Mechanisms of retention in HPLC

Similar documents
Analysis - HPLC A.136. Primesep 5 µm columns B.136

Liquid Chromatography

Mechanisms of retention in HPLC

Mechanisms of retention in HPLC

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Comparison of different aqueous mobile phase HPLC techniques

Protein separation and characterization

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah

The Theory of HPLC. Ion Pair Chromatography

1. Ion exchange chromatography

Chromatography. Gas Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

HILIC Method Development in a Few Simple Steps

Introduction to Chromatography

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Acclaim Mixed-Mode WCX-1

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

penta-hilic UHPLC COLUMNS

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Cation Exchange HPLC Columns

Glyphosate in all its forms

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Fast Separation of Vastly Different Compounds by Isocratic HPLC

penta-hilic UHPLC COLUMNS

Liquid Chromatography

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Analytical Chemistry

Chapter 17: Additional Aspects of Aqueous equilibria. Common-ion effect

Determination of trace anions in concentrated hydrofluoric acid

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

High Performance Liquid Chromatography

It s hot! ZIC -chilic

Principles of Gas- Chromatography (GC)

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Chapter 16. Solubility and Complex Ion Equilibria

HPLC Background Chem 250 F 2008 Page 1 of 24

Lecture Presentation. Chapter 16. Aqueous Ionic Equilibrium. Sherril Soman Grand Valley State University Pearson Education, Inc.

Shodex TM ODP2 HP series columns

Reversed Phase Solvents

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Hints for Strong Ion Exchange Resins

Packings for HPLC. Packings for HPLC

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

CHAPTER 6 SUMMARY & CONCLUSION. pollution. It was known that many analytical methods that are available for the

Chromatographic Analysis

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Formation of a salt (ionic compound): Neutralization reaction. molecular. Full ionic. Eliminate spect ions to yield net ionic

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

High Performance Liquid Chromatography

for Acclaim Mixed-Mode HILIC-1 Column

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Chapter 17. Additional Aspects of Equilibrium

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

for Acclaim Mixed-Mode WCX-1

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

AP Chemistry. CHAPTER 17- Buffers and Ksp 17.1 The Common Ion Effect Buffered Solutions. Composition and Action of Buffered Solutions

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

The Theory of HPLC. Normal Phase (Absorption) Chromatography

Chapter 23 Introduction to Analytical Separations

Too Polar for Reversed Phase What Do You Do?

April 23, 2015 Lab 1 - Gravimetric Analysis of a Metal Carbonate

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Acid Base Equilibria

ION CHROMATOGRAPHY SYSTEM S 150

8. Methods in Developing Mobile Phase Condition for C18 Column

1. Know and be capable of applying the Bronsted-Lowery model of acids and bases (inculdig the concepts related to conjugate acid-base pairs.

Acid-Base Equilibria and Solubility Equilibria

NANYANG TECHNOLOGICAL UNIVERSITY ENTRANCE EXAMINATION SYLLABUS FOR INTERNATIONAL STUDENTS CHEMISTRY

Chem 321 Name Answer Key D. Miller

C190-E105 Printed in Japan ATD

Try this one Calculate the ph of a solution containing M nitrous acid (Ka = 4.5 E -4) and 0.10 M potassium nitrite.

Dionex IonPac AS28-Fast-4µm column

ProPac WCX-10 Columns

AP* Chapter 16. Solubility and Complex Ion Equilibria

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Technical Guide Thermo Scientific Syncronis HPLC Columns

C18 Column. Care & Use Sheet

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

ISO INTERNATIONAL STANDARD

Other types of liquid chromatography

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Ion Chromatography (IC)

Introduction to Pharmaceutical Chemical Analysis

Chem 222 #20 Ch 23, Ch26, Ch11 Mar 29, 2005

Chapter 16. Acid-Base Equilibria

Kang, Lin-Woo, Ph.D. Professor Department of Biological Sciences Konkuk University Seoul, Korea nd Semester

Evolution of Mixed-Mode

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Module 4: "Surface Thermodynamics" Lecture 22: "" The Lecture Contains: Examples on Effect of surfactant on interfacial tension. Objectives_template

Chapter content. Reference

Chiral Flash Columns

Transcription:

Mechanisms of retention in HPLC María Celia García-Álvarez-Coque Department of Analytical Chemistry University of Valencia Valencia, Spain https://sites.google.com/site/fuschrom/ 1 Part 3

Mechanisms of retention in HPLC Index 1. Retention in reversed-phase, normal-phase and HILIC 2. Secondary equilibria in reversed-phase liquid chromatography: Part A 3. Secondary equilibria in reversed-phase liquid chromatography: Part B 4. Retention modelling (quantification or prediction): Part A 5. Retention modelling (quantification or prediction): Part B 6. Gradient elution 7. Peak profile and peak purity 8. Computer simulation 2

3.1. Acid-base equilibria 3.1.1. Changes in retention with ph 3.1.2. Buffers and measurement of ph 3.2. Metal complexation 3.2.1. Determination of metal ions 3.2.2. Determination of organic compounds 3.3. Recommended literature 3

3.1. Acid-base equilibria 3.1.1. Changes in retention with ph Sigmoidal dependence of RPLC retention versus mobile phase ph for weak acids and bases: pronounced drop around ph = pk a in the direction of the ionic species k k A kha K h 1 K h K = K a 1 : apparent protonation constant ph : log [H + ] pk a = log K pk a = log K HA B Retention factor A Retention factor BH + 4 ph ph

Neutral weak acids lose a proton and become ionised when the ph increases HA A + H + HA pk a A 0 14 7 ph Aminic bases accept a proton when ph decreases HB + B + H + HB + pk a 0 14 7 B ph For polyprotic compounds, the k-ph curve depends on the charge of the different acid-base species H 2 A + HA + H + H 2 A + pk a1 HA pk a2 A ph HA A + H + 0 14 7 5

pk a1 = 2.5 pk a2 = 9 log k ph 6 H 2 A + HA +/ - + H + HA +/ - A - + H + P app P / P 1 [H K [H K a1 ] a1 ] P K [H a2 ] K [H a2 ]

Retention drops The drop height depends on the difference in polarity between the acid-base species. Small variations in the mobile phase ph at values close to the pk a result in significant changes in retention and selectivity. Therefore, the ph in this region needs to be tightly controlled to achieve robust procedures. pk a pk a HA B Retention factor Retention factor A - BH + 7 ph ph

Acidic ph Robust methods are achieved in regions scarcely affected by changes in ph. Weak acids: region of predominance of the neutral species (acidic ph) (ion suppression chromatography) Basic compounds: acidic ph is also used to protonate (deactivate) silanols on the stationary phase. HA Retention factor A - ph 8 Separations at very low ph are not always feasible, due to column instability and long analysis times for some solutes.

Addition of IIC reagents The pk a value is shifted and the curve trend may be changed by interaction of the ionic species of the acid-base pair with an adsorbed ion on the stationary phase, which depends on the charge of both ions. A - B Cationic additive Retention factor HA pk a Retention factor BH + pk a R + R + R + HA BH + Anionic additive Retention factor pk a A - Retention factor pk a B A A A 9 ph ph

3.1.2. Buffers and measurement of ph The ph range for conventional columns in RPLC is 2.5/3.5-7.0/7.5, but for some special columns, it can be extended to 2-12. For ionisable compounds, the addition of an appropriate buffer is needed to fix the ph and achieve reproducible retention. Common buffers correspond to the acid-base systems: tris(hydroxymethyl)aminomethane (Tris) phosphoric citric phthalic acetic formic ammonium The buffering capacity occurs in the range pk a ph = pk a,buffer ± 1 Only volatile buffers are compatible with ELS and MS detection. Care should be taken with buffers that facilitate algae formation!!! Retention factor HA 1 A - 10 ph

The ph should be measured in the hydro-organic mixture, better than in the aqueous buffer. Common operational methodology in RPLC is measurement of ph in water before the addition of the organic solvent. Of course, the reference buffers are also prepared in water ( scale). This procedure has the advantage of reducing the number of measurements, since the ph value will be the same for all mobile phases prepared with the same buffered solution, independently of the amount of organic modifier. ph w w However, it does not take into account the influence of the organic modifier on ph. Predictions can differ strongly from the expectancies!!! w w ph 11

The ph should be measured in the hydro-organic mixture, better than in the aqueous buffer!!! The electrode system ideally should be calibrated with standard buffers prepared using the same solvent composition as the mobile phase, which gives rise to the so-called scale. These standards are not usually commercially available and need careful maintenance. A solution is to measure the ph in the hydro-organic mixture and calibrate the electrode system with aqueous buffers, giving rise to the scale. Fortunately, both scales can be easily converted to each other. s sph s wph s wph ph s s 12

ph correction s s ph s w ph ( ) (3.1) δ : correcting term depends on the solvent nature and concentration Example: For 0 60% acetonitrile and ph 3 7 ( ) 0.348 2.796 2 4 (3.2) Transfer of log K values between both scales is similar: log s s K log s w K ( ) (3.3) The column temperature should be controlled, since it affects strongly the ionisation degree of analytes and buffers. The ionic strength of the reference buffers and mobile phases should agree to avoid changes in liquid junction potentials. 13

3.1. Acid-base equilibria 3.1.1. Changes in retention with ph 3.1.2. Buffers and measurement of ph 3.2. Metal complexation 3.2.1. Determination of metal ions 3.2.2. Determination of organic compounds 3.3. Recommended literature 14

3.2. Metal complexation 3.2.1. Determination of metal ions RPLC is a good alternative to spectroscopic methods and ion exchange chromatography for metal analysis. It allows the simultaneous determination of several metals, interference removal, coupling with different detectors, and high sensitivity. Cu 2+ R Zn 2+ Alternatives M 2+ + L n ML 2 n The direct IIC separation of transition-metal ions is difficult, since the behaviour of hydrated metal ions is not different enough. The required selectivity should be achieved using a number of side-reactions: complexation 15 ion-pairing in addition to acid-base equilibria!!! dynamic ion exchange association with a micelle in the mobile phase R Zn 2+

The separation of chelates using metallochromic ligands with highly absorbing chromophores avoids the need of post-column derivatisation, with sub-μg/ml-level detection limits. Higher selectivity and sensitivity can be achieved with fluorimetric complexing reagents. Neutral complexes Anionic complexes Hydro-organic mixtures without additives IIC mode with alkylammonium salts with or without a competing anion in the mobile phase IIC mode with cationic surfactants as cetyltrimethylammonium bromide or cetylpyridinium chloride below or above the CMC Binary complexes are usually formed, with a few examples of ternary complexes that enhance the selectivity and sensitivity. Chelating reagents used in spectrophotometric methods: 8-hydroxyquinoline 4-(2-pyridylazo)-resorcinol (PAR) 1,10-phenanthroline - O N O Mg 2+ - N dithiocarbamates azo dyes, etc. 16

Side reactions In some cases, selectivity is improved by adding a second ligand to mask the metallic interferences (eliminate the corresponding peak). The integrity of metal chelates is susceptible to ph, since side reactions are expected at low ph with the ligands (protonation) and at high ph with metal ions (hydroxylation). MLL + MLL 2 + MLL 3 +... LL HL 1 n + H 2 L n H + at low ph M 2+ + L n ML 2 n OH at high ph M(OH) + + M(OH) 2 + M(OH) 3 + 17 Poor water solubility of some chelates requires a mobile phase with a high proportion of organic solvent or a surfactant!!!

Effect of ph log K ML Masking reagent log K ML Ligand protonation Metal ion hydroxilation ph The narrow ph range of conventional columns may be unsuitable for complex formation. 18

3.2.2. Off-line and on-line modes There are two main operational modes in metal complexation RPLC: Off-line (pre-column) formation of the complexes with subsequent separation, and online formation with a ligand added to the mobile phase. Injection of complexes Injection of free metals Off-line On-line Ligand added to the mobile phase Heating may be needed to speed up complexation!!! 19

Derivatisation reactions These operational modes are also used in the analysis of organic compounds by derivatisation reactions to modify their retention and allow detection. O R' S R N H R' S H H + + H H N R O Amino acid Thiol o-phthalaldehyde (OPA) Isoindole Analysis of amino acids by isoindole formation 20

Off-line approach: excess reagent Chelates can be completely separated from the excess of reagent added at the off-line chelation step. This allows detecting only the chelate signals with no background. reagent peak Injection of complexes plus reagent Absorbance, mua 2 1 0 M I M II M III 0 10 20 30 40 Time, min 21

Off-line approach: complex stability Only thermodynamically or kinetically stable chelates will reach the detector cell, since each chelate migrates completely apart from the ligand resulting in a very steep decrease in ligand concentration in the nearby of the chelate band. ML + L Weak complexes will dissociate in the analytical column, through solvolysis or ligand-exchange reactions. Slow formation of the complexes is not necessarily detrimental for the analysis. The column can work not only as a conventional separation device, but also as a powerful kinetic discriminator for chelates: kinetic differentiation chromatography The synergic interactions of four origins of unique selectivity are combined: pre-column chelation chromatographic separation dissociation kinetics spectral selectivity ML L 22

On-line approach: Dynamic chelating chromatography L Cu 2+ R Zn 2+ The simplest operational mode: free metal ions are injected and complexed inside the column. Combination of complexation and ion exchange Injection of free metals reactions: the strengths and rates of the reactions of the metal with the ligand and the IIC counterion added to the mobile phase give rise to Ligand or ligand/iic reagent added to the mobile phase the observed selectivity. 23

The selectivity and sensitivity of the analysis in the off-line mode can be enhanced by combining off-line complexation with solvent extraction. However, many chelates used to determine metal ions by spectrophotometry using solvent extraction are not sufficiently strong, and dissociate in the RPLC column. 24

Combination of off-line and on-line modes A strong chelating reagent can be idoneous for extraction of the metal ions in a sample, but not at all for an RPLC separation, due to: lack of selectivity instability of the complexes at the column experimental conditions Injection of complexes undetectability A solution is the combination of the off- and on-line modes. Ligand added to the mobile phase The first ligand (used in the extraction step) can be also replaced with another added to the mobile phase in the so-called ligand-exchange approach. 25

Coating the stationary phase with a ligand Hydrophobic metallochromic ligands, such as xylenol orange or methyl thymol blue, have been used to coat the RPLC stationary phase, producing a chelating capacity to separate metal ions. Two approaches are possible: pre-coating the stationary phase with the ligand and elution with an inorganic salt addition of the ligand within the mobile phase (dynamic coating of the stationary phase) Precoating with ligand Dynamically coating of the stationary phase allows: larger column capacity and stability improved separation efficiency and selectivity ability to exploit the ligand in the mobile phase for metal detection 26

3.2.3. Determination of organic compounds by complexation Metal cations can be also used to modulate the selectivity in the separation of organic compounds able to form complexes (that act as ligands). There are two basic approaches: introduction of the metal ions into the mobile phase introduction of the metal ions into the stationary phase Metal added to the mobile phase Precoating with metal 27

When metals ions are added as salts of non-complexing anions, such as nitrate or perchlorate, the mobile phase should be acidic to avoid metal hydrolysis. In this case, column performance is often poor in terms of selectivity and peak profile. M n+ + H 2 O M(OH) n-1 M(OH) n The use of charged metal chelates (anionic or cationic) is a more versatile and simple approach, with enhanced performance against the use of conventional IIC reagents. 28

When metal complexes are used, two mechanisms are possible: ligand-exchange between the analysed organic compound and the ligands in the complexes formation of ternary complexes (metal-ligand-organic compound) Both mechanisms involve: hydrophobic selectivity steric selectivity, related to the conformationally rigid structures of the chelates, which serve as templates. ML + X MX + L ML + X MXL 29

The metal choice is a compromise between several factors: ability to form complexes with the analysed organic compound solubility of the complex in the hydro-organic mixture detection of the complex Most common metals: Cu 2+, Ni 2+, Zn 2+, Ag + Silver ion (argentation chromatography) is used in a common method for the analysis of lipids. Incorporation of Ag + into the solid support is preferred, since the addition of Ag + in the mobile phase has the disadvantage of using a mobile phase troublesome to handle and is quite more expensive. 30