MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Similar documents
ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

MODEL : TX Series (Nom. sizes 15mm to 400mm)

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Integral V-Cone Flowmeter VD series

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

( Single Case Construction )

Electromagnetic Flowmeter

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Fitting PS P - B - R2

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

ED 701 General Industry Pressure Transmitter

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Field IT 50T Series Transmitters

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

PHOENIX CONTACT - 04/2016. Features

AM-1000 Series COMPACT FLOWMETER

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

E8EB-N0C2B E8EB-N0B2B

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

AM-1000 Series COMPACT FLOWMETER

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure. 1 Fitting PA R - N R2

Installation guide 862 MIT / MIR

Pressure Transmitter ED 701

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

Industrial Pressure Transmitter

Surface-mounting Thermostats ATH Type Series

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Industrial Pressure Transmitter

Target Insertion Flowmeter

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Surface-mounting thermostats Series ATH

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

AC axial compact fan

5SJ4...-.HG Circuit Breakers to IEC and UL 489

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

RoHS. Versatile. X g. X 2 e

tekcor TKC Multivariable Coriolis Flow Sensors

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

PG-200/PG-208 PRESSURE GAUGES P G G P P

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

ISEmax CAM40/CAS40. Technical Information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

No HOT WIRE ANEMOMETER MODEL SK-27V. SPECIFICATIONS Measurement object : Clean air at normal pressure and humidity

HEAT FLOW SENSORS MF-180 MF-180M MF-190 MF-200 INSTRUCTION MANUAL

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

VORTEX FLOWMETER (DELTA FLOWPET)

Non-Contact Safety Systems CMS

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

FLOW SENSOR FOR LIQUID MEDIA Serie 210

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

Applied Fluid Mechanics

Single point load cells

Route and retain the clinometer cable so that it does not interfere with moving parts where the unit is mounted.

Applied Fluid Mechanics

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

Technical specification FLUXUS F502TE

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

CS Series. Capacitance Type. Type. Proximity Sensor. Features

Solenoid valves Type EVUL

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

Best color perception in spotlighting and downlighting

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

FXP DATASHEET JUNHO 2013

AT9000 Advanced Transmitter Differential Pressure Transmitters

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Reflex-Radar BM 100 A

Pressure Measurement Single-range transmitters for general applications

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Transcription:

Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate is a compactly built Coriolis flowmeter integral with a transmitter and display. It is characterized by competitive price, outstanding performance, user friendliness, and operating safety to most effectively meet customer needs. It has expanded the range of precise metering at extreme low flow rates and the size of non-explosionproof instruments market. FEATURES. Low priced Coriolis flowmeter series 2. Single case construction with built-in probe and transmitter (with display) 3. Vibration-proof base not required 4. Simple installation and easy to use 5. Wetted parts material: SUS36L equivalent 6. Flow range: 2.5 to 2700 g/min in three types 7. CE-Marking TYPICAL APPLICATIONS. Mass flow measurement 2. Measurement of multiple kinds of liquid at laboratories or research facilities 3. Medicinal solution, solvent process 4. Slurry liquid, mixture process 5. Paint, spray, additive applications GENERAL SPECIFICATIONS Model CR002 CR003 CR004 Nominal Size 0.7mm.5mm 3mm Wetted parts SUS36L and SCS6A ( ) Materials Base ADC2 ADC2 SUS304 Housing and cover ADC2 Display shield Polycarbonate Process connection Rc /8 Acceptable fluid Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range 0 to +60 (Free of dew condensation) Max. operating pressure 2MPa Flow directions Forward flow only Power supply ( 2) 20 to 30VDC Power consumption Max. 0W Furnished cable AWG24 7-conductor, φ6.8 3m Dustproof, waterproof construction IP66 Installation Horizontal installation (clamp not required) Vertical installation (Bolthole provided) Display Backlit dot matrix: 8 digits Variables displayed Instant mass flow, mass flow total, temperature Weight Aprrox. 3kg Aprrox. 3kg Aprrox. 6.5kg Communication interface Bell 202 (using the HART protocol) Pulse output ( 3) Mass flow total open collector output (30V, 50mADC max.) FS: 0. to 0000Hz selectable CR002: 0.0g/P at 25Hz CR003: 0.0g/P at 500Hz CR004: 0.g/P at 450Hz 4 to 20mADC Max. load 600Ω Instant mass flowrate Damping: sec. (std.) Analog output ( 3) CR002: 0 to 75g/min CR003: 0 to 300g/min CR004: 0 to 2700g/min Applicable EU directive EMC directive: 2004/08/EC ( ): Corrosion resistance of nickel brazing used in wetted parts is equivalent to SUS34. ( 2): SU503 power unit is acceptable to this meter. (SU303 power unit cannot be applied.) ( 3): The pulse output at the time of the shipment and analog output are standard setting. (Setting change possible) Head Office (Tokyo): Tel. +8 3-3360-52 Fax. +8 3-3365-8605 International Sales Division Email: SK0@oval.co.jp Overseas Branch Offices: Beijing, Netherlands, Seoul, Singapore, Taipei http://www.oval.co.jp/english

CoriMate Ⅱ GBN064E-3 GENERAL PERFORMANCE Flow rate (Liquid) Model CR002 CR003 CR004 Max. Flow rate g/min Min. Analog range g/min Cutoff g/min ( ) Factory calibration accuracy Repeatability Analog accuracy 75 300 2700 5 20 80.5 6 54 ±0.% of F.S (Below 33% of flow rate) ±0.3% RD (33% to 00% of flow rate) ±0.07% of F.S. (Below 33% of flow rate) ±0.2% RD (33% to 00% of flow rate) Accuracy ±0.% of full scale ( ): The flow rate (output signal and indication level) becomes zero at cutoff level or lower. (Setting change by the customer is available.) METER ERROR Meter Error 3 2 0 2 3 0 20 40 60 80 00 Flow rate PRESSURE LOSSES 00 CR002 00 CR004 0 000mPas 0 0. 0.0 0.00 0.000 00mPas 0mPas mpas 0.0mPas 0. 0.0 0.00 0.000 000mPas 00mPas 0mPas mpas 0.0mPas 0.0000 0 00 0.0000 0 00 000 0000 00 0 0. 0.0 0.00 0.000 000mPas 00mPas 0mPas mpas 0.0mPas CR003 How to calculate the pressure loss Find pressure loss coefficient C from flow rate (g/min) and viscosity (mpa s). Then divide the coefficient C by specific gravity d ( with water) to find the pressure loss. That is ΔP= C d (MPa) For high viscosity liquids unable to calculate using these graphs, please consult us. 0.0000 0 00 000 Code No. 2 3 4 5 6 7 8 9 0 2 3 Model C R CoriMate 0 0 2 0.7mm, Flow range (g/min) : 2.5 to 75 (Rc/8) Nominal Size 0 0 3.5mm, Flow range (g/min) : 0 to 300 (Rc/8) 0 0 4 3mm, Flow range (g/min) : 90 to 2700 (Rc/8) Structural category D CoriMate Ⅱ Material S S SUS36L Process connection 2 Screw connection Connection rule 0 Always "0" Pressure category 0 Always "0" Transmitter construction N Non-explosionproof integral type transmitter Version code B

OVAL Coriolis Flowmeter CoriMateⅡ (Reference drawing) CR002 and CR003 GS. No. GBN064E OUTLINE DIMENSIONS [Unit in mm] 48.6 30.2 3 Inlet (Rc/8) 86 6 6 Outlet (Rc/8) Detail of A (Wiring) Power DC +(Brown) Power DC (Pink) Pulse output +(Blue) Pulse output (Gray) Analog output +(Green) Analog output (White) Ground (Yellow) 64 A Interconnect Cable (7-conductor, shielded) Cable Gland 02 Rc/8 2-φ4 Magnet for Switching Base pad 28 96 90 62 50 64 78 4-7 drill 2 c.bore 0.5 deep Bolthole (For hex socket headed bolt M6) The location of boltholes has been changed from that of the previous model (Production Code: CR004D-SS-200N). Model Nominal Size Max. allowable pressure (MPa) Weight (Approx.) (kg) CR002D-SS-200NB Rc/8 2.00 3.0 CR003D-SS-200NB Rc/8 2.00 3.0 No. Name Material Quantity Nozzle SCS6A 2 2 Flowtube SUS36L-TP 3 Housing and Cover ADC2 equivalent 4 Base ADC2 equivalent 5 Display shielding Polycarbonate

OVAL Coriolis Flowmeter CoriMateⅡ (Reference drawing) CR004 GS. No. GBN064E OUTLINE DIMENSIONS [Unit in mm] 48.6 30.2 3 Inlet (Rc/8) 86 6 Outlet (Rc/8) Detail of A (Wiring) Power DC +(Brown) Power DC (Pink) Pulse output +(Blue) Pulse output (Gray) Analog output +(Green) Analog output (White) Ground (Yellow) 64 A Interconnect Cable (7-conductor, shielded) Cable Gland 02 Rc/8 2-φ4 Magnet for Switching Base pad 28 96 90 (62) 50 (64) (82) 4-7 drill 2 c.bore 0 deep Bolthole (For hex socket headed bolt M6) The location of boltholes has been changed from that of the previous model (Production Code: CR004D-SS-200N). Model Nominal Size Max. allowable pressure (MPa) Weight (Approx.) (kg) CR004D-SS-200NB Rc/8 2.00 6.5 No. Name Material Quantity Nozzle SCS6A 2 2 Flowtube SUS36L-TP 3 Housing and Cover ADC2 equivalent 4 Base SUS304 5 Display shielding Polycarbonate

CoriMate Ⅱ GBN064E-3 PLEASE SUPPLY THE FOLLOWING INFORMATION WHEN YOU INQUIRE (Fill in the form below to the extent possible. Further details will be finalized in later consultation.). Sensor unit CR D SS 200NB 2. Process fluid( ) Name SP. gr Viscosity Concentration % 3. Flow range Max. Normal Full scale g/min Others 4. Fluid temperature Max. Normal Min. 5. Operating pressure Max. MPa Normal MPa Min. MPa 6. Ambient temperature Max. Normal : Special fluids, such as of high viscosity fluids or slurries, should be stated precisely and in detail. GS.No.GBN064E 初版改訂印刷.09 4.05 2.06 (500) The specification as of May, 204 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: Strada Antica di None, 28/a - 0043 Orbassano (TO) Tel: 09040296 Fax: 09040389 info@asitinstruments.it www.asitinstruments.it