TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

Similar documents
S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Trace elemental analysis of challenging samples in the mining and resource industry. Bruker Nano GmbH, Berlin, Germany April 8, 2015

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

Trace Element Analysis: Time and Cost Savings with TXRF. Bruker AXS Microanalysis GmbH Berlin, Germany

S2 PICOFOX. Innovation with Integrity. Benchtop TXRF Spectrometer TXRF

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

Shorten your Time-to-Result

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

Cost-effective Trace Element Analysis with TXRF

ICP-OES Application Note Number 35

Portable type TXRF analyzer: Ourstex 200TX

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

OES - Optical Emission Spectrometer 2000

Analysis of Soil and Sewage Sludge in the Field with a Portable ED-XRF Spectrometer

ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Overview of X-Ray Fluorescence Analysis

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Analysis Repeatability of Trace and Major Elements in a Water Sample

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Altitude influence of elemental distribution in grass from Rila mountain. Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

1 of 5 14/10/ :21

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Electron-Induced X-Ray Intensity Ratios of Pb Lα/Lβ and As Kα/Kβ by kev Applied Voltages

Course theme. Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report.

Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report. Course theme

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

Three hour lab. Chem : Sept Experiment 2 Session 2. Preparation Pre-lab prep and reading for E2, Parts 3-5

Prof. Dr. Biljana Škrbić, Jelena Živančev

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Analysis of domestic sludge using the Agilent 4200 MP-AES

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Geogenic versus Anthropogenic Metals and Metalloids

A MODIFIED APPROACH TO HOMOGENEITY TESTING AT MICROSCALE

Application of the GD-Profiler 2 to the PV domain

Quantitative XRF Analysis. algorithms and their practical use

QUANTIFICATION OF MERCURY, LEAD, AND CADMIUM IN AQUEOUS SOLUTIONS BY ENERGY K X-RAY FLUORESCENCE SPECTROSCOPY

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Element Cube Project (x2)

Micro-XRF excitation in an SEM

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner, Johann Wernisch, and Michael Mantler

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

4.1 Atomic structure and the periodic table. GCSE Chemistry

RAPID AND LOW-COST DETERMINATION OF HEAVY METALS IN SOIL USING AN X-RAY PORTABLE INSTRUMENT

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

This document is a preview generated by EVS

AN IMPROVED AEROSOL GENERATION SYSTEM FOR THE PREPARATION OF XRF CALIBRATION FILTERS

Three hour lab. Chem : Feb Experiment 2 Session 2. Experiment 2 Session 2 Electrons and Solution Color

Issues With TXRF Angle Scans and Calibration

High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source

BRAGG AND BARKLA POLARIZATION IN EDXRF

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

X-Ray Fluorescence and Natural History

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

Validation)of)a)horizontal)method) for)trace)elements)in)soil,) sludge)and)biowaste)

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Samples compliant with the WATER

AMMS-100 Atmospheric Metal Monitoring System

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

ATOMIC SPECROSCOPY (AS)

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

XUV 773: X-Ray Fluorescence Analysis of Gemstones

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13. Determination of Major, Minor and Trace Elements in a Clay Sample

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Trace Metal Dynamic Extraction from Five Pumps in Hydrochloric Acid. Submitted to: Reto Schoeb Levitronix GmbH. Submitted by:

IAEA-TECDOC-9SO. Sampling, storage

Transcription:

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 236 ABSTRACT TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Hagen Stosnach Röntec GmbH, Berlin, Germany Total Reflection X-Ray Fluorescence Analysis (TXRF) is an established technique for trace element analysis in various sample types. Restricted in the past to expensive large-scale systems, in this study the capability of a benchtop system for trace element analysis is reported. By analysing various heavy metals in raw and digested sewage as well as mercury in recycling glass, the suitability of the TXRF system for these kinds of applications could be proven. Based on this data, the benefits, disadvantages, and restrictions of the benchtop system in comparison to other trace element techniques like ICP-OES and AAS are evaluated. INTRODUCTION TXRF has been used for trace element analysis in various fields of application like wafer surface analysis [1,2], organic and inorganic chemistry [3] as well as environmental and aerosol analysis [4,5]. Many additional application fields for TXRF are reported [6,7]. The benefits of this analytical technique are, that it is non-destructive, requires only extremely minute sample amounts, and the analysis, including sample preparation and quantification, is easy to handle. In the past TXRF analysis was restricted to large scaled instruments, which demand the usage of cooling water and liquid nitrogen. In this study a benchtop spectrometer has been used. It is ensured, that with this instrument, similar sensitivities compared to laboratory systems can be achieved even when used for on-site field investigations [8]. To test the capability of this instrument for different types of trace element analysis two different applications have been investigated: analysis of several trace elements in raw and digested sewages, and the determination of mercury in recycling glass. INSTRUMENTATION For all investigations a benchtop TXRF spectrometer (PicoTAX, Röentec, Berlin, Germany) was used. The X-Ray source used in this instrument is an air-cooled low power metal ceramic tube with a Mo anode, operating at 50 kev and 1.0 ma. The Monochromator is a Ni/C multilayer. This excitation allows the determination of the elements from Al to Y (K series) and Pd to U (L series). The detector used in this instrument is a Peltier cooled drift chamber. A summary of the technical specifications of the PicoTAX spectrometer can be found in Table 1.

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 237 X-Ray tube Element range Optics Detector Carrier Sample station Control Size, weight Power consumption Table 1. Technical specifications of the TXRF spectrometer PicoTAX. 50 kv, 1 ma, Mo target Al to Y, Pd to U Multilayer Ni/C, 17.5 kev, 80 % reflectivity Drift chamber, 10 mm 2, <160 ev resolution Quartz or other materials, 30 mm diameter Type 1: Single disc changer Type 2: Sample station with cassette for 25 discs PC, data transfer via serial interface 600 x 300 x 450 mm, 37 kg 150 W SEWAGE ANALYSIS For the analysis of sewages, three different samples have been analysed: a control solution, a raw untreated sewage, and the same sample after aqua regia digestion. The control solution has been prepared by adding different elements from mono element standard solutions to ultrapure water. Digestion of the raw sewage has been done by applying microwave heating to a 1:4 mixture of sewage and aqua regia and subsequently filtration. For comparison purposes the digested sewage sample was analysed by means of ICP-OES. This was not possible for the raw sewage due to its high content of colloidal matter. The aim of the sewage analyses was to assess the possibilities for trace element determination in sewages according to legal regulations. The threshold values regarded in this study are listed in Table 2. With this it was of great importance to test, if a threshold screening of the raw sewage is possible. Table 2. Treshold values for sewage samples. Element Treshold value (mg/l) As 0.1 Pb 0.5 Cd 0.1 Cr (complete) 2.0 Co 0.5 Cu 1.0 Mo 1.0 Ni 2.0 Zn 2.0 Quantification of TXRF measurements is generally based on internal standardization [7]. Analyzing liquid samples, a standard solution containing a defined quantity of an element not present in the sample is added. For the sewage samples internal standardization was made by adding 5 µl of internal standard solution (Merck Ga solution, 1 g/l) to 1 ml of undiluted sample solution. To test the influence of the colloidal matter in the raw sewage an additional sample was prepared by diluting 0.5 ml of sample solution with 0.5 ml of ultrapure water. After the addition of the internal standard all solutions were homogenized thoroughly. Sample preparation for TXRF analysis demands the sample to be prepared as a thin layer on a reflective media [7]. For the sewage samples this was done by transferring an aliquot of 10 µl sample solution onto a quartz glass carrier using a pipette. Thereafter these specimens were dried

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 238 in a desiccator. All samples have been prepared as a triplicate and analysed using a measurement livetime of 1000 seconds. The results of the sewage analysis are presented in Figure 1 to Figure 4, and the associated data is given in Table 3. Comparing the TXRF results with the nominal values of the control solution shows a good correlation for the elements K, Ca, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ba, and Bi (Figure 1). Distinct deviations can be observed for Tl, Pb, and As. The underestimation of Tl is caused by a line overlap of the Tl Lα by the Ga Kβ line. In this study the element Tl was not of great interest. For an accurate determination, the usage of another element for internal standardisation could solve this problem. A line overlap between the Pb Lα and the As Kβ line is the most probable reason the wrong values of these elements. In addition As was present in a concentration close to the detection limit. Several elements could not be analysed by means of TXRF. Low energy elements like Na and Mg are in general not detectable with the used instrument because their fluorescence signals are absorbed before detection. Using a Mo tube for excitation causes, that the elements Cd, Sn, and Sb can only be analysed by means of their L lines. In the given concentration ranges these elements could not be detected because of the low energy of their L lines and line overlaps with the K lines of the matrix elements, especially Cl and Ca. Figure 1. Comparison of the nominal and the measured values of the control solution. The front graph shows the data in the low concentrations range (0.01 10 mg/l), the graph in the back indicates the data of matrix elements (concentration range 10 - >1000 mg/l). Evaluating the measurement results for the digested sewage (Figure 2) good correlations can be seen with ICP-OES values for all elements but P, S, and K, which are distinctly underestimated. The most probable reason for this is that because of the high matrix concentration, no ideal thin layer sample could be prepared. This causes absorption effects, which of course have the largest

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 239 effect on low energy elements. For several elements, simultaneously analysed by TXRF, no ICP- OES values are available. This is because some of these cannot be analysed by common ICP- OES systems (Cl and Br), or have not been included in the ICP measurement program and calibration. Figure 2. Comparison of ICP-OES and TXRF results for digested sewage. The front graph shows the data in the low concentrations range (0.01 10 mg/l), the graph in the back indicates the data of matrix elements (concentration range 100 - >1000 mg/l). The influence of matrix elements, intensified by the presence of colloidal particles, is visible when comparing the digested sewage ICP results with those derived by means of TXRF measurements of the raw sewage (Figure 3). Especially because of the high particle content of raw sewage, the result of the preparation was no ideal thin layer sample, and thus absorption and scattering effects lead to a light underestimation of most elements. The comparison of the Hg values is not possible because this element is not analysable using common ICP-OES spectrometers and thus the value given in Table 3 is not reliable.

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 240 Figure 3. Comparison of ICP (digested sewage) and TXRF values (raw sewage). The front graph shows the data in the low concentrations range (0.01 10 mg/l), the graph in the back indicates the data of matrix elements (concentration range 100 - >1000 mg/l). In Figure 4 the ICP values of the digested sewage are compared to those of the TXRF values measuring the raw sewage diluted 1:1 with ultrapure water. It is obvious, that by this dilution the effects of matrix components and colloidal matter are reduced. For all except the light elements P, K, and S good concordance of the ICP and TXRF values can be observed. Figure 4. Comparison of ICP (digested sewage) and TXRF (diluted raw sewage) values. The front graph shows the data in the low concentrations range (0.01 10 mg/l), the graph in the back indicates the data of matrix elements (concentration range 100 - >1000 mg/l).

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 241 The results of the sewage analyses lead to the conclusion, that TXRF is in general a suitable method for this kind of application. In the analysed control solution all measured elements have been present in concentrations distinctly below the threshold values given in Table 1. Compared with ICP-OES analysis several benefits can be named. First, the sewage can be analysed without the need for digestion. Analysing the sewage without any further treatment, except for the addition of the internal standard, is possible for a semiquantitative element screening. By diluting the sample material, accurate results for most elements measurable can be achieved. To perform the analysis without digestion even allows a more accurate analysis of Hg, which is otherwise at least in parts lost during digestion. In addition TXRF is a simultaneous multi-element method and works without the need for external calibration routines. Disadvantages of this method are the comparably long measurement times and the element restrictions. Two of the elements listed in Table 1 could not be detected. Mo was not analysed because a Mo-tube was used. Cd can be detected with the used instrument just by means of the low-intensity L-lines, which are overlapped by the K-lines of the matrix elements, especially Ca and Cl.

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 242 Table 3. Results of the control solution and sewage analysis using ICP-OES and TXRF. All concentrations are given in mg/l. Control solution Digested sewage Raw sewage (undiluted) Raw sewage (diluted) Element Nominal value TXRF ICP-OES TXRF TXRF TXRF Na 10 < LLD not analysed < LLD < LLD < LLD Mg 2.5 < LLD not analysed < LLD < LLD < LLD Al 5 < LLD P 25 17 440 202 103 252 S 60.2 35 3720 1515 1328 1719 Cl 212 not analysed 28 821 1110 K 10 10.6 668 207 174 231 Ca 500 541 361 394 167 384 Ti not analysed 5.72 10.70 V not analysed 0.24 Cr 0.5 0.49 3.00 2.95 1.77 2.92 Mn 1 0.98 3.76 3.72 1.96 3.29 Fe 5 5.1 6.07 6.09 2.96 4.70 Co 0.125 0.101 not analysed 0.08 0.05 Ni 0.50 0.55 1.69 1.70 1.85 1.83 Cu 0.25 0.26 1.98 1.76 1.17 1.24 Zn 0.5 0.56 4.20 4.32 2.53 3.11 As 0.025 0.017 Se 0,1 0.07 not analysed 0.03 Br not analysed 1.79 6.89 8.43 Sr not analysed 0.53 0.36 0.58 Mo 0.25 Ag 0.025 < LLD Cd 0.025 < LLD Sn 0.5 < LLD Sb 0.1 < LLD Cs not analysed 2.01 Ba 0.25 0.27 not analysed 0.44 2.36 0.15 Hg 0.025 < LLD 0.02 0.013 0.12 Tl 0.1 0.04 Pb 0.125 0.19 0.74 0.78 0.55 0.57 Bi 0.1 0.12

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 243 ANALYSIS OF MERCURY IN RECYCLING GLASS The usage of mercury is essential in several industrial branches, such as the lighting industry, although it is known as a hazardous element. With regard to recycling and production processes the accurate control of this element is of crucial importance. Due to the high volatility at room temperature, the trace analysis of mercury is complicated [10]. For glass samples an expensive sample preparation process is demanded for the analysis by means of Cold Vapour Atomic Adsorption Spectroscopy [11]. For this study a pulverous round robin glass sample has been studied by TXRF analysis. To determine, which internal standard can be used, a qualitative analysis of the sample has been performed. For this purpose a small quantity of the glass powder has been transferred to a quartz glass carrier with a Q-tip. The measurement time was set to 1000 seconds. In the resulting spectra (Figure 5) a distinct mercury signal could be detected, and because of the absence of other elements in the energy region of 11.0 11.5 kev, Se has been chosen as the element for internal standardisation. Figure 5. Spectra of the glass sample prepared as a loose powder on a quartz glass disc. For quantitative analysis the sample material has been prepared as a suspension. 800 mg of the glass powder were mixed with 10 ml of a 1% Triton X100 solution. Triton X100 is an alkyl aryl polyether alcohol and serves as a tenside. Using Triton X100 for the preparation of suspensions improves the homogeneity of the resulting specimen. After addition of 10 µl Se standard solution (1 g/l) the suspension has been thoroughly homogenized. 5 µl of this suspension have been transferred onto a quartz glass sample and dried in a desiccator. Two homogenized suspensions were measured in triplicate for 1000 seconds.

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 244 The mercury content of the glass sample was certified by external laboratories using the ICG/TC2 method (data to be published). The element content of the glass, including additional elements analysed simultaneously, estimated by TXRF analysis is shown in Table 4. Additionally the low limit of detection was calculated for mercury using a measurement time of 1000 seconds to a value of 0.20 mg, using Equation (1) [7]. c LLD = 3 ( 2 N back ) (1) N net c: Concentration of element N net : Netto countrate N back : Background countrate Table 4. Quantitative results for the glass sample obtained by TXRF spectroscopy. Element Ca Ti Cr Mn Fe Ni Cu Zn Line K K K K K K K K Conc. [mg/kg] 8841 66.8 4.0 8.7 281 0.5 2.6 2.3 S (n = 6) [mg/kg] 1350 9.5 1.1 2.2 76 0.2 0.8 0.4 LLD [mg/kg] 7.2 1.6 0.66 0.54 0.58 0.26 0.22 0.18 Element Ga As Rb Sr Y Ba Hg Pb Line K K K K K L L L Conc. [mg/kg] 0.8 4.7 14.4 50.1 16.2 930 2.2 12.6 S (n = 6) [mg/kg] 0.6 2.9 4.6 14.6 4.6 198 0.3 3.5 LLD [mg/kg] 0.15 0.14 0.24 0.28 0.43 3.1 0.20 0.22 The comparison of the TXRF and the CV-AAS values in Table 5 show a very good concordance of the analysed mercury contents. Thus it can be concluded, that the TXRF is a suitable technique for the analysis of mercury in recycling glass. Compared with the CV-AAS technique, the major benefits of TXRF are the easy and fast sample preparation without the need for digesting the sample material, the lack of need for an external calibration, and because it is a simultaneous multi-element method. In addition, the risk of falsified results caused by memory effects, as described by the ICG/TC2, can be completely avoided. A disadvantage of the TXRF technique is the comparably long measurement time. But if the complete analysis including sample preparation and pre-treatment is taken into account, this factor is almost negligible. Table 5. Comparison of TXRF and CV-AAS values for the mercury content. Method Analysis Hg [mg/kg] Standard deviation [mg/kg] 1 2.8 0.3 (n = 10) 2 2.9 0.3 (n = 7) CV-AAS 3 2.13 4 2.19 5 2.42 0.12 6 2.5 0.07 (n = 6) TXRF PicoTAX 2.2 0.3 (n = 6)

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 245 SUMMARY This study has proven that TXRF using a benchtop system is suitable for trace metal analysis in various sample types like raw and digested sewage as well as mercury determination in glass samples. Compared to other trace element techniques like ICP-OES and AAS the following benefits can be named: The easy calibration routine by just using internal standardisation, a relatively easy sample preparation, the lack of needing external media like cooling water or liquid nitrogen, the possibility of simultaneous multi-element analysis, and the complete avoidance of memory effects. A general disadvantage of TXRF is the comparably long measurement time, which however must be evaluated together with the effort for sample preparation. In addition the instrument used in this study has some restrictions with regard to the detectable element range (tube-line elements, low-z elements and elements just detectable by their L-lines). OUTLOOK The results of this study show that the used benchtop spectrometer has a strong capability for trace element analysis in various sample types. Further investigations of additional sample types will be performed in the future. One main focus will be the mobile usage of the system for onsite analysis, such as that of contaminated soil areas. For an improvement of the analytical capacity the implementation of a W-excitation source as well as of a He-purge system is planned. ACKNOWLEDGEMENTS The author would like to thank the following institutions for their support: Alab AG, Urdorf/Switzerland Germany Society of Glass Technology REFERENCES [1] Fabry, L. et al., Surface and Interface Analysis Vol. 24, 1996, 8, 511-516. [2] Streli, C. et al., X-Ray Spectrometry, 2001, 20, 24-29. [3] Exner, A. et al., Fresenius J. Anal. Chem., 2000, 366, 254-259. [4] Mages, M. et al., Adv. X-Ray Anal., 2002, 544-553. [5] Schmeling, H., Spectrochim. Acta, 2001, B56, 2127-2136. [6] Potts, J.P. et al., J. Analy. At. Spectrom., 2001, 16, 1217-1237. [7] Klockenkämper, R., Total Reflection X-Ray Analysis, John Wiley & Sons, 1997, 245. [8] Mages, M. et al., Spectrochim. Acta, 2003, B58, 2129-2138. [9] Water pollution control regulation, SR 814 201, Appendix 3.2., 18.12.2001 [10] Flanagan, F.J. et al., Geostandard Newsletter, 1982, 6, 25-46. [11] CV-AAS, Norm 2/99-1194, International Commission on Glass ICG/TC2