Experiment 4: Equilibrium Thermodynamics of a Keto-Enol Tautomerism Reaction

Similar documents
EXPERIMENT 8. NMR STUDY OF A KETO-ENOL EQUILIBRIUM CONSTANT

NMR Data workup using NUTS

Login -the operator screen should be in view when you first sit down at the spectrometer console:

Dr. White Chem 1B Saddleback College 1. Experiment 15 Thermodynamics of the Solution Process

Chemistry Department

NMR PRAKTIKUM. Data processing Data acquisition... 17

Operation of the Bruker 400 JB Stothers NMR Facility Department of Chemistry Western University

Carbon and Heteronuclear NMR on the Bruker

LAB 2 - ONE DIMENSIONAL MOTION

North Carolina State University Department of Chemistry Varian NMR Training Manual

Calculating Bond Enthalpies of the Hydrides

1H 1D-NOE Difference Spectra and Spin-Saturation Transfer Experiments on the GN500

Physical Chemistry II Laboratory

MEASUREMENT OF THE CHARGE TO MASS RATIO (e/m e ) OF AN ELECTRON

Laboration 8a. Relaxation, T 1 -measurement with inversion recovery

Mnova Software for Analyzing Reaction Monitoring NMR Spectra

BCMB/CHEM 8190 Lab Exercise Using Maple for NMR Data Processing and Pulse Sequence Design March 2012

Determining C-H Connectivity: ghmqc and ghmbc (VnmrJ-2.2D Version: For use with the new Software)

Agilent s new solution for obtaining routinely quantitative results from NMR measurements. Magnetic Resonance Systems

Physical Chemistry Final Take Home Fall 2003

Chemical Kinetics I: The Dry Lab. Up until this point in our study of physical chemistry we have been interested in

The Coupled Pendulum Experiment

HMQC HSQC and HMBC. Gradient HMQC, HMBC on the Bruker400 and 500

Inverted Pendulum System

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

MEASUREMENT OF THE CHARGE TO MASS RATIO (e/m e ) OF AN ELECTRON

Simulation of Second Order Spectra Using SpinWorks. CHEM/BCMB 8190 Biomolecular NMR UGA, Spring, 2005

Simple Harmonic Motion

Electric Fields and Equipotentials

Getting started with NMR

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

PHY 111L Activity 2 Introduction to Kinematics

Using Microsoft Excel

Lab 1: Intro to NMR. March 10, 2014

IFM Chemistry Computational Chemistry 2010, 7.5 hp LAB2. Computer laboratory exercise 1 (LAB2): Quantum chemical calculations

Lab 1 Uniform Motion - Graphing and Analyzing Motion

TALLINN UNIVERSITY OF TECHNOLOGY, INSTITUTE OF PHYSICS 6. THE TEMPERATURE DEPENDANCE OF RESISTANCE

BMB/Bi/Ch 173 Winter 2018

Measuring ph with Smart Cuvettes

Jasco V-670 absorption spectrometer

Zeeman Effect Physics 481

3/30/2017. Section 17.1 Spontaneous Processes and Entropy Thermodynamics vs. Kinetics. Chapter 17. Spontaneity, Entropy, and Free Energy

H-C one-bond correlations: HSQC Preliminaries.

Chem Page IX - 1 LAB MANUAL Differential Scanning Calorimetry 09_dsc131.docx EXPERIMENT IX

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Assignment 1: Molecular Mechanics (PART 1 25 points)

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

7 Infrared, Thermochemistry, UV-Vis, and NMR

Boyle s Law: A Multivariable Model and Interactive Animated Simulation

Remember that C is a constant and ë and n are variables. This equation now fits the template of a straight line:

Lab 5: Calculating an equilibrium constant

CHM Salicylic Acid Properties (r16) 1/11

Raman Spectroscopy of Liquids

NMR Spectroscopy Laboratory Experiment Introduction. 2. Theory

Assignment 2: Conformation Searching (50 points)

Introduction to Computer Tools and Uncertainties

Motion II. Goals and Introduction

Size Determination of Gold Nanoparticles using Mie Theory and Extinction Spectra

Chemistry 14CL. Worksheet for the Molecular Modeling Workshop. (Revised FULL Version 2012 J.W. Pang) (Modified A. A. Russell)

Lab #10 Atomic Radius Rubric o Missing 1 out of 4 o Missing 2 out of 4 o Missing 3 out of 4

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

SSSC Discovery Series NMR2 Multidimensional NMR Spectroscopy

NMR Predictor. Introduction

Structural Analysis of an Unknown Compound and Determination of its pk a by NMR Spectroscopy

Kinetics of Crystal Violet Bleaching

Calculating NMR Chemical Shifts for beta-ionone O

How to perform 2D NMR Experiments on the Varian/Agilent VNMRS 500 when using the Chempack interface

Operation Guide for 500MHz Bruker NMR

Experiment 0 ~ Introduction to Statistics and Excel Tutorial. Introduction to Statistics, Error and Measurement

Downloading GPS Waypoints

August 7, 2007 NUMERICAL SOLUTION OF LAPLACE'S EQUATION

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Simple Harmonic Motion

Chem 460 Laboratory Fall 2008 Experiment 3: Investigating Fumarase: ph Profile, Stereospecificity and Thermodynamics of Reaction

I. Pre-Lab Introduction

X-Nucleus NMR: 31 P and 19 F

Thermodynamics: Free Energy and Entropy. Suggested Reading: Chapter 19

Chapter 13: Nuclear Magnetic Resonance (NMR) Spectroscopy direct observation of the H s and C s of a molecules

Physics 2310 Lab #3 Driven Harmonic Oscillator

M61 1 M61.1 PC COMPUTER ASSISTED DETERMINATION OF ANGULAR ACCELERATION USING TORQUE AND MOMENT OF INERTIA

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

So far in talking about thermodynamics, we ve mostly limited ourselves to

Experiment 3: The Rovibrational Spectrum of HCl (was Experiment 4 in the syllabus, but the original Experiment 3 was canceled)

Atomic Spectra HISTORY AND THEORY

Project: Equilibrium Simulation

Computer simulation of radioactive decay

CHM201 General Chemistry and Laboratory I Laboratory 7 Thermochemistry and Hess s Law May 2, 2018

The OptiSage module. Use the OptiSage module for the assessment of Gibbs energy data. Table of contents

Error Analysis, Statistics and Graphing Workshop

Acid-Base ph Titration Introduction

Physical Chemistry Lab: The Hydrolysis of Aspirin. Each collaborative team determines the rate constant for the hydrolysis of aspirin.

STATISTICAL HANDLING OF RADIOACTIVITY MEASUREMENTS

Lecture Notes 1: Physical Equilibria Vapor Pressure

Let s continue our discussion on the interaction between Fe(III) and 6,7-dihydroxynaphthalene-2- sulfonate.

Athena Visual Software, Inc. 1

Experiment 10. Zeeman Effect. Introduction. Zeeman Effect Physics 244

APPENDIX 1 Version of 8/24/05 11:01 AM Simulation of H-NMR without a structure*:

Chem 310, Organic Chemistry Lab Molecular Modeling Using Macromodel

Transcription:

Experiment 4: Equilibrium Thermodynamics of a Keto-Enol Tautomerism Reaction Reading: SGN: Experiment 21 (p.256-263), Experiment 43 (p.456-459). Quanta: Nuclear magnetic resonance, Relaxation All reactions tend towards equilibrium. Equilibrium occurs when the concentrations of the reactants and products remain constant over time. Synthetic chemists try design reactions that achieve equilibrium when the concentrations of the products are much greater than those of the reactants: these are reactions that have high yields, or go to completion. owever, there are many useful and important reactions that reach an equilibrium state containing significant amounts of both products and reactants. In this experiment, you will characterize the equilibrium thermodynamics of the keto-enol tautomerization reaction for 2,4-pentanedione (also named acetylacetone, or acac). 3 C C 3 keto form 3 C C 3 3 C C 3 3 C C 3 enol form Figure 1: Keto-enol tautomerization reaction for 2,4-pentanedione. The two center enol structures are in fast exchange in this experiment, and can be treated as the single structure shown on the right. The relative amounts of products and reactants at equilibrium is characterized by the equilibrium constant. For this reaction, K eq is defined as: [ enol ] eq K eq = keto [ ] eq (1) where the subscript eq indicates that all concentrations are measured at equilibrium. The overall tendency for this reaction to occur (proceed to the right) is governed by the change in the Gibbs free energy, which at any time during the reaction is given by: ΔG = ΔG 0 +RT lnq (2) where ΔG 0 is the standard Gibbs free energy change, R is the gas constant, T is the temperature (in Kelvin), and Q is the reaction quotient. When the reaction reaches equilibrium, ΔG=0 and Q=K, so that: ΔG 0 = RT lnk eq (3) If the reactants are favored at equilibrium, K eq <1, and ΔG 0 >0. Conversely, if the products are favored, K eq >1, and ΔG 0 <0. nly if the equilibrium is perfectly balanced will K eq =1, and ΔG 0 =0. Thus, the standard free energy change indicates the position of the equilibrium (amounts of products and reactants) while the total free energy change indicates which direction the reaction must proceed to get to equilibrium. The change in Gibbs free energy is related to the changes in enthalpy (Δ 0 ) and entropy (ΔS 0 ) that accompany the reaction: 63

ΔG 0 = Δ 0 TΔS 0 (4) Fundamentally, it is the values of Δ 0 and ΔS 0 that govern the equilibrium position for the reaction. This reflects the contributions from the two driving forces in nature: the tendency towards lowest energy, and the tendency towards greatest entropy. For example, reactions that go to completion (i.e., K eq >1, and ΔG 0 <0) tend to be highly exothermic (Δ 0 <<0) or highly endergonic (ΔS 0 >>0). f course, this is not always the case, as there are many combinations of values of Δ 0, ΔS 0 and T that will result in a negative value for ΔG 0. The reverse reasoning holds for reactions that tend not to proceed (i.e., K eq <1, and ΔG 0 >0). The contributions to ΔG 0 from enthalpy and entropy can be experimentally determined by measuring the equilibrium constant as a function of temperature. Combining equations (3) and (4), we have: lnk eq = Δ 0 RT + ΔS 0 R From equation (5), we can see that a plot of lnk eq versus 1/T will yield values for Δ 0 and ΔS 0. In this experiment you will use NMR spectroscopy to measure the equilibrium constant for the keto-enol tautomerization of 2,4-pentanedione as a function of temperature in two different solvents. From this data, you will determine the standard enthalpy and entropy changes for the reaction in each solvent, which will allow you to discover the roles of entropy and enthalpy (energy) in the tautomerization reaction. You will also be able to gain some insight on the role of solvent in stabilizing or destabilizing the two forms of 2,4-pentanedione. An NMR spectrum of 2.4-pentandione in CDCl 3 is shown in Figure 2. The spectrum represents a mixture of keto and enol forms due to the equilibrium reaction in Figure 1. The spectrum is expanded to show the peaks of interest at ~5.3 ppm, 3.4 ppm, ~2.0 ppm, and ~1.8 ppm. (5) C 3 C enol C 2 keto 6.0 5.6 5.2 4.8 4.4 4.0 3.6 3.2 2.8 2.4 2.0 1.6 1.2 0.8 0.4 0.0 chemical shift (ppm) Figure 2: 300 Mz NMR spectrum of 2,4-pentanedione in CDCl 3 (expanded view). protons from the keto and enol forms have distinct chemical shifts. The methyl In an NMR spectrum, the integrated area under a peak is proportional to the concentration of that type of proton in solution. This means that the area is proportional to the concentration of the 64

compound in solution scaled by the number of protons per compound that contribute to the peak. There are two sets of protons that can be compared to obtain the equilibrium constant for reaction (1): (a) the protons on carbon 3, or (b) the methyl protons. In case (a), the enol C peak arises from one proton per molecule, while the keto C 2 peak arises from two protons per molecule. This means that one of the integrated areas should be divided by two in order to obtain relative concentrations. Let's suppose we had a mixture that was 1:1 keto:enol. In this case, we would expect the keto peak to be twice as large (there are twice as many protons contributing to that signal). But the concentration in this example is 1:1, so we should divide the keto C 2 area by two to obtain the correct concentration ratio. Thus, using the peaks arising from the protons on carbon 3: [ enol ] eq K eq = keto [ ] eq = ( C peak area) ( C 2 peak area / 2) In case (b), the enol C 3 peak arises from six protons per molecule, and the keto C 3 peak arises from six protons per molecule. Thus, using the methyl peaks: [ enol ] eq K eq = keto [ ] eq = C 3 enol ( peak area) ( C keto 3 peak area) In theory, both ways of calculating the equilibrium constant should yield the same results. The full NMR spectrum of 2,4-propanedione in CDCl 3 is shown in Figure 3: (6a) (6b) 0 enol CCl 3 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 chemical shift (ppm) Figure 3: Full 300 Mz NMR spectrum of 2,4-pentanedione in CDCl 3. The vertical scale is greatly expanded from that in Figure 2. The residual CCl 3 signal can be seen in Figure 3 at 7.25 ppm, as can the quite broad signal from the enol form. The signal is broad due to the fast exchange between the two enol forms. There is a small amount of contamination of the sample that is apparent at such a large scale expansion. The second solvent that you will use in this experiment is DMS-d6, which is very polar. Note that the two methyl peaks may not be distinct in DMS-d6, and that the residual DMS peak appears as a quintet at 2.50 ppm. 65

Do the following in your notebook before you come to lab: 1. Using the relative sizes of the C and C 2 peaks in Figure 2, determine which C 3 peak arises from the enol form, and which is from the keto form. 2. Look up the proton chemical shifts, boiling points, freezing points, densities, dielectric constants and dipole moments of CCl 3 and DMS; and the freezing point, boiling point, molecular weight, and density of 2,4-pentanedione. Enter all of these values in a table in your notebook, being sure to include complete references to the source of your information. 3. Calculate in your notebook the volume of 2,4-pentanedione that is required to make solutions that are 0.20 mole fraction in 2,4-pentanedione, using a solvent volume 0.50 ml. Calculate also the molarities of these solutions. Experimental Procedure: Apparatus: 300 Mz Bruker NMR Spectrometer; 2,4-pentanedione, CDCl 3, DMS-d6, NMR tubes, microsyringes. Note that the NMR tubes and syringes are quite expensive, so care should be taken in preparing samples! Caution: The magnet in any NMR spectrometer produces a significant magnetic field that extends beyond the immediate region of the spectrometer. Modern magnets have stray fields that are powerful enough to erase credit cards and destroy watches. For this reason, you should always place your watch, wallet, and any other metal jewelry, etc. on the table near the door before you approach the spectrometer console! Since some time will need to be spent getting comfortable with the instrument, each group will acquire only two spectra and the data will be shared by the class. Each group will be responsible for acquiring data at two temperatures in a given solvent (see Table 1). You will have approximately 40 minutes during lab time to acquire your data. This means that you must come to lab earlier than your scheduled time to prepare your sample. Table 1: Temperatures for the study of the keto-enol tautomerization of 2,4-pentanediol. Time Group # CDCl 3 (Day 1) Group # DMS-d6 (Day 2) 2:15 (Loh) 25 (Loh) 50 3:00 1 29, 33 4 55, 60 3:40 2 37, 41 5 65, 70 4:20 3 45, 50 6 75, 80 There are two keys to obtaining good data in any NMR experiment: (1) achieving thermal equilibrium in your sample before acquiring data, and (2) good shimming of the magnetic field (that is, making the magnetic field as homogeneous as possible around your sample). This experiment is particularly sensitive to both of these factors. To begin, insert your sample in the spectrometer and set the temperature controller to the correct temperature. It will take approximately 5-10 minutes for your sample to reach thermal equilibrium once the thermostat has stabilized. To help reduce waiting time, the previous person will have set the temperature for your 66

first spectrum before you come in. Be sure that you do the same for the next person when you complete your acquisition. Setting the Lock Signal: While you are waiting for the sample to equilibrate, you can set up the spectrometer parameters. Begin by turning the spinner on (press the spin button). In routine NMR work, the sample is spun (typically at ~20 z) to average out some of the field inhomogeneities in the x-y plane. Next, you need to optimize the deuterium lock signal. To do this, first press the field button and adjust the knob until the sweep pattern is symmetrical about the center of the screen. This sets the frequency of the deuterium signal coming from the deuterated solvent in your sample. Now press the lock phase button, and turn the knob until the left and right peaks in the sweep signal are of equal heights. This corrects the phase of the lock signal (you will see phasing again for the proton signal when you work up your data). Finally, press the lock button. As the spectrometer locks on the deuterium signal that you just set, the signal will climb up the screen and flatten out. You will have achieved a stable lock signal when the lock light stops flashing. Shimming: Now comes the most important, most time-consuming, and most black art part of NMR spectroscopy: shimming the field. The term shim comes from construction, where thin pieces of wood are used to level or even out the major pieces of interest. In NMR, shimming is performed by running a variable low current through different sets of small metal coils to produce small magnetic fields with different orientations. These are used to adjust the field around your sample in order to make the field as homogeneous as possible. A well-shimmed spectrum will have very narrow, Lorentzian (rather bell-shaped) peaks without jagged tops or lopsided edges (see Figure 4). (a) (b) 1.75 1.70 1.65 1.60 1.55 Chemical Shift (ppm) 2.00 1.95 1.90 1.85 1.80 Chemical Shift (ppm) Figure 4: Examples of spectra obtained with (a) a pretty good shim, and (b) a poor shim. The region around the peak has been expanded to observe the true line shape. The shim settings should be fairly close to ideal already, so all you need to do is adjust the Z and Z 2 shims until you get a maximum lock signal. A good shim file has been saved in case you really screw up the shims and can t get them back. To load this file, type: RS C313F04S.001 (for CDCl 3 samples) or RS C313F04S.002 (for DMS-d6 samples). To check the quality of your shim, you will need to take a spectrum. Acquiring a Spectrum: To acquire a spectrum, you will need to set the following parameters: load acquisition parameters into the NMR computer set the pulse width, or tip angle (we will use a 30 pulse - see below) set the receiver gain (the degree of amplification of the digital signal) set the number of scans to be collected and later averaged set the relaxation delay between scans 67

In a standard NMR spectrum, the bulk magnetization vector is tipped from its equilibrium alignment along the z-axis (vertical in NMR instruments, horizontal in MRI instruments) to a new orientation by the application of a small of magnetic field pulse. The detector sits in the xy-plane, so the maximum signal will be obtained if the vector is tipped by 90 (so that it lies in the xy-plane). The longer the pulse (or the greater the pulse power), the greater the tip angle. Since our samples are very concentrated, they are likely to produce a very strong signal, which can overload the detector electronics. Therefore, we will use only a 30 pulse. According to the latest calibration on our instrument for 1 nuclei, a pulse lasting 8.75 µs produced a 90 tip angle. Modern NMR spectrometers are Fourier transform instruments - this means that the entire spectrum of data is obtained at once (in the time domain), then mathematically transformed to produce a spectrum in the frequency domain. ne of the advantages of an FT instrument is that noise can be reduced by adding several spectra prior to Fourier transforming the data - the random noise cancels (in part), while the signal is enhanced. Since our samples are very concentrated, we should expect a very high signal-to-noise ratio, so only a few scans are necessary. For the same reason, we will start with a very low receiver gain. The relaxation delay is the time the instrument waits between scans in order to allow the magnetization vector to completely return to equilibrium. To acquire a spectrum, type in the following commands: RJ 010602.001 (press ENTER): loads the acquisition parameters into the NMR computer PJ (press ENTER twice): loads the processing parameters into the NMR computer RG (press ENTER) 1 : (sets the receiver gain) PW (press ENTER) 2.9: (sets the pulse width = 8.75 µs/3, or tip angle = 90 /3=30 ) NS (press ENTER) 8 : (sets the number of scans to be averaged) RD (press ENTER) 2 : (sets the time (in seconds) to wait between scans) GS (press ENTER) : (initiates a test scan) If everything is set up correctly, you should see a FID (Fourier induction decay: the raw NMR signal) appear on the screen. The FID represents the decay in the magnetization in the xy-plane versus time as the magnetization vector relaxes back to equilibrium along the z-axis. (see Figure 5). The oscillations in the decay represent the sum of all of the proton Larmor frequencies in the sample. The initial signal amplitude should be approximately 2 blocks high on the NMR computer screen. If the amplitude is too low, increase the size of RG (the receiver gain). nce the amplitude is set, press the CNTRL and K buttons to kill the test scan procedure. Enter ZG to begin the actual data acquisition. 13.0 12.0 11.0 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 time (sec) Figure 5: Sample FID of a reasonably well-shimmed sample. Notice the smooth exponential decay of the signal envelope. FID's that look bumpy or deformed are usually the result of poor shimming. 68

Data Processing and Visualization: To view your spectrum and check your shim, you need to export the data from the NMR computer to the PC. At the spectrometer console, save your spectrum by typing: WR C313XXXY.00Z, where XXX is the temperature in Kelvin, Y is your group number, and Z is the spectrum index (i.e.: 1 for the first attempt, etc.). Press the ENTER key: the screen will flash and you should get the prompt back if the file has been saved. Move to the PC computer and open the ASPLINK window. Enter 6 (options), and set the data directory to C:\NMRLINK\CM313\FALL04\. Enter 1 (import), and type the name of your file (C313XXXY.00Z). When the import is complete, you can minimize the ASPLINK window. To view and process the spectrum, open the NUTS window. pen your file using the FILE PEN menu option. The program will ask you if you want to use autodetect import; choose YES. You should see your FID when the file has been loaded. To process the data, type FT (Fourier transform), then P (phase). Click the right mouse button and drag the mouse back and forth until the baseline is flat (phased), then release the button and hit ENTER. Double click the left mouse button on a region near one of the peaks and highlight that peak. Click with the right button to zoom in on the peak - check to be sure the peak is a smooth, narrow Lorentzian shape (see Figure 4). If there are jagged edges or lumps you will need to reshim and reacquire a spectrum. nce you have a good spectrum, save a copy of the original FID as GDXXX.YQQ (where QQ are your initials) in the C:\NMRLINK\CM313\FALL04\ folder. Calculations: Save a copy of each of the good spectra on a floppy diskette and transfer these files into your Student Files folder on one of the Macs or a PC that has the NUTS software package. The Mac version of NUTS is called MacNutsPPC. pen the first spectrum file, and transform and phase the spectrum. Expand the vertical scale and find the residual solvent peak. Place your cursor on the center of the peak and type S while holding down the mouse button. A dialog box will appear: enter the chemical shift of the solvent peak. Set the display range to be 6 ppm - 0 ppm using the zoom control. To integrate the peak areas, type ID (integral subroutine) then type B (baseline correct the integrals). You should see an integral line that is parallel to the baseline where there are no peaks, but which jumps vertically at each peak. If this is not observed, hit return to exit the integration routine and type BC to correct the spectrum baseline. Re-enter integration mode. Cut the integrals close to each peak using the left mouse button (a NUTS manual is available in the lab if you get stuck; there is also a help menu in the NUTS program). If you make a mistake, typing C will clear all broken integrals. Also cut one integral where there are no peaks peaks this integral should have an intensity of zero when properly phased. Next place your cursor on the pentandione methyl protons peak and type V while holding down the mouse button. Enter a relative value of 100 in the dialog box that appears - this scales all of the integrals to a nice number. Type T to show the integral values on the screen. Phase the spectrum by typing P and sliding the mouse to the left or right while holding down the right mouse button. nce the spectrum is well-phased, record the integral values in a table in your notebook. Also print a copy of this spectrum, and label it with the file name, solvent, and temperature. Tape this spectrum into your notebook. For presentation purposes, you will create a stacked plot in Excel for each solvent set (see Using Excel, Part IV). In order to import the NMR data into Excel, you need to export the data in the processed spectrum in NUTS as a text file. Do this before you open the next spectrum! To export the spectrum as a text file, in NUTS choose File Export File PPM, Intensity ASC data pairs. 69

Give the exported file a name that makes sense. In Excel, choose File pen and navigate to the text file that you just created. A dialog box will pop up asking you how you want Excel to read the data. Choose Delimited and hit the NEXT button, then click the Tab and Comma boxes. Keep hitting the NEXT button until your data appears in the spreadsheet - it should be in two columns: PPM and Intensity. Delete all data outside of the 0-6 ppm range. Process the remaining spectra in the same way. Copy all of the PPM, Intensity data from a single solvent into one spreadsheet, and follow the instructions in Using Excel, Part IV to make the stacked plot. You should end up with 2 stacked plots, one for all the CDCl 3 spectra and one for all the DMS-d6 spectra. Remove the legend from the plots. Print each one on a full page with a complete Figure # and title, and write in the temperature for each spectrum on the plot by hand. For the CDCl 3 spectra, use equations (6a) and (6b) to calculate the equilibrium constant at each temperature. (Each group will probably have slightly different values at this point since the integrals will be cut slightly differently.) Enter your values for each set (a or b) of K eq and T (in Kelvin) in an LLS spreadsheet, then fit and plot the data according to equation (5). Calculate values for Δ 0 and ΔS 0 with 95% confidence limits in units of kj/mol and kj/mol K, respectively. You should end up with two sets of values for K eq, Δ 0 and ΔS 0, which should be fairly similar to each other. Repeat the analysis for the DMS-d6 spectra, then calculate Δ 0 and ΔS as for the CDCl 3 spectra. Wrapping it Up: Your notebook should have one table of all of the meaningful equilibrium data (i.e.: integrated areas, K eq, T, etc.), and another table of final results for Δ and ΔS, with units where appropriate and error limits. Look up and record in your notebook as many relevant literature values as possible: J. Chem. Ed., vol. 79 (2002), 707-714. Discuss (don't just answer the question as posed - support your ideas with experimental evidence) the following physical aspects of this experiment: Describe the physical interpretations of the signs on Δ and ΔS for the reaction in CDCl 3 (use the signs on the true, or literature, values in this discussion). Can you justify these observations based on your understanding of organic chemistry? Compare the equilibrium constants for the reaction in CDCl 3 and DMS-d6 at the same temperature. ow does changing the solvent polarity affect the equilibrium? What raw data do you have to support this observation? ow do enthalpy and entropy affect the equilibrium position of the reaction, and what is the role of temperature in the equilibrium position? ow can you explain the role of temperature in terms of the physical interpretations of Δ and ΔS? Compare the values of Δ and ΔS for the reaction in CDCl 3 and in DMS-d6 (use the signs on the true, or literature, values in this discussion). ow does changing the solvent polarity affect reactant vs. product stability and reactant vs. product entropy? Can you justify these observations based on your understanding of organic chemistry and bond behavior? Assess the accuracy and precision of your data by comparing your results to the literature values, and comparing your results for the CDCl 3 solutions obtained using data sets (a) and (b). 70