsatile blood flow through stenosed catheterized artery with periodic body acceleration and axial slip velocity at the constricted wall has been considered. The variation of the flow variables with different flow parameters are presented graphically. It is seen that axial velocity and flow rate increase with the wall slip. Further it has been observed that the wall shear stress decreases with slip velocity. It can be seen that there is a great impact of both slip velocity and body acceleration on the flow variables. On the basis of the above analysis slip at the stenosed artery could play a very important role in blood-flow modeling by reducing the wall shear stress. Further this model can be used to estimate the influence of the various parameters mentioned above on different flow characteristic under severe stenosis. REFERENCES Back, L. H. (994). Estimated mean flow resistance increases during coronary artery catheterization, J. Biomech., Vol. 7, pp. 69-75. Biswas, D. and Chakraborty, U. S. (9). Pulsatile flow of blood in a constricted artery with body acceleration, Int. J. of Application and Applied Mathematics, Vol. 4, No., pp. 39-34. Biswas, D. and Chakraborty, U. S. (). A brief review on blood flow modelling in arteries, Journal of Science and Technology: Physical Sciences and Technology, Vol. 6, No. II, pp. -5.

AAM: Intern. J., Vol. 8, Issue (December 3) 493 Biswas, D. and Chakraborty, U. S. (). Pulsatile flow through a catheterized artery with an axially non symmetrical stenosis, Applied Mathematical Sciences, Vol. 4, No. 58, pp. 865-88. Brunn, P. (975). The velocity slip of polar fluids, Rheo. Acta., Vol. 4, pp. 39-54. Bugliarello, G. and Sevilla, J. (97). Velocity distribution and other characteristics of steady and pulsatile blood flow, Biorheol., Vol. 7, pp. 85-7. Chakravarty, S. and Sannigrahi, A. K. (999). A non-linear mathematical model of blood flow in a constricted artery experiencing body acceleration, Math Comput Model., Vol. 9, pp. 9-5. Chaturani, P. and Sumy, R. P. (986). Pulsatile flow of Casson s fluid through stenosed arteries with application to blood flow, Biorheology, Vol. 3, pp. 499-5. Dash, R. K., Jayaraman, G. and Mehta K. N. (999). Flow in catheterized curved artery with stenosis, J. Biomech., Vol. 3, pp. 49-6. Haghighi, A. R. and Asghari, N. (). A mathematical model for the effect of magnetic, body acceleration and time dependence on blood flow in stenosed artery, Australian Journal of Basic and Applied Sciences, Vol. 6 pp. 359-37. Haldar, K. (987). Oscillatory flow of blood in a stenosed artery, Bull. Math. Bio., Vol. 49(3), pp. 79-87. Ishikawa, T., Oshima, S. and Yamane, R. (). Vortex enhancement in blood flow through stenosed and locally expanded tubes, Fluid Dynamic Res. Vol. 6, No., pp. 35-5. Jayaraman, G. and Tiwari, K. (995). Flow in catheterized curved artery, Med. & Bio. Engg. & Compt. Vol. 33, pp. -6. Kumar, S. and Dixit, A. (). Mathematical model for the effect of body acceleration on blood flow in time dependent stenosed artery, I. J. of Stability and Fluid Mechanics, Vol., No. pp. 3-5. Liepsich, D. (). An introduction to biofluid mechanics: Basic models and application, J. Biomech., Vol. 35, pp. 45-435. May, A. G., Deweese, J. A. and Rob, C. B. (963). Hemodynamic effects of arterial stenosis, Surgery, Vol. 53, pp. 53-54. Mishra, J. C. and Chakravarty, S. (986). Flow in arteries in the presence of stenosis, J. Biomech., Vol. 9, pp. 97-98. Nagarani, P. and Sarojamma, G. (8). Effect of body acceleration on pulsatile flow of Casson fluid through a mild stenosed artery, Korea-Australia Rheology J., Vol., pp. 89-96. Nubar, Y. (967). Effects of slip on the rheology of a composite fluid: Application to blood flow, Rheology, Vol. 4, pp. 33-5. Ookawara, S. and Ogowa, K. (). Flow properties of Newtonian and non-newtonian fluid downstream of stenosis, J. Chem. Eng. Japan, Vol. 33, pp. 58-59. Ponnalagasamy, R. (). Mathematical model of pulsatile flow of non-newtonian fluid in tubes of varying cross-sections and its implications to blood flow, JFI, Vol. 349, No.5, pp. 68-698. Rodbard, S. (966). Dynamics of blood flow in stenotic vascular lesions, Am. Heart J., Vol. 7, pp. 698-74. Sankar, D. S. (9). A two fluid model for pulsatile flow in catheterized blood vessels, Int. J. of Non-Linear Mechanics Vol. 44, pp. 337-35. Sankar, D. S. and Lee, U. (9). Mathematical modelling of pulsatile flow of non-newtonian fluid in stenosed arteries, Commun Nonlinear Sci Numer Simulat., Vol. 4, pp. 97-98.

494 S. U. Siddiqui and Sapna Geeta Sapna, S. (9). Analysis of non-newtonian fluid flow in a stenosed artery, I. J. of Physical Sciences, Vol. 4(), pp. 663-67. Sarkar, A. and Jayaraman, G. (998). Correction to flow rate pressure drop relation in coronary angioplasty: steady streaming effect, J. Biomech., Vol. 3, pp 78-79. Sarojamma, G. and Ramana, B. (). Pulsatile flow of blood in a catheterized artery under external acceleration, International Journal of Advanced Engineering Technology (IJAET), Vol. III Issue IV, pp. 55-59 Schlichting, H. and Gersten, K. (4). Boundary layer theory, Springer-Verlag. Shukla, J. B., Parihar, R. S. and Rao, B. R. P. (98). Effects of stenosis on non-newtonian flow of blood in an artery, Bull. Math. Bio., Vol. 4, pp. 83-94. Srivastava, V. P., Vishnoi, R., Mishra, S. and Sinha, P. (). Blood flow through a composite stenosis in catheterized arteries, e-journal of Science and Technology, Vol. 4, Issue 5, pp. 55-64 Verma, N. K., Siddiqui, S. U. and Gupta, R. S. (). Pulsatile flow of blood in mild stenosis: Effect of body acceleration, e-journal of Science and Technology, Vol. 6, Issue 3, pp. 6-76. Yeleswarapu, K. K. (996). Evaluation of continuum models for characterizing the constitutive Behaviour of blood, Ph.D. thesis, Dept. of Mech. Engg., University of Pittsburgh. Young, D. F. (979). Fluid mechanics of arterial stenosis, J. Biomech. Eng., Trans. ASME, Vol., pp. 57-75. Young, D. F. (968). Effects of a time dependent stenosis on flow through a tube, J. Eng. Ind., Vol. 9, pp. 48-54.