AppNote 2/2004. Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Similar documents
AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

AppNote 5/2002. Characterization of a Mass Spectrometer based Electronic Nose for Routine Quality Control Measurements of Flavors KEYWORDS ABSTRACT

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 8/2002 KEYWORDS ABSTRACT. Electronic Nose, Fast GC, Headspace Analysis, Chemometrics,

AppNote 7/2002. Classifi cation of Food and Flavor Samples using a Chemical Sensor KEYWORDS ABSTRACT

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

AromaOffi ce: Application of a Novel Linear Retention Indices Database to a Complex Hop Essential Oil

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

AppNote 3/2007 KEYWORDS INTRODUCTION. Beverage, Detector, Headspace, Quality Control

AppNote 4/1998. New Developments in Multi-Dimensional Capillary Gas Chromatography KEYWORDS ABSTRACT

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, D Mülheim an der Ruhr, Germany

Thermal Desorption Unit TDU

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

Off-gassing of Rubber Particles Used for Athletic Fields using Automated Dynamic Headspace Sampling

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

AppNote 8/2009. Fragrance Profi ling of Consumer Products using a Fully Automated Dynamic Headspace System KEYWORDS ABSTRACT

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 4/2005. A Selectable Single or Multidimensional. Fraction Collection and Dual Detection for Trace Analysis of Complex Samples KEYWORDS

AppNote 6/2012. Flavor and Fragrance Analysis of Consumer Products - Dynamic Headspace Compared to Some Traditional Analysis Approaches KEYWORDS

AppNote 2/2007. Automated Solid Phase Microextraction using the GERSTEL MPS Prepstation and MAESTRO Software KEYWORDS ABSTRACT

AppNote 1/2011 KEYWORDS ABSTRACT

AppNote 9/2012. Solid Phase Micro-Extraction (SPME) Coupled with Selectable 1 D/ 2 D GC-MS for the Determination of Food Product Flavors KEYWORDS

AppNote 8/2000. Volatile Organic Compounds from Adhesives and their Contribution to Indoor Air Problems KEY WORDS ABSTRACT

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT

AppNote 8/2012. Rapid Automated Extraction and Confi rmation of Buprenorphine and Norbuprenorphine in Urine by DPX-LC/MS/MS KEYWORDS ABSTRACT

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

AppNote 3/2012. Rapid Automated Screening of Extractable Compounds in Materials for Food Packaging, Medical or Technical Purposes KEYWORDS ABSTRACT

AppNote 2/2013. A High Throughput Automated Sample Preparation and Analysis Workfl ow for Comprehensive Toxicology Urine Screenings using LC/MS/MS

AppNote 7/2014. Automating Liquid-Liquid Extractions using a Bench-top Workstation KEYWORDS ABSTRACT. Sample Preparation, Lab Automation, LC/MS/MS

AppNote 5/2001. The Analysis of the Bitter and Other Flavour Compounds in Beer and Wort by Stir Bar Sorptive Extraction (SBSE) Followed by HPLC

AppNote 7/2005. Detection of Packaging Emissions using a Flexible Headspace Sampler Combined with a Multi Sensor System and a Separation Unit KEYWORDS

AppNote 1/2013. Determination of Barbiturates and 11-Nor-9-carboxy- 9 -THC in Urine using Automated Disposable Pipette Extraction (DPX) and LC/MS/MS

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

AppNote 8/2011 KEYWORDS ABSTRACT INTRODUCTION

AppNote 2/1998. Direct Injection of Distilled Spirits with PTV Matrix Removal: The Perfect Splitless Injection? KEYWORDS INTRODUCTION

AppNote 12/2008 KEYWORDS ABSTRACT

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

GERSTEL MultiPurpose Sampler MPS. Versatile autosampler and sample preparation robot

KEYWORDS ABSTRACT AppNote 6/2002

AppNote 3/1998 KEYWORDS ABSTRACT. Beverage, Food & Flavor, PTV, Large Volume Injection, Headspace, Thermal Desorption.

Selective Sample Enrichment of Gaseous Samples using a Cooled Injection System: Trace Determination of Sulphur Components in Natural Gas

AppNote 5/1994. The Use of a Multi Purpose Sampler for Headspace GC-MS Analysis of Volatile Organic Compounds in Human Urine

AppNote 12/2012. Comparison of EG-Silicone-SBSE and Derivatization-PDMS-SBSE for the Analysis of Phenolic Compounds and Off-fl avors in Water KEYWORDS

AppNote 11/2012. Fully Automated Analysis of Doping Substances in Equine Urine by Disposable Pipette Extraction (DPX) coupled to GC/QqQ-MS KEYWORDS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

AppNote 8/2001 KEYWORDS ABSTRACT. PAH, SPME, SBSE, GERSTEL Twister, Thermal desorption, GC-MS, PCB

AppNote 6/2010. part b. High Throughput Method for the Determination of PAHs in Seafood by QuEChERS-SBSE-GC-MS SCOPE PRINCIPLE

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Determination of Volatile Substances Proof of Food Adulteration

AppNote 7/2013. Comprehensive Automation of the SPE- GC/MS Analysis of Opioids, Cocaine and Metabolites from Serum and Other Matrices KEYWORDS

AppNote 2/2015 KEYWORDS ABSTRACT

AppNote 3/2011. Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice KEYWORDS ABSTRACT

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

PAL SPME Arrow The Better SPME

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

PAL SPME Arrow The Better SPME

GERSTEL Thermal Desorption System TDS 3 The GERSTEL TDS 3 is a flexible multi-functional thermal desorption system for highly sensitive and accurate d

Determination of Formaldehyde and VOCs in Wood-based Products using an Automated Micro-Scale Chamber

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

GC/MS Application Note

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Application Note. Abstract. Authors. Introduction

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

GC/MS Analysis Laboratory Report

AppNote 2/1999. Automated Sample Fractionation and Analysis Using a Modular LC-GC System

Chemometrics. Classification of Mycobacteria by HPLC and Pattern Recognition. Application Note. Abstract

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Headspace Technology for GC and GC/MS: Features, benefits & applications

AppNote 7/1994. Friedhelm Rogies, Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

Automated and accurate component detection using reference mass spectra

Application. Gas Chromatography February Introduction

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

White Paper. Application of GC-MS/MS in the Analysis of Taints and Off Flavours. Alan Rose Technical Specialist. Donna Byrom Technical Specialist

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Signal, Noise, and Detection Limits in Mass Spectrometry

ChromTech options for PAL systems

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Application of Raman Spectroscopy for Detection of Aflatoxins and Fumonisins in Ground Maize Samples

Transcription:

AppNote 2/2004 Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton Gerstel, Inc., Caton Research Center, 1510 Caton Center rive, Suite H, Baltimore, M 21227, USA Arnd C. Heiden, Carlos Gil Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, -45473 Mülheim an der Ruhr, Germany KEYWRS Paper/Pulp, Polymers & Plastics, Pattern Recognition, Mass Spectrometry. ABSTRACT Packaging materials for foodstuffs or consumer usage must not alter the flavor or odor of the substance being packaged. Examples of packaging materials include the paper used to wrap cigarettes, the paper cartons used in orange juice or milk and the Polyethylene (PE) often used for caps to seal soft drink bottles. Sometimes, due to differences in the raw materials or changes in the production processes, chemical inconsistencies can be found in these packaging materials. For example, a common issue with packaging materials is encountered when they emit off-odors. Traditionally acceptance of batches is often based on sensory panels. However this is very subjective and time consuming. Ideally an objective and fast screening system should be located directly at the production floor. This is a typical application for chemical sensors.

In this study, paper and PE samples classified as acceptable (no-odor) and unacceptable (off-odor) were used to train a mass spectral based chemical sensor. This sensor incorporates well-known mass spectrometry technology with multivariate data analysis. The mass spectral fingerprint obtained with the sensor was used to create multivariate classification models that were later used to classify unknown samples as acceptable or unacceptable. Unknown samples for these two applications were successfully classified using KNN classification models. In addition the results of the PE samples were compared to those obtained by the sensory panel. These results are encouraging, due to the level of accuracy and shorter analysis times compared to traditional (e.g. GC/MS) techniques. In a third application we analyzed ppb amounts of TPGA in milk and orange juice cartons with the Headspace ChemSensor. This was possible using the MS in selected ion monitoring mode. INTRUCTIN The use of static headspace (HS) coupled to a gas chromatograph (GC) or a GC-mass spectrometer (GC/MS) is widely used to detect contaminants in food packaging. For example, in 1979 the Ministry of Health in Germany indicated HS-GC as the official method to detect trace monomeric vinyl chloride in products made of PVC and in the foodstuff that is in direct contact with them [1]. Although GC/MS has proven to be a reliable analytical technique, its drawbacks include long analysis times and difficult interpretation of results by inexperienced personnel. The use of a headspace-mass spectrometry based chemical sensor retains the benefits of using mass spectrometry but speed the analysis substantially when compared to GC/MS. Faster analysis times are a result of not having a long chromatography column and easy customized reports are displayed instead of total ion chromatograms. In this study we examine three different packaging applications of a MS based ChemSensor. The first application deals with specialty papers. The papers used in food and cigarettes packaging require materials with minimum odor. Up to now, these papers are frequently evaluated by a sensory panel (Robinson test). We investigated using the ChemSensor to obtain faster and more objective responses than the ones obtained with the sensory panel. The objective was to classify the paper samples into low odor and high odor lots. AN/2004/02-2 The second application deals with the differentiation of good and bad lots of PE granulate. PE is used in the manufacturing of packaging material for the food industry. These packaging materials are not allowed to have any own odor in order to avoid contamination of the food. ur goal was to use the ChemSensor and provide a fast and objective device to classify samples into no odor and odor lots. The last application deals with the detection of tri (propylene glycol) diacrylate (TPGA) in milk and orange juice cartons. The current method used to detect this compound is time-consuming [2]; therefore, a replacement method should be faster and able to detect TPGA in the ppb range. EXPERIMENTAL A. Specialty packaging papers. 4 different paper types were analyzed. Prior Robinson test results performed by a customer showed that sample type # 1 had the lowest odor and sample # 3 the highest odor. ne paper strip (3.5 cm x 23 cm) of each sample was coiled up and transferred into a 10 ml vial. The vial was immediately sealed with a crimp cap. Analysis conditions. Incubation 120 C (30 min) Injection 2.5 ml, split 20:1, at 180 C MS scan mode, 35-200 amu, 1.0 min runs B. PE samples. 18 PE granulate samples were provided by a customer. Eight were reference samples and 10 unknown samples. The reference samples were four samples with acceptable odor and four with reject off-odor. 3 g of each sample was weight into 10 ml vials which were immediately sealed with crimp caps. The analysis consisted of 5 replicas of each reference sample and 3 replicas of each unknown sample. Analysis conditions. Incubation 80 C (20 min) Injection 2 ml, split 5:1, at 180 C MS scan mode, 35-150 amu, 1.0 min runs ne sample of each type was also analyzed with chromatographic separation by static HS using a GC-MS instrument equipped with a MultiPurpose Sampler MPS 2 (GERSTEL Headspace ChemSensor System). C. Milk and orange juice cartons. Four paper samples were analyzed: samples A and B with low TPGA

level; sample C in the 75 ppb range level and sample, a 100 ppb standard. Approximately 2.0 g of each of the inside of each carton were weighed into 20 ml vials. The analysis consisted of at least 8 replicas of each carton (Note: because of the difficulty of manually peeling the inside of the cartons, the true amount of TPGA was not consistent in the 2.0 g samples). Analysis conditions. Incubation 85 C (25 min) Injection 2 ml, split 10:1, at 180 C MS SIM mode, Ions 41, 55, 71, 85, 113, 135, 157, 171, 215, 225 Also, the pure TPGA standard was analyzed and a mass fingerprint was obtained for this compound. RESULTS AN ISCUSSIN A. Specialty packaging papers. The entire HS volatiles of each paper were analyzed using static HS coupled to a MS (Figure 1). Figure 1. GERSTEL Headspace ChemSensor. Using a special set of GERSTEL ChemSensor macros for the Agilent MS ChemStation an ASCII file is automatically created after each run. The ASCII file contains a characteristic mass spectral fingerprint that can be used to train the ChemSensor. These fingerprints for each type of paper are displayed using lineplots in Figure 2. 30 type 1 type 2 type 3 type 4 Response (E+05) 20 10 0 84 m/z AN/2004/02-3 134 184 Figure 2. Mass spectral lineplots of specialty packaging paper obtained after sampling with static HS Chem- Sensor. Samples were equilibrated at 120 ºC.

The x axis in Figure 2 represents the ions (m/z) and the y-axis their abundance. Note that the first ions (m/z 35-45) are not displayed in Figure 2 because their abundances are too high. Inspection of this plot reveals enough differences in the ion abundance ratios of different sample types as expected. nly the orange traces (sample type # 1) show very little abundance, this is in accordance to its low odor (Robinson test). Two chemometric classification models were created with the above data. SIMCA uses principal component analysis (PCA) to model the shape and position of the samples. An acceptance region (confidence interval) is then created for each different type of class. The interclass distance between sample types is reported in Table 1. Table 1. Interclass distances between classes. CS1 CS2 CS3 CS2 8.9 CS3 54.8 42.5 CS4 33.1 16.1 27.5 As a rule of thumb an interclass distance of higher than 3 indicates that the samples are separable. For this analysis, it can be seen that there is sufficient separation for almost all sample types. The SIMCA 3-plot as seen in Figure 3 visualizes this finding. type 4 PC2 type 1 PC1 PC3 type 2 type 3 Figure 3. SIMCA model for specialty packaging paper obtained after sampling with static HS ChemSensor. Samples were equilibrated at 120 ºC. The second classification model used was K-Nearest Neighbors (KNN). KNN is a model that classifies unknowns based on their proximity to samples already placed in categories. For the model building only sample types # 1 and # 3 were used. Sample type # 1 represents the low-odor category and type # 3 the high-odor category. The distance between an unknown (sample types # 2 and # 4) and a set of samples with known class is calculated. The unknown is then classified according to its closest K samples. Using KNN all samples of type # 2 were predicted into the low-odor category (type # 1) and all samples of type # 4 into the high-odor category (type # 3). AN/2004/02-4

B. PE samples. After close examination of the PE reference samples using their mass fingerprints, it was found that two reference samples had extremely high responses. Samples labeled F and G show much It is obvious that samples F and G have very high levels of ions 44 and 74 when compared to the rest of the reference samples. To obtain a better visual clashigher signals. Figure 4 shows the low odor samples with green traces and the samples with off-odor with orange traces. 120 F Response (E+06) 80 G 40 0 39 m/z 44 49 F 400 Response (E+05) 300 200 100 G F 0 54 74 94 m/z 114 134 Figure 4. Mass spectral lineplots (upper plots: m/z 35-50, lower plots: m/z 51-150) of PE samples with static HS ChemSensor. The high odor samples are orange traces and the low odor samples are green traces. sification these extreme bad samples where excluded from the data set. AN/2004/02-5

Two chemometric models were created with the above data: SIMCA and KNN. For SIMCA only the good sample types were used to create the model. All bad samples should then be predicted as unknown. Figure 5 shows the class probability plot of the reference samples. The green line represents a 95 % confident interval (y-axis) which seems to be reasonable for these samples. 1.0 G E F H G E F H GEF H G EF 0.8 CS1@3 0.6 C A C A C A C B B 0.4 K Sample Name Figure 5. SIMCA class probability plot for PE good reference samples (green projections) and bad samples (orange projections). A probability of 1 means no correlation between the sample and the model. I B L We created a K-Nearest Neighbors (KNN) model with two categories (bad and good) and set K to 4. Using KNN, sample types I, K and L predicted into the bad category. SIMCA results depended highly on the prediction probability. Setting the probability to 95 % only a few samples were predicted into the good category. At a higher probability, e.g. 99.9 % similar results to KNN were achieved. Figure 6 shows the class probability plot. epending on the prediction probability samples like N, or Q could be classified as good (below the probability line) or not. The final decision which probability is correct should be based on results taken from representative reference methods. 1.0 N KI L KI N L KI N L Q J 0.96 R J Q R CS1@3 0.92 M M P M Q R 0.88 P 0.84 J K P Sample Name Figure 6. SIMCA prediction Class Probability plot for PE unknown samples. Green line 99.9 % confidence interval, red line 95 %. AN/2004/02-6 I L

C. Milk and orange juice cartons. The structure of TPGA is shown in Figure 7. A mass spectral fingerprint of TPGA was obtained using the neat standard. Figure 7 shows that the main ions for this compound are 55 and 113, which can be attributed to the acryloyl ion (55, [CH2=CH-C=]+) and to an acryloyl group in which a propyloxy unit is attached (113, [CH2=CH- C-CHCH3--CH2]+). Abundance 113 2000000 1600000 55 1200000 800000 400000 m/z--> 40 80 120 160 200 240 Figure 7. Mass spectrum of tri (propylene glycol) diacrylate (TPGA). Initially, all four samples were analyzed in the SCAN and SIM mode. Figure 8 shows an extracted ion chromatogram overlay of ion 113 for sample C using SCAN and SIM mode. Because of the higher response using SIM; we decided to continue all ChemSensor analysis in the SIM mode. [Note: recent experiments using the ChemSensor in the SIM and SCAN mode indicate that higher sensitivity depends on several parameters like scan rate, number of SIM ions, dwell time, etc. In some cases higher sensitivity is not always achieved when the ChemSensor is run in the SIM mode]. Abundance 1000 800 600 400 200 Time--> 0.50 1.00 1.50 Figure 8. Extracted ion chromatogram overlay for mass 113 obtained by sampling the HS of sample C. The yellow trace was obtained using a scan range of 50-160 amu and the white trace using the MS in the SIM mode, 10 masses. AN/2004/02-7

Figure 9 shows a class projections plot for the SIMCA model obtained while sampling the static HS. For this model, 3 classes were used: samples A and B were grouped together into one class (low level of TPGA), sample C (75 ppb) and (100 ppb). It can be seen from this plot that there are three different, well-separated clusters. The interclass distances between these samples ranged from 6.2 to 7.5. A PC2 C B PC1 PC3 Figure 9. Class Projections plot for a SIMCA model with three classes (samples A and B were grouped together). Samples were analyzed using the GERSTEL Headspace ChemSensor in the SIM mode. In a separate experiment, we analyzed the four samples using an enrichment technique. Using Stir Bar Sorptive Extraction (SBSE), we found differences in the samples that were not related to their levels of TPGA. These results indicate that there could be sample variability in the cartons themselves. The level of TPGA in the cartons is determined by migration from the printed carton to the unprinted side of the next stacked carton, this migration may change from carton to carton. It is recommended that the standard sample has the same composition as the other samples and only differ in the level of TPGA. CNCLUSINS Using a MS based ChemSensor we were able to train the instrument to detect packaging materials that had unacceptable odors. The analysis times were fast and prediction of unknown samples was accurate. Using the ChemSensor in the headspace (HS)-SIM mode we were able to detect fragments of TPGA in samples C and. We will expand this application to test the ChemSensor in the SPME mode which we expect to provide higher sensitivity. REFERENCES [1] Kolb, B. & Ettre, L. S. Static Headspace-Gas Chromatography Theory and Practice, Wiley- VCH, New York 1997. [2] Marek, T. & Grollmann, U., IC Technical Review, 1999, 5, 93. AN/2004/02-8

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 igital rive, Suite J Linthicum, M 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 +41 (41) 9 21 97 25 swiss@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower ne Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br CERTIFIE QM-SYSTEM IS 9001 IS C E RTIFIC AT E 9 0 0 1:2 0 0 8 N. 0086 Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability